Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 13293, 2024 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858424

RESUMO

We introduce magnetophoresis-based microfluidics for sorting biological targets using positive Magnetophoresis (pM) for magnetically labeled particles and negative Magnetophoresis (nM) for label-free particles. A single, externally magnetized ferromagnetic wire induces repulsive forces and is positioned across the focused sample flow near the main channel's closed end. We analyze magnetic attributes and separation performance under two transverse dual-mode magnetic configurations, examining magnetic fields, hydrodynamics, and forces on microparticles of varying sizes and properties. In pM, the dual-magnet arrangement (DMA) for sorting three distinct particles shows higher magnetic gradient generation and throughput than the single-magnet arrangement (SMA). In nM, the numerical results for SMA sorting of red blood cells (RBCs), white blood cells (WBCs), and prostate cancer cells (PC3-9) demonstrate superior magnetic properties and throughput compared to DMA. Magnetized wire linear movement is a key design parameter, allowing device customization. An automated device for handling more targets can be created by manipulating magnetophoretic repulsion forces. The transverse wire and magnet arrangement accommodate increased channel depth without sacrificing efficiency, yielding higher throughput than other devices. Experimental validation using soft lithography and 3D printing confirms successful sorting and separation, aligning well with numerical results. This demonstrates the successful sorting and separating of injected particles within a hydrodynamically focused sample in all systems. Both numerical and experimental findings indicate a separation accuracy of 100% across various Reynolds numbers. The primary channel dimensions measure 100 µm in height and 200 µm in width. N52 permanent magnets were employed in both numerical simulations and experiments. For numerical simulations, a remanent flux density of 1.48 T was utilized. In the experimental setup, magnets measuring 0.5 × 0.5 × 0.125 inches and 0.5 × 0.5 × 1 inch were employed. The experimental data confirm the device's capability to achieve 100% separation accuracy at a Reynolds number of 3. However, this study did not explore the potential impact of increased flow rates on separation accuracy.


Assuntos
Técnicas Analíticas Microfluídicas , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Separação Celular/métodos , Separação Celular/instrumentação , Eritrócitos , Microfluídica/métodos , Microfluídica/instrumentação , Leucócitos , Hidrodinâmica , Linhagem Celular Tumoral
2.
Anal Bioanal Chem ; 415(7): 1339-1346, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36633621

RESUMO

This work demonstrates the fabrication of electrically tunable films of graphene oxide (GO). GO thin films were deposited and micropatterned on a cyclic olefin copolymer (COC) substrate using a plasma-enhanced liftoff technique. This article discusses thermal, chemical, and photoreduction methods for controlling the electrical conductivity of the patterned film. The patterned graphene oxide films were used to manipulate cells after embedding them in a microfluidic channel. Cells were manipulated under dielectrophoresis (DEP) using patterned reduced graphene oxide (rGO) films with varying electrical conductivities. The non-uniform electric field required for DEP was created either by arranging and shaping a set of electrodes (eDEP) or by simply implementing low conductivity rGO as an insulator between two metal electrodes (iDEP).

3.
Micromachines (Basel) ; 11(7)2020 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-32629991

RESUMO

This article details the mathematical model of a microfluidic device aimed at separating any binary heterogeneous sample of microparticles into two homogeneous samples based on size with sub-micron resolution. The device consists of two sections, where the upstream section is dedicated to focusing of microparticles, while the downstream section is dedicated to separation of the focused stream of microparticles into two samples based on size. Each section has multiple planar electrodes of finite size protruding into the microchannel from the top and bottom of each sidewall; each top electrode aligns with a bottom electrode and they form a pair leading to multiple pairs of electrodes on each side. The focusing section subjects all microparticles to repulsive dielectrophoretic force, from each set of the electrodes, to focus them next to one of the sidewalls. This separation section pushes the big microparticles toward the interior, away from the wall, of the microchannel using repulsive dielectrophoretic force, while the small microparticles move unaffected to achieve the desired degree of separation. The operating frequency of the set of electrodes in the separation section is maintained equal to the cross-over frequency of the small microparticles. The working of the device is demonstrated by separating a heterogeneous mixture consisting of polystyrene microparticles of different size (radii of 2 and 2.25 µm) into two homogeneous samples. The mathematical model is used for parametric study, and the performance is quantified in terms of separation efficiency and separation purity; the parameters considered include applied electric voltages, electrode dimensions, outlet widths, number of electrodes, and volumetric flowrate. The separation efficiencies and separation purities for both microparticles are 100% for low volumetric flow rates, a large number of electrode pairs, large electrode dimensions, and high differences between voltages in both sections.

