Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Pacing Clin Electrophysiol ; 40(4): 425-433, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28160298

RESUMO

BACKGROUND: Catheter ablations have been traditionally performed with the use of fluoroscopic guidance, which exposes the patient and staff to the inherent risks of radiation. We have developed techniques to eliminate the use of fluoroscopy during cardiac ablations and have been performing completely fluoroless catheter ablations on our patients for over 5 years. METHODS: We present a retrospective analysis of the safety, efficacy, and feasibility data from 500 consecutive patients who underwent nonfluoroscopic catheter ablation, targeting a total of 639 arrhythmias, including atrioventricular reciprocating tachycardia (AVRT), atrioventricular nodal reentrant tachycardia (AVNRT), atrial tachycardia (AT), atrial fibrillation (AF), premature ventricular contractions (PVCs), and ventricular tachycardia (VT). We perform fluoroless ablations using intracardiac electrograms, electroanatomic mapping, and for most cases intracardiac echocardiography. Our experience includes exclusively endocardial cardiac ablations. RESULTS: The mean follow-up was 20.5 months. Recurrence rate for AVRT was 6.5%, for AVNRT 2.5%, for macro-reentrant AT 6.4%, for focal AT 5.4%, for AF 22.6%, for PVC 6.7%, and for VT 21.4%. Major complications occurred in five patients (1.0%); minor complications occurred in three patients (0.6%). No deaths occurred. Fluoroscopy was used in one instance, for 0.3 minutes, to confirm venous access. CONCLUSIONS: Completely fluoroless catheter ablations may be routinely performed for all endocardial ablations without compromising safety, efficacy, or procedural duration.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/cirurgia , Ablação por Cateter/mortalidade , Ablação por Cateter/estatística & dados numéricos , Cirurgia Assistida por Computador/estatística & dados numéricos , Arritmias Cardíacas/diagnóstico por imagem , Mapeamento Potencial de Superfície Corporal/estatística & dados numéricos , Ecocardiografia/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Illinois/epidemiologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prevalência , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
2.
Int J Cardiovasc Imaging ; 32(9): 1349-1356, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27240602

RESUMO

We sought to determine and prospectively validate, with concomitantly performed transthoracic (TTE) and transesophageal echocardiograms (TEE), a TTE-assessed E/e' threshold that can be useful in predicting left atrial appendage (LAA) thrombus in patients with nonvalvular atrial fibrillation (NVAF). The retrospective derivation cohort was comprised of 297 patients with NVAF with TTE performed within 1 year of TEE. The validation cohort was comprised of 266 prospectively enrolled patients with TTE performed immediately prior to TEE. LAA thrombus was detected by TEE in 6.4 % of patients in both cohorts. Receiver operating characteristic (ROC) analyses demonstrated a good discriminatory capacity of lateral E/e' in predicting LAA thrombus in the derivation cohort (AUC 0.72; CI 0.63-0.82; P = 0.001) which was confirmed in the validation cohort (AUC 0.83; CI 0.75-0.91; P < 0.001). In the derivation cohort, ROC curve point-coordinates identified E/e' thresholds of both 9.0 and 8.0 to be associated with 100 % sensitivity, with specificities of 36 and 30 %, respectively. An E/e' threshold of ≥8 was selected a priori for prospective validation, and was associated with 100 % sensitivity and 41 % specificity for LAA thrombus, with positive and negative predictive values of 10 and 100 %, respectively, and positive and negative likelihood ratios of 1.69 and 0, respectively. We determined and validated an E/e' threshold of 8 as a highly sensitive and useful parameter that can aid in identifying patients at very low risk for LAA thrombus and potentially obviate the need for a TEE prior to electrophysiology procedures and restoration of sinus rhythm.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Hemodinâmica , Valva Mitral/diagnóstico por imagem , Trombose/diagnóstico por imagem , Idoso , Área Sob a Curva , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Trombose/etiologia , Trombose/fisiopatologia
3.
J Interv Card Electrophysiol ; 47(1): 125-131, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27221714

