Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Blood Cells Mol Dis ; 107: 102856, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38762921

RESUMO

COVID-19 disease progression can be accompanied by a "cytokine storm" that leads to secondary sequelae such as acute respiratory distress syndrome. Several inflammatory cytokines have been associated with COVID-19 disease progression, but have high daily intra-individual variability. In contrast, we have shown that the inflammatory biomarker γ' fibrinogen (GPF) has a 6-fold lower coefficient of variability compared to other inflammatory markers such as hs-CRP. The aims of the study were to measure GPF in serial blood samples from COVID-19 patients at a tertiary care medical center in order to investigate its association with clinical measures of disease progression. COVID-19 patients were retrospectively enrolled between 3/16/2020 and 8/1/2020. GPF was measured using a commercial ELISA. We found that COVID-19 patients can develop extraordinarily high levels of GPF. Our results showed that ten out of the eighteen patients with COVID-19 had the highest levels of GPF ever recorded. The previous highest GPF level of 80.3 mg/dL was found in a study of 10,601 participants in the ARIC study. GPF levels were significantly associated with the need for ECMO and mortality. These findings have potential implications regarding prophylactic anticoagulation of COVID-19 patients.


Assuntos
Biomarcadores , COVID-19 , Fibrinogênio , SARS-CoV-2 , Humanos , COVID-19/sangue , COVID-19/complicações , Masculino , Feminino , Pessoa de Meia-Idade , Fibrinogênio/análise , Fibrinogênio/metabolismo , Estudos Retrospectivos , Idoso , Biomarcadores/sangue , Adulto , Progressão da Doença
2.
J Clin Invest ; 134(6)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38227381

RESUMO

BACKGROUNDVaccination is typically administered without regard to site of prior vaccination, but this factor may substantially affect downstream immune responses.METHODSWe assessed serological responses to initial COVID-19 vaccination in baseline seronegative adults who received second-dose boosters in the ipsilateral or contralateral arm relative to initial vaccination. We measured serum SARS-CoV-2 spike-specific Ig, receptor-binding domain-specific (RBD-specific) IgG, SARS-CoV-2 nucleocapsid-specific IgG, and neutralizing antibody titers against SARS-CoV-2.D614G (early strain) and SARS-CoV-2.B.1.1.529 (Omicron) at approximately 0.6, 8, and 14 months after boosting.RESULTSIn 947 individuals, contralateral boosting was associated with higher spike-specific serum Ig, and this effect increased over time, from a 1.1-fold to a 1.4-fold increase by 14 months (P < 0.001). A similar pattern was seen for RBD-specific IgG. Among 54 pairs matched for age, sex, and relevant time intervals, arm groups had similar antibody levels at study visit 2 (W2), but contralateral boosting resulted in significantly higher binding and neutralizing antibody titers at W3 and W4, with progressive increase over time, ranging from 1.3-fold (total Ig, P = 0.007) to 4.0-fold (pseudovirus neutralization to B.1.1.529, P < 0.001).CONCLUSIONSIn previously unexposed adults receiving an initial vaccine series with the BNT162b2 mRNA COVID-19 vaccine, contralateral boosting substantially increases antibody magnitude and breadth at times beyond 3 weeks after vaccination. This effect should be considered during arm selection in the context of multidose vaccine regimens.FUNDINGM.J. Murdock Charitable Trust, OHSU Foundation, NIH.


Assuntos
Formação de Anticorpos , Vacinas contra COVID-19 , Adulto , Humanos , Vacina BNT162 , Vacinação , Anticorpos Antivirais , Imunoglobulina G , RNA Mensageiro , Anticorpos Neutralizantes
3.
J Appl Lab Med ; 7(3): 650-660, 2022 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-35015866

