Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Cardiovasc Intervent Radiol ; 42(3): 460-465, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30603971

RESUMO

PURPOSE: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. MATERIALS AND METHODS: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. RESULTS: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6-8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 µGym2, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. CONCLUSION: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Procedimentos Endovasculares/métodos , Veia Femoral , Diálise Renal/métodos , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
Diagn Interv Imaging ; 98(10): 729-735, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28233711

RESUMO

PURPOSE: The purpose of this study was to characterize the hemodynamics of peripheral artery stent grafts to guide intelligent stent redesign. MATERIALS AND METHODS: Two surgically explanted porcine arteries were mounted in an ex vivo system with subsequent deployment of an Xpert self-expanding nitinol stent or Viabahn stent graft. The arteries were casted with radiopaque resin, and the cast then scanned using micro-computed tomography at 8µm isotropic voxel resolution. The arterial lumen was segmented and a computational mesh grid surface generated. Computational fluid dynamics (CFD) analysis was subsequently performed using COMSOL Multiphysics 5.1. RESULTS: CFD analysis demonstrated low endothelial shear stress (ESS) involving 9.4 and 63.6% surface area of the central stent graft and bare metal stent, respectively. Recirculation zones were identified adjacent to the bare metal stent struts, while none were identified in the central stent graft. However, the stent graft demonstrated malapposition of the proximal stent graft edge with low velocity flow between the PTFE lining and arterial wall, which was associated with longitudinally and radially oriented recirculation zones and low ESS. CONCLUSION: Computational hemodynamic analysis demonstrates that peripheral artery stent grafts have a superior central hemodynamic profile compared to bare metal stents. Stents grafts, however, suffer from malapposition at the proximal stent edge which is likely a major contributor to edge stenosis.


Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Stents Metálicos Autoexpansíveis , Stents , Ligas , Animais , Materiais Revestidos Biocompatíveis , Hemodinâmica , Modelos Animais , Politetrafluoretileno , Suínos , Microtomografia por Raio-X
3.
AJNR Am J Neuroradiol ; 29(5): 1024-31, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18339725

RESUMO

BACKGROUND AND PURPOSE: Patients with arteriovenous malformation (AVM) are known to have an elevated risk of complications with conventional catheter angiography (CCA) but nonetheless require monitoring of hemodynamics. Thus, we aimed to evaluate both anatomy and hemodynamics in patients with AVM noninvasively by using contrast-enhanced MR angiography (CE-MRA) at 3T and to compare the results with CCA. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant study. Twenty control subjects without vascular malformation (6 men, 18-70 years of age) and 10 patients with AVMs (6 men, 20-74 years of age) underwent supra-aortic time-resolved and high-spatial-resolution CE-MRA at 3T. Large-field-of-view coronal acquisitions extending from the root of the aorta to the cranial vertex were obtained for both MRA techniques. Image quality was assessed by 2 specialized radiologists by using a 4-point scale. AVM characteristics and nidus size were evaluated by using both CE-MRA and CCA in all patients. RESULTS: In patients, 96.6% (319/330) of arterial segments on high-spatial-resolution MRA and 87.7% (272/310) of arterial segments on time-resolved MRA were graded excellent/good. MRA showed 100% specificity for detecting feeding arteries and venous drainage (n = 8) and complete obliteration of the AVM in 2 cases (concordance with CCA). Nidus diameters measured by both MRA and CCA resulted in a very strong correlation (r = 0.99) with a mild overestimation by MRA (0.10 cm by using the Bland-Altman plot). CONCLUSION: By combining highly temporally resolved and highly spatially resolved MRA at 3T as complementary studies, one can assess vascular anatomy and hemodynamics noninvasively in patients with AVM.


