Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Radiographics ; 44(2): e230129, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38300813

RESUMO

The breasts undergo marked physiologic changes during lactation that can make conventional imaging evaluation with mammography and US challenging. MRI can be a valuable diagnostic aid to differentiate physiologic and benign processes from malignancy in patients who are lactating. In addition, MRI may allow more accurate delineation of disease involvement than does conventional imaging and assists in locoregional staging, screening of the contralateral breast, assessment of response to neoadjuvant chemotherapy, and surgical planning. Although the American College of Radiology recommends against patients undergoing contrast-enhanced MRI during pregnancy because of fetal safety concerns, contrast-enhanced MRI is safe during lactation. As more women delay childbearing, the incidence of pregnancy-associated breast cancer (PABC) and breast cancer in lactating women beyond the 1st year after pregnancy is increasing. Thus, MRI is increasingly being performed in lactating women for diagnostic evaluation and screening of patients at high risk. PABC is associated with a worse prognosis than that of non-PABCs, with delays in diagnosis contributing to an increased likelihood of advanced-stage disease at diagnosis. Familiarity with the MRI features of the lactating breast and the appearance of various pathologic conditions is essential to avoid diagnostic pitfalls and prevent delays in cancer diagnosis and treatment. The authors review clinical indications for breast MRI during lactation, describe characteristic features of the lactating breast at MRI, and compare MRI features of a spectrum of benign and malignant breast abnormalities. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material. See the invited commentary by Chikarmane in this issue.


Assuntos
Azidas , Neoplasias da Mama , Lactação , Propanolaminas , Gravidez , Feminino , Humanos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Imageamento por Ressonância Magnética/métodos
2.
3D Print Med ; 9(1): 8, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36952139

RESUMO

The use of medical 3D printing has expanded dramatically for breast diseases. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (SIG) provides updated appropriateness criteria for breast 3D printing in various clinical scenarios. Evidence-based appropriateness criteria are provided for the following clinical scenarios: benign breast lesions and high-risk breast lesions, breast cancer, breast reconstruction, and breast radiation (treatment planning and radiation delivery).

4.
Radiology ; 306(3): e213199, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36378030

RESUMO

Background There is increasing interest in noncontrast breast MRI alternatives for tumor visualization to increase the accessibility of breast MRI. Purpose To evaluate the feasibility and accuracy of generating simulated contrast-enhanced T1-weighted breast MRI scans from precontrast MRI sequences in biopsy-proven invasive breast cancer with use of deep learning. Materials and Methods Women with invasive breast cancer and a contrast-enhanced breast MRI examination that was performed for initial evaluation of the extent of disease between January 2015 and December 2019 at a single academic institution were retrospectively identified. A three-dimensional, fully convolutional deep neural network simulated contrast-enhanced T1-weighted breast MRI scans from five precontrast sequences (T1-weighted non-fat-suppressed [FS], T1-weighted FS, T2-weighted FS, apparent diffusion coefficient, and diffusion-weighted imaging). For qualitative assessment, four breast radiologists (with 3-15 years of experience) blinded to whether the method of contrast was real or simulated assessed image quality (excellent, acceptable, good, poor, or unacceptable), presence of tumor enhancement, and maximum index mass size by using 22 pairs of real and simulated contrast-enhanced MRI scans. Quantitative comparison was performed using whole-breast similarity and error metrics and Dice coefficient analysis of enhancing tumor overlap. Results Ninety-six MRI examinations in 96 women (mean age, 52 years ± 12 [SD]) were evaluated. The readers assessed all simulated MRI scans as having the appearance of a real MRI scan with tumor enhancement. Index mass sizes on real and simulated MRI scans demonstrated good to excellent agreement (intraclass correlation coefficient, 0.73-0.86; P < .001) without significant differences (mean differences, -0.8 to 0.8 mm; P = .36-.80). Almost all simulated MRI scans (84 of 88 [95%]) were considered of diagnostic quality (ratings of excellent, acceptable, or good). Quantitative analysis demonstrated strong similarity (structural similarity index, 0.88 ± 0.05), low voxel-wise error (symmetric mean absolute percent error, 3.26%), and Dice coefficient of enhancing tumor overlap of 0.75 ± 0.25. Conclusion It is feasible to generate simulated contrast-enhanced breast MRI scans with use of deep learning. Simulated and real contrast-enhanced MRI scans demonstrated comparable tumor sizes, areas of tumor enhancement, and image quality without significant qualitative or quantitative differences. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Slanetz in this issue. An earlier incorrect version appeared online. This article was corrected on January 17, 2023.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Estudos Retrospectivos , Mama/diagnóstico por imagem , Mama/patologia , Imageamento por Ressonância Magnética/métodos , Meios de Contraste
7.
Clin Imaging ; 80: 359-363, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34507268