RESUMO

BACKGROUND: Preanalytical errors due to poor sample quality or improper sample handling may occur with point-of-care testing (POCT). METHODS: A retrospective analysis was conducted using deidentified records for 15 479 i-STAT® cartridges run at the Oregon Health & Science University Emergency Department (ED) between December 2015 and August 2016. Data were collected from electronic health records and device middleware for CG4+, CHEM8+, and Troponin cartridges. The frequency of POCT errors was evaluated by cartridge type. The effect of user experience on error frequency, impact of error on hospital length of stay (LOS), and test turnaround time (TAT) were all evaluated. Direct costs incurred due to Chem8+ and Troponin cartridge waste and indirect costs as avoidable nursing staff labor were estimated over 2 years. RESULTS: A total of 935 erroneous results were identified (6.0% of all cartridges). Three hundred seventy-two (2.4%) were unusable results, and 563 (3.6%) were cartridge errors, of which 163 were classified by device error codes as poor sample quality/improper sample handling. Error rates were inversely correlated with user experience based on number of tests performed during the 9-month period. Compared to nonerroneous results, test TATs and LOS were significantly longer with erroneous results (P < 0.01). Over 2 years, direct costs incurred due to cartridge waste was $45 000, and indirect cost was estimated between 486 and 729 h in avoidable nursing labor. CONCLUSIONS: Preanalytical POCT errors were inversely correlated with user experience and significantly impacted clinical productivity in the ED based on LOS and test TAT.


Assuntos
Testes Imediatos , Troponina , Serviço Hospitalar de Emergência , Humanos , Tempo de Internação , Estudos Retrospectivos , Estados Unidos
4.
J Diabetes Sci Technol ; 16(4): 976-981, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33729032

RESUMO

C-peptide is co-secreted with insulin and is not subject to hepatic clearance and thus reflects functional ß-cell mass. Assessment of C-peptide levels can identify individuals at risk for or with type 1 diabetes with residual ß-cell function in whom ß cell-sparing interventions can be evaluated, and can aid in distinguishing type 2 diabetes from Latent Autoimmune Diabetes in Adults and late-onset type 1 diabetes. To facilitate C-peptide testing, we describe a quantitative point-of-care C-peptide test. C-peptide levels as low as 0.2 ng/ml were measurable in a fingerstick sample, and the test was accurate over a range of 0.17 to 12.0 ng/ml. This test exhibited a correlation of r = 0.98 with a high-sensitivity commercial ELISA assay and a correlation of r = 0.90 between matched serum and fingerstick samples.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Autoanticorpos , Peptídeo C , Diabetes Mellitus Tipo 2/diagnóstico , Glutamato Descarboxilase , Humanos , Testes Imediatos
6.
Open Forum Infect Dis ; 8(3): ofab061, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33723513

RESUMO

BACKGROUND: Serological confirmation of coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical for understanding the dynamics of the pandemic and determining seroprevalence rates within afflicted communities. Common challenges with SARS-CoV-2 serological assays include poor analytical specificity and sensitivity and lack of a serological standard for quantitative assessment of antibody titers. METHODS: To overcome these obstacles, we developed a quantitative enzyme-linked immunosorbent assay based on an optimized 2-dimensional screening assay that utilizes SARS-CoV-2 receptor binding domain (RBD) of spike protein and SARS-CoV-2 spike S1 subunit. RESULTS: A total of 4 SARS-CoV-2-reactive monoclonal antibodies were evaluated for use as serum standards for calibrating assays performed on different days or by different laboratories. This approach provided quantitative analysis of hospitalized reverse transcription polymerase chain reaction-confirmed COVID-19 cases that in some cases reached >100 µg/mL. The assay demonstrated 72% sensitivity based on time points ranging from 2 to 52 days post-symptom onset, with 100% sensitivity at time points measured ≥13 days post-symptom onset and 100% specificity. CONCLUSIONS: Using these optimized reagents and serological standards, we believe this approach will be useful for sensitive and specific determination of seroconversion rates and quantitatively measuring the durability of antiviral antibody responses following SARS-CoV-2 infection or vaccination.

