Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Can J Cardiol ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38642847

RESUMO

Cardiac implantable electronic devices (CIEDs) are often important for regulating cardiac rate and rhythm. Pacemakers and defibrillators are among the top 10 most implanted medical devices, with > 1.5 million devices implanted annually. Although millions of patients have benefited with improved quality of life and survival, CIED systems are becoming increasingly complex and do not always perform according to expectations. Advisory notices communicate important information about the safety and performance of a medical device to health care providers and patients. Medical device recalls are common, with > 35 unique device recalls in the past 5 years. From an ethical standpoint, CIED recalls highlight a range of considerations including the consent process, duty to report, how best to promote autonomous decision-making, trust in the health care system, as well as disproportionate effects of these considerations on equity-deserving groups. The purpose of the current article is to review and advise regarding the process around medical device advisory and recall, with a specific focus on clinicians caring for patients affected by these devices. We have sought the input of a lawyer, a patient advocacy group, and an ethicist to guide the clinical management of, and communications regarding, device recalls and advisories. Diligent surveillance and a clear, transparent patient consent process regarding these small but potentially serious device anomalies is paramount in ensuring patients believe they are safe and informed. Meaningful patient engagement helps to ensure optimal communication and disclosure mechanisms before implantation and throughout follow-up, accessibility of information in the initial implant and recall action process, and trust in health care systems and providers.

2.
JACC Case Rep ; 29(7): 102283, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38645292

RESUMO

Patients with Ebstein anomaly are known to have a higher incidence of interatrial communications and shunting of blood and its components through, mainly due to either streaming of tricuspid regurgitation or due to elevated right atrial pressure. Here we describe a case where permanent pacemaker lead kept a patent foramen ovale open leading to right-to-left shunting of blood and exertional hypoxemia. This is the first such case report in the published literature.

4.
J Arrhythm ; 38(4): 615-621, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35936035

RESUMO

Background: Cardiac Implantable Electronic Devices (CIED) include pulse generators and leads. In some implanting centers, it is a common practice to combine devices with leads from different companies. Case series have reported episodic high-impedance changes in Boston Scientific CIEDs with competitor leads. We investigated the incidence of high-impedance abnormalities in matched versus mismatched Boston Scientific Accolade pacemakers. Methods: A retrospective chart review identified all consecutive Boston Scientific Accolade pacemakers implanted between January 2017 and June 2019 at a Canadian tertiary care center. The primary outcome was the occurrence of transient, high-impedance changes which resulted in a switch to unipolar pacing/sensing in the absence of any other identifiable lead issue. Fisher exact tests (two-tailed, α = .05) were used to compare the incidence of outcomes in matched versus mismatched systems. Results: 514 Boston Scientific Accolade pacemakers were associated with 882 individual leads. The primary outcome occurred with 21 leads (20 Medtronic and 1 Abbott), associated with occasional pacing inhibition, presyncope, and/or early surgical revision. Mismatched lead-device pairs were significantly associated with CIED malfunction compared to matched lead-device pairs (3.3% vs. 0%, p = .0019). The median time from implant to unipolar safety switch was 12.4 months. The median follow-up time was 21.6 months. Conclusion: Use of mismatched leads with a Boston Scientific Accolade device was associated with an increased risk of undesirable changes in sensing polarity with occasional inappropriate pacing inhibition. Awareness of this interaction can allow for the institution of appropriate programming remedies and may increase scrutiny of the use of mismatched CIED systems.

6.
CJC Open ; 2(6): 699-701, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33305231

RESUMO

A high-risk left-sided posterolateral manifest accessory pathway (AP) was identified in a 49-year-old man. Two prior ablations had failed. A repeat procedure using 3D electroanatomic mapping demonstrated an extremely oblique AP. The earliest atrial activation site was not amenable to endocardial ablation. The earliest ventricular activation site was identified, demonstrating an AP with an extremely slanted course. Radiofrequency ablation here resulted in sustained bidirectional AP block. In challenging AP ablation cases, recognition of the potential for an oblique AP and the use of electroanatomic mapping may be beneficial.


