Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Orthod Sci ; 6(4): 147-151, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29119096

RESUMO

This case report outlines the treatment of a 17-year-old female with Class II Division 1 malocclusion with mandibular retrusion, deep bite, and convex facial profile. The Forsus fatigue resistance device with miniplate was used for this patient and it was very affecting tool in correcting both skeletal and dental parameters. The total active treatment time was 19 months. This method can serve as an alternate choice of treatment, especially those who refuse orthognathic surgery. Hence, Forsus with miniplate might be useful in both growing and postpubertal patients.

4.
J Clin Diagn Res ; 10(12): ZC19-ZC22, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28208997

RESUMO

INTRODUCTION: The self-etching primer system consists of etchant and primer dispersed in a single unit. The etching and priming are merged as a single step leading to fewer stages in bonding procedure and reduction in the number of steps that also reduces the chance of introduction of error, resulting in saving time for the clinician. It also results in smaller extent of enamel decalcification. AIM: To compare the Shear Bond Strength (SBS) of orthodontic bracket bonded with Self-Etch Primers (SEP) and conventional acid etching system and to study the surface appearance of teeth after debonding; etching with conventional acid etch and self-etch priming, using stereomicroscope. MATERIALS AND METHODS: Five Groups (n=20) were created randomly from a total of 100 extracted premolars. In a control Group A, etching of enamel was done with 37% phosphoric acid and bonding of stainless steel brackets with Transbond XT (3M Unitek, Monrovia, California). Enamel conditioning in left over four Groups was done with self-etching primers and adhesives as follows: Group B-Transbond Plus (3M Unitek), Group C Xeno V+ (Dentsply), Group D-G-Bond (GC), Group E-One-Coat (Coltene). The Adhesive Remnant Index (ARI) score was also evaluated. Additionally, the surface roughness using profilometer were observed. RESULTS: Mean SBS of Group A was 18.26±7.5MPa, Group B was 10.93±4.02MPa, Group C was 6.88±2.91MPa while of Group D was 7.78±4.13MPa and Group E was 10.39±5.22MPa respectively. In conventional group ARI scores shows that over half of the adhesive was remaining on the surface of tooth (score 1 to 3). In self-etching primer groups ARI scores show that there was no or minor amount of adhesive remaining on the surface of tooth (score 4 and 5). SEP produces a lesser surface roughness on the enamel than conventional etching. However, statistical analysis shows significant correlation (p<0.001) of bond strength with surface roughness of enamel. CONCLUSION: All groups might show clinically useful SBS values and Transbond XT can be successfully used for bracket bonding after enamel conditioning with any of the SEPs tested. The SEPs used in Groups C (Xeno V+) and D (G-Bond) have significantly lowered SBS. Although, the values might still be clinically acceptable.

5.
J Clin Diagn Res ; 9(8): ZH01-2, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26436067

RESUMO

In fixed orthodontic treatment, for the cinch back purpose, there is need of annealing of distal end of NiTi arch wire. During this procedure the area or length to be annealed is difficult to control. This inappropriate heating leads to deleterious effect on property of the wire. To prevent this problem a simple economical and efficient device was prepared that prevents annealing of excessive length of wire and thus prevents the deterioration of wire required for appropriate action.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...