7.
Pediatr Res ; 90(4): 861-868, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33469174

RESUMO

BACKGROUND: Information on cannabinoids in breast milk and maternal cannabis use is limited. We quantified cannabinoids in plasma and breast milk of breastfeeding mothers and assessed cannabis use patterns. METHODS: This is a prospective study at a university hospital in a state with legal medical and recreational cannabis. Breast milk and plasma samples along with survey data were collected from volunteers using cannabis in the last 48 h at 2 weeks and 2 months postpartum. RESULTS: Twenty subjects were enrolled. Median age (IQR) was 27 (24-34) years. Median (IQR) instances of cannabis use in the last 7 days were visit 1: 17 (6-29) and visit 2: 23 (15-45). Median (IQR) tetrahydrocannabinol (THC) concentrations were: plasma 3.7 ng/ml (0.8-56.8) and breast milk 27.5 ng/ml (0.8-190.5). Median (IQR) cannabidiol (CBD) concentrations were: plasma 0.6 ng/ml (0.5-6.4) and breast milk 1.2 ng/ml (0.5-17.0). Median (IQR) THC M/P: 7.0 (1.8-34.6) and CBD M/P: 2.6. Median breast milk THC concentration increased from visit 1 to visit 2 by 30.2 ng/ml (95% CI 3.05-69.3 ng/ml). CONCLUSIONS: THC and CBD accumulate in breast milk. Breastfeeding mothers used cannabis frequently and increased use in the early postpartum period. Research on the effects of infant exposure to cannabinoids in breast milk is urgently needed. IMPACT: Cannabis use is increasing in the general population and many nursing mothers use cannabis. THC has been previously detected in breast milk but little is known on how it concentrates relative to plasma. Data on cannabinoids other than THC, reasons for cannabis use, and patterns of use in breastfeeding women are also limited. We detected THC and CBD in breast milk. Both concentrate in breast milk relative to plasma. We showed that breastfeeding mothers increased cannabis use in the weeks after childbirth. Further research is needed to evaluate infant exposure to cannabinoids via breast milk and effects on infant health.


Assuntos
Aleitamento Materno , Canabinoides/análise , Cannabis , Leite Humano/química , Mães , Adulto , Canabinoides/sangue , Feminino , Humanos , Recém-Nascido , Estudos Prospectivos
8.
J Appl Lab Med ; 5(2): 332-341, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32445387

RESUMO

BACKGROUND: Point-of-care (POC) testing is an integral diagnostic component in clinical settings like the emergency department (ED). However, most POC testing devices are unable to detect endogenous interferents such as hemolysis, which typically occurs during sample collection and handling and can falsely increase measured potassium (pseudohyperkalemia), a phenomenon we hypothesized may significantly impact patient care. METHODS: In this retrospective study, we evaluated 100 unique admissions to the Oregon Health & Science University ED, presenting with elevated potassium measured at the POC. To evaluate whether in vitro hemolysis had occurred, POC test results were compared to repeat testing of the original specimen, or other specimens tested within 90 minutes in the Core laboratory. Review of associated Electronic Health Records determined whether elevated potassium initially measured using the POC analyzer was real, or due to in vitro hemolysis or contamination, and whether pseudohyperkalemia impacted patient management or care. RESULTS: Of the 100 admissions with hyperkalemia measured using a POC analyzer, 40% were found to have pseudohyperkalemia due to hemolysis or contamination. Of these 40 patients, 6 experienced repeated testing, and an additional 5 were noted to have altered patient management, specifically due to pseudohyperkalemia. CONCLUSIONS: This study demonstrates the incidence of in vitro hemolysis, which is unknown to the POC operator, is high in patients who show an elevated potassium as measured at the POC. Furthermore, in vitro hemolysis can significantly impact patient management, suggesting that minimizing the incidence of unrecognized hemolysis will benefit hospital efficiency, decrease waste, and improve patient care.


