Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 31(Pt 3): 438-446, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38652579

RESUMO

Knife-edge imaging is a successful method for determining the wavefront distortion of focusing optics such as Kirkpatrick-Baez mirrors or compound refractive lenses. In this study, the wavefront error of an imperfect elliptical mirror is predicted by developing a knife-edge program using the SHADOW/OASYS platform. It is shown that the focusing optics can be aligned perfectly by minimizing the parabolic and cubic coefficients of the wavefront error. The residual wavefront error provides precise information about the figure/height errors of the focusing optics suggesting it as an accurate method for in situ optical metrology. A Python program is developed to design a customized wavefront refractive corrector to minimize the residual wavefront error. Uniform beam at and out of focus and higher peak intensity are achieved by the wavefront correction in comparison with ideal focusing. The developed code provides a quick way for wavefront error analysis and corrector design for non-ideal optics especially for the new-generation diffraction-limited sources, and saves considerable experimental time and effort.

2.
J Synchrotron Radiat ; 31(Pt 3): 478-484, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38592970

RESUMO

Maximizing the performance of crystal monochromators is a key aspect in the design of beamline optics for diffraction-limited synchrotron sources. Temperature and deformation of cryo-cooled crystals, illuminated by high-power beams of X-rays, can be estimated with a purely analytical model. The analysis is based on the thermal properties of cryo-cooled silicon crystals and the cooling geometry. Deformation amplitudes can be obtained, quickly and reliably. In this article the concept of threshold power conditions is introduced and defined analytically. The contribution of parameters such as liquid-nitrogen cooling efficiency, thermal contact conductance and interface contact area of the crystal with the cooling base is evaluated. The optimal crystal illumination and the base temperature are inferred, which help minimize the optics deformation. The model has been examined using finite-element analysis studies performed for several beamlines of the Diamond-II upgrade.

3.
Nat Commun ; 14(1): 4582, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37524749

RESUMO

Visible light optical elements such as lenses and mirrors have counterparts for X-rays. In the visible regime, a variable focusing power can be achieved by an Alvarez lens which consists of a pair of inline planar refractors with a cubic thickness profile. When the two refractors are laterally displaced in opposite directions, the parabolic component of the wavefront is changed resulting in a longitudinal displacement of the focus. This paper reports an implementation of this concept for X-rays using two planar microfabricated refractive elements. The Alvarez X-ray lens can vary the focal distance of an elliptical X-ray mirror or a planar compound X-ray lens over several millimetres. The study presents the first demonstration of an Alvarez X-ray lens which adaptively corrects defocus and astigmatism aberrations of X-ray optics. In addition, the Alvarez X-ray lens eliminates coma aberration in an elliptical mirror, to the lowest order, when combining the lens with an adjustment of the pitch angle of the mirror.

4.
Opt Express ; 30(11): 19185-19198, 2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-36221703

RESUMO

Aberrations introduced during fabrication degrade the performance of X-ray optics and their ability to achieve diffraction limited focusing. Corrective optics can counteract these errors by introducing wavefront perturbations prior to the optic which cancel out the distortions. Here we demonstrate two-dimensional wavefront correction of an aberrated Kirkpatrick-Baez mirror pair using adaptable refractive structures. The resulting two-dimensional wavefront is measured using hard X-ray ptychography to recover the complex probe wavefield with high spatial resolution and model the optical performance under coherent conditions. The optical performance including the beam caustic, focal profile and wavefront error is examined before and after correction with both mirrors found to be diffraction limited after correcting. The results will be applicable to a wide variety of high numerical aperture X-ray optics aiming to achieve diffraction limited focussing using low emittance sources.

5.
J Synchrotron Radiat ; 29(Pt 2): 377-385, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35254300

RESUMO

Crystal monochromators are often the primary optics in hard X-ray synchrotron beamlines. Management of power load is central to their design. Strict requirements on stability and deformation are to be met, as new-generation synchrotron sources deliver brighter beams of X-rays. This article sets out to illustrate an overall picture of the deformation caused by heat load in a cryo-cooled Si crystal monochromator using first principles. A theoretical model has been developed to predict the temperature distribution and surface deformation by applying intrinsic properties of Si material and the cooling system parameters. The model explains the universal behaviour of crystal slope error versus absorbed power; it has been benchmarked against experimental data and used to interpret finite-element analysis of cryogenically cooled crystals.

