Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesth Analg ; 100(6): 1797-1803, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15920216

RESUMO

In this study, we compared the effect of isoflurane and desflurane on the posterior tibial somatosensory evoked potential recorded by scalp electrodes during correction of idiopathic scoliosis in pediatric patients. Depth of sedation was controlled by maintaining bispectral index (BIS) at 60 throughout the study. Comparison of patients breathing desflurane and isoflurane showed an evoked cortical amplitude (N37-P45) of 0.53 +/- 0.3 microV versus 1.3 +/- 0.8 microV (P = 0.014), respectively. In addition to this comparison, a crossover design was included whereby the desflurane or isoflurane received in the first part of the study was changed to the other anesthetic. Substituting one anesthetic for another confirmed our initial finding that the cortical evoked amplitude is greater with isoflurane than with desflurane. No differential effect was found between desflurane and isoflurane on the evoked subcortical (N31-P34) amplitude or the P37 latency.


Assuntos
Anestesia por Inalação , Anestésicos Inalatórios , Eletroencefalografia/efeitos dos fármacos , Potenciais Somatossensoriais Evocados/efeitos dos fármacos , Isoflurano , Isoflurano/análogos & derivados , Procedimentos Ortopédicos , Escoliose/cirurgia , Adolescente , Anestésicos Inalatórios/administração & dosagem , Temperatura Corporal/efeitos dos fármacos , Criança , Pré-Escolar , Estudos Cross-Over , Desflurano , Estimulação Elétrica , Feminino , Hemodinâmica , Humanos , Isoflurano/administração & dosagem , Masculino , Monitorização Intraoperatória , Estudos Prospectivos , Nervo Tibial/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...