Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Hypertens ; 25: 8, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30984413

RESUMO

BACKGROUND: Every third patient in the clinic is misdiagnosed due to white-coat phenomenon, necessitating needless and costly treatment. We aimed to study the hemodynamic response of the physician's visit on hypertensive and normotensive patients by investigating the trend of blood pressure (BP) before, during and 15 min after the physician-patient encounter. METHODS: A descriptive, cross-sectional study was conducted over a period of 8 months in the cardiology clinics at the Aga Khan University Hospital, Karachi. Both hypertensive and normotensive patients, aged ≥18 years, were recruited. Pregnant females or those with a history of volume loss were excluded. BP readings were taken using an automated, validated device (Omron-HEM7221-E) at three points: pre-clinic BP by the assessment nurse, in-clinic BP by the attending physician and post-clinic BP 15-min after the physician-patient encounter by a research assistant. Independent samples t-test was used to calculate the statistical difference between hypertensive and normotensive BP values. RESULTS: Of 180 participants, 71% (n = 128) were hypertensive and 57% (n = 103) of all were males. The mean age of the participants was 57 ± 15 years. The mean and standard deviation(±SD) systolic BP (SBP) taken pre-clinic, in-clinic and 15-min post-clinic for hypertensive population was 128.7 ± 20 mmHg, 137.1 ± 21 mmHg and 127.9 ± 19 mmHg. The mean and standard deviation(±SD) SBP taken pre-clinic, in-clinic and 15 min post-clinic for normotensive population was 112 ± 16 mmHg, 115.8 ± 20 mmHg and 111.8 ± 15 mmHg. The hypertensive SBP values showed statistically significant difference from the normotensive values (difference in pre-clinic SBP: 16.7 mmHg, p-value < 0.001; in-clinic SBP: 21.3 mmHg, p-value < 0.001; and 15 min post-clinic: 16.1 mmHg, p-value < 0.001). CONCLUSIONS: Hypertensive and normotensive patients display congruent hemodynamics upon visiting the physician, the alert response being accentuated amongst the hypertensive group. In-clinic BP readings are higher for both hypertensive and normotensive patients making them unreliable for screening and management of hypertension amongst both the groups.

2.
BMC Res Notes ; 11(1): 460, 2018 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-29996947

RESUMO

OBJECTIVE: Our previous study showed that post-clinic blood pressure (BP) taken 15 min after a physician-patient encounter was the lowest reading in a routine clinic. We aimed to validate this reading with 24 h Ambulatory Blood Pressure Monitoring (ABPM) readings. A cross-sectional study was conducted in the cardiology clinics at the Aga Khan University, Pakistan. Hypertensive patients aged ≥ 18 years, or those referred for the diagnosis of hypertension were included. RESULTS: Of 150 participants, 49% were males. 76% of all participants were hypertensive. Pre-clinic BP reading was measured by a nurse, in-clinic by a physician and 15 min post-clinic by a research assistant using a validated, automated BP device (Omron-HEM7221-E). All patients were referred for 24 h ABPM. Among the three readings taken during a clinic visit, mean (± SD) systolic BP (SBP) pre-clinic, in-clinic, and 15 min post-clinic were 153.2 ± 23, 152.3 ± 21, and 140.0 ± 18 mmHg, respectively. Mean (± SD) diastolic BP (DBP) taken pre-clinic, in-clinic and 15 min post-clinic were 83.5 ± 12, 90.9 ± 12, and 86.4 ± 11 mmHg respectively. Mean (± SD) daytime ambulatory SBP, DBP and pulse readings were 134.7 ± 15, 78.7 ± 15 mmHg, and 72.6 ± 12/min, respectively. Pearson correlation coefficients of pre-clinic, in-clinic and post-clinic SBP with daytime ambulatory-SBP were 0.4 (p value: < 0.001), 0.5 (p value: < 0.001) and 0.6 (p value: < 0.001), respectively. Post-clinic BP has a good correlation with ambulatory BP and may be considered a more reliable reading in the clinic setting.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Hipertensão/diagnóstico , Adolescente , Adulto , Determinação da Pressão Arterial , Estudos Transversais , Feminino , Humanos , Masculino , Paquistão
3.
J Coll Physicians Surg Pak ; 25(3): 206-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25772963

RESUMO

OBJECTIVE: To determine the difference in Blood Pressure (BP) readings taken before, during and after the clinic encounter. STUDY DESIGN: Descriptive study. PLACE AND DURATION OF STUDY: Cardiology Clinic, The Aga Khan University Hospital, Karachi, from January to August 2013. METHODOLOGY: Hypertensive and normotensive participants aged ³ 18 years were recruited. Pre-clinic BP was measured by a nurse and in-clinic BP by a physician. After 15 minutes, two post-clinic BP readings were taken at 1 minute interval. All readings were taken using Omron HEM7221-E. RESULTS: Out of 180 participants, males were 57% and 130 (71%) were hypertensive. Mean SBP (Systolic BP) taken preclinic, in-clinic, post-clinic 1 and post-clinic 2 were: 126 ± 20 mmHg, 131 ± 23 mmHg, 126 ± 20 mmHg and 121 ± 21 mmHg respectively (p < 0.001). Mean DBP (Diastolic BP) taken pre-clinic, in-clinic, post-clinic 1 and post-clinic 2 were 77 ± 12 mmHg, 81 ± 13 mmHg, 79 ± 12 mmHg and 79 ± 11 mmHg respectively (p < 0.001). CONCLUSION: BP taken in the post-clinic setting may significantly be the lowest reading in a clinic encounter, making in-clinic BP unreliable to diagnose or manage hypertension.


Assuntos
Assistência Ambulatorial , Determinação da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Hipertensão/diagnóstico , Visita a Consultório Médico , Adulto , Idoso , Determinação da Pressão Arterial/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Relações Médico-Paciente , Médicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...