RESUMO

OBJECTIVE: There are currently various conflicting recommendations for breast cancer screening with mammography in women between ages 40-49. There are no specific guidelines for breast cancer screening in women of this age group prior to assisted reproductive technology (ART) for the treatment of infertility. The purpose of our study was to evaluate outcomes of screening mammography, specifically ordered for the purpose of pre-fertility treatment clearance in women aged 40-49 years old. MATERIALS AND METHODS: This was an IRB approved retrospective study of women aged 40-49 presenting for screening mammography prior to ART between January 2010 and October 2018. Clinical history, imaging, and pathology results were gathered from the electronic medical record. Descriptive statistics were performed. RESULTS: Our study cohort consisted of 118 women with a mean age of 42 years (range 40-49). Sixteen of 118 (14%) women were recalled from screening for additional diagnostic work-up. Five of the 16 (31%) were recommended for biopsy (BI-RADS 4 or 5). One of 5 biopsies yielded a malignant result (PPV 20%). Overall cancer detection rate was 0.85% or 8.5 women per 1000 women screened. The single cancer in this cohort was an ER+ PR+ HER2- invasive ductal carcinoma. CONCLUSION: Screening mammography in women 40-49 performed prior to initiation of ART may identify asymptomatic breast malignancy. In accordance with ACR and SBI guidelines to screen women of this age group, women of this age group should undergo screening mammography prior to ART.


Assuntos
Neoplasias da Mama , Mamografia , Adulto , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Detecção Precoce de Câncer , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
NPJ Breast Cancer ; 7(1): 25, 2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33674614

RESUMO

Neoadjuvant therapy in breast cancer can downstage axillary lymph nodes and reduce extent of axillary surgery. As such, accurate determination of nodal status after neoadjuvant therapy and before surgery impacts surgical management. There are scarce data on the diagnostic accuracy of breast magnetic resonance imaging (MRI) for nodal evaluation after neoadjuvant therapy in patients with invasive lobular carcinoma (ILC), a diffusely growing tumor type. We retrospectively analyzed patients with stage 1-3 ILC who underwent pre-operative breast MRI after either neoadjuvant chemotherapy or endocrine therapy at our institution between 2006 and 2019. Two breast radiologists reviewed MRIs and evaluated axillary nodes for suspicious features. All patients underwent either sentinel node biopsy or axillary dissection. We evaluated sensitivity, specificity, negative and positive predictive values, and overall accuracy of the post-treatment breast MRI in predicting pathologic nodal status. Of 79 patients, 58.2% received neoadjuvant chemotherapy and 41.8% neoadjuvant endocrine therapy. The sensitivity and negative predictive value of MRI were significantly higher in the neoadjuvant endocrine therapy cohort than in the neoadjuvant chemotherapy cohort (66.7 vs. 37.9%, p = 0.012 and 70.6 vs. 40%, p = 0.007, respectively), while overall accuracy was similar. Upstaging from clinically node negative to pathologically node positive occurred in 28.0 and 41.7%, respectively. In clinically node positive patients, those with an abnormal post-treatment MRI had a significantly higher proportion of patients with ≥4 positive nodes on pathology compared to those with a normal MRI (61.1 versus 16.7%, p = 0.034). Overall, accuracy of breast MRI for predicting nodal status after neoadjuvant therapy in ILC was low in both chemotherapy and endocrine therapy cohorts. However, post-treatment breast MRI may help identify patients with a high burden of nodal disease (≥4 positive nodes), which could impact pre-operative systemic therapy decisions. Further studies are needed to assess other imaging modalities to evaluate for nodal disease following neoadjuvant therapy and to improve clinical staging in patients with ILC.

10.
3D Print Med ; 7(1): 6, 2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33559793

RESUMO

Three-dimensional (3D) printing is a method by which two-dimensional (2D) virtual data is converted to 3D objects by depositing various raw materials into successive layers. Even though the technology was invented almost 40 years ago, a rapid expansion in medical applications of 3D printing has only been observed in the last few years. 3D printing has been applied in almost every subspecialty of medicine for pre-surgical planning, production of patient-specific surgical devices, simulation, and training. While there are multiple review articles describing utilization of 3D printing in various disciplines, there is paucity of literature addressing applications of 3D printing in breast cancer management. Herein, we review the current applications of 3D printing in breast cancer management and discuss the potential impact on future practices.