6.
Int J Occup Saf Ergon ; 27(1): 1-7, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30205763

RESUMO

Introduction. This research is an attempt to show the role of interior layout of equipment in generating magnetic fields. Materials and methods. The levels of an extremely low-frequency magnetic field were measured in accordance with Standard No. IEEE 644:1994 in three substations and a control building in a petrochemical power plant in southern Iran. Then, workers' occupational exposure (time-weighted average [TWA]) was calculated and the sources of maximum magnetic field generation at each place were identified. Their interior design was changed to achieve the optimal layout of equipment subsequently; the workers' TWA was recalculated for the new situation. Results. The obtained results showed that electrical engineers and technicians were exposed to the maximum TWA of 10.14 µT. The operators in the control room were exposed to the lowest TWA of 0.84 µT. The results also showed that after the change of interior design and proper layout design of the equipment in the substations, the TWA was reduced by 0.73 µT. Conclusion. The research findings revealed that the most harmonious arrangement of equipment in an industrial unit plays a major role in reducing the exposure of workers to magnetic fields and ultimately increases the level of their health in the workplace.


Assuntos
Campos Eletromagnéticos , Exposição Ocupacional , Humanos , Irã (Geográfico) , Campos Magnéticos , Exposição Ocupacional/análise , Local de Trabalho
7.
Environ Monit Assess ; 187(5): 258, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25877640

RESUMO

Electromagnetic fields in recent years have been discussed as one of the occupational hazards at workplaces. Hence, control and assessment of these physical factors is very important to protect and promote the health of employees. The present study was conducted to determine hazard zones based on assessment of extremely low-frequency magnetic fields at electric substations of a petrochemical complex in southern Iran, using the single-axis HI-3604 device. In measurement of electromagnetic fields by the single-axis HI-3604 device, the sensor screen should be oriented in a way to be perpendicular to the field lines. Therefore, in places where power lines are located in different directions, it is required to keep the device towards three axes of x, y, and z. For further precision, the measurements should be repeated along each of the three axes. In this research, magnetic field was measured, for the first time, in three axes of x, y, and z whose resultant value was considered as the value of magnetic field. Measurements were done based on IEEE std 644-1994. Further, the spatial changes of the magnetic field surrounding electric substations were stimulated using MATLAB software. The obtained results indicated that the maximum magnetic flux density was 49.90 µT recorded from boiler substation, while the minimum magnetic flux density of 0.02 µT was measured at the control room of the complex. As the stimulation results suggest, the spaces around incoming panels, transformers, and cables were recognized as hazardous zones of indoor electric substations. Considering the health effects of chronic exposure to magnetic fields, it would be possible to minimize exposure to these contaminants at workplaces by identification of risky zones and observation of protective considerations.


Assuntos
Exposição Ambiental/estatística & dados numéricos , Monitoramento Ambiental/métodos , Campos Magnéticos , Indústria Química , Eletricidade , Exposição Ambiental/análise , Indústrias Extrativas e de Processamento , Humanos , Irã (Geográfico) , Medição de Risco/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-24904752

RESUMO

BACKGROUND: Advances in science and technology of electrical equipment, despite increasing human welfare in everyday life, have increased the number of people exposed to Electro-Magnetic Fields (EMFs). Because of possible adverse effects on the health of exposed individuals, the EMFs have being the center of attention. This study was performed to determine possible correlation between Extremely Low Frequency Electro-Magnetic Fields (ELF EMFs) and sleep quality and public health of those working in substation units of a petrochemical complex in southern Iran. MATERIALS AND METHOD: To begin with, magnetic flux density was measured at different parts of a Control Building and two substations in accordance with IEEE std 644-1994. Subsequently, the questionnaires "Pittsburgh Sleep Quality Index" (PSQI) and "General Health Quality (GHQ)" were used to investigate relationship between ELF exposure level and sleep quality and public health, respectively. Both questionnaires were placed at disposal of a total number of 40 workers at the complex. The filled out questionnaires were analyzed by T-test, Duncan and the Chi-square tests. RESULTS: The obtained results revealed that 28% of those in case group suffered from poor health status and 61% were diagnosed with a sleep disorder. However, all members in control group were in good health condition and only 4.5% of them had undesirable sleep quality. CONCLUSION: In spite of a significant difference between the case and control groups in terms of sleep quality and general health, no significant relationship was found between the exposure level and sleep quality and general health. It is worth noting that the measured EMF values were lower than the standard limits recommended by American Conference of Industrial Hygienists (ACGIH). However, given the uncertainties about the pathogenic effects caused by exposure to ELF EMFs, further epidemiological studies and periodic testing of personnel working in high voltage substations are of utmost importance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...