Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 15(4): e0229785, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32271783

RESUMO

Software development outsourcing is becoming more and more famous because of the advantages like cost abatement, process enhancement, and coping with the scarcity of needed resources. Studies confirm that unfortunately a large proportion of the software development outsourcing projects fails to realize anticipated benefits. Investigations into the failures of such projects divulge that in several cases software development outsourcing projects are failed because of the issues that are associated with requirements engineering process. The objective of this study is the identification and the ranking of the commonly occurring issues of the requirements engineering process in the case of software development outsourcing. For this purpose, contemporary literature has been assessed rigorously, issues faced by practitioners have been identified and three questionnaire surveys have been organized by involving experienced software development outsourcing practitioners. The Delphi technique, cut-off value method and 50% rule have also been employed. The study explores 150 issues (129 issues from literature and 21 from industry) of requirements engineering process for software development outsourcing, groups the 150 issues into 7 identified categories and then extricates 43 customarily or commonly arising issues from the 150 issues. Founded on 'frequency of occurrence' the 43 customarily arising issues have been ranked with respect to respective categories (category-wise ranking) and with respect to all the categories (overall ranking). Categories of the customarily arising issues have also been ranked. The issues' identification and ranking contribute to design proactive software project management plan for dealing with software development outsourcing failures and attaining conjectured benefits of the software development outsourcing.


Assuntos
Engenharia , Serviços Terceirizados , Software , Conhecimento , Participação dos Interessados , Inquéritos e Questionários
2.
Polymers (Basel) ; 11(10)2019 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-31635117

RESUMO

The photon induced radical-initiated polymerization in polymer gels can be used for high-resolution tissue equivalent dosimeters in quality control of radiation therapy. The dose (D) distribution in radiation therapy can be measured as a change of the physical measurement parameter T2 using T2-weighted magnetic resonance imaging. The detection by T2 is relying on the local change of the molecular mobility due to local polymerization initiated by radicals generated by the ionizing radiation. The dosimetric signals R2 = 1/T2 of many of the current polymer gels are dose-rate dependent, which reduces the reliability of the gel for clinical use. A novel gel dosimeter, based on methacrylic acid, gelatin and the newly added dithiothreitol (MAGADIT) as an oxygen-scavenger was analyzed for basic properties, such as sensitivity, reproducibility, accuracy and dose-rate dependence. Dithiothreitol features no toxic classification with a difference to THPC and offers a stronger negative redox-potential than ascorbic acid. Polymer gels with three different concentration levels of dithiothreitol were irradiated with a preclinical research X-ray unit and MR-scanned (T2) for quantitative dosimetry after calibration. The polymer gel with the lowest concentration of the oxygen scavenger was about factor 3 more sensitive to dose as compared to the gel with the highest concentration. The dose sensitivity (α = ∆R2/∆D) of MAGADIT gels was significantly dependent on the applied dose rate D ˙ (≈48% reduction between D ˙ = 0.6 Gy/min and D ˙ = 4 Gy/min). However, this undesirable dose-rate effect reduced between 4-8 Gy/min (≈23%) and almost disappeared in the high dose-rate range (8 ≤   D ˙ ≤   12 Gy/min) used in flattening-filter-free (FFF) irradiations. The dose response varied for different samples within one manufacturing batch within 3%-6% (reproducibility). The accuracy ranged between 3.5% and 7.9%. The impact of the dose rate on the spatial integrity is demonstrated in the example of a linear accelerator (LINAC) small sized 5 × 10 mm2 10 MV photon field. For MAGADIT the maximum shift in the flanks in this field is limited to about 0.8 mm at a FFF dose rate of 15 Gy/min. Dose rate sensitive polymer gels likely perform better at high dose rates; MAGADIT exhibits a slightly improved performance compared to the reference normoxic polymer gel methacrylic and ascorbic acid in gelatin initiated by copper (MAGIC) using ascorbic acid.

3.
Phys Med Biol ; 63(6): 06NT01, 2018 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-29528035

RESUMO

Recent developments in radiation therapy aimed at more precise dose delivery along with higher dose gradients (dose painting) and more efficient dose delivery with higher dose rates e.g. flattening filter free (FFF) irradiation. Magnetic-resonance-imaging based polymer gel dosimetry offers 3D information for precise dose delivery techniques. Many of the proposed polymer gels have been reported to exhibit a dose response, measured as relaxation rate ΔR2(D), which is dose rate dependent. A lack of or a reduced dose-rate sensitivity is very important for dosimetric accuracy, especially with regard to the increasing clinical use of FFF irradiation protocols with LINACs at high dose rates. Some commonly used polymer gels are based on Methacrylic-Acid-Gel-Initiated-by-Copper (MAGIC). Here, we report on the dose sensitivity (ΔR2/ΔD) of MAGIC-type gels with different oxygen scavenger concentration for their specific dependence on the applied dose rate in order to improve the dosimetric performance, especially for high dose rates. A preclinical x-ray machine ('Yxlon', E = 200 kV) was used for irradiation to cover a range of dose rates from low [Formula: see text] min = 0.6 Gy min-1 to high [Formula: see text] max = 18 Gy min-1. The dose response was evaluated using R2-imaging of the gel on a human high-field (7T) MR-scanner. The results indicate that all of the investigated dose rates had an impact on the dose response in polymer gel dosimeters, being strongest in the high dose region and less effective for low dose levels. The absolute dose rate dependence [Formula: see text] of the dose response in MAGIC-type gel is significantly reduced using higher concentrations of oxygen scavenger at the expense of reduced dose sensitivity. For quantitative dose evaluations the relative dose rate dependence of a polymer gel, normalized to its sensitivity is important. Based on this normalized sensitivity the dose rate sensitivity was reduced distinctly using an increased oxygen scavenger concentration with reference to standard MAGIC-type gel formulation at high dose rate levels. The proposed gel composition with high oxygen scavenger concentration exhibits a larger linear active dose response and might be used especially in FFF-radiation applications and preclinical dosimetry at high dose rates. We propose in general to use high dose rates for calibration and evaluation as the change in relative dose sensitivity is reduced at higher dose rates in all of the investigated gel types.


Assuntos
Ácido Ascórbico/química , Sulfato de Cobre/química , Sequestradores de Radicais Livres/química , Gelatina/química , Hidroquinonas/química , Imageamento por Ressonância Magnética/métodos , Metacrilatos/química , Oxigênio/química , Polímeros/química , Radiometria/métodos , Ácido Ascórbico/efeitos da radiação , Calibragem , Sulfato de Cobre/efeitos da radiação , Gelatina/efeitos da radiação , Humanos , Hidroquinonas/efeitos da radiação , Metacrilatos/efeitos da radiação , Polímeros/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...