RESUMO

PURPOSE: Cryothermal ablation (CTA) for atrioventricular nodal reentrant tachycardia (AVNRT) is considered safer than radiofrequency ablation (RFA) since it eliminates the risk of inadvertent AV block. However, it has not been widely adopted due to high late recurrence rate (LRR). In an effort to improve LRR, we evaluated a new approach to cryothermal mapping (CTM): "time to tachycardia termination" (TTT). METHODS: This single-center study had 88 consecutive patients who underwent CTA using TTT for AVNRT. The CTA catheter was positioned in sinus rhythm at the posteroseptal tricuspid annulus, and then AVNRT was induced. The CTA target site was identified by prompt tachycardia termination in ≤20 s during CTM. Procedural success was defined as no inducible AVNRT and ≤1 single AV nodal echoes. RESULTS: Acute procedural success was achieved in 87 of 88 patients (98.9 %) and was similar to prior studies for both CTA and RFA. No permanent AV block was observed. LRR was 3.7 % at a mean follow-up of 19.7 months. LRR was equivalent to that commonly reported for RFA and improved when compared to conventional CTA. CONCLUSION: TTT for CTA of AVNRT provides enhanced safety and similar long-term efficacy when compared to RFA. Based upon this experience, TTT provides an enhancement to conventional CTA that appears to result in improved long-term outcomes. In light of these findings, it seems reasonable to undertake additional randomized trials to determine whether RFA or CTA using TTT is the optimal approach for the catheter ablation of AVNRT.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Criocirurgia/métodos , Cirurgia Assistida por Computador/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
4.
J Am Soc Echocardiogr ; 29(6): 545-53, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27021354

RESUMO

BACKGROUND: In patients with nonvalvular atrial fibrillation (NVAF), the impact of left ventricular diastolic function on the risk for left atrial appendage (LAA) thrombus has not been prospectively studied. METHODS: At two academic medical centers, patients with NVAF were prospectively enrolled to undergo investigational transthoracic echocardiography immediately before clinically indicated transesophageal echocardiography. Mitral inflow E velocity and tissue Doppler septal and lateral mitral annulus velocities (e') were measured, and E/e' ratios were calculated. RESULTS: Among 266 subjects (mean age, 65 years; 32% women), 17 (6.4%) had LAA thrombus. Patients with LAA thrombus had a higher mean CHA2DS2-VASc score (4.6 ± 1.7 vs 3.0 ± 1.8, P < .001), a higher mean lateral E/e' ratio (19.4 ± 10.1 vs 10.2 ± 5.6, P < .001), and a lower mean lateral e' velocity (7.0 ± 3.2 vs 10.4 ± 3.7 cm/sec, P = .001). There was a good discriminative capacity for E/e' (area under the curve, 0.83; P < .001) and e' velocity (area under the curve, 0.76; P = .001). None of the patients with normal E/e' ratios or normal e' velocities had LAA thrombus. Both E/e' (odds ratio, 1.13 per point; 95% CI, 1.06-1.20; P < .001) and e' velocity (odds ratio, 0.76 per 1 cm/sec; 95% CI, 0.63-0.92; P = .005) provided independent and incremental predictive value beyond the CHA2DS2-VASc score; however, E/e' provided greater incremental value than e' velocity (P = .036). Analyses using septal and averaged E/e' and septal e' velocity yielded similar results. Diastolic function parameters were also associated with the presence and intensity of left atrial spontaneous echo contrast, a precursor of LAA thrombus. CONCLUSIONS: This prospective and concomitant evaluation of diastolic function and LAA thrombus in patients with NVAF demonstrates that E/e' ratio and e' velocity are associated with LAA thrombus, independent of CHA2DS2-VASc score, and may play a role in identifying patients at low risk for LAA thrombus. These data suggest that diastolic function assessment may improve stroke prediction in patients with NVAF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Volume Sistólico , Trombose/diagnóstico , Trombose/epidemiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia , Idoso , Apêndice Atrial/diagnóstico por imagem , Chicago/epidemiologia , Comorbidade , Ecocardiografia/métodos , Ecocardiografia/estatística & dados numéricos , Feminino , Doenças das Valvas Cardíacas , Humanos , Incidência , Masculino , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade
5.
Cardiovasc Ultrasound ; 14: 4, 2016 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-26772738

