Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Neuroradiol ; 24(4): 347-53, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24132554

RESUMO

PURPOSE: Vertebrobasilar dolichoectasia (VBD) is a rare dilatative arteriopathy predominantly affecting the basilar artery (BA) and vertebral arteries. Until today, the value of computed tomography (CT)/CT angiography (CTA) compared with magnetic resonance imaging (MRI)/time-of-flight MR angiography (TOF-MRA) has not been studied systematically. METHODS: We (1) compare CTA and TOF-MRA according to the established criteria (diameter at the mid-pons level, height, and lateral position), (2) explore the value of further CTA- and TOF-MRA-derived measures (maximum transverse diameter and length), as well as (3) explore the value of further non-contrast-enhanced MRI sequences such as T1, fluid-attenuated inversion recovery, and T2* for a detailed characterization of VBD in a series of 18 patients. RESULTS: Comparison of CTA and TOF-MRA revealed very good consistency of the measured diameter (Pearson's r = 0.994, p = 0.01) and the noted height of the BA (Kendall's tau = 1.0, p = 0.001). The same held true for the maximum transverse diameter (Pearson's r = 0.988, p = 0.01) and length of the BA (Pearson's r = 0.986, p = 0.01). In contrast to this, there was a lower agreement concerning the lateral position (Kendall's tau = 0.866, p = 0.01). In comparison with the diameter at the mid-pons level, the maximum transverse diameter was significantly larger (p = 0.002). Luminal thrombus was detected equally well by CTA and TOF-MRA. CT was useful to detect small circumscribed calcifications, whereas MRI was advantageous to demonstrate perifocal brainstem edema. CONCLUSIONS: We could demonstrate a substantial comparability of CT/CTA and MRI/TOF-MRA in the diagnosis of VBD. The maximum transverse diameter and length may be useful when an endovascular treatment is considered. Taking into account the different informative value of both techniques, it may be worth to perform both imaging procedures.


Assuntos
Angiografia Cerebral/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Insuficiência Vertebrobasilar/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Artéria Basilar/diagnóstico por imagem , Artéria Basilar/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Artéria Vertebral/diagnóstico por imagem , Artéria Vertebral/patologia
2.
Neuroradiology ; 55(1): 49-56, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22932916

RESUMO

INTRODUCTION: Central pontine myelinolysis (CPM) and extrapontine myelinolysis (EPM) are rare neurological disorders characterized by demyelination in and/or outside the pons. Whether diffusion-weighted imaging (DWI) might facilitate an earlier diagnosis has not yet been studied systematically. METHODS: We describe demographics, clinical presentation, and early magnetic resonance imaging (MRI) findings with special emphasis on the relevance for diagnosis of CPM and/or EPM in eight patients. RESULTS: Of the analysed eight patients (aged 37-70 years; two men, six women), CPM was diagnosed in three, EPM in one, and a combination of CPM and EPM in four patients. Aetiology was rapid correction of sodium in two patients; a combination of hyponatremia, alcoholism and alcohol withdrawal in five patients and unclear in one patient. Seven patients suffered from chronic alcoholism and four from malnutrition. Demyelinating lesions were found in the pons, thalamus, caudate nucleus, putamen and midbrain. While the lesions could be clearly delineated on T2- and T1-weighted images, DWI demonstrated a strong signal in only six patients. Furthermore, DWI demonstrated lesions only to some extent in two patients and was completely negative in two patients on initial MRI. In none of the patients did the demonstration of hyperintense lesions on DWI precede detection on conventional MRI sequences. Apparent diffusion coefficient (ADC) values were heterogenous with a decrease in two cases and an increase in the remainder. CONCLUSIONS: We conclude that early DWI changes are a common finding in CPM/EPM but do not regularly precede tissue changes detectable on conventional MRI sequences. Heterogenous ADC values possibly represent different stages of disease.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Mielinólise Central da Ponte/patologia , Ponte/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Clin Neuroradiol ; 22(1): 55-68, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22349435

RESUMO

PURPOSE: Deep-brain stimulation (DBS) of the zona incerta (ZI) has shown promising results for medication-refractory neurological disorders including Parkinson's disease (PD) and essential tremor (ET). The success of the intervention is indispensably dependent on the reliable visualisation of the ZI. The aim of the study was to evaluate different promising new magnetic resonance imaging (MRI) methods at 3.0 Tesla for pre-stereotactic visualisation of the ZI using a standard installation the protocol. METHODS: MRI of nine healthy volunteers was acquired (T1-MPRAGE, T2-FLAIR, T2*-FLASH2D, T2-SPACE and susceptibility-weighted imaging (SWI). Image quality and visualisation of the ZI for each sequence were analysed independently by two neuroradiologists using a 6-point scale. For T2*-FLASH2D the axial, coronal and sagittal planes were compared. The delineation of the ZI versus the internal capsule, the subthalamic nucleus and the pallidofugal fibres was evaluated in all sequences and compared to T2-FLAIR using a paired t-test. Inter-rater reliability, contrast-to-noise ratios (CNR), and signal-to-noise ratios (SNR) for the ZI were computed. For illustration, coronal T2*-FLASH2D images were co-registered with the corresponding section schema of the Schaltenbrand-Wahren stereotactic atlas. RESULTS: Only the rostral part of the ZI (rZI) could be identified. The rZI was best and reliably visualised in T2*-FLASH2D (particularly coronal orientation; p < 0.05). No major artifacts in the rZI were observed in any of the sequences. SWI, T2-SPACE, and T2*-FLASH imaging offered significant higher CNR values for the rZI compared to T2-FLAIR imaging using standard parameters. The co-registration of the coronal T2*-FLASH2D images projected the ZI clearly into the boundaries of the anatomical sections. CONCLUSIONS: The delineation of the rZI is best possible in T2*-FLASH2D (particularly coronal view) using a standard installation protocol at 3.0 T. The caudal ZI could not be discerned in any of the sequences.