Assuntos
Gadolínio DTPA/uso terapêutico , Aumento da Imagem/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Artéria Vertebral/anormalidades , Artéria Vertebral/patologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Radiology ; 218(2): 527-32, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11161174

RESUMO

PURPOSE: To compare observer performance in the detection of abnormalities on 1,760 x 2,140 matrix (2K) and 3,520 x 4,280 matrix (4K) digital storage phosphor chest radiographs. MATERIALS AND METHODS: One hundred sixty patients who underwent dedicated computed tomography (CT) of the thorax were prospectively recruited into the study. Posteroanterior and lateral computed radiographs of the chest were acquired in each patient and printed in 2K and 4K formats. Six radiologists independently analyzed the hard-copy images and scored the presence of parenchymal (opacities 2 cm, and subtle interstitial), mediastinal, and pleural abnormalities on a five-point confidence scale. With CT as the reference standard, observer performance tests were carried out by using receiver operating characteristic (ROC) analysis. RESULTS: Analysis of averaged observer performance showed 2K and 4K images were equally effective in detection of all three groups of abnormalities. In the detection of the three subtypes of parenchymal abnormalities, there were no significant differences in averaged performance between the 2K and 4K formats (area below ROC curve [A(z)] values: opacities 2 cm, 0.86 +/-.025 and 0.85 +/- 0.030; subtle interstitial abnormalities, 0.73 +/- 0.041 and 0.72 +/- 0.041). Averaged performance in detection of mediastinal and pleural abnormalities was equivalent (A(z) values: mediastinal, 0.70 +/- 0.046 and 0.73 +/- 0.033; pleural, 0.85 +/- 0.032 and 0.86 +/- 0.033). CONCLUSION: Observer performance in detection of parenchymal, mediastinal, and pleural abnormalities was not significantly different on 2K and 4K storage phosphor chest radiographs.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Torácica , Tomografia Computadorizada por Raios X , Feminino , Humanos , Pneumopatias/diagnóstico por imagem , Masculino , Doenças do Mediastino/diagnóstico por imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doenças Pleurais/diagnóstico por imagem , Curva ROC , Radiografia Torácica/métodos , Radiografia Torácica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
5.
Acad Radiol ; 8(12): 1200-7, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11770916

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to provide in vivo demonstrations of the functionality of a truly hybrid interventional x-ray/magnetic resonance (MR) system. MATERIALS AND METHODS: A digital flat-panel x-ray system (1,024(2) array of 200 microm pixels, 30 frames per second) was integrated into an interventional 0.5-T magnet. The hybrid system is capable of MR and x-ray imaging of the same field of view without patient movement. Two intravascular procedures were performed in a 22-kg porcine model: placement of a transjugular intrahepatic portosystemic shunt (TIPS) (x-ray-guided catheterization of the hepatic vein, MR fluoroscopy-guided portal puncture, and x-ray-guided stent placement) and mock chemoembolization (x-ray-guided subselective catheterization of a renal artery branch and MR evaluation of perfused volume). RESULTS: The resolution and frame rate of the x-ray fluoroscopy images were sufficient to visualize and place devices, including nitinol guidewires (0.016-0.035-inch diameter) and stents and a 2.3-F catheter. Fifth-order branches of the renal artery could be seen. The quality of both real-time (3.5 frames per second) and standard MR images was not affected by the x-ray system. During MR-guided TIPS placement, the trocar and the portal vein could be easily visualized, allowing successful puncture from hepatic to portal vein. CONCLUSION: Switching back and forth between x-ray and MR imaging modalities without requiring movement of the patient was demonstrated. The integrated nature of the system could be especially beneficial when x-ray and MR image guidance are used iteratively.


Assuntos
Quimioembolização Terapêutica , Imageamento por Ressonância Magnética/instrumentação , Derivação Portossistêmica Transjugular Intra-Hepática , Radiologia Intervencionista/instrumentação , Animais , Desenho de Equipamento , Fluoroscopia/instrumentação , Neoplasias Renais/terapia , Modelos Animais , Suínos
6.
J Vasc Interv Radiol ; 11(7): 823-36, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10928517

RESUMO

PURPOSE: To evaluate the feasibility of endovascular techniques in treating venous outflow obstruction resulting from compression of the iliac vein by the iliac artery of the left lower extremity (May-Thurner syndrome). MATERIALS AND METHODS: A retrospective analysis of 39 patients (29 women, 10 men; median age, 46 years) with iliac vein compression syndrome (IVCS) was performed. Nineteen patients presented with acute deep vein thrombosis (DVT) and 20 patients presented with chronic symptoms. All patients presented with leg edema or pain. In the acute group, patients were treated with catheter-directed thrombolysis (120,000-180,000 IU urokinase/h) and angioplasty followed by stent placement. In the chronic group, patients were treated with use of angioplasty and stent placement alone (n = 8), or in combination with thrombolysis (n = 12). Patients were then followed-up with duplex ultrasound and a quality-of-life assessment. RESULTS: Initial technical success was achieved in 34 of 39 patients (87%). The overall patency rate at 1 year was 79%. Symptomatically, 85% of patients were completely or partially improved compared with findings before treatment. Thirty-five of 39 patients received stents. The 1-year patency rate for patients with acute symptoms who received stents was 91.6%; for patients with chronic symptoms who received stents, the 1-year patency rate was 93.9%. Five technical failures occurred. Major complications included acute iliac vein rethrombosis (< 24 hours) requiring reintervention (n = 2). Minor complications included perisheath hematomas (n = 4) and minor bleeding (n = 1). There were no deaths, pulmonary embolus, cerebral hemorrhage, or major bleeding complications. CONCLUSION: Endovascular reconstruction of occluded iliac veins secondary to IVCS (May-Thurner) appears to be safe and effective.