Une voie accessoire (VA) apparente postéro-latérale gauche à haut risque a été identifiée chez un homme de 49 ans. Deux ablations antérieures avaient échoué. Une procédure répétée utilisant la cartographie électroanatomique 3D a révélé une VA extrêmement oblique. Le site ayant l'activation auriculaire la plus précoce ne se prêtait pas à une ablation endocardique. Le site ayant l'activation ventriculaire la plus précoce a été identifié, montrant une VA avec une trajectoire extrêmement inclinée. L'ablation par radiofréquence a ici entraîné un bloc bidirectionnel soutenu de la VA. Dans les cas difficiles d'ablation de VA, la reconnaissance du potentiel d'une VA oblique et l'utilisation de la cartographie électroanatomique peuvent être bénéfiques.

7.
JACC Clin Electrophysiol ; 6(8): 935-944, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32819528

RESUMO

OBJECTIVES: This study evaluated the impact of contact force-guided radiofrequency ablation versus cryoballoon ablation on quality of life and health care utilization. BACKGROUND: Traditional outcome parameters, such as arrhythmia-free survival, are insufficient to evaluate the clinical impact of atrial fibrillation (AF), as it fails to the capture patient- and health system-level differences in treatment approaches. METHODS: The CIRCA-DOSE (Cryoballoon Vs. Contact-Force Atrial Fibrillation Ablation) study randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency or cryoballoon ablation. Health-related quality-of-life (HRQOL) was assessed at baseline, and at 6 and 12 months post-ablation using a disease-specific and generic HRQOL instruments. Health care utilization (hospitalization, emergency department visits, and cardioversion) and antiarrhythmic drug use for the 12 months preceding ablation was compared with the 12 months following ablation. RESULTS: Disease-specific and generic HRQOL was moderately to severely impaired at baseline and improved significantly at 6 and 12 months of follow-up (median improvement in AFEQT [Atrial Fibrillation Effect on QualiTy of Life] score 32.4 [interquartile range: 17.7 to 48.9]). When compared with the 12 months pre-ablation, the proportion and absolute number of cardioversions decreased significantly (41.1% vs. 10.1% of patients, 137 vs. 35 events; p < 0.0001). Similar significant reductions in emergency department visits (66.7% vs. 25.1% of patients, 224 vs. 87 events; p < 0.0001), and hospitalizations (25.5% vs. 14.5% of patients, 86 vs. 50 events; p < 0.001) were observed. There were no significant differences between randomized groups. CONCLUSIONS: In this multicenter randomized trial, catheter ablation with advanced-generation technologies resulted in a significant improvement in HRQOL and a significant reduction in health care utilization in the year following AF ablation. (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation [CIRCA-DOSE]; NCT01913522).


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Humanos , Aceitação pelo Paciente de Cuidados de Saúde , Qualidade de Vida , Resultado do Tratamento
8.
Can J Cardiol ; 36(6): 822-836, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32536373

RESUMO

This Canadian Cardiovascular Society position statement is focused on the management of sustained ventricular tachycardia (VT) and ventricular fibrillation (VF) that occurs in patients with structural heart disease (SHD), including previous myocardial infarction, dilated cardiomyopathy, and other forms of nonischemic cardiomyopathy. This patient population is rapidly increasing because of advances in care and improved overall survival of patients with all forms of SHD. In this position statement, the acute and long-term management of VT/VF are outlined, and the many unique aspects of care in this population are emphasized. The initial evaluation, acute therapy, indications for chronic suppressive therapy, choices of chronic suppressive therapy, implantable cardioverter-defibrillator programming, alternative therapies, and psychosocial care are reviewed and recommendations for optimal care are provided. The target audience for this statement includes all health professionals involved in the continuum of care of patients with SHD and VT/VF.


