Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Aerosol Med Pulm Drug Deliv ; 36(3): 89-100, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37062763

RESUMO

Background: This study examined the effect of age and head position on total and regional deposition of aerosol delivered by a mucosal atomization device (MAD™) in three-dimensional (3D) models of the intranasal airways of an 18-, 5-, and 2-year-old human. Models consisted of four pieces: anterior nose and nasal cavity that was divided horizontally into upper, middle, and lower thirds. Methods: Models were tested six times at supine, supine with head backward at 45° (supine45), and sitting with head backward at 45° (sitting45). The MAD delivered saline/fluorescein aerosol into model nostrils, during static airflow. Model pieces were tested for fluorescence using a fluorometer, and deposition calculated as percent fluorescence per piece relative to its reference. Total deposition (four pieces combined) and regional deposition (four pieces separately) were calculated. Results: Age and head position had little effect on total deposition. In contrast, deposition in the upper and middle third supine45 and in the lower third sitting45 was significantly different in the 2-year-old model, compared with the two older models. In addition, some head positions significantly increased deposition in the upper, middle, and lower thirds within each model, compared with other positions. Upper deposition was significantly greater at supine45, compared with sitting45 (18-year-old) and supine45, compared with supine and sitting45 (5-year-old). Middle deposition was significantly greater at supine and supine45, compared with sitting45 (2-year-old). Lower deposition was significantly greater at sitting45, compared with supine45 (18-year-old); supine and sitting45, compared with supine45 (5-year-old); and sitting45, compared with supine45 and supine (2-year-old). Conclusions: Age and head position significantly affected regional deposition of aerosol delivered by the MAD in these 3D models. Such models might be used to study other methods for targeting intranasal regions with aerosolized medications in children and adults.


Assuntos
Pulmão , Cavidade Nasal , Criança , Adulto , Humanos , Pré-Escolar , Adolescente , Administração por Inalação , Administração Intranasal , Aerossóis
2.
Am J Disaster Med ; 17(1): 13-21, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35913180

RESUMO

Most chemical or biological decontamination protocols have been driven by the need for fast and efficient methods that are relatively safe and easy to implement. As such, the focus has primarily been toward "general" environments-those in which water is readily available, and the ambient conditions are amenable to such techniques. Some of these include water showers and/or sprays with chemical decontaminants, eg, soapy water or diluted bleach. However, there exist some scenarios in which water-based decontamination methods are not desirable. These include such operational environments as arid regions (water scarcity), specialized operations (decontamination method must be low volume/weight), and cold weather (freezing risk). This study focuses on the cold weather challenge: identification of common methods for readily available decontamination and evaluation of their respective efficacies. Methods evaluated include wiping (with wet and dry wipes), blotting with moistened wipes, vacuuming, and the application and removal of adhesive tape. Results demonstrate that vacuuming and blotting (without overlapping targeted regions) are generally less effective than other wiping, blotting, and adhesive tape-based measures at removing bacteria from surfaces.


Assuntos
Temperatura Baixa , Descontaminação , Descontaminação/métodos , Água
3.
J Occup Environ Hyg ; 15(3): 235-245, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29283321

RESUMO

Conventional wisdom has been that hard, resilient surfaces resuspend fewer particles than carpeted surfaces, however, exceptions to this have been demonstrated and uncertainty remains about the factors that lead to this resuspension, notably, the effect of vacuum cleaning on either increasing or reducing resuspension from flooring. The purpose of this study was to determine how resuspension of house dust by aerodynamic size or particle type, including cat allergen and bacterial endotoxin, is affected by flooring, dust loading, embedding dust, and walking/cleaning activities. House dust was blown in and allowed to settle in a walk-in chamber after overnight deposition followed by walking or a vacuum cleaning procedure. Using an aerosol particle sizer and large-volume air samplers at different heights in the chamber, concentrations of airborne particles, resuspension rates, and fractions were computed for four types of flooring conditions during six walking activities. Carpeting resulted in significantly more airborne cat allergen and airborne endotoxin than a laminate floor. Height does have an effect on measured allergen over carpet and this is apparent with concentrations at the infant and adult air samplers. Walking on laminate flooring resuspends less house dust than walking on an equally dusty carpeted floor, where dust is entirely on the surface of the carpet. However, vacuum cleaning a laminate floor resuspended more dust than vacuum cleaning carpets, at large particle sizes of 5 µm and 10 µm. Activities following a deep cleaning of hard resilient or a carpeted surface is likely to leave no differences in resuspended particles between them.


