Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Anal Methods ; 14(34): 3355, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35997282

RESUMO

Correction for 'Novel 90Sr analysis of environmental samples by Ion-Laser InterAction Mass Spectrometry' by Maki Honda et al., Anal. Methods, 2022, 14, 2732-2738, https://doi.org/10.1039/D2AY00604A.

2.
Anal Methods ; 14(28): 2732-2738, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35789229

RESUMO

The sensitive analysis of 90Sr with accelerator mass spectrometry (AMS) was developed to advance environmental radiology. One advantage of AMS is the ability to analyze environmental samples with 90Sr/88Sr atomic ratios of 10-14 in following a simple chemical separation. Three different IAEA samples with known 90Sr concentrations (moss-soil, animal bone, Syrian soil: 1 g each) were analyzed to assess the validity of the chemical separation and the AMS measurement. The 90Sr measurements were conducted on the AMS system VERA combined with the Ion Laser InterAction Mass Spectrometry (ILIAMS) setup at the University of Vienna, which has excellent isobaric separation performance. The isobaric interference of 90Zr in the 90Sr AMS was first largely removed by chemical separation. The separation factor of Zr in two-step column chromatography with Sr resin and anion exchange resin was 106. The 90Zr remaining in the sample was effectively suppressed by ILIAMS. This procedure achieved a limit of detection <0.1 mBq in the 90Sr AMS, which is lower than typical ß-ray detection. The agreement between AMS measurements and nominal values for the 90Sr concentrations of IAEA samples indicated that the new highly-sensitive 90Sr analysis in the environmental samples with AMS is reliable.


Assuntos
Solo , Radioisótopos de Estrôncio , Animais , Lasers , Espectrometria de Massas/métodos , Radioisótopos de Estrôncio/análise
3.
Neurointervention ; : 84-88, 2020.
Artigo | WPRIM (Pacífico Ocidental) | ID: wpr-837027

RESUMO

We herein report a case of a ruptured vertebral artery dissecting aneurysm involving the origin of the posterior inferior cerebellar artery that was treated using the stent-jack technique. After parent artery occlusion of the distal vertebral artery, stenting of the posterior inferior cerebellar artery was performed. Further coiling was needed because distal vertebral artery recanalization occurred due to transformation of the coil mass. The stent-jack technique for a ruptured vertebral artery dissecting aneurysm involving the origin of the posterior inferior cerebellar artery is effective; however, careful attention to recanalization after stenting is needed due to transformation of the coil mass.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...