Assuntos
Cardiomiopatias/complicações , Morte Súbita Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Administração dos Cuidados ao Paciente/métodos , Taquicardia Ventricular , Fibrilação Ventricular , Canadá , Cardiomiopatias/classificação , Cardiomiopatias/fisiopatologia , Continuidade da Assistência ao Paciente/organização & administração , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Técnicas de Diagnóstico Cardiovascular/instrumentação , Humanos , Comunicação Interdisciplinar , Assistência de Longa Duração/métodos , Reabilitação Psiquiátrica/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia
9.
J Electrocardiol ; 60: 159-164, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32371199

RESUMO

BACKGROUND: Contemporary guidelines recommend that atrial fibrillation (AF) be classified into paroxysmal and persistent AF based on clinical assessment, with these categorizations forming the basis of therapeutic recommendations. While pragmatic, clinical assessment may introduce misclassification errors, which may impact treatment decisions. We sought to determine the relationship between AF classification, baseline AF burden, and post-ablation arrhythmia outcomes. DESIGN: The current study is a sub-analysis of a prospective, parallel-group, multicenter, single-blinded randomized clinical trial. All 346 patients enrolled in CIRCA-DOSE received an implantable cardiac monitor a median of 72 days prior to ablation. AF was classified as low burden paroxysmal, high burden paroxysmal, or persistent based on clinical assessment prior to device implantation. Prior to ablation patients were re-classified using the same definitions based on device monitoring data. Correlation between classifications, AF burden, and post-ablation arrhythmia outcomes were assessed. RESULTS: There was poor agreement between clinical and device-based AF classification (Cohen's kappa: 0.192). AF classification derived from pre-ablation continuous monitoring reflected baseline and post-ablation AF burden with greater accuracy and with less overlap between the AF classes (P < 0.01 for all categorical comparisons). Patients objectively classified as "Low Burden" paroxysmal by continuous monitoring data had significantly greater freedom from recurrent AF/AT/AFL compared to those classified as "High Burden" paroxysmal (hazard ratio [HR] 0.57 for AF/AT/AFL recurrence) or persistent AF (HR 0.19 for AF/AT/AFL recurrence). CONCLUSIONS: Classification of AF pattern based on pre-ablation continuous cardiac rhythm monitoring better predicted AF burden and freedom from recurrent AF post ablation. Despite the use of standardized definitions, classification of AF based on clinical assessment did not predict baseline AF burden, post ablation AF burden, or freedom from recurrent AF post ablation. TRIAL REGISTRATION: ClinicalTrials.govNCT01913522.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrocardiografia , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
10.
Indian Pacing Electrophysiol J ; 20(3): 129-131, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32145398

RESUMO

An 18 year old male with an incompletely healed clavicle fracture presented with unexplained syncope. Subsequent investigations were consistent with a diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC). A subcutaneous implantable cardioverter-defibrillator (S-ICD) was successfully implanted and defibrillation threshold (DFT) testing performed as per standard protocol. Shortly following the procedure, the patient complained of pain and swelling over the left clavicle. A radiograph revealed aggravation and displacement of the underlying clavicle fracture. Surgical reduction and internal fixation was performed one week later.

12.
Circulation ; 140(22): 1779-1788, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31630538

RESUMO

BACKGROUND: Advanced generation ablation technologies have been developed to achieve more effective pulmonary vein isolation (PVI) and minimize arrhythmia recurrence after atrial fibrillation (AF) ablation. METHODS: We randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency ablation (CF-RF; n=115), 4-minute cryoballoon ablation (Cryo-4; n=115), or 2-minute cryoballoon ablation (Cryo-2; n=116). Follow-up was 12 months. The primary outcome was time to first documented recurrence of symptomatic or asymptomatic atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia) between days 91 and 365 after ablation or a repeat ablation procedure at any time. Secondary end points included freedom from symptomatic arrhythmia and AF burden. All patients received an implantable loop recorder. RESULTS: One-year freedom from atrial tachyarrhythmia defined by continuous rhythm monitoring was 53.9%, 52.2%, and 51.7% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.87). One-year freedom from symptomatic atrial tachyarrhythmia defined by continuous rhythm monitoring was 79.1%, 78.2%, and 73.3% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.26). Compared with the monitoring period before ablation, AF burden was reduced by a median of 99.3% (interquartile range, 67.8%-100.0%) with CF-RF, 99.9% (interquartile range, 65.3%-100.0%) with Cryo-4, and 98.4% (interquartile range, 56.2%-100.0%) with Cryo-2 (P=0.36). Serious adverse events occurred in 3 patients (2.6%) in the CF-RF group, 6 patients (5.3%) in the Cryo-4 group, and 7 patients (6.0%) in the Cryo-2 group, with no significant difference between groups (P=0.24). The CF-RF group had a significantly longer procedure duration but significantly shorter fluoroscopy exposure (P<0.001 vs cryoballoon groups). CONCLUSIONS: In this multicenter, randomized, single-blinded trial, CF-RF and 2 different regimens of cryoballoon ablation resulted in no difference in 1-year efficacy, which was 53% by time to first recurrence but >98% burden reduction as assessed by continuous cardiac rhythm monitoring. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01913522.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Feminino , Fluoroscopia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
13.
Indian J Crit Care Med ; 23(2): 102-103, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31086456

RESUMO

We report an unusual complication of permanent pacemaker (PPM) implantation in a patient with a temporary transvenous pacemaker (TVP) in situ, in which the TVP lead formed a knot around the newly-placed right ventricular (RV) lead, complicating TVP removal. The case underscores the fact that suboptimal TVP lead placement, such as looping in the RV, can result in complications during implantation of a permanent pacemaker. HOW TO CITE THIS ARTICLE: Wiens EJ, Seifer CM et al. Inadvertent Removal of a Right Ventricular Pacemaker Lead by a Knotted Transvenous Pacing Wire. Indian J of Crit Care Med 2019;23(2):102-103.

14.
J Arrhythm ; 35(1): 61-69, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30805045

RESUMO

BACKGROUND: Evidence regarding the incremental benefit of cardiac resynchronization therapy (CRT) with a defibrillator (CRT-D) versus without (CRT-P) in elderly patients with heart failure is limited. We compared mortality and cardiac hospitalisation between CRT-D and CRT-P in the elderly. METHODS: A retrospective chart review identified all consecutive patients with age ≥75 with CRT implantation over the last 10 years at a Canadian tertiary care cardiac centre. Kaplan-Meier survival analyses and cumulative incidence curves were used to compare mortality and time to first cardiac hospitalisation, respectively, with CRT-D versus CRT-P over a 3 year period. Analyses were also repeated with propensity score matching based on age, sex, primary versus secondary prevention, date of implant, and Charlson Comorbidity Index. RESULTS: One hundred and seventy CRT patients were identified. A total of 128 received CRT-D while 42 received CRT-P. Median age was 79 (IQR 77-81), and the majority were male (83%). CRT-P patients had a higher burden of comorbidities (Charlson score 7, IQR 6-8) than CRT-D patients (Charlson score 5, IQR 5-7; P < 0.001). There was no significant difference in survival between the two groups in an unmatched comparison (P = 0.69) and with a propensity score-matched cohort (P = 0.91). Secondary prevention CRT-D patients had a higher risk of hospitalisation compared to primary prevention CRT-D patients; however, there was no significant difference in hospitalisation between the CRT-D and CRT-P groups. CONCLUSION: This study suggests there is no significant difference in mortality or cardiac hospitalisation between CRT-D and CRT-P in elderly patients with heart failure.

15.
CJC Open ; 1(1): 35-38, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32159080

RESUMO

Takotsubo cardiomyopathy (TTC) may clinically mimic an acute coronary syndrome and is most often associated with an acute stressor. In this case report, we describe an atypical case of TTC triggered by multiple subacute stressors rather than 1 acute stressor. We also report TTC and transient global amnesia occurring concurrently. This case highlights that TTC can present without a typical stressor and should nonetheless by considered in the appropriate clinical context. Concomitant presentation with transient global amnesia is uncommon, but may result from the 2 conditions potentially sharing an underlying etiology.