11.
Clin Imaging ; 75: 16-21, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33486147

RESUMO

OBJECTIVE: The objective of our study was to determine whether, in the digital era, imaging features of a primary breast tumor can be used to influence the decision to biopsy ipsilateral breast calcifications that occur following surgery in women treated with breast conservation surgery (BCS). MATERIALS AND METHODS: We retrospectively identified women treated with BCS who subsequently developed suspicious calcifications in the treated breast (BI-RADS 4 or 5) from January 2012 - December 2018. Only cases with histopathological diagnosis by stereotactic or surgical biopsy were included. Pathology reports were reviewed, and biopsy results were considered malignant if invasive carcinoma or ductal carcinoma in situ (DCIS) was found. All other results were considered benign. Fisher's exact test was done comparing frequencies of malignancy between those patients whose original tumor had calcifications versus those whose original tumors were not calcified. RESULTS: Of 90 women with suspicious calcifications on a post-BCS mammogram, 65 (72.2%) were biopsy proven benign and 25 (27.8%) were malignant. The original tumor presented without calcifications in 39 patients (43%), and 51 (57%) had calcifications with or without associated mass, focal asymmetry, or architectural distortion. New calcifications were less likely to be malignant if the original tumor presented without calcifications (5/39; 12.8%) as compared to original tumors with calcifications (20/51; 38.5%) [p-value < 0.05]. CONCLUSION: New calcifications after BCS are significantly less likely to be malignant if the original tumor presented without calcifications. However, with a PPV of 12.8%, even calcifications in a patient with a non-calcified primary tumor require biopsy.


Assuntos
Doenças Mamárias , Neoplasias da Mama , Biópsia , Mama/diagnóstico por imagem , Mama/cirurgia , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mamografia , Mastectomia Segmentar , Estudos Retrospectivos
12.
J Digit Imaging ; 33(4): 1041-1046, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32468486

RESUMO

Although machine learning (ML) has made significant improvements in radiology, few algorithms have been integrated into clinical radiology workflow. Complex radiology IT environments and Picture Archiving and Communication System (PACS) pose unique challenges in creating a practical ML schema. However, clinical integration and testing are critical to ensuring the safety and accuracy of ML algorithms. This study aims to propose, develop, and demonstrate a simple, efficient, and understandable hardware and software system for integrating ML models into the standard radiology workflow and PACS that can serve as a framework for testing ML algorithms. A Digital Imaging and Communications in Medicine/Graphics Processing Unit (DICOM/GPU) server and software pipeline was established at a metropolitan county hospital intranet to demonstrate clinical integration of ML algorithms in radiology. A clinical ML integration schema, agnostic to the hospital IT system and specific ML models/frameworks, was implemented and tested with a breast density classification algorithm and prospectively evaluated for time delays using 100 digital 2D mammograms. An open-source clinical ML integration schema was successfully implemented and demonstrated. This schema allows for simple uploading of custom ML models. With the proposed setup, the ML pipeline took an average of 26.52 s per second to process a batch of 100 studies. The most significant processing time delays were noted in model load and study stability times. The code is made available at " http://bit.ly/2Z121hX ". We demonstrated the feasibility to deploy and utilize ML models in radiology without disrupting existing radiology workflow.


Assuntos
Sistemas de Informação em Radiologia , Radiologia , Software , Inteligência Artificial , Humanos , Integração de Sistemas , Fluxo de Trabalho
13.
AJR Am J Roentgenol ; 214(4): 938-944, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32023120

RESUMO

OBJECTIVE. The purpose of this study was to assess the performance of diagnostic mammography alone for evaluation of palpable symptoms in women with almost entirely fatty breast composition. MATERIALS AND METHODS. All diagnostic mammograms performed for palpable symptoms in women who had been assigned a breast density of "almost entirely fatty" over an 8-year period (2009-2017) at an academic breast center were retrospectively identified. Each symptomatic breast was considered a separate case and analyses were performed at the case level. Clinical, imaging, and pathologic results were reviewed. Descriptive statistics and 2 × 2 contingency table analyses were performed. RESULTS. The study cohort included 323 cases evaluated with mammography. Of these, 294 (91%) had undergone targeted ultrasound. At mammography, 240 (74%) had no correlate to the palpable lump; 38 (12%), a benign correlate; and 45 (14%), a suspicious correlate. Three cases had incidental suspicious mammographic findings, for a total of 48 positive mammography cases. Twenty-seven (8%) cases were malignant. Mammography alone detected all but one cancer, which was detected by ultrasound. In retrospect, the woman from whom this single false-negative mammogram was obtained did not have almost entirely fatty breast density. Mammography alone yielded a negative predictive value of 99.6%, percentage of diagnostic examinations recommended for biopsy that resulted in a tissue diagnosis of malignancy within 1 year of 54%, sensitivity of 96%, and specificity of 93%. Adjunct ultrasound contributed to 11 false-positives but also identified benign correlates in eight cases with no mammographic finding. CONCLUSION. In patients with almost entirely fatty breast tissue presenting with palpable symptoms, mammography alone had a high sensitivity and specificity. Our results support that mammography alone may be sufficient for evaluation of palpable symptoms in these women as long as density criteria are strictly applied.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Mamografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Palpação , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária
14.
J Magn Reson Imaging ; 52(3): 697-709, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31746088

