Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neurosurg ; 123(2): 453-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25978711

RESUMO

OBJECT: Stent-assisted embolization (SAE) has broadened the scope of endovascular cerebral aneurysm treatment. The risks associated with stent selection and configuration are poorly defined. In this study, the authors aimed to characterize the risk factors that contribute to complications in SAE of intracranial aneurysms. METHODS: Over a 10-year period, a single surgeon treated 486 aneurysms with SAE in which open-cell Neuroform or closed-cell Enterprise stents were used. Single stents were used in 386 cases, overlapping stents were deployed in 80 cases, and Y-configuration stents were used in the remaining 20 cases. All neurological complications, which included transient deficits, were analyzed; disabling strokes and death were considered major complications. The chi-square test and multivariate logistic regression were used to evaluate the influence of aneurysm size and morphology, aneurysm location, stent selection, and stent configuration on complication rates. RESULTS: There were 7 deaths (1.4%), 9 major strokes (1.9%), and 18 minor neurological complications (3.7%). For all complications, multivariate analysis revealed that large aneurysm size (10-25 mm; p = 0.01), giant aneurysm size (> 25 mm; p = 0.04), fusiform aneurysm morphology (p = 0.03), and using a Y-configuration stent (p = 0.048) were independent risk factors. For the major complications, independent risk factors included an aneurysm in the posterior circulation (p = 0.02), using an overlapping stent configuration (p = 0.03), and using a Y-configuration stent (p < 0.01). CONCLUSIONS: In this series, SAE for cerebral aneurysm treatment carried an acceptable complication rate. With continued innovations in techniques and devices and with increased experience, the complication rates associated with SAE may be even lower in the future.


Assuntos
Prótese Vascular/efeitos adversos , Embolização Terapêutica/efeitos adversos , Aneurisma Intracraniano/cirurgia , Stents/efeitos adversos , Acidente Vascular Cerebral/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas , Embolização Terapêutica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
2.
Neurosurgery ; 74(3): 286-91, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24335816

RESUMO

BACKGROUND: Aneurysmal subarachnoid hemorrhage is a disabling disease. Endovascular coiling provides minimally invasive, effective, and safe treatment of both ruptured and unruptured intracranial aneurysms. Intracranial stents have improved the endovascular treatment of complex aneurysms, but the long-term durability of this treatment modality needs clarification. OBJECTIVE: To elucidate the long-term success of intracranial stent use in the treatment of aneurysms. METHODS: Four hundred ten patients were treated with stent-assisted endovascular management of 464 aneurysms. Treatment of 363 small aneurysms, 88 large aneurysms, and 13 giant aneurysms was analyzed with respect to both long-term anatomic results with digital subtraction angiography and magnetic resonance angiography over the follow-up period. RESULTS: The 6-month angiographic results of 387 aneurysm treatments revealed complete aneurysm occlusion in 282 (72.9%), residual aneurysm neck in 50 (12.9%), and residual aneurysm filling in 55 (14.2%). Long-term radiographic follow-up, performed in 262 patients (mean, 3.63 years), showed significant recurrence of only 3 aneurysms after 6-month follow-up imaging. Forty-eight aneurysms (11.9%) were considered radiographic failures during the follow-up period. CONCLUSION: The aneurysm recurrence rate after stent-assisted embolization in this series was similar to published data using only coil embolization for the period between treatment and the initial follow-up imaging. For aneurysms that do not initially recur, the presented data suggest improved durability in the subsequent long-term follow-up period. ABBREVIATIONS: DSA, digital subtraction angiographyMRA, magnetic resonance angiography.


Assuntos
Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomógrafos Computadorizados , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...