4.
Chem Rec ; 18(11): 1596-1612, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29888856

RESUMO

Magnetophoresis, the manipulation of trajectory of micro-scale entities using magnetic forces, as employed in microfluidic devices is reviewed at length in this article. Magnetophoresis has recently garnered significant interest due to its simplicity, in terms of implementation, as well as cost-effectiveness while being efficient and biocompatible. Theory associated with magnetophoresis is illustrated in this review along with different sources for creating magnetic field gradient commonly employed in microfluidic devices. Additionally, this article reviews the state-of-the-art of magnetophoresis based microfluidic devices, where positive- and negative-magnetophoresis are utilized for manipulation of micro-scale entities (cells and microparticles), employed for operations such as trapping, focusing, separation, and switching of microparticles and cells. The article concludes with a brief outlook of the field of magnetophoresis.

5.
Talanta ; 164: 608-611, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28107980

RESUMO

This short communication presents the proof-of-concept of a novel dielectrophoretic lab-on-chip for identifying/separating circulating tumor cells for purposes of liquid biopsy. The device consists of a polydimethylsiloxane layer, containing a microchannel, bonded on a glass substrate that holds two sets of planar interdigitated transducer electrodes. The lab-on-chip is operated at a frequency that enables dielectrophoretic force to sort cells, based on type, along the lateral direction. The operating frequency ensures attraction force toward the electrodes on cancer cells and repulsion force toward the center of the microchannel on other cells. Initial tests for demonstrating proof-of-concept have successfully identified/separated green fluorescent protein-labelled MDA-MB-231 breast cancer cells from a mixture of the same and regular blood cells suspended in low conductivity sucrose/dextrose medium.


Assuntos
Eletroforese/instrumentação , Dispositivos Lab-On-A-Chip , Biópsia Líquida/instrumentação , Linhagem Celular Tumoral , Impedância Elétrica , Humanos
6.
J Contam Hydrol ; 157: 73-86, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24365395

RESUMO

Single-rate transport models are commonly used for interpreting sorption-related mass transfer in porous media, often with the intention of approximating the kinetics of the sorption process. Among the most commonly used single-rate models are the two-site first-order (TSFO) and the two-site radial diffusion (TSRD) models. We fitted the parameters of the TSFO and TSRD models to simulated breakthrough data of hypothetical column experiments in which sorption rates were described by a γ-distributed sorption sites (GS) model. Our objective was to determine the conditions under which the assumption of a single-rate sorption parameter will be applicable to systems with heterogeneous sorption rates. We were further interested in knowing in what manner the fitted single-rate nonequilibrium model parameters depend upon the conditions under which the data were obtained. The considered hypothetical cases covered a range of experimental conditions and involved compounds with different sorption characteristics. The study revealed that the goodness of fit of the single rate models in simulating the transport of solutes exhibiting heterogeneous sorption rates is affected by solute residence time and pulse injection duration. Compared to the TSFO model, the TSRD model generally results in better prediction of solute transport affected by heterogeneous sorption kinetics. In addition, for such systems, the nonequilibrium parameters fitted using the TSFO model and their counterparts in the TSRD model are highly correlated. Moreover, an increase in the fitted mass transfer timescale of each of the single-rate models is coupled with an increase in the associated fraction of instantaneous sorption sites. A strong correlation was found between the time of the experiment and the product of the fitted characteristic time for mass transfer, pulse duration, and solute residence time. The correlation explains many of the variations in the mass transfer timescale encountered when single-rate sorption approaches were utilized to model solute transport in previous miscible displacement studies.


Assuntos
Modelos Teóricos , Adsorção , Água Subterrânea/química , Cinética , Solo/química , Movimentos da Água , Poluentes Químicos da Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...