1.
Opt Express ; 12(2): 269-75, 2004 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-19471533

RESUMO

A low polarization dependent, high diffraction efficiency grating for wavelength demultiplexer is proposed, manufactured by standard crystallographic etching of Si surface. Light is incident and diffracted inside the wafer, which is covered with reflecting metal. Optimized groove form results in a flat spectral response for TE and TM polarizations.

2.
J Nucl Med ; 28(3): 372-7, 1987 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3546626

RESUMO

We have compared several techniques for measuring [99mTc]DTPA plasma clearance following single injection to estimate glomerular filtration rate (GFR). Half hourly measurements of disappearance of plasma activity were used to calculate a reference GFR corrected for one-pool assumption and body surface area. Alternative methods involving (i) single blood sample, (ii) two blood samples, (iii) external detector clearance rate, and (iv) a combination of (i) and (iii) were then compared. Closest correlations were obtained with (i) two blood samples at 2 hr and 4 hr (s.e.e. 2.8 ml/min) and (i.v.) external rate constant from 2-5 hr with a blood sample at 3 hr (s.e.e. 3.0 ml/min). Correlations with single blood sample were closest at 3 hr and 4 hr postinjection (s.e.e. 5.4 and 4.5 ml/min, respectively). External detector disappearance rate constant alone was least accurate (s.e.e. greater than 10 ml. min).


Assuntos
Taxa de Filtração Glomerular , Ácido Pentético , Renografia por Radioisótopo/métodos , Tecnécio , Humanos , Cinética , Matemática , Taxa de Depuração Metabólica , Ácido Pentético/sangue , Tecnécio/sangue , Pentetato de Tecnécio Tc 99m , Fatores de Tempo
3.
Eur J Nucl Med ; 13(5): 250-3, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3311766

RESUMO

A comparison has been made between three gamma camera methods for estimation of glomerular filtration rate (GFR) using 99mTc-DTPA in a group of 27 patients with widely different renal function. Plasma clearance of 99mTc-DTPA by multiple blood sampling was used as the reference. Percentage uptake of chelate in the bladder and kidneys at 20 min after injection gave the lowest standard error of 8.0 ml/min. Techniques using early uptake of isotope in the kidneys at 2 min after injection gave less accurate estimates. Correction for the vascular activity in the renal region of interest improved the results for the 2 min uptake technique. Gamma camera techniques provide rapid estimates of GFR which are less accurate than those obtained by plasma clearance of labelled chelate.


Assuntos
Taxa de Filtração Glomerular , Nefropatias/diagnóstico por imagem , Compostos Organometálicos , Ácido Pentético , Humanos , Testes de Função Renal , Cintilografia , Pentetato de Tecnécio Tc 99m
4.
Lab Anim ; 19(3): 258-61, 1985 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3162061

RESUMO

PVC isolators are now widely used for housing animals and provide a readily available pretested air-tight chamber (Pendry, 1984; Trexler, 1984). We have adapted a flexible film isolator for use as a hypoxic chamber for small animals. The environment within the chamber can be easily and continuously monitored with indwelling probes, obviating the need for a separate circuit for gas analysis. This design has been used for long-term studies of chronic hypoxia.


Assuntos
Câmaras de Exposição Atmosférica , Ambiente Controlado , Hipóxia/veterinária , Ratos , Doenças dos Roedores/fisiopatologia , Animais , Cardiomegalia/veterinária , Hipertensão Pulmonar/veterinária , Hipóxia/fisiopatologia , Policitemia/veterinária , Ratos Endogâmicos