Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neurosci Res ; 101(12): 1814-1825, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37688406

RESUMO

Pannexin 1 (Panx1) forms ATP-permeable membrane channels that play roles in purinergic signaling in the nervous system. A link between Panx1 activity and neurodegenerative disorders including Parkinson's disease (PD) has been suggested, but experimental evidence is limited. Here, a zebrafish model of PD was produced by exposing panx1a+/+ and panx1a-/- zebrafish larvae to 6-hydroxydopamine (6-OHDA). Electrical stimulation in a microfluidic chip and quantitative real-time-qPCR of zebrafish larvae tested the role of Panx1 in both pathological and normal conditions. After 72-h treatment with 6-OHDA, the electric-induced locomotor activity of 5 days post fertilization (5dpf) panx1a+/+ larvae were reduced, while the stimulus did not affect locomotor activity of age-matched panx1a-/- larvae. A RT-qPCR analysis showed an increase in the expression of genes that are functionally related to dopaminergic signaling, like the tyrosine hydroxylase (th2) and the leucine-rich repeat kinase 2 (lrrk2). Extending the 6-OHDA treatment duration to 120 h caused a significant reduction in the locomotor response of 7dpf panx1a-/- larvae compared to the untreated panx1a-/- group. The RT-qPCR data showed a reduced expression of dopaminergic signaling genes in both genotypes. It was concluded that the absence of Panx1a channels compromised dopaminergic signaling in 6-OHDA-treated zebrafish larvae and that the increase in the expression of dopaminergic genes was transient, most likely due to a compensatory upregulation. We propose that zebrafish Panx1a models offer opportunities to shed light on PD's physiological and molecular basis. Panx1a might play a role on the progression of PD, and therefore deserves further investigation.

2.
Integr Biol (Camb) ; 14(7): 162-170, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36416255

RESUMO

Multi-phenotypic screening of multiple zebrafish larvae plays an important role in enhancing the quality and speed of biological assays. Many microfluidic platforms have been presented for zebrafish phenotypic assays, but multi-organ screening of multiple larvae, from different needed orientations, in a single device that can enable rapid and large-sample testing is yet to be achieved. Here, we propose a multi-phenotypic quadruple-fish microfluidic chip for simultaneous monitoring of heart activity and fin movement of 5-7-day postfertilization zebrafish larvae trapped in the chip. In each experiment, fin movements of four larvae were quantified in the dorsal view in terms of fin beat frequency (FBF). Positioning of four optical prisms next to the traps provided the lateral views of the four larvae and enabled heart rate (HR) monitoring. The device's functionality in chemical testing was validated by assessing the impacts of ethanol on heart and fin activities. Larvae treated with 3% ethanol displayed a significant drop of 13.2 and 35.8% in HR and FBF, respectively. Subsequent tests with cadmium chloride highlighted the novel application of our device for screening the effect of heavy metals on cardiac and respiratory function at the same time. Exposure to 5 $\mu$g/l cadmium chloride revealed a significant increase of 8.2% and 39.2% in HR and FBF, respectively. The device can be employed to monitor multi-phenotypic behavioral responses of zebrafish larvae induced by chemical stimuli in various chemical screening assays, in applications such as ecotoxicology and drug discovery.


Assuntos
Microfluídica , Peixe-Zebra , Animais , Larva , Cloreto de Cádmio , Etanol
3.
Biotechnol J ; 17(6): e2100561, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35332995

RESUMO

Electrical stimulation of brain or muscle activities has gained attention for studying the molecular and cellular mechanisms involved in electric-induced responses. We recently showed zebrafish's response to electricity. Here, we hypothesized that this response is affected by the dopaminergic signaling pathways. The effects of multiple dopamine agonists and antagonists on the electric response of 6 days-postfertilization zebrafish larvae were investigated using a microfluidic device with enhanced control of experimentation and throughput. All dopamine antagonists decreased locomotor activities, while dopamine agonists did not induce similar behaviors. The D2-selective dopamine agonist quinpirole enhanced the movement. Exposure to nonselective and D1-selective dopamine agonists apomorphine and SKF-81297 caused no significant change in the electric response. Exposing larvae that were pretreated with nonselective and D2-selective dopamine antagonists butaclamol and haloperidol to apomorphine and quinpirole, respectively, restored the electric locomotion. These results reveal a correlation between electric response and dopamine signaling pathway. Furthermore, they demonstrate that electric-induced zebrafish larvae locomotion can be conditioned by modulating dopamine receptor functions. Our electrofluidic assay has profound application potential for fundamental electric-induced response research and brain disorder studies especially those related to the dopamine imbalance and as a chemical screening method when investigating biological pathways and behaviors.


Assuntos
Dopamina , Peixe-Zebra , Animais , Apomorfina/farmacologia , Dopamina/metabolismo , Dopamina/farmacologia , Agonistas de Dopamina/farmacologia , Antagonistas de Dopamina/farmacologia , Eletricidade , Larva/metabolismo , Quimpirol/farmacologia , Transdução de Sinais , Peixe-Zebra/metabolismo
4.
Biotechnol J ; 17(1): e2100076, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34480402

RESUMO

BACKGROUND: Microfluidic devices are being used for phenotypic screening of zebrafish larvae in fundamental and pre-clinical research. A challenge for the broad use of these microfluidic devices is their low throughput, especially in behavioral assays. Previously, we introduced the tail locomotion of a semi-mobile zebrafish larva evoked on-demand with electric signal in a microfluidic device. Here, we report the lessons learned for increasing the number of specimens from one to four larvae in this device. METHODS AND RESULTS: Multiple parameters including loading and testing time per fish and loading and orientation efficiencies were refined to optimize the performance of modified designs. Flow and electric field simulations within the final device provided insight into the flow behavior and functionality of traps when compared to previous single-larva devices. Outcomes led to a new design which decreased the testing time per larva by ≈60%. Further, loading and orientation efficiencies increased by more than 80%. Critical behavioral parameters such as response duration and tail beat frequency were similar in both single and quadruple-fish devices. CONCLUSION: The developed microfluidic device has significant advantages for greater throughput and efficiency when behavioral phenotyping is required in various applications, including chemical testing in toxicology and gene screening.


Assuntos
Dispositivos Lab-On-A-Chip , Peixe-Zebra , Animais , Larva
5.
Comput Biol Med ; 132: 104314, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33774273

RESUMO

In this paper, the heartbeat parameters of small model organisms, i.e. Drosophila melanogaster (fruit fly) and Danio rerio (zebrafish), were quantified in-vivo in intact larvae using microfluidics and a novel MATLAB-based software. Among different developmental stages of flies and zebrafish, the larval stage is privileged due to biological maturity, optical accessibility, and the myogenic nature of the heart. Conventional methods for parametric quantification of heart activities are complex and mostly done on dissected, irreversibly immobilized, or anesthetized larvae. Microfluidics has helped with reversible immobilization without the need for anesthesia, but heart monitoring is still done manually due to challenges associated with the movement of floating organs and cardiac interruptions. In our MATLAB software applied to videos recorded in microfluidic-based whole-organism assays, we have used image segmentation to automatically detect the heart and extract the heartbeat signal based on pixel intensity variations of the most contractile region of the heart tube. The smoothness priors approach (SPA) was applied to remove the undesired low-frequency noises caused by environmental light changes or heart movement. Heart rate and arrhythmicity were automatically measured from the detrended heartbeat signal while other parameters including end-diastolic and end-systolic diameters, shortening distance, shortening time, fractional shortening, and shortening velocity were quantified for the first time in intact larvae, using M-mode images under bright field microscopy. The software was able to detect more than 94% of the heartbeats and the cardiac arrests in intact Drosophila larvae. Our user-friendly software enables in-vivo quantification of D. melanogaster and D. rerio larval heart functions in microfluidic devices, with the potential to be applied to other biological models and used for automatic screening of drugs and alleles that affect their heart.


Assuntos
Dispositivos Lab-On-A-Chip , Peixe-Zebra , Acesso à Informação , Animais , Drosophila , Drosophila melanogaster , Larva
6.
Integr Biol (Camb) ; 12(8): 211-220, 2020 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-32877926

RESUMO

Multi-phenotypic screening of zebrafish larvae, such as monitoring the heart and tail activities, is important in biological assays. Microfluidic devices have been developed for zebrafish phenotypic assays, but simultaneous lateral-dorsal screening of the same larva in a single chip is yet to be achieved. We present a multi-phenotypic microfluidic device for monitoring of tail movement and heart rate (HR) of 5-7-day postfertilization zebrafish larvae. Tail movements were stimulated using electric current and quantified in terms of response duration (RD) and tail beat frequency (TBF). The positioning of a right-angle prism provided a lateral view of the larvae and enabled HR monitoring. Investigations were performed on zebrafish larvae exposed to 3% ethanol, 250 µM 6-hydroxydopamine (6-OHDA) or 1 mM levodopa. Larvae exposed to ethanol showed a significant drop in HR, whereas electric stimulation increased the HR temporarily. Larvae experienced a significant drop in RD, TBF and HR when exposed to 6-OHDA. HR was not affected by levodopa post-treatment, whereas RD and TBF were restored to normal levels. The results showed potential for applications that involve monitoring of cardiac and behavioral parameters in zebrafish larvae. Tests can be done using the same chip, without changing the larvae's orientation. This eliminates undue stress caused by reorientation, which may affect their behavior, and the use of separate devices to obtain dorsal and lateral views. The device can be implemented to improve multi-phenotypic and quantitative screening of zebrafish larvae in response to chemical and physical stimuli in different zebrafish disease models.