Assuntos
Veia Ilíaca , Doenças Vasculares Periféricas/terapia , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia , Cateterismo Periférico/instrumentação , Doença Crônica , Terapia Combinada , Constrição Patológica/terapia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ativadores de Plasminogênio/uso terapêutico , Qualidade de Vida , Estudos Retrospectivos , Stents , Síndrome , Terapia Trombolítica , Ultrassonografia Doppler Dupla , Ativador de Plasminogênio Tipo Uroquinase/uso terapêutico , Grau de Desobstrução Vascular , Trombose Venosa/terapia
7.
J Vasc Interv Radiol ; 11(5): 578-84, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10834488

RESUMO

PURPOSE: To evaluate the potential of covered stents to replace surgery in the treatment of subclavian artery aneurysms and traumatic injuries. MATERIALS AND METHODS: Nine patients (five men, four women; age range, 20-83 years; mean, 54 years) with subclavian artery aneurysms (n = 5) or fistulas (n = 4) were treated with stent-grafts. All devices used were custom-made, consisting of polytetrafluoroethylene (PTFE)-covered Palmaz (n = 5), Wallstent (n = 2), Z stents (n = 8), or a polyester-covered Z stent (n = 1). One patient was lost to follow-up after 2 months. All others were followed up with clinical evaluation, computed tomography (CT), and/or ultrasound. RESULTS: All devices were deployed successfully with exclusion of the aneurysms and fistulas. There were two procedure-related complications (22%), consisting of groin pseudoaneurysms requiring surgical repair 3 and 9 days after the procedure. One of those patients required additional oral antibiotic therapy for a postsurgical groin wound infection. One patient developed a stenosis at 12 months, which required angioplasty. The stent-graft thrombosed in one patient because of a kink 2 months after placement, which was successfully treated by thrombolysis and placement of a Wallstent. The primary and secondary patencies are 89% and 100%, respectively, after a mean follow-up of 29 months (2-66 mo). CONCLUSION: Mid-term results of stent-graft therapy of subclavian artery aneurysms and fistulas are encouraging, with low morbidity and excellent clinical outcome.


Assuntos
Aneurisma/cirurgia , Fístula Arteriovenosa/cirurgia , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Artéria Subclávia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Polímeros de Fluorcarboneto , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Poliésteres , Artéria Subclávia/anormalidades , Artéria Subclávia/lesões , Resultado do Tratamento
8.
Radiology ; 215(3): 670-6, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10831682

RESUMO

PURPOSE: To compare single- versus four-channel helical computed tomographic (CT) aortography. MATERIALS AND METHODS: Forty-eight patients with aortic aneurysm or dissection underwent four- and one-channel CT angiography. Scan pairs covered the thoracic inlet to the diaphragm (n = 10) and supraceliac abdominal aorta (n = 19) or thoracic inlet (n = 19) to the femoral arterial bifurcations. For four-channel CT, nominal section thickness and pitch were 2.5 mm and 6.0, respectively, and for one-channel CT, 3.0 mm and 2.0 to the infrarenal aorta and 5.0 mm and 2.0 to the femoral arteries. Effective section thickness, scanning duration, scanning coverage, dose of iodinated contrast material, and mean aortoiliac attenuation were compared. Data were summarized as speed (coverage/duration), scanning efficiency (speed/section thickness), and contrast efficiency (mean aortic attenuation/dose of contrast material). RESULTS: At four- versus one-channel CT, CT angiography was 2.6 times faster, scanning efficiency was 4.1 times greater, contrast efficiency was 2.5 times greater, dose of contrast material was reduced (mean, 57%; 97 vs 232 mL) without a significant change in aortic enhancement, and sections were thinner (mean, 40%; 3.2 vs 5.3 mm) despite a 59% shorter scanning duration (22 vs 56 seconds). CONCLUSION: Substantially reduced doses of contrast medium, shorter scanning durations, and narrower effective sections result with four- versus one-channel CT aortography. No advantages of one-channel CT aortography were demonstrated.


