1.
J Chromatogr A ; 1678: 463347, 2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-35908511

RESUMO

The long-lived positron emitter 89Zr is a highly promising nuclide employed in diagnostic Positron Emission Tomography (PET) imaging. Methods of radiochemical processing to obtain 89Zr for clinical use are traditionally performed with a single hydroxamate resin column. Herein, we present a tandem column purification method for the preparation of high-purity 89Zr from cyclotron bombarded natural Y metal foils. The primary column is a macroporous, strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary microcolumn, with an internal volume of 33 µL, is packed with an extraction chromatography resin (ExCR) loaded with di-(2-ethylhexyl)phosphoric acid (HDEHP). A condition of "inverted selectivity" is presented, wherein the 89Zr elution from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89Zr from one column to the next allows two sequential purification steps to be performed prior to the final elution of the 89Zr product. This approach assures delivery of high purity 89Zr. The tandem column purification process has been implemented into a prototype automated fluidic system. Optimization of the method is presented, followed by evaluation of the process using seven cyclotron bombarded Y metal foil targets. Once optimized, we found that 93.7 ± 2.3% of the 89Zr present in the foils was recovered in the secondary column elution fraction (0.8 M oxalic acid). Radiochromatograms of the product elution peaks enabled determination of full width at half-maximum (FWHM) and 89Zr collection yields as a function of volume. Because of the small size of the secondary microcolumn, a 89Zr product volume of ∼0.28 mL is reported, which provides a substantially increased nuclide concentration over traditional methods. Finally, we evaluated the transchelation of the resulting 89Zr oxalate product to deferoxamine mesylate (DFOM) salt. We observed effective specific activities (ESA) and bindable metals concentrations ([MB]) that exceed those reported by the traditional single hydroxamate column method.


Assuntos
Ciclotrons , Radioisótopos , Ânions , Cromatografia , Ácidos Hidroxâmicos/química , Tomografia por Emissão de Pósitrons , Zircônio/química
2.
J Chromatogr A ; 1567: 37-46, 2018 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-30054129

RESUMO

The development of a tandem column purification method for the preparation of high-purity 89Zr(IV) oxalate is presented. The primary column was a macroporous strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary column, with an internal volume of 33 µL, was packed with hydroxamate resin. A condition of inverted selectivity was developed, whereby the 89Zr eluent solution for the primary column is equivalent to the 89Zr load solution for the secondary column. The ability to transfer 89Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89Zr(IV) oxalate. This approach assures delivery of high purity 89Zr product and assures a 89Zr product that is eluted in a substantially smaller volume than is possible when using the traditionally-employed single hydroxamate resin column method. The tandem column purification process has been implemented into a prototype automated fluidic system. The system is configured with on-line gamma detection so column effluents can be monitored in near-real time. The automated method was tested using seven cyclotron bombarded Y foil targets. It was found that 95.1 ±â€¯1.3% of the 89Zr present in the foils was recovered in the secondary column elution fraction. Furthermore, elution peak analysis of several 89Zr elution profile radiochromatograms made possible the determination of 89Zr recovery as a function of volume; a 89Zr product volume that contains 90% of the mean secondary column elution peak can be obtained in 0.29 ±â€¯0.06 mL (representing 86 ±â€¯5% of the 89Zr activity in the target). This product volume represents a significant improvement in radionuclide product concentration over the predominant method used in the field. In addition to the reduced 89Zr product elution volume, titrations of the 89Zr product with deferoxamine mesylate salt across two preparatory methods resulted in mean effective specific activity (ESA) values of 279 and 340 T Bq·mmole-1 and mean bindable metals concentrations ([MB]) of 13.5 and 16.7 nmole·g-1. These ESA and [MB] values infer that the 89Zr(IV) oxalate product resulting from this tandem column isolation method has the highest purity reported to date.


Assuntos
Resinas de Troca Aniônica/química , Técnicas de Química Analítica/métodos , Radioisótopos/isolamento & purificação , Zircônio/isolamento & purificação , Ciclotrons , Ácidos Hidroxâmicos/química , Ítrio/química
3.
Appl Radiat Isot ; 132: 85-94, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29172059

RESUMO

Zirconium-89 (89Zr) is a long-lived (t1/2 = 78.4h) positron-emitting isotope that is useful for positron emission tomography (PET) based diagnostic imaging using radiolabeled antibodies. Hydroxamate resin columns are predominantly used for the purification of 89Zr from cyclotron bombarded natY targets dissolved in strong HCl. 89Zr is conventionally eluted from the resin in 1M oxalic acid (H2C2O4), a complexant that is conducive to follow-on binding of 89Zr through a transchelation process to the deferoxamine siderophore. In the present study, we determined that a lower concentration of H2C2O4 eluent (0.8M) is adequate to efficiently remove 89Zr from a column containing 100mg hydroxamate resin. As a result, less buffering agents are needed to be added to the 89Zr product fraction prior to labeling. A simple automated fluidic system prototype has been developed to perform the steps required for 89Zr purification using a hydroxamate resin column (column conditioning in HCl, Y target dissolution, dissolved target solution load onto column, column washes using HCl and water, and 89Zr elution). The system performance was evaluated using several cyclotron bombarded Y targets; 89Zr product fractions demonstrated excellent chemical recoveries from these targets, with 1.0mL product volumes yielding 89±2% of the column elution peak activity and 84±2% of 89Zr recovered from the target (at EOB). These results compare favorably with previously published 89Zr product volumes and yields, despite the lower concentration of H2C2O4 eluent employed. Transchelation of resulting 89Zr product fractions was performed to assess product quality. The effective specific activity (ESA) ranged between 44(7) and 109(22) TBq·mmole-1, while the bindable metals concentration, a metric introduced for assessing and comparing product purity, ranged between 43(7) and 115(27) nmole·g-1.

4.
Analyst ; 142(18): 3333-3340, 2017 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-28660919

RESUMO

Solid sampling and analysis methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), are challenged by matrix effects and calibration difficulties. Matrix-matched standards for external calibration are seldom available and it is difficult to distribute spikes evenly into a solid matrix as internal standards. While isotopic ratios of the same element can be measured to high precision, matrix-dependent effects in the sampling and analysis process frustrate accurate quantification and elemental ratio determinations. Here we introduce a potentially general solid matrix transformation approach entailing chemical reactions in molten ammonium bifluoride (ABF) salt that enables the introduction of spikes as tracers or internal standards. Proof of principle experiments show that the decomposition of uranium ore in sealed PFA fluoropolymer vials at 230 °C yields, after cooling, new solids suitable for direct solid sampling by LA. When spikes are included in the molten salt reaction, subsequent LA-ICP-MS sampling at several spots indicate that the spikes are evenly distributed, and that U-235 tracer dramatically improves reproducibility in U-238 analysis. Precisions improved from 17% relative standard deviation for U-238 signals to 0.1% for the ratio of sample U-238 to spiked U-235, a factor of over two orders of magnitude. These results introduce the concept of solid matrix transformation (SMT) using ABF, and provide proof of principle for a new method of incorporating internal standards into a solid for LA-ICP-MS. This new approach, SMT-LA-ICP-MS, provides opportunities to improve calibration and quantification in solids based analysis. Looking forward, tracer addition to transformed solids opens up LA-based methods to analytical methodologies such as standard addition, isotope dilution, preparation of matrix-matched solid standards, external calibration, and monitoring instrument drift against external calibration standards.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...