Assuntos
Análise Química do Sangue/normas , Hemólise , Assistência ao Paciente/normas , Sistemas Automatizados de Assistência Junto ao Leito/normas , Testes Imediatos/normas , Análise Química do Sangue/métodos , Coleta de Amostras Sanguíneas/normas , Feminino , Humanos , Hiperpotassemia/sangue , Hiperpotassemia/diagnóstico , Hiperpotassemia/etiologia , Masculino , Assistência ao Paciente/métodos , Potássio/sangue , Estudos Retrospectivos
9.
Clin Chem ; 63(4): 815, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28351856
10.
Sci Rep ; 6: 34513, 2016 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-27694829

RESUMO

cAMP-response element binding protein (CREB) is a nuclear transcription factor activated by multiple extracellular signals including growth factors and hormones. These extracellular cues activate CREB through phosphorylation at Ser133 by various protein serine/threonine kinases. Once phosphorylated, it promotes its association with transcription coactivators CREB-binding protein (CBP) and its paralog p300 to activate CREB-dependent gene transcription. Tumor tissues of different origins have been shown to present overexpression and/or overactivation of CREB, indicating CREB as a potential cancer drug target. We previously identified 666-15 as a potent inhibitor of CREB with efficacious anti-cancer activity both in vitro and in vivo. Herein, we investigated the specificity of 666-15 and evaluated its potential in vivo toxicity. We found that 666-15 was fairly selective in inhibiting CREB. 666-15 was also found to be readily bioavailable to achieve pharmacologically relevant concentrations for CREB inhibition. Furthermore, the mice treated with 666-15 showed no evidence of changes in body weight, complete blood count, blood chemistry profile, cardiac contractility and tissue histologies from liver, kidney and heart. For the first time, these results demonstrate that pharmacological inhibition of CREB is well-tolerated in vivo and indicate that such inhibitors should be promising cancer therapeutics.


Assuntos
Anilidas , Antineoplásicos , Proteína de Ligação ao Elemento de Resposta ao AMP Cíclico/antagonistas & inibidores , Naftalenos , Proteínas de Neoplasias/antagonistas & inibidores , Neoplasias/tratamento farmacológico , Anilidas/efeitos adversos , Anilidas/farmacocinética , Anilidas/farmacologia , Animais , Antineoplásicos/administração & dosagem , Antineoplásicos/farmacocinética , Antineoplásicos/farmacologia , Ensaios de Seleção de Medicamentos Antitumorais , Feminino , Células HEK293 , Humanos , Camundongos , Naftalenos/efeitos adversos , Naftalenos/farmacocinética , Naftalenos/farmacologia , Proteínas de Neoplasias/metabolismo , Neoplasias/metabolismo , Neoplasias/patologia
11.
Nanomedicine (Lond) ; 10(16): 2527-36, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26295965

RESUMO

AIM: Alumina nanowell based disposable diagnostic biosensor for detecting and quantifying levels of prostate-specific antigen (PSA) from human serum has been designed, fabricated and tested. MATERIALS & METHODS: The biosensors were designed by integrating nanoporous alumina membranes onto printed circuit board platforms, resulting in the generation of high-density nanowell arrays with gold base electrodes. The size and density of the nanowells were leveraged toward achieving sieving action for size-based exclusion of nonspecific molecules and size-based confinement of the target PSA molecules. RESULTS & CONCLUSION: We demonstrated PSA detection between 0.01 and 1000 ng/ml and detection and quantification of PSA from a 17 patient cohort validated using the Beckman Access system with >95% correlation.


Assuntos
Técnicas Biossensoriais , Nanotecnologia , Antígeno Prostático Específico/análise , Humanos , Limite de Detecção , Masculino
12.
Clin Chim Acta ; 442: 96-101, 2015 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-25619774

RESUMO

BACKGROUND: Troponin is the preferred biomarker for diagnosing myocardial infarction. Point of care devices have not matched the sensitivity of laboratory-based methods for measuring troponin. The Nanomonitor is a novel point-of-care device that uses the change in electrical impedance that occurs when a biomarker binds to its antibody, which is then correlated to the concentration of the target biomarker. METHODS: Performance characteristics of the Nanomonitor were evaluated and compared to a standard laboratory-based method. RESULTS: The limit of detection of the Nanomonior for troponin T was 0.0088ng/l. Total imprecission was 2.38% and 0.85% at troponin T concentrations of 73ng/l and 1800ng/l. The functional sensitivity (10% coeffecient of variation) was 0.329ng/l. The linear regression had a slope of 0.996 (95% confidence interval, 0.991, 1.002), r=1.00, and an intercept of 15.88ng/l (95% confidence interval, -68.39ng/l, 100.15ng/l). The mean difference between the assays was -7.54ng/l, determined by Bland-Altman analysis. CONCLUSION: The Nanomonitor preliminary results have favorable performance characteristics for detecting troponin T in patient blood, provide results in 15min, and are portable. More research is needed.