La cardiomyopathie de Takotsubo (CTT) peut ressembler sur le plan clinique à un syndrome coronarien aigu et est plus souvent associée à un facteur de stress aigu. Dans ce rapport de cas, nous décrivons un cas atypique de CTT provoquée par de nombreux facteurs de stress subaigu plutôt que 1 facteur de stress aigu. Nous faisons également état de la survenue simultanée de la CTT et de l'amnésie globale transitoire. Ce cas illustre que la CTT peut survenir sans facteur de stress typique et qu'elle devrait néanmoins être considérée dans le contexte clinique approprié. La survenue concomitante de la CTT et de l'amnésie globale transitoire n'est pas fréquente, mais peut résulter de 2 affections ayant possiblement en commun une étiologie sous-jacente.

16.
Ther Adv Cardiovasc Dis ; 12(4): 113-122, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29528778

RESUMO

OBJECTIVES: The objectives of this study were to evaluate the effectiveness of a physician notification system for atrial fibrillation (AF) detected on cardiac devices, and to assess predictors of anticoagulation in patients with device-detected AF. METHODS: In 2013, a physician notification system for AF detected on a patient's CIED [including pacemakers, implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy (CRT) devices] was implemented, with a recommendation to consider oral anticoagulation in high-risk patients. We prospectively investigated the effectiveness of this system, and evaluated both patient and physician predictors of anticoagulation, as well as factors influencing physician decision making in prescribing anticoagulation. Both uni- and multivariable analysis as well as descriptive statistics were used in the analysis. RESULTS: We identified 177 patients with device-detected AF, 126 with a CHADS2 ⩾2. Only 41% were prescribed anticoagulation at any point within 12 months. On multivariable analysis, stroke risk as predicted by CHADS2 was not a predictor of anticoagulation. ASA use predicted a lower rate of anticoagulation (OR 0.39, 95% CI 0.16-0.97, p = 0.04); physicians in practice for <20 years were more likely to prescribe anticoagulation (OR 3.39, 95% CI 1.28-8.93, p = 0.01); and physicians who believed both cardiologist and family doctor should be involved in managing anticoagulation were more likely to prescribe anticoagulation (OR 3.28, 95% CI 1.02-10.5, p = 0.05). CONCLUSIONS: Patients on aspirin were less likely to be anticoagulated. Physicians in practice for <20 years and who believed that both the general practitioner and cardiologist should be involved in managing anticoagulants were more likely to prescribe anticoagulation.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/tratamento farmacológico , Tomada de Decisão Clínica , Sistemas de Apoio a Decisões Clínicas , Desfibriladores Implantáveis , Marca-Passo Artificial , Sistemas de Alerta , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Dispositivos de Terapia de Ressincronização Cardíaca , Técnicas de Apoio para a Decisão , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Modelos Logísticos , Masculino , Sistemas de Registro de Ordens Médicas , Análise Multivariada , Razão de Chances , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Processamento de Sinais Assistido por Computador , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
17.
Ther Adv Cardiovasc Dis ; : 1753944718749739, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29320931

RESUMO

OBJECTIVES: The objectives of this study were to evaluate the effectiveness of a physician notification system for atrial fibrillation (AF) detected on cardiac devices, and to assess predictors of anticoagulation in patients with device-detected AF. METHODS: In 2013, a physician notification system for AF detected on a patient's CIED [including pacemakers, implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy (CRT) devices] was implemented, with a recommendation to consider oral anticoagulation in high-risk patients. We prospectively investigated the effectiveness of this system, and evaluated both patient and physician predictors of anticoagulation, as well as factors influencing physician decision making in prescribing anticoagulation. Both uni- and multivariable analysis as well as descriptive statistics were used in the analysis. RESULTS: We identified 177 patients with device-detected AF, 126 with a CHADS2 ⩾2. Only 41% were prescribed anticoagulation at any point within 12 months. On multivariable analysis, stroke risk as predicted by CHADS2 was not a predictor of anticoagulation. ASA use predicted a lower rate of anticoagulation (OR 0.39, 95% CI 0.16-0.97, p = 0.04); physicians in practice for <20 years were more likely to prescribe anticoagulation (OR 3.39, 95% CI 1.28-8.93, p = 0.01); and physicians who believed both cardiologist and family doctor should be involved in managing anticoagulation were more likely to prescribe anticoagulation (OR 3.28, 95% CI 1.02-10.5, p = 0.05). CONCLUSIONS: Patients on aspirin were less likely to be anticoagulated. Physicians in practice for <20 years and who believed that both the general practitioner and cardiologist should be involved in managing anticoagulants were more likely to prescribe anticoagulation.