Assuntos
Alérgenos/análise , Poeira/análise , Pisos e Cobertura de Pisos , Zeladoria/métodos , Caminhada , Poluição do Ar em Ambientes Fechados/análise , Animais , Gatos , Endotoxinas/análise , Humanos , Tamanho da Partícula
4.
J Forensic Sci ; 61(6): 1639-1642, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27539663

RESUMO

Previous studies have shown a significant amount of contaminants on paper currencies. It is important to study the transfer of microorganisms between paper currencies to determine whether it meets the level of a human health threat. This cross-contamination potential was analyzed by seeding new US 1-dollar bills with Bacillus thuringiensis, and pressing or rubbing them against clean currency to determine the amount of bacteria transfer to the unseeded currency. The transferred amount of bacteria was recovered, plated, incubated, and the colony-forming units were quantified. Among the recovery methods tested, the most efficient method, vortexing for 10 min with a recovery efficiency of 40 ± 8.1%, was used in this analysis. The resulting transfer rates were 4.8%, 8.6%, and 14.3% when pressed for 24 h, 72 h, and rubbed together, respectively. These transferred amounts of bacteria are significant and have the potential to spread infectious diseases.


Assuntos
Bactérias/isolamento & purificação , Papel , Comércio , Humanos
5.
Environ Sci Process Impacts ; 17(3): 638-45, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25631321

RESUMO

Humans contract a variety of serious diseases through inhalation of infectious aerosols. Thus, the importance of monitoring air for microbial, toxic, or allergic content is recognized in clinical, occupational, and biodefense arenas. However, accurate monitoring of potentially contaminated environments can be hampered by selection of aerosol samplers with inadequate performance for the intended task. In this study, 29 aerosol samplers were evaluated based on their respective air flow, size, weight, power consumption, and efficiency in sampling particles in the respirable range. The resulting data demonstrates that sampling air flow and efficiency vary widely, and cannot be predicted from the physical characteristics of air samplers, and hence, that proper selection of air samplers should be more involved than shopping for a device based on the limited characteristics that are published by the manufacturers. The findings are summarized in an approach to rationally select bioaerosol samplers for use in infection control and environmental biomonitoring. The presented data demonstrates that inadequate selection of air samplers could result in a failure to collect particles of interest and thus, underestimate the risk and provide a false sense of security in contaminated health care settings and environments contaminated with infectious or toxic aerosols.


Assuntos
Aerossóis/análise , Monitoramento Ambiental/instrumentação , Poluentes Ocupacionais do Ar/análise , Desenho de Equipamento , Filtração , Humanos , Exposição por Inalação/análise , Exposição Ocupacional/análise , Tamanho da Partícula
6.
J Environ Monit ; 12(10): 1807-14, 2010 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-20676427

RESUMO

In this paper, we describe the design, development and characterization of a high-volume sequential cyclone system for the collection of size-segregated PM in dry bulk form from the ambient environment in sufficient quantity for physical, chemical and toxicological characterization. The first stage of the system consists of a commercially available high volume PM(10) inlet. The second stage cyclone was designed by us to collect inhalable coarse particles (<10 µm and >2.5 µm). When tested individually with a challenge aerosol, a D(50) cut-size of this stage was found to be 2.3 µm at a flow rate of 1 m(3) min(-1). The third stage, a commercially available cyclone designed for surface dust sampling, had a D(50) cut-size of 0.3 µm when tested at the same flow rate. The purpose of the third stage is to collect the fine particle portion of PM(2.5) or accumulation mode (PM <2.5 µm and >0.1 µm). Thus, the sequential cyclone system will collect bulk samples of both the inhalable coarse particles and the fine particle portion of PM(2.5). The operation and maintenance of the new system are straightforward and allow for reliable collection of dry bulk ambient PM at relatively low cost.