Assuntos
Estimulação Encefálica Profunda/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Subtálamo/anatomia & histologia , Adulto , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Subtálamo/cirurgia
5.
Clin Neuroradiol ; 22(1): 47-54, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22286147

RESUMO

PURPOSE: Stent dislocation is a rarely encountered problem in interventional neuroradiology. This article describes the repositioning of a pipeline embolization device (PED) dislocated from the vertebral artery (VA) into the basilar artery (BA) using a stent-in-stent technique. Based on this case additional in vitro measurements were performed. METHODS: In a patient, a larger PED (4.0 × 20 mm) was partially opened in a PED (3.0 × 20 mm) floating freely within the distal BA. The microcatheter with the partially opened stent was pulled back hereby pulling back the stent-in-stent construct into the VA. In vitro the maximum tensile force that could be applied to a 3.5 mm and a 4.5 mm PED before dislodgement out of a 3.0 mm PED was determined. Videomorphometric analyses of the stent-in-stent construct were performed while applying traction to the construct. RESULTS: Repositioning of a dislocated PED is feasible using a stent-in-stent technique. Higher dislodgement forces can be applied using a larger PED (4.5 mm, 0.36 N) whereas dislodgement occurred faster using a smaller PED (3.5 mm, 0.26 N). Before dislodgement occurs, elongation and tapering of both stents can be seen. Finally, it was found that incidental extraction of the 4.5 mm PED out of the delivering microcatheter during traction is possible. CONCLUSIONS: Repositioning of a lost PED is feasible using a stent-in-stent technique. Principally, dislodgement force is higher using a larger PED, while in this case care has to be taken to avoid incidental extraction of the second PED out of the microcatheter.


Assuntos
Artéria Basilar/diagnóstico por imagem , Artéria Basilar/cirurgia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/métodos , Migração de Corpo Estranho/cirurgia , Dissecação da Artéria Vertebral/cirurgia , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Artéria Vertebral/diagnóstico por imagem , Artéria Vertebral/cirurgia , Dissecação da Artéria Vertebral/complicações
6.
Clin Neuroradiol ; 22(1): 29-37, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22270833

RESUMO

PURPOSE: Arterial spin labeling (ASL) is a promising but clinically not established non-invasive method to assess cerebral perfusion. The purpose of this study was to compare perfusion imaging with pulsed ASL (pASL) to conventional dynamic susceptibility contrast (DSC) perfusion-weighted imaging (PWL) using commercially available equipment and postprocessing (3.0 Tesla, 32-channel head coil) in patients with subacute ischemia. METHODS: The pASL and DSC-PWI techniques were compared in 15 patients with subacute ischemia (age 49-88 years, 6 females and 9 males, time from onset to scan 4-161 h). Image inhomogeneity was assessed with the non-uniformity index. Image quality, delineation of hypoperfusion and degree of hypoperfusion were rated by two readers using a 5-scale grading system. The volume of hypoperfusion was quantified planimetrically. RESULTS: Image quality and image inhomogeneity were superior in DSC time-to-peak (TTP) compared to pASL cerebral brain flow (CBF; both p < 0.05). The delineation of hypoperfusion was better in DSC-TTP (p < 0.05) and the hypoperfusion was graded as more severe in DSC-TTP (p < 0.05). The volume of hypoperfusion did not differ between pASL-CBF and DSC-TTP, however, in pASL-CBF five cases with small infarctions (lacunar and pontine) were false negative compared to DSC-relative CBF. The mismatch frequency was lower in pASL (13%) than in DSC-rCBF (20%) and DSC-TTP (47%). CONCLUSIONS: Using a commercially available sequence and a 32-channel head coil at 3.0 Tesla pASL-CBF is feasible but limited compared to DSC-PWI in the assessment of ischemic stroke. In its present form pASL has a reserve role in clinical practice for situations when gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) is contraindicated.


Assuntos
Isquemia Encefálica/patologia , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
7.
Radiologe ; 50(12): 1128-31, 2010 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-21153521

RESUMO

Foreign body ingestion is a common pediatric emergency and if the foreign body cannot be detected radiologically or endoscopically further investigations are required. In this article the case of a radiolucent, ingested foreign body (mini-candleholder of a birthday cake) is presented. The foreign body could not initially be identified via X-ray and endoscopy due to its parapharyngeal localization but was finally visualized by magnetic resonance imaging (MRI) which additionally uncovered the co-existence of acute mediastinal inflammation.


Assuntos
Esôfago , Migração de Corpo Estranho/diagnóstico , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Mediastinite/diagnóstico , Faringe , Proteína C-Reativa/análise , Pré-Escolar , Meios de Contraste , Perfuração Esofágica/diagnóstico , Perfuração Esofágica/patologia , Esôfago/patologia , Feminino , Migração de Corpo Estranho/terapia , Humanos , Laringoscópios , Contagem de Leucócitos , Faringe/patologia , Pneumonia/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...