RESUMO

BACKGROUND: The impact of B-type natriuretic peptide (BNP) level on the risk of left atrial appendage (LAA) thrombus in patients with nonvalvular atrial fibrillation (NVAF) has not been prospectively studied. METHODS: In two academic medical centers, we obtained BNP levels immediately prior to transesophageal echocardiogram performed to exclude LAA thrombus in patients with NVAF. RESULTS: Among 261 subjects (mean age 65 ± 12 years; 30 % women) with NVAF, 17 (6.5 %) had LAA thrombus and 85 (32.6 %) had at least mild spontaneous echo contrast (SEC). Mean BNP level was significantly higher in patients with LAA thrombus [775 ± 678 vs. 384 ± 537, P = 0.001]. Receiver operator characteristics analysis demonstrated that BNP has a good discriminatory capacity for LAA thrombus (area under the curve, 0.74; 95 % confidence interval [CI], 0.63-0.85; P = 0.001); BNP ≥ 67 pg/mL was 100 % sensitive and 20 % specific for LAA thrombus. Multivariate logistic regression analysis demonstrated that BNP was not independently associated with LAA thrombus (odds-ratio, 1.05 per 100 pg/mL increment; CI, 0.99-1.12; P = 0.127) after adjusting for CHA2DS2-VASc score; while the latter was independently associated with LAA thrombus after adjusting for BNP level (odds-ratio, 1.46 per CHA2DS2-VASc point; CI, 1.09-1.96; P = 0.011). Nonetheless, BNP was associated with SEC in univariate and multivariate analysis, after adjusting for the CHA2DS2-VASc score, (odds-ratio, 1.08; CI, 1.02-1.14; P = 0.005). CONCLUSIONS: BNP is predictive of SEC. However, it does not provide significant incremental value in the prediction of LAA thrombus.


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/epidemiologia , Peptídeo Natriurético Encefálico/sangue , Trombose/sangue , Trombose/epidemiologia , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Biomarcadores/sangue , Chicago/epidemiologia , Comorbidade , Ecocardiografia/estatística & dados numéricos , Feminino , Humanos , Masculino , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Volume Sistólico , Trombose/diagnóstico
6.
J Atr Fibrillation ; 7(1): 1093, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-27957089

RESUMO

BACKGROUND: The conventional method of cryoballoon ablation of atrial fibrillation involves the use of fluoroscopy for visual guidance. The use of fluoroscopy is accompanied by significant radiation risks to the patient and the medical staff. Herein, we report our experience in performing successful nonfluoroscopic pulmonary vein isolation using cryoballoon ablation in 5 consecutive patients with paroxysmal atrial fibrillation. METHODS AND RESULTS: Five consecutive patients with paroxysmal atrial fibrillation underwent cryoballoon ablation for pulmonary vein isolation using a nonfluoroscopic approach. Pre-procedural cardiac computed tomography or cardiac magnetic resonance imaging was not performed in any patient. A total of twenty pulmonary veins were identified and successfully isolated (100%) with the guidance of intracardiac echocardiography and 3-dimensional electroanatomic mapping. No fluoroscopy was used for the procedures. There were no major procedural adverse events. CONCLUSION: In an unselected group of patients undergoing cryoballoon ablation, a nonfluoroscopic approach is feasible and can be performed safely and effectively while eliminating the risks associated with radiation to both the patient and the medical staff.