Assuntos
Análise Química do Sangue/métodos , Limite de Detecção , Nanotecnologia/métodos , Troponina T/sangue , Humanos
13.
Future Sci OA ; 1(3): FSO24, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28031897

RESUMO

AIM: To demonstrate the design, fabrication and testing of a portable, label-free biosensor for ultrasensitive detection of the cardiac Troponin-T (cTnT) from patient blood. MATERIALS & METHODS: The biosensor is comprised of a nanoporous membrane integrated on to a microelectrode sensor platform for nanoconfinement effects. Charge perturbations due to antigen binding are recorded as impedance changes using electrochemical impedance spectroscopy. RESULTS: The measured impedance change is used to quantitatively determine the cTnT concentration from the tested sample. We were successful in detecting and quantifying cardiac Troponin-T from a 40-patient cohort. The limit of detection was 0.01 pg/ml. CONCLUSION: This novel technology has promising preliminary results for rapid and sensitive detection of cTnT.

14.
Clin Chem Lab Med ; 51(9): 1875-82, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23648634

RESUMO

BACKGROUND: Although a variety of biochemical markers are used to help predict the risk of cardiovascular disease, the prognostic utility of any marker used as a risk assessment tool is dependent on the long- and short-term biological variability that the marker shows in different individuals. METHODS: We measured total, low-density lipoprotein (LDL), and high-density lipoprotein (HDL) cholesterol; triglycerides; high-sensitivity C-reactive protein (hsCRP); total fibrinogen; and γ' fibrinogen in blood samples collected from 15 apparently healthy individuals over the course of 1 year. Repeated measures variation estimates were used to calculate short- and long-term intraclass correlation coefficients (ICC), within- and between-subject coefficients of variation (CVI and CVG, respectively), validity coefficients, and indices of individuality for each marker. RESULTS: HDL cholesterol demonstrated the lowest variability profile, with an ICC of 0.84 and CVI of 11.1 (95% CI: 8.3, 17.0). hsCRP showed the highest levels of short- and long-term within-subject variability [CVI (95% CI): 54.8 (32.8, 196.3) and 77.1 (53.3, 141.3), respectively]. Stated differently, it would require five separate measurements of hsCRP, performed on samples collected over multiple days, to provide the risk assessment information provided by a single measurement of HDL cholesterol. γ' Fibrinogen demonstrated an ICC of 0.79 and CVI of 14.3 (95% CI: 10.6, 21.9). CONCLUSIONS: hsCRP showed very high biological variability, such that a single measurement of hsCRP lacks sufficient clinical utility to justify routine measurement. The variability profile of γ' fibrinogen was not markedly different than HDL cholesterol, necessitating only a limited number of measurements to establish an individual's risk of cardiovascular disease.


Assuntos
Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/diagnóstico , HDL-Colesterol/sangue , Lipoproteínas HDL/sangue , Adulto , Biomarcadores/sangue , Feminino , Humanos , Masculino , Prognóstico , Medição de Risco , Fatores de Risco
16.
Clin Chem Lab Med ; 51(1): 75-81, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23152419

RESUMO

Abstract The discipline of laboratory medicine is relatively young when considered in the context of the history of medicine itself. The history of quality control, within the context of laboratory medicine, also enjoys a relatively brief, but rich history. Laboratory quality control continues to evolve along with advances in automation, measurement techniques and information technology. Clinical Chemistry and Laboratory Medicine (CCLM) has played a key role in helping disseminate information about the proper use and utility of quality control. Publication of important advances in quality control techniques and dissemination of guidelines concerned with laboratory quality control has undoubtedly helped readers of this journal keep up to date on the most recent developments in this field.