RESUMO

Historically, breast magnetic resonance imaging (MRI) was not considered an effective modality in the evaluation of ductal carcinoma in situ (DCIS). Over the past decade this has changed, with studies demonstrating that MRI is the most sensitive imaging tool for detection of all grades of DCIS. It has been suggested that not only is breast MRI the most sensitive imaging tool for detection but it may also detect the most clinically relevant DCIS lesions. The role and outcomes of MRI in the preoperative setting for patients with DCIS remains controversial; however, several studies have shown benefit in the preoperative evaluation of extent of disease as well as predicting an underlying invasive component. The most common presentation of DCIS on MRI is nonmass enhancement (NME) in a linear or segmental distribution pattern. Maximizing breast MRI spatial resolution is therefore beneficial, given the frequent presentation of DCIS as NME on MRI. Emerging MRI techniques, such as diffusion-weighted imaging (DWI), have shown promising potential to discriminate DCIS from benign and invasive lesions. Future opportunities including advanced imaging visual techniques, radiomics/radiogenomics, and machine learning / artificial intelligence may also be applicable to the detection and treatment of DCIS. Level of Evidence: 3 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2020;52:697-709.


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Carcinoma Intraductal não Infiltrante , Inteligência Artificial , Mama , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética
15.
Clin Imaging ; 59(2): 144-147, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31816541

RESUMO

Delayed onset breast implant-associated reactions range widely in symptomatology and underlying etiology. With increasing reports of breast implant-associated anaplastic large cell lymphoma (BIA-ALCL), findings such as unilateral breast swelling, capsular thickening, and peri-implant fluid raise concern. Synovial metaplasia is a benign histologic finding commonly associated with implant capsules and can be an unusual cause of such symptoms. Though the clinical significance of synovial metaplasia is unknown, it is important to consider this entity in the differential diagnosis for delayed onset breast symptoms, with signs otherwise concerning for BIA-ALCL or infection.


Assuntos
Implantes de Mama , Neoplasias da Mama , Mama/diagnóstico por imagem , Mama/patologia , Linfoma Anaplásico de Células Grandes , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/patologia , Diagnóstico Diferencial , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia , Metaplasia , Pessoa de Meia-Idade , Ultrassonografia Mamária
16.
J Breast Imaging ; 2(6): 615-628, 2020 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38424865

RESUMO

Image optimization at digital breast tomosynthesis (DBT) involves a series of trade-offs between multiple variables. Wider sweep angles provide better separation of overlapping tissues, but they result in decreased in-plane resolution as well as increased scan times that may be prone to patient motion. Techniques to reduce scan time, such as continuous tube motion and pixel binning during detector readout, reduce the chances of patient motion but may degrade the in-plane resolution. Image artifacts are inherent to DBT because of the limited angular range of the acquisition. Iterative reconstruction algorithms have been shown to reduce various DBT artifacts.

17.
J AAPOS ; 23(3): 165-167.e1, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30771536

RESUMO

Children with craniofacial malformations frequently require spectacles but have difficulty finding an acceptable fit with current offerings of pediatric spectacle frames. We describe a novel method for creating custom 3D-printed spectacle frames based on a 3D reconstruction of a prior computed tomography scan. This method offers the ability to create better-fitting spectacles to children who are not served by "off the rack" frames.


Assuntos
Anormalidades Craniofaciais/complicações , Anormalidades Craniofaciais/terapia , Óculos , Imageamento Tridimensional/métodos , Impressão Tridimensional , Erros de Refração/terapia , Tomografia Computadorizada por Raios X/métodos , Pré-Escolar , Desenho de Equipamento , Feminino , Humanos , Refração Ocular/fisiologia , Erros de Refração/etiologia , Erros de Refração/fisiopatologia
18.
J Cardiovasc Comput Tomogr ; 13(1): 21-30, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30322772