7.
J Cardiovasc Electrophysiol ; 23(10): 1078-86, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22571735

RESUMO

BACKGROUND: Catheter ablations are traditionally performed using fluoroscopic guidance, exposing both patients and medical staff to the risks of radiation. Nonfluoroscopic catheter ablation has been used successfully to treat limited types of arrhythmias in children, but whether this approach has broad application in adults is uncertain. The purpose of this study was to evaluate the feasibility, safety, and efficacy of fluoroless catheter ablation in adults being treated for a range of arrhythmias. METHODS AND RESULTS: Retrospective analysis was performed in 2 patient groups (both n = 60): (1) the nonfluoroscopy (NF) group consisting of consecutive adult patients, in which catheter positioning was accomplished exclusively with intracardiac electrograms (IE), electroanatomic mapping (EAM), and intracardiac echocardiography (ICE); and (2) the fluoroscopy (F) group, in which catheter positioning was additionally guided by fluoroscopy. The patients in the F group were selected to match the types of arrhythmias in the NF group. All ablation procedures were performed by one operator. The total procedure time did not differ between groups for any specific type of arrhythmia ablated. Acute procedural success was similar in both groups (NF, 59/60 [98%] and F, 60/60 [100%]). The complications were limited to a groin pseudoaneurysm in the NF group, and pericardial effusion and groin hematoma in the F group. CONCLUSION: Catheter ablations were efficiently and effectively performed in adults with a variety of arrhythmias using only IE, EAM, and ICE for catheter guidance. This nonfluoroscopic technique was feasible, posed no additional safety concerns, and should be readily implementable in most electrophysiology laboratories.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Ultrassonografia de Intervenção , Adulto , Fatores Etários , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doses de Radiação , Radiografia Intervencionista , Estudos Retrospectivos , Resultado do Tratamento
8.
Sleep ; 31(9): 1215-20, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18788646

RESUMO

STUDY OBJECTIVES: Epidemiologic studies have shown a high frequency of major cardiac events at night in patients with coronary artery disease. This has been attributed to the sympathetic surges accompanying rapid eye movement (REM) sleep; the role of non-REM sleep, which comprises 80% of total sleep duration, has been largely neglected. Accordingly, we evaluated the effect of non-REM sleep on contractile function in a region of the left ventricular wall supplied by a flow-limiting coronary stenosis. DESIGN: Eight domestic pigs were chronically instrumented to measure regional left ventricular contractile function (wall thickening), coronary blood flow, and systemic hemodynamic variables. Measurements were obtained: (1) during wakefulness, i.e., conscious condition, prior to imposition of coronary stenosis; (2) during wakefulness following imposition of coronary stenosis (30% reduction of baseline coronary blood flow from 40 +/- 4 to 27 +/- 3 mL/min); and (3) during non-REM sleep with coronary stenosis maintained. RESULTS: During wakefulness, coronary stenosis reduced wall thickening (from 23.3 +/- 3.4% to 15.7 +/- 2.0%), whereas mean arterial pressure and heart rate were unchanged. With coronary stenosis maintained, the onset of non-REM sleep caused 20% decreases in mean arterial pressure and coronary blood flow, accompanied by a cessation of regional wall thickening, i.e., akinesis (wall thickening = 0.2 +/- 2.8%), indicating severe myocardial ischemia. CONCLUSIONS: The arterial hypotension, and associated reduction in coronary blood flow, during non-REM sleep precipitated severe myocardial ischemia in a region of the left ventricular wall supplied by flow-limiting coronary stenosis. Such episodes would occur repeatedly during the sleep cycle and could potentially set the stage for a major cardiac event during the sympathetic activation accompanying REM sleep or morning activities.


Assuntos
Hipotensão/fisiopatologia , Isquemia Miocárdica/fisiopatologia , Sono REM/fisiologia , Sono/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Circulação Coronária/fisiologia , Estenose Coronária/fisiopatologia , Feminino , Contração Miocárdica/fisiologia , Fatores de Risco , Suínos , Sistema Nervoso Simpático/fisiopatologia , Função Ventricular Esquerda/fisiologia , Vigília/fisiologia
9.
J Cardiovasc Pharmacol Ther ; 12(1): 36-43, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17495256