19.
J Am Soc Echocardiogr ; 26(6): 600-5, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23562085

RESUMO

BACKGROUND: Bicuspid aortic valves (BAVs) are associated with aortopathy. Recent studies suggest that aortic dilatation is more likely to be seen with left-right coronary cusp fusion (type I) compared with right-noncoronary cusp fusion (type II). The aim of this study was to investigate the association between BAV morphology and patterns of aortopathy. METHODS: Aortic dimensions and BAV morphology were obtained retrospectively from archived cine loops of 581 consecutive patients with BAVs and 277 matched normal controls from the Vancouver General Hospital echocardiography database. Patient demographics and other echocardiographic parameters were extracted from the database. RESULTS: The study population was composed of 71% type I BAVs (415 patients) and 26% type II BAVs (149 patients). Aortic dilatation was present in 30% of the population. Type I BAV was associated with increased dimensions indexed to body surface area at the sinus of Valsalva compared with type II BAV. No difference in proximal ascending aortic dimension was seen between different BAV morphologies. The pattern of dilatation with type I BAV was more likely to be at the level of the annulus or sinus of Valsalva compared with type II BAV (62% vs 33%, P= .002). Type I BAV was an independent predictor of proximal aortic dilatation (odds ratio, 3.42; 95% confidence interval, 1.07-10.9). CONCLUSIONS: Type I BAV is associated with a greater likelihood of dilatation at the annulus and sinus of Valsalva. There is relative sparing of this region of the aorta in patients with type II BAVs. Individuals with different BAV morphologies may require different strategies of aortopathy surveillance.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Ecocardiografia/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Análise de Variância , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Dilatação Patológica , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco
20.
Heart ; 99(17): 1250-5, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23468515

RESUMO

BACKGROUND: There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes. OBJECTIVE: To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort. DESIGN, SETTING, PATIENTS: A cohort study which included all subjects who underwent ICD implantation between 1998 and 2008 and were followed up at our institution. MAIN OUTCOME MEASURES: Multivariable Cox regression analyses were conducted to investigate the effect of inappropriate shocks on the risk of death and heart transplantation. Appropriate and inappropriate ICD therapies were modelled as time-dependent covariates. RESULTS: A total of 1698 patients were included. During a median follow-up of 30 months, there were 246 (14.5%) deaths and 42 (2.5%) heart transplants. The incidence of inappropriate shocks was 10% at 1 year and 14% at 2 years. In the adjusted model, inappropriate shocks were not associated with death or transplantation (HR=0.97, 95% CI 0.70 to 1.36, p value=0.873). In contrast, appropriate shocks were associated with adverse outcomes (HR=3.11, 95% CI 2.41 to 4.02, p value<0.001). The lack of association between inappropriate shocks and outcomes persisted for those with severely impaired left ventricular function (ejection fraction <30%) and for those receiving multiple inappropriate treatments. CONCLUSIONS: In this study, we observed no association between inappropriate ICD shocks and increased mortality or heart transplantation, even among those with severely impaired cardiac function. These findings question whether inappropriate ICD shocks lead to adverse outcomes.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Transplante de Coração/estatística & dados numéricos , Idoso , Arritmias Cardíacas/mortalidade , Colúmbia Britânica , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Fatores de Risco , Volume Sistólico/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...