1.
Phys Med Biol ; 50(11): 2543-57, 2005 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-15901953

RESUMO

We present PAM, the Photoacoustic Mammoscope developed at the University of Twente, intended for initial retrospective clinical studies on subjects with breast tumours. A parallel plate geometry has been adopted and the breast will be gently compressed between a glass plate and a flat ultrasound detector matrix. Pulsed light (5 ns) from an Nd:YAG laser will impinge the breast through the glass plate in regions of interest; an appropriate number of the 590 elements of the detector matrix will be activated in succession to record photoacoustic signals. Three-dimensional image reconstruction employs a delay-and-sum beamforming algorithm. We discuss various instrumental aspects and the proposed imaging protocol. Performance studies of the ultrasound detector are presented in terms of sensitivity, frequency response and resolution. Details of the patient-instrument interface are provided. Finally some imaging results on well-characterized breast tissue phantoms with embedded tumour simulating inserts are shown.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia Mamária/métodos , Acústica , Feminino , Análise de Fourier , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Espectroscopia de Luz Próxima ao Infravermelho , Ultrassonografia Mamária/instrumentação
2.
J Biomed Opt ; 9(6): 1172-81, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15568937

RESUMO

We present a laboratory version of a photoacoustic mammoscope, based on a parallel plate geometry. The instrument is built around a flat high-density ultrasound detector matrix. The light source is a Q-switched Nd:YAG laser with a pulse duration of 5 ns. To test the instrument, a novel photoacoustic phantom is developed using poly(vinyl alcohol) gel, prepared by a simple procedure that imparts optical scattering suggestive of breast tissue to it without the requirement for extraneous scattering particles. Tumor simulating poly(vinyl alcohol) gel spheres appropriately dyed at the time of preparation are characterized for optical absorption coefficients. These are then embedded in the phantom to serve as tumors with absorption contrasts ranging from 2 to 7, with respect to the background. Photoacoustic studies in transmission mode are performed, by acquiring the laser-induced ultrasound signals from regions of interest in the phantom. Image reconstruction is based on a delay-and-sum beamforming algorithm. The results of these studies provide an insight into the capabilities of the prototype. Various recommendations that will guide the evolving of our laboratory prototype into a clinical version are also discussed.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Espectrofotometria Infravermelho/instrumentação , Espectrofotometria Infravermelho/métodos , Ultrassonografia Mamária/instrumentação , Ultrassonografia Mamária/métodos , Acústica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Humanos , Óptica e Fotônica/instrumentação , Imagens de Fantasmas , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Phys Med Biol ; 48(3): 357-70, 2003 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-12608612

RESUMO

Materials for solid photoacoustic breast phantoms, based on poly(vinyl alcohol) hydrogels, are presented. Phantoms intended for use in photoacoustics must possess both optical and acoustic properties of tissue. To realize the optical properties of tissue, one approach was to optimize the number of freezing and thawing cycles of aqueous poly(vinyl alcohol) solutions, a procedure which increases the turbidity of the gel while rigidifying it. The second approach concentrated on forming a clear matrix of the rigid poly(vinyl alcohol) gel without any scattering, so that appropriate amounts of optical scatterers could be added at the time of formation, to tune the optical properties as per requirement. The relevant optical and acoustic properties of such samples were measured to be close to the average properties of human breast tissue. Tumour simulating gel samples of suitable absorption coefficient were created by adding appropriate quantities of dye at the time of formation; the samples were then cut into spheres. A breast phantom embedded with such 'tumours' was developed for studying the applicability of photoacoustics in mammography.


Assuntos
Géis , Imagens de Fantasmas , Álcool de Polivinil , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Ultrassonografia Mamária/instrumentação , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Desenho de Equipamento , Humanos , Mamografia/instrumentação , Mamografia/métodos , Teste de Materiais/métodos , Espalhamento de Radiação , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Técnica de Subtração , Ultrassonografia Mamária/métodos