Assuntos
Aortografia/métodos , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Dissecção Aórtica/diagnóstico por imagem , Aorta Abdominal/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/instrumentação , Aortografia/estatística & dados numéricos , Meios de Contraste , Seguimentos , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/estatística & dados numéricos
9.
Radiology ; 214(1): 133-8, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10644112

RESUMO

PURPOSE: To report the results of endoluminal recanalization and stent placement in patients with chronic occlusions of the inferior vena cava (IVC). MATERIALS AND METHODS: Seventeen consecutive patients (12 male, five female patients; mean age, 40.6 years; age range, 15-77 years) with chronic IVC occlusions were treated during a 6-year period. The mean duration of symptoms was 32 months. Underlying active malignancy was the cause of occlusion in four patients. Five patients with superimposed acute thrombus underwent catheter-directed thrombolysis prior to IVC recanalization. Clinical patency was defined as absence or improvement of symptoms. Clinical follow-up was supplemented with ultrasonography, vena cavography, or both in 10 patients. RESULTS: Technical success was achieved in 15 (88%) patients. Additional thrombolytic therapy and stent placement was needed in two patients to maintain patency at 4 and 6 months after the procedure. Twelve patients had IVCs that remained patent after a mean follow-up of 19 months for a primary patency rate of 80%. The primary assisted patency rate was 87% (13 of 15). There were four deaths owing to underlying disease 6-21 months after the procedures. There were no procedure-related complications. CONCLUSION: Endoluminal recanalization and stent placement in chronically occluded IVCs has a good intermediate-term outcome and should be considered in patients who have symptoms and who often do not have adequate alternative therapy.


Assuntos
Angioplastia com Balão/instrumentação , Stents , Trombose/terapia , Veia Cava Inferior , Adolescente , Adulto , Idoso , Angiografia Digital , Doença Crônica , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Constrição Patológica/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Trombose/diagnóstico por imagem , Trombose/etiologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem
10.
J Vasc Interv Radiol ; 10(10): 1323-9, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10584646

RESUMO

PURPOSE: To compare diagnostic yield and complication rates of magnetic resonance (MR)-guided versus computed tomography (CT)- and ultrasound (US)-guided liver biopsies. MATERIALS AND METHODS: MR-, CT-, and US-guided liver biopsies performed between 9/96 and 9/98 were compared. Sixty patients (21 men and 39 women, mean age 60 years) underwent MR-guided biopsy of liver lesions. Thirty patients (16 men and 14 women, mean age 59 years) underwent CT-guided biopsy. Eighteen patients (seven men and 11 women, mean age 50 years) underwent US-guided biopsy. MR procedures were performed in an open-configuration 0.5-T Signa SP MR unit. Lesion localization used standard T1 and T2 sequences, whereas biopsies were performed with multiplanar spoiled gradient recalled echo and fast gradient recalled echo sequences. A coaxial system with an MR-compatible 18-gauge stabilizing needle and a 21-gauge aspiration needle was used to obtain all samples. In CT and US procedures, a 19-gauge stabilizing needle and a 21-gauge aspiration or a 20-gauge core biopsy needle were used. A cytotechnologist was present to determine the adequacy of samples. RESULTS: MR had a diagnostic yield of 61%. CT and US had diagnostic yields of 67% and 61%, respectively. No serious complications were reported for MR and US procedures. Two CT biopsies resulted in postprocedural hemorrhage. One patient required surgical exploration and died. CONCLUSIONS: MR-guided biopsy of liver lesions with use of a 0.5-T open-configuration magnet is safe and accurate when compared with CT and US. No statistical difference was observed between the diagnostic yield of biopsies performed with MR, CT, and US guidance. MR enabled biopsy of a number of lesions in the hepatic dome and lesions with low contrast, which would normally be difficult to sample safely with use of CT or US.