Assuntos
Comportamento Animal , Estimulação Elétrica , Dispositivos Lab-On-A-Chip , Larva/fisiologia , Peixe-Zebra/embriologia , Criação de Animais Domésticos , Animais , Desenho de Equipamento , Frequência Cardíaca , Processamento de Imagem Assistida por Computador , Microfluídica , Movimento , Fenótipo
7.
Integr Biol (Camb) ; 11(10): 373-383, 2019 12 31.
Artigo em Inglês | MEDLINE | ID: mdl-31851358

RESUMO

Behavioral responses of zebrafish larvae to environmental cues are important functional readouts that should be evoked on-demand and studied phenotypically in behavioral, genetical and developmental investigations. Very recently, it was shown that zebrafish larvae execute a voluntary and oriented movement toward the positive electrode of an electric field along a microchannel. Phenotypic characterization of this response was not feasible due to larva's rapid movement along the channel. To overcome this challenge, a microfluidic device was introduced to partially immobilize the larva's head while leaving its mid-body and tail unrestrained in a chamber to image motor behaviors in response to electric stimulation, hence achieving quantitative phenotyping of the electrically evoked movement in zebrafish larvae. The effect of electric current on the tail-beat frequency and response duration of 5-7 days postfertilization zebrafish larvae was studied. Investigations were also performed on zebrafish exposed to neurotoxin 6-hydroxydopamine and larvae carrying a pannexin1a (panx1a) gene knockout, as a proof of principle applications to demonstrate on-demand movement behavior screening in chemical and mutant assays. We demonstrated for the first time that 6-hydroxydopamine leads to electric response impairment, levodopa treatment rescues the response and panx1a is involved in the electrically evoked movement of zebrafish larvae. We envision that our technique is broadly applicable as a screening tool to quantitatively examine zebrafish larvae's movements in response to physical and chemical stimulations in investigations of Parkinson's and other neurodegenerative diseases, and as a tool to combine recent advances in genome engineering of model organisms to uncover the biology of electric response.


Assuntos
Análise Mutacional de DNA , Estimulação Elétrica , Mutação , Peixe-Zebra/embriologia , Animais , Animais Geneticamente Modificados , Comportamento Animal , Conexinas/genética , Dispositivos Lab-On-A-Chip , Levodopa/farmacologia , Oxidopamina/toxicidade , Fenótipo , Fatores de Risco , Proteínas de Peixe-Zebra/genética
8.
Brief Funct Genomics ; 18(6): 419-432, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31034029

RESUMO

Zebrafish or Danio rerio is an established model organism for studying the genetic, neuronal and behavioral bases of diseases and for toxicology and drug screening. The embryonic and larval stages of zebrafish have been used extensively in fundamental and applied research due to advantages offered such as body transparency, small size, low cost of cultivation and high genetic homology with humans. However, the manual experimental methods used for handling and investigating this organism are limited due to their low throughput, labor intensiveness and inaccuracy in delivering external stimuli to the zebrafish while quantifying various neuronal and behavioral responses. Microfluidic and lab-on-a-chip devices have emerged as ideal technologies to overcome these challenges. In this review paper, the current microfluidic approaches for investigation of behavior and neurobiology of zebrafish at embryonic and larval stages will be reviewed. Our focus will be to provide an overview of the microfluidic methods used to manipulate (deliver and orient), immobilize and expose or inject zebrafish embryos or larvae, followed by quantification of their responses in terms of neuron activities and movement. We will also provide our opinion in terms of the direction that the field of zebrafish microfluidics is heading toward in the area of biomedical engineering.


Assuntos
Dispositivos Lab-On-A-Chip , Procedimentos Analíticos em Microchip , Modelos Animais , Peixe-Zebra/embriologia , Peixe-Zebra/crescimento & desenvolvimento , Animais , Engenharia Biomédica/métodos , Engenharia Biomédica/tendências , Embrião não Mamífero , Larva , Procedimentos Analíticos em Microchip/métodos , Procedimentos Analíticos em Microchip/tendências , Peixe-Zebra/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...