Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 13(1): e12585, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33575147

RESUMO

Introduction Many surgical techniques have been described for the treatment of Neer type II lateral end clavicle fractures like open reduction and internal fixation with hook plate, tension band wiring, coracoclavicular screw fixation, and distal clavicle locking plate. However, most of these operative procedures are associated with high perioperative complications ranging from hardware prominence, hardware failure, screw and plate pull-out, and infection. As the lateral end clavicle fractures has both vertical and horizontal stress forces, any technique counteracting both the forces should result in a better clinical outcome. Therefore, this study was conducted to assess the functional and radiological outcome of type II lateral end clavicle fracture treated using pre-contoured locking plate along with coracoclavicular reconstruction with endobutton and fiberwire. Methods Thirty-two consecutive patients with Neer type II fractures of the lateral end of clavicle were treated surgically using pre-contoured locking plate and coracoclavicular reconstruction with endobutton and fiberwire between May 2014 and December 2016. Clinical outcome was assessed using the University of California Los Angeles (UCLA) shoulder score and Constant Murley score. The coracoclavicular distance was also recorded. These were compared to the unaffected side at one-year follow-up. Results The bony union was achieved in all cases. There were no major complications in any of the patients. All the patients were able to return to their preinjury level of activity. The UCLA score, the Constant Murley score, and coracoclavicular distance did not vary significantly at a one-year interval when compared to the normal shoulder. Conclusion Open reduction and internal fixation of Neer type II lateral end clavicle fractures using pre-contoured locking distal clavicle plate along with coracoclavicular reconstruction with endobutton and No. 2 fiberwire provide an excellent functional and radiological outcome.

2.
J Orthop ; 10(4): 162-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24396235

RESUMO

BACKGROUND: Vast majority of spine fractures in thoracolumbar region are unstable and often associated with neurological deficit. With the advancement of technology, these fractures are now more often managed operatively. The present study aimed at evaluating the role of open reduction & internal fixation using pedicle screws and short segment fixation in patients with Thoracic and Lumbar spine fractures. DESIGN: In this prospective study, 25 patients in age group of 15-65 years (mean age 28.25 years) with thoracolumbar fractures with associated neurological deficit or compression fractures with loss of more than 50% vertebral height or angulations more than 20° with or without neurological deficit were included. The results were evaluated based on restoration and maintenance of vertebral body height, spinal lordosis/kyphosis and evaluation of the neurological recovery which was done at regular intervals using Frankel's grading. RESULTS: The mean follow-up period was 20.3 months. The average preoperative kyphotic angle as measured by Cobbs method was 20° which improved to 7.8° following instrumentation. The average preoperative vertebral height was 58.65% which improved to 78.55% postoperatively. Preoperatively, only 20% of patients had useful paraplegia (Frankel grade D and E) while 80% had useless paraplegia (Frankel's grade C and below). Following surgery, 60% patients had useful paraplegia while 40% had useless paraplegia. CONCLUSION: Short segment trans-pedicle posterior fixation is helpful for not only stabilization of the fractures and restoration of anatomy, but also maintaining the same over a period with good functional outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...