Assuntos
Biópsia por Agulha/métodos , Neoplasias Hepáticas/patologia , Fígado/patologia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Ultrassonografia , Diagnóstico Diferencial , Erros de Diagnóstico , Feminino , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
Chest ; 116(3): 825-7, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10492294

RESUMO

Airway complications of relapsing polychondritis (RP), including tracheobronchial stenosis, can be fatal. This paper describes a life-saving technique (placement of multiple metallic endobronchial stents under conscious sedation) to prevent life-threatening airway closure in a 50-year-old woman with RP. Using fluoroscopic and bronchoscopic guidance, a tracheal stent and three endobronchial metallic stents were deployed in the central airways, with good functional outcome. There were no complications. In critical airway compromise caused by RP, the insertion of endobronchial stents can result in improved symptoms, pulmonary function, and a return to daily activities, without the use of tracheotomy and mechanical ventilation.


Assuntos
Obstrução das Vias Respiratórias/terapia , Brônquios , Policondrite Recidivante/complicações , Stents , Traqueia , Obstrução das Vias Respiratórias/etiologia , Feminino , Humanos , Pessoa de Meia-Idade
12.
J Vasc Interv Radiol ; 10(7): 851-9, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10435701

RESUMO

PURPOSE: To report experience with techniques for management of misplaced or migrated endovascular stents. MATERIALS AND METHODS: During a 5-year period, percutaneous management of 27 misplaced or migrated endovascular stents (16 Palmaz, 11 Wallstents) in 25 patients was attempted. The 17 venous and 10 arterial stents were rescued from the aorta (n = 9), inferior vena cava (IVC) (n = 4), transjugular intrahepatic portosystemic shunt/IVC (n = 2), right atrium (n = 3), right ventricle (n = 2), pulmonary artery (n = 2), iliac vein (n = 2), iliac artery (n = 1), superior vena cava (n = 1), and superior mesenteric vein (n = 1). RESULTS: Stent management was successful in 26 of 27 cases (96%). Eleven stents were removed percutaneously, two were repositioned and removed with a minor surgical procedure, and 13 were repositioned and deployed in a stable alternate location. The only complication was the development of tricuspid insufficiency in the single case in which the procedure failed (4% complication rate). This patient's stent was eventually surgically removed from the right ventricle. CONCLUSION: Misplaced or migrated endovascular Palmaz and Wallstents can be effectively managed with few complications by using a variety of percutaneous techniques.


Assuntos
Vasos Sanguíneos , Migração de Corpo Estranho/terapia , Radiografia Intervencionista , Stents , Adulto , Idoso , Angiografia , Cateterismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Stents/efeitos adversos
13.
Transplantation ; 68(3): 446-9, 1999 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-10459550

RESUMO

BACKGROUND: The piggyback technique of orthotopic liver transplantation is an attractive alternative that preserves the recipient inferior vena cava and allows uninterrupted venous blood return during the anhepatic phase. As with other transplantation techniques, the vascular anastomoses required by the piggyback technique can develop strictures. METHODS: Review of records of 264 piggyback transplantations revealed two cases of delayed-onset hepatic venous obstruction from anastomotic strictures. Both patients also had symptoms of inferior vena cava obstruction, with azotemia and lower extremity edema. Both patients were treated percutaneously with balloon-expandable stents. RESULTS: Rapid, dramatic resolution of symptoms was achieved in both patients. Patients remain completely asymptomatic at 39 and 3 months of follow-up. CONCLUSIONS: Hepatic venous anastomotic strictures in recipients of piggyback technique transplants are a very uncommon complication. They may be easily and effectively treated by minimally invasive endovascular intervention.


Assuntos
Síndrome de Budd-Chiari/etiologia , Síndrome de Budd-Chiari/terapia , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Adolescente , Cateterismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents
14.
Cardiovasc Intervent Radiol ; 22(4): 298-304, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10415219

RESUMO

PURPOSE: To evaluate the efficacy of covered stents for the treatment of transjugular intrahepatic portosystemic shunt (TIPS) obstruction in human subjects with identified or suspected biliary fistulae. METHODS: Five patients were treated for early failure of TIPS revisions. All had mid-shunt thrombus, and four of these had demonstrable biliary fistulae. Three patients also propagated thrombus into the native portal venous system and required thrombolysis. TIPS were revised in four patients using a custom-made polytetrafluoroethylene (PTFE)-covered Wallstent, and in one patient using a custom-made PTFE-covered Gianturco Z-stent. RESULTS: All identified biliary fistulae were successfully sealed. All five patients maintained patency and function of the TIPS during follow-up ranging from 2 days to 21 months (mean 8.4 months). No patient has required additional revision. Thrombosis of the native portal venous system was treated with partial success by mechanical thrombolysis. CONCLUSION: Early and recurrent failure of TIPS with mid-shunt thrombosis, which may be associated with biliary fistulae, can be successfully treated using covered stents. Stent-graft revision appears to be safe, effective, and potentially durable.