RESUMO

Dofetilide is currently recommended as second-tier therapy to maintain sinus rhythm in patients with paroxysmal atrial fibrillation (PAF) and normal left ventricular function, yet limited data support this recommendation. We examined the safety and efficacy of dofetilide in this setting through a retrospective chart review. We evaluated patients who had symptomatic PAF, normal left ventricular function, and no significant valvular disease. The end points were complete suppression of symptomatic PAF and subjective symptomatic improvement with dofetilide treatment. Over a 3-year period, 34 patients who had failed previous antiarrhythmic therapy were included. Of these, 3 discontinued dofetilide treatment before discharge. Of the remaining 31 who continued treatment after discharge, it was eventually discontinued in 13. At 12 months, symptomatic improvement was observed in 18 of 31 patients, 6 of whom remained asymptomatic. Treatment with dofetilide in this study was successful in less than 1 in 5 patients. Despite careful precautions, serious proarrhythmias, the major limiting side effect of dofetilide, still occurred during long-term follow-up.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Fenetilaminas/uso terapêutico , Sulfonamidas/uso terapêutico , Função Ventricular Esquerda/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Amiodarona/uso terapêutico , Antiarrítmicos/efeitos adversos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Flutter Atrial/induzido quimicamente , Relação Dose-Resposta a Droga , Monitoramento de Medicamentos/métodos , Feminino , Flecainida/uso terapêutico , Seguimentos , Humanos , Pacientes Internados , Síndrome do QT Longo/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Fenetilaminas/efeitos adversos , Propafenona/uso terapêutico , Recidiva , Sotalol/uso terapêutico , Sulfonamidas/efeitos adversos , Taquicardia Ventricular/induzido quimicamente , Resultado do Tratamento , Suspensão de Tratamento/estatística & dados numéricos
10.
Resuscitation ; 62(1): 35-42, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15246581

RESUMO

BACKGROUND: In-hospital cardiopulmonary resuscitation (CPR) has seen a steady increase in the application of technology and techniques since the introduction of closed cardiac massage in 1960. Despite this progress, there has not been a demonstrated improvement in survival rates after in-hospital cardiac arrest over the last 40 years. Identification of prognostic factors associated with survival after a resuscitation attempt can help physician decisions and patients' end-of-life choices in a pre-arrest situation. METHODS: Using an Utstein-based template we analyzed 219 consecutive adult attempted resuscitations in a large urban teaching hospital over a 3-year period. The main outcome measures were survival to discharge, 1 and 3 months. Backwards stepwise logistic regression was used to select baseline variables that predict survival at discharge, 1 and 3 months. RESULTS: Survival rates at discharge, 1 and 3 months were 15.1, 13.3, and 11.5%. Meaningful neurological status (cerebral performance score of 1) at discharge was achieved in 61% of survivors. Independent predictors of survival were: higher body-mass index (BMI), presence of chronic renal insufficiency (CRI), respiratory arrest, ventricular tachycardia/fibrillation (VT/VF) as initial rhythm and arrest early during the hospital stay. A risk model based on these variables demonstrated a significant fit between predicted and observed survival at discharge with goodness of fit test P-value of 0.87. CONCLUSIONS: Survival after in-hospital cardiopulmonary arrest is poor and can be estimated by using clinical variables. If validated in a large prospective trial, this score could help physicians in attempting resuscitation, patients and families in making end-of-life decisions and hospitals in resource allocation.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca/mortalidade , Mortalidade Hospitalar , Idoso , Feminino , Parada Cardíaca/terapia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Estudos Retrospectivos , Risco , Análise de Sobrevida
11.
Arch Intern Med ; 162(12): 1416-9, 2002 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-12076242

RESUMO

A patient who presented with a new apparent seizure was found to have abnormal electrocardiographic findings, with classic features of the Brugada syndrome. He had spontaneous episodes of nonsustained ventricular tachycardia, easily inducible ventricular fibrillation at electrophysiological study in the absence of structural heart disease, and a negative neurological evaluation. These findings suggested that sustained ventricular arrhythmias known to be associated with the Brugada syndrome and resultant cerebral hypoperfusion, rather than a primary seizure disorder, were responsible for the event. Patients with the Brugada syndrome often present with sudden death or with syncope resulting from ventricular arrhythmias. In consideration of its variability in presentation sometimes mimicking other disorders, primary care physicians and internists should be aware of its often transient electrocardiographic features.


Assuntos
Bloqueio de Ramo/complicações , Bloqueio de Ramo/diagnóstico , Síncope/etiologia , Adulto , Bloqueio de Ramo/fisiopatologia , Diagnóstico Diferencial , Eletrocardiografia , Humanos , Masculino , Síndrome , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Fatores de Tempo , Fibrilação Ventricular/complicações , Fibrilação Ventricular/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...