Assuntos
Monitoramento Ambiental/instrumentação , Poluentes Ambientais/análise , Material Particulado/análise , Desenho de Equipamento , Tamanho da Partícula
7.
Environ Sci Technol ; 41(7): 2467-72, 2007 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-17438801

RESUMO

Exposure assessment of biological aerosols requires trade-offs between efficient sampling of airborne microorganisms as either particles or viable units. The main objective of this work was to characterize aspects of bioaerosol measurement efficiency. A known concentration of the vegetative bacteria Pantoea agglomerans was spiked onto different samplers (AGI-30, BioSampler, and membrane filters) and then run for increasing time periods using HEPA filtered air. Measurement efficiency was evaluated based on total, viable, and culturable counts. Total and viable counts were determined by flow-cytometry (FCM); culturable counts were evaluated by standard plating. FCM as a method for assaying viability showed excellent agreement with known proportions of live/dead organisms (slope = 0.82, R(2) = 0.99). P. agglomerans recoveries (total, viable, and culturable) in order of best sampler performance included the BioSampler (75%, 52%, and 50%), filtration (50%, 13%, and 2%), and the AGI-30 (<30%, 15%, and 5%). The difference between viability and culturability provided an indication of viable but nonculturable (VBNC) cells. VBNC efficiency for sampling by filter, AGI-30, and BioSampler was 80%, 50%, and 100%, respectively. This research helps characterize recovery, survival, and culturability efficiencies while sampling environmentally sensitive airborne bacteria for purposes of exposure assessment, epidemiologic studies, and homeland security.


Assuntos
Aerossóis/análise , Microbiologia do Ar , Atmosfera/análise , Monitoramento Ambiental/métodos , Citometria de Fluxo/métodos , Pantoea/isolamento & purificação
8.
J Allergy Clin Immunol ; 109(5): 794-9, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-11994702

RESUMO

BACKGROUND: Montelukast is a leukotriene antagonist approved for the treatment of childhood asthma in children age 2 years and older. There are limited studies on its effects on allergic asthma in children. OBJECTIVE: We sought to evaluate montelukast's effects on upper and lower airway responses to intense cat allergen exposure. METHODS: In a double-blind, placebo-controlled, cross-over trial 18 subjects aged 6 to 14 years with cat-induced asthma were randomly assigned to receive 1 week each of either montelukast or placebo, followed by a 1-hour cat challenge in an environmental exposure unit. Upper and lower respiratory tract symptoms were rated, and spirometry and acoustic rhinometry were performed. Challenges were stopped early if the subject became too uncomfortable or had a greater than 50% decrease in FEV1. RESULTS: Overall changes in FEV1 were significantly different with montelukast treatment and remained significant after adjusting for allergen level (P =.02; adjusted P =.01). Lower respiratory tract symptom scores were significantly reduced with montelukast versus placebo (P =.007) but lost significance after adjusting for allergen level (P =.16). Challenge length was significantly longer with montelukast versus placebo (P <.001) and remained significant after adjusting for allergen level (P =.019). Montelukast did not significantly affect upper respiratory responses, as measured by means of symptom scores (P =.43) and changes in acoustic rhinometry (P =.078). CONCLUSIONS: Montelukast was significantly more effective than placebo in attenuating lower respiratory responses and extending challenge length when cat-sensitive children with mild persistent asthma were exposed to high levels of cat allergen.


Assuntos
Acetatos/uso terapêutico , Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Asma/imunologia , Glicoproteínas/imunologia , Quinolinas/uso terapêutico , Adolescente , Asma/fisiopatologia , Criança , Estudos Cross-Over , Ciclopropanos , Método Duplo-Cego , Feminino , Volume Expiratório Forçado/efeitos dos fármacos , Humanos , Masculino , Sistema Respiratório/fisiopatologia , Sulfetos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...