Assuntos
Fístula Biliar/terapia , Politetrafluoretileno , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Stents , Fístula Biliar/diagnóstico por imagem , Fístula Biliar/etiologia , Criança , Materiais Revestidos Biocompatíveis , Varizes Esofágicas e Gástricas/tratamento farmacológico , Varizes Esofágicas e Gástricas/cirurgia , Feminino , Fibrinolíticos/uso terapêutico , Seguimentos , Hemorragia Gastrointestinal/tratamento farmacológico , Hemorragia Gastrointestinal/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Veia Porta/patologia , Radiografia , Recidiva , Estudos Retrospectivos , Segurança , Terapia Trombolítica , Resultado do Tratamento , Ultrassonografia Doppler
16.
Radiology ; 212(1): 169-74, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10405738

RESUMO

PURPOSE: To evaluate the usefulness of thoracic computed tomography (CT) after placement of an endovascular stent-graft for the treatment of descending thoracic aortic aneurysm. MATERIALS AND METHODS: From 1992 to 1996, 85 patients with thoracic aortic aneurysm underwent stent-graft placement. In 63 patients, thoracic CT scans were obtained both before and within 10 days after placement. The CT findings were retrospectively studied, and their clinical effect analyzed. In 20 of 63 patients, long-term follow-up CT findings were also evaluated. RESULTS: After stent-graft placement in the 63 patients, CT demonstrated an increase in pleural effusion in 46 (73%), periaortic changes in 21 (33%), perigraft leak in 13 (21%), atelectasis in six (10%), mural thrombus within the stent-graft in two (3%), and new aortic dissection in one (2%). The mean maximum diameter of the aneurysm was 58.8 mm before and 60.0 mm after stent-graft insertion. Sixty-two (98%) patients were successfully treated until discharge. Interventional procedures were performed to eliminate the leakage into the aneurysm sac in 10 patients with perigraft flow depicted at CT. Other complications were managed conservatively. CONCLUSION: Thoracic CT is useful in the treatment of patients after stent-graft insertion for the management of descending thoracic aortic aneurysm.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular , Stents , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/terapia , Análise de Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
17.
J Vasc Interv Radiol ; 10(5): 529-35, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10357476

RESUMO

PURPOSE: To evaluate the performance of portal venous puncture with use of magnetic resonance (MR) guidance, and to place a transjugular intrahepatic portosystemic shunt (TIPS) in a swine model. MATERIALS AND METHODS: A study of 12 swine was performed to evaluate the ability of interventional MR imaging to guide portal vein puncture and TIPS placement. Six swine had catheters placed in the right hepatic vein under C-arm fluoroscopy. A nitinol guide wire was left in the vein and the animals were then moved into an open configuration MR imaging unit. A TIPS needle set was used to puncture the portal vein using MR fluoroscopy. The animals were transferred to the C-arm, and venography confirmed portal vein puncture. A follow-up study was performed in six additional swine to place a TIPS using only MR imaging guidance. MR tracking was used to advance a catheter from the right atrium into the inferior vena cava. Puncture of the portal vein was performed and a nitinol stent was placed, bridging the hepatic parenchyma. MR venogram confirmed placement. RESULTS: Successful portal vein puncture was achieved in all animals. The number of punctures required decreased from 12 in the first animal to a single puncture in the last eight swine. A stent was successfully placed across the hepatic tract in all six swine. CONCLUSIONS: Real-time MR imaging proved to be a feasible method to guide portal vein puncture and TIPS placement in pigs.


Assuntos
Imageamento por Ressonância Magnética , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Animais , Distinções e Prêmios , Flebotomia/métodos , Veia Porta , Radiologia Intervencionista , Sociedades Médicas , Suínos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...