Assuntos
Química Clínica/normas , Técnicas de Laboratório Clínico/normas , Medicina Clínica/normas , Publicações Periódicas como Assunto , Humanos , Controle de Qualidade
17.
Nanomedicine (Lond) ; 7(11): 1755-69, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23210715

RESUMO

Quantum dots (QDs) are semiconductor nanocrystals that possess unique optical properties including broad-range excitation, size-tunable narrow emission spectra and high photostability, giving them considerable value in various biomedical applications. The size and composition of QDs can be varied to obtain the desired emission properties and make them amenable to simultaneous detection of multiple targets. Furthermore, numerous surface functionalizations can be used to adapt QDs to the needed application. The successful use of QDs has been reported in the areas of in vitro diagnostics and imaging. There is also potential for multimodal applications for simultaneous imaging. Toxicity issues are still a prime concern with regards to in vivo applications on account of the toxic constituents of QDs.


Assuntos
Nanotecnologia/métodos , Pontos Quânticos , Animais , Humanos , Imunoensaio/métodos , Microscopia/métodos , Técnicas de Diagnóstico Molecular/métodos , Nanoconjugados/química , Oligonucleotídeos/química , Proteínas/química , Testes de Toxicidade
18.
Artigo em Inglês | MEDLINE | ID: mdl-23366487

RESUMO

Errors in clinical laboratory tests lead to increased costs and patient risks. Such errors are relatively rare, affecting ∼0.5% of samples. Existing techniques for detecting errors have either far too low sensitivity or specificity to be useful. This preliminary study develops statistical sample selection criteria that capture faults upwards of fifty times more efficiently than expected from random sampling. Although this is only the first step towards an integrated discriminant system for reliable detection of laboratory errors, the statistical detection scheme demonstrated here outperforms existing methods.


Assuntos
Técnicas de Laboratório Clínico/normas , Erros de Diagnóstico/estatística & dados numéricos , Humanos
20.
Clin Chem ; 56(5): 781-8, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20348406

RESUMO

BACKGROUND: Studies of disease associations with gamma' fibrinogen, a newly emerging risk factor for cardiovascular disease, have been hampered by the lack of a standardized and well-characterized assay. METHODS: We developed an immunometric technique to measure gamma' fibrinogen concentrations in plasma and studied the clinical utility of this test in samples from healthy individuals enrolled in the Framingham Offspring Study and in a separate case/control study of coronary artery disease (CAD). Monoclonal antibody 2.G2.H9, specific for the unique carboxyl terminal peptide of the fibrinogen gamma' chain, was used as capture antibody. Sheep antihuman fibrinogen/horseradish peroxidase conjugate was used for detection, with 3,3',5,5'-tetramethylbenzidine as substrate. We evaluated the linearity, imprecision, analytical specificity, and lower limit of quantification of the assay. We determined the reference interval for gamma' fibrinogen in healthy individuals from the Framingham Offspring Study (n = 2879) and quantified associations between gamma' fibrinogen and cardiovascular disease risk factors. The sensitivity and specificity of gamma' fibrinogen in evaluating CAD patients (n = 133) was determined with ROC curve analysis. RESULTS: The gamma' fibrinogen ELISA had within-run CVs of 13.4% at 0.127 g/L and 4.8% at 0.416 g/L. The limit of quantification at an imprecision of 20% was 0.10 g/L. The reference interval for healthy individuals was 0.088-0.551 g/L. ROC curve analysis of results from patients with CAD yielded an area under the curve of 0.76, with a diagnostic accuracy of 0.78 at a decision threshold of 0.30 g/L. CONCLUSIONS: gamma' Fibrinogen shows excellent utility for cardiovascular risk analysis.


Assuntos
Doenças Cardiovasculares/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Fibrinogênio/análise , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais/imunologia , Doenças Cardiovasculares/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico , Feminino , Fibrinogênio/imunologia , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Curva ROC , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...