RESUMO

BACKGROUND: Successful transcatheter aortic valve replacement (TAVR) requires an understanding of how a prosthetic valve will interact with a patient's anatomy in advance of surgical deployment. To improve this understanding, we developed a benchtop workflow that allows for testing of physical interactions between prosthetic valves and patient-specific aortic root anatomy, including calcified leaflets, prior to actual prosthetic valve placement. METHODS: This was a retrospective study of 30 patients who underwent TAVR at a single high volume center. By design, the dataset contained 15 patients with a successful annular seal (defined by an absence of paravalvular leaks) and 15 patients with a sub-optimal seal (presence of paravalvular leaks) on post-procedure transthoracic echocardiogram (TTE). Patients received either a balloon-expandable (Edwards Sapien or Sapien XT, n = 15), or a self-expanding (Medtronic CoreValve or Core Evolut, n = 14, St. Jude Portico, n = 1) valve. Pre-procedural computed tomography (CT) angiograms, parametric geometry modeling, and multi-material 3D printing were utilized to create flexible aortic root physical models, including displaceable calcified valve leaflets. A 3D printed adjustable sizing device was then positioned in the aortic root models and sequentially opened to larger valve sizes, progressively flattening the calcified leaflets against the aortic wall. Optimal valve size and fit were determined by visual inspection and quantitative pressure mapping of interactions between the sizer and models. RESULTS: Benchtop-predicted "best fit" valve size showed a statistically significant correlation with gold standard CT measurements of the average annulus diameter (n = 30, p < 0.0001 Wilcoxon matched-pairs signed rank test). Adequateness of seal (presence or absence of paravalvular leak) was correctly predicted in 11/15 (73.3%) patients who received a balloon-expandable valve, and in 9/15 (60%) patients who received a self-expanding valve. Pressure testing provided a physical map of areas with an inadequate seal; these corresponded to areas of paravalvular leak documented by post-procedural transthoracic echocardiography. CONCLUSION: We present and demonstrate the potential of a workflow for determining optimal prosthetic valve size that accounts for aortic annular dimensions as well as the active displacement of calcified valve leaflets during prosthetic valve deployment. The workflow's open source framework offers a platform for providing predictive insights into the design and testing of future prosthetic valves.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Aortografia/métodos , Calcinose/diagnóstico , Calcinose/fisiopatologia , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Modelos Anatômicos , Modelos Cardiovasculares , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Fluxo de Trabalho
19.
J Minim Invasive Gynecol ; 24(7): 1239-1242, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28634015

RESUMO

The combination of a thorough physical examination and imaging with either magnetic resonance imaging (MRI) or pelvic ultrasound are important in the preoperative planning for deep infiltrating endometriosis (DIE). A 2-dimensional (2D) rendering of the pathology by imaging does not always accurately represent intraoperative findings. The detailed topographical relationship and extent of surrounding tissue invasion can be better appreciated by 3-dimensional (3D) modeling. A 49-year-old patient with history of endometriosis and persistent pain underwent preoperative MRI that showed features consistent with DIE endometriosis. Surgery was performed, and the findings were documented. A 3D printed model of the DIE was generated from the MRI and retrospectively compared with intraoperative findings. The 3D model demonstrated both the laterality and spatial relationship of the endometriotic nodule to the posterior uterine wall and rectum. Three-dimensional printing of DIE may be a beneficial adjunct to 2D imaging and can identify further structural relationships to support surgical planning.


Assuntos
Endometriose/diagnóstico por imagem , Enteropatias/diagnóstico por imagem , Modelos Anatômicos , Impressão Tridimensional , Doenças Uterinas/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade
20.
Ann Vasc Surg ; 43: 311.e15-311.e23, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28502889

RESUMO

Type II Abernethy malformations, characterized by side-to-side portosystemic shunting with preserved intrahepatic portal venous system, have been treated with shunt closure surgically and endovascularly. Three-dimensional printing has been used to develop highly accurate patient-specific representations for surgical and endovascular planning and intervention. This innovation describes 3-dimensional printing to successfully close a flush-oriented type II Abernethy malformation with discrepant dimensions on computed tomography, conventional venography, and intravascular ultrasound, using a 12-mm Amplatzer atrial septal occluder device.


Assuntos
Procedimentos Endovasculares/instrumentação , Modelos Anatômicos , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Veia Porta/anormalidades , Impressão Tridimensional , Dispositivo para Oclusão Septal , Malformações Vasculares/terapia , Angiografia Digital , Criança , Angiografia por Tomografia Computadorizada , Humanos , Circulação Hepática , Masculino , Flebografia/métodos , Veia Porta/diagnóstico por imagem , Veia Porta/fisiopatologia , Desenho de Prótese , Resultado do Tratamento , Ultrassonografia de Intervenção , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...