Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 113512, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461481

RESUMO

Dedicated nuclear diagnostics have been designed, developed, and built within EUROFUSION enhancement programs in the last ten years for installation at the Joint European Torus and capable of operation in high power Deuterium-Tritium (DT) plasmas. The recent DT Experiment campaign, called DTE2, has been successfully carried out in the second half of 2021 and provides a unique opportunity to evaluate the performance of the new nuclear diagnostics and for an understanding of their behavior in the record high 14 MeV neutron yields (up to 4.7 × 1018 n/s) and total number of neutrons (up to 2 × 1019 n) achieved on a tokamak. In this work, we will focus on the 14 MeV high resolution neutron spectrometers based on artificial diamonds which, for the first time, have extensively been used to measure 14 MeV DT neutron spectra with unprecedented energy resolution (Full Width at Half Maximum of ≈1% at 14 MeV). The work will describe their long-term stability and operation over the DTE2 campaign as well as their performance as neutron spectrometers in terms of achieved energy resolution and high rate capability. This important experience will be used to outline the concept of a spectroscopic neutron camera for the SPARC tokamak. The proposed neutron camera will be the first one to feature the dual capability to measure (i) the 2.5 and 14 MeV neutron emissivity profile via the conventional neutron detectors based on liquid or plastics scintillators and (ii) the 14 MeV neutron spectral emission via the use of high-resolution diamond-based spectrometers. The new opportunities opened by the spectroscopic neutron camera to measure plasma parameters will be discussed.

2.
Rev Sci Instrum ; 93(9): 093525, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182521

RESUMO

The most performant deuterium-tritium (DT) plasma discharges realized by the Joint European Torus (JET) tokamak in the recent DT campaign have produced neutron yields on the order of 1018 n/s. At such high neutron yields, gamma-ray spectroscopy measurements with scintillators are challenging as events from the neutron-induced background often dominate over the signal, leading to a significant fraction of pileup events and instability of the photodetector gain along with the consequent degradation of the reconstructed spectrum. Here, we describe the solutions adopted for the tangential lanthanum bromide spectrometer installed at JET. A data acquisition system with free streaming mode digitization capabilities for the entire duration of the discharge has been used to solve dead-time related issues and a data reconstruction code with pileup recovery and photodetector gain drift restoration has been implemented for off-line analysis of the data. This work focuses on the acquired data storage and parsing, with a detailed explanation of the pileup recovery and gain drift restoration algorithms.

3.
Rev Sci Instrum ; 93(9): 093520, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182523

RESUMO

A new deuterium-tritium experimental, DTE2, campaign has been conducted at the Joint European Torus (JET) between August 2021 and late December 2021. Motivated by significant enhancements in the past decade at JET, such as the ITER-like wall and enhanced auxiliary heating power, the campaign achieved a new fusion energy world record and performed a broad range of fundamental experiments to inform ITER physics scenarios and operations. New capabilities in the area of fusion product measurements by nuclear diagnostics were available as a result of a decade long enhancement program. These have been tested for the first time in DTE2 and a concise overview is provided here. Confined alpha particle measurements by gamma-ray spectroscopy were successfully demonstrated, albeit with limitations at neutron rates higher than some 1017 n/s. High resolution neutron spectroscopy measurements with the magnetic proton recoil instrument were complemented by novel data from a set of synthetic diamond detectors, which enabled studies of the supra-thermal contributions to the neutron emission. In the area of escaping fast ion diagnostics, a lost fast ion detector and a set of Faraday cups made it possible to determine information on the velocity space and poloidal distribution of the lost alpha particles for the first time. This extensive set of data provides unique information for fundamental physics studies and validation of the numerical models, which are key to inform the physics and scenarios of ITER.

4.
Rev Sci Instrum ; 92(4): 043537, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243441

RESUMO

A new tangential gamma-ray spectrometer has been developed for fast ion measurements in deuterium and deuterium-tritium plasmas of the Joint European Torus (JET). The instrument is based on a LaBr3 crystal with a photo-multiplier tube and replaces a pre-existing bismuth germanate detector, providing enhanced energy resolution and a counting rate capability in the MHz range. The line of sight is equipped with a LiH attenuator, which reduces the background due to 14 MeV neutron interactions with the crystal by more than two orders of magnitude and enables the observation of gamma-ray emission from confined α particles in JET deuterium-tritium plasmas. Thanks to its tangential line of sight, the detector can distinguish co- and counter-passing ions. The performance of the instrument is demonstrated through the results of recent JET fast ion experiments in deuterium plasmas.

5.
Crit Rev Anal Chem ; 49(2): 150-159, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30285479

RESUMO

The complexity of biological objects and the rapid change in their composition after sampling, the variety of compounds of different chemical nature, possessing oxidative and antioxidant properties, make the task of its estimating extremely nontrivial and important for food, nutrients and human health characterization. The paper discusses the use of potentiometry in determining integral antioxidant/oxidant activity mainly of biological fluids and human skin. The source of information is the electrode potential shift that occurs when the analyzed object is inserted in the solution of the mediator system or when the mediator system is exposed to human skin. The experimental approaches, protocols, calculations are described. A number of examples of antioxidant activity and oxidative stress estimation in medicine are presented. The works show lower levels of antioxidant activity (AOA) of plasma and blood serum in patients with cardiovascular diseases, obesity, and malignant neoplasms as compared with the healthy volunteers. It was found out that antioxidant activity of fertile men semen is higher than AOA of infertile patients. Using the method discussed have shown that in some infertile male patients antioxidant activity of semen has been accompanied by oxidant activity. It has been found, that antioxidant activity of skin increases after intake of ascorbic acid and vitamin-enriched juices. The described approach holds considerable promise for monitoring oxidative stress of the whole organism and its systems, and for selecting effective and safe therapy. Thus, it opens up new opportunities in expanding the use of analytical chemistry in such an important field as medicine.


Assuntos
Antioxidantes/metabolismo , Medicina , Estresse Oxidativo , Potenciometria/métodos , Doença , Humanos
6.
Crit Rev Biomed Eng ; 28(5-6): 160-82, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11211981

RESUMO

Time-and-frequency fluctuation intensity distributions' analysis is made of the electromagnetic radiation obtained from deep human brain structures. The role of monitoring the distribution changes due to various cerebral circulation disorders is explained.


Assuntos
Encéfalo/fisiologia , Fenômenos Eletromagnéticos , Adulto , Fenômenos Biofísicos , Biofísica , Encéfalo/efeitos dos fármacos , Encéfalo/fisiopatologia , Isquemia Encefálica/fisiopatologia , Cafeína , Circulação Cerebrovascular/fisiologia , Força Compressiva , Feminino , Humanos , Arteriosclerose Intracraniana/fisiopatologia , Masculino , Pessoa de Meia-Idade , Enxaqueca com Aura/fisiopatologia , Modelos Neurológicos , Termografia , Simulação de Ausência de Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...