Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Neurol Neurosurg ; 231: 107792, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37307711

RESUMO

The SAMMPRIS Trial concluded that medical treatment of intracranial stenosis was safer than intracranial stenting. The key reasons for a poor outcome with stenting were significantly more perioperative ischemic strokes and higher rates of intracerebral hemorrhages. To the contrary, WEAVE trial showed significantly lower morbidity and mortality when stenting was performed one week following the ictus. We describe the technical approach for safe basilar artery stenting through radial approach. A middle aged male presented with recurrent posterior circulation symptoms despite being on dual antiplatelet therapy. A right radial approach was undertaken. A 5f radial sheath was exchanged for an AXS infinity LS (Stryker Neurovascular, Ireland) 6 f sheath after priming the radial artery. Using a quadri-axial approach, 0.014' Traxcess microwire (Microvention Inc, Tustin, USA), 0.017' Echelon microcatheter (Microtherapeutics.inc. Ev3 Neurovascular, USA), 0.038 DAC (Stryker Neurovascular USA) & 5F Navien (Microtherapeutics.inc. Ev3 USA), the Infinity sheath was taken into the V2 segment of the right vertebral artery. The 5F Navien (tri-axial approach) was taken upto the distal V4 segment of the vertebral artery. The 3d rotational angiography directed runs revealed > 95 % stenosis of mid basilar segment. No significant ostial stenosis of side branch was noted and in view of long segment plaque angioplasty followed by deployment of self-expanding stent was planned. The microcatheter (0.017') and microwire (Traxcess 0.014') was navigated across the stenosis. Thereafter, an exchange maneuver was performed to allow for sequential slow balloon angioplasty with 1.5 mm × 15 (Maverick, Boston Scientific) and 2.5 mm× 15 (Trek, Abbott costa rica) coronary balloon. Following that a CREDO 4 × 20 mm stent (Acandis GmbH., Pforzheim Germany) was deployed across the stenosis. All exchange maneuvers were performed under biplane fluoroscopy and microwire was kept under watch. The patient was on aspirin and clopidogrel and activated clotting time was maintained around 250 s throughout the procedure. A closure device was applied post procedure. Blood pressure was monitored in neurointensive care unit and patient was discharged on the third day following procedure. Right radial approach, distal position of the sheath, distal position of the guiding catheter, careful analysis of the 3d rotational angiography for risk of side branch occlusion, biplane fluoroscopy during exchanges and slow angioplasty were the key safety checks during procedure.


Assuntos
Acidente Vascular Cerebral , Insuficiência Vertebrobasilar , Pessoa de Meia-Idade , Humanos , Masculino , Constrição Patológica , Acidente Vascular Cerebral/cirurgia , Angioplastia , Insuficiência Vertebrobasilar/diagnóstico por imagem , Insuficiência Vertebrobasilar/cirurgia , Hemorragia Cerebral , Stents , Artéria Basilar , Resultado do Tratamento
2.
Thorac Cardiovasc Surg ; 70(7): 589-595, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35263793

RESUMO

OBJECTIVES: The objective of this study was to present the procedural details and digital subtraction angiography (DSA) findings of perioperative chest-wall collateral embolization (PCCE) and compare intraoperative blood loss in patients of pulmonary aspergilloma (PA) undergoing lung resection with and without PCCE. MATERIALS AND METHODS: Since November 2017, we have performed PCCE in 17 patients (14 males, three females, age 34.41 ± 12.85 years) before surgery for PA (embolization group). Retrospective evaluation of these patients was done, DSA findings were noted, and perioperative parameters (surgical approach, extent of resection, operative time, blood loss, blood transfusion, morbidity grade, and length of post-operative stay) were compared with a comparative cohort of 24 patients of PA (21 males, three females, mean age 36.13 ± 12.58 years) who underwent thoracic surgery without PCCE (May 2013-November 2017) (control group) using the Mann-Whitney U test. RESULTS: A total of 55 arteries were embolized in 17 patients (mean 3.23 arteries per patient). Technical success could be achieved in all patients without any procedure-related complications. The most common arteries embolized were posterior intercostal arteries (29) followed by costocervical trunk (10), superior thoracic (8), lateral thoracic (5), and internal thoracic arteries (3). The mean blood loss was significantly lower in the embolization group compared with the control group (676.47 vs. 1,264.58 mL, p = 0.015). Within the embolization group, patients who underwent video-assisted thoracoscopic surgery had even lower blood loss compared with open surgery cases (466 vs. 887.50 mL, p-value = 0.046). CONCLUSION: PCCE is a simple and safe procedure, useful in reducing intra-operative blood loss in patients undergoing surgery for peripherally located PA.


Assuntos
Perda Sanguínea Cirúrgica , Embolização Terapêutica , Adulto , Perda Sanguínea Cirúrgica/prevenção & controle , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Cirurgia Torácica Vídeoassistida/efeitos adversos , Cirurgia Torácica Vídeoassistida/métodos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA