Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Clin Chim Acta ; : 119851, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38977172

RESUMO

BACKGROUND: Observable quantitative variations exist between plasma and serum in routine protein measurements, often not reflected in standard reference intervals. In this study, we describe an indirect approach for estimating a combined reference interval (RI) (i.e., serum and plasma), for commonly ordered protein measurands: total protein, albumin, and globulin. METHODS: We applied an indirect reference interval estimation for protein measurements in serum and plasma using data from July 2018 to February 2024. The data were divided into three Epochs based on a period of plasma separator tube shortage during the COVID-19 pandemic. Bootstrap resampling was used to calculate RIs and corresponding 95% confidence intervals for each month. RESULTS: Our results demonstrate notable changes in RI limits for total protein, albumin, and globulin between Epochs, reflecting the influence of changing sample matrix. A combined RI was identified for all components and verified using plasma and serum samples from 20 healthy individuals and retrospective analysis of flagging rates on our outpatient population using new and historical RIs. CONCLUSION: The study demonstrates notable differences in the RIs for total protein, albumin, and globulin when container type changes. In addition, the results demonstrate the effectiveness of big data analytics in deriving RIs and highlights the necessity of continuous RI assessment and adjustment based on the patient population and acceptable specimen types.

2.
Clin Chim Acta ; 561: 119829, 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38917868

RESUMO

BACKGROUND-AIM: Pregnancy induces physiological changes that can affect serologic and immunologic markers, potentially resulting in lower or undetectable haptoglobin values compared to non-pregnant counterparts. Such variations may lead to inaccurate diagnosis of hemolysis. METHODS: We report a case of a patient in second trimester of pregnancy receiving induction chemotherapy due to B-cell acute lymphocytic leukemia with undetectable haptoglobin levels in a routine laboratory sample collected less than 12 h posttransfusion of red cell unit. Despite undetectable haptoglobin, lactate dehydrogenase (LD) was within reference intervals (RI). The patient was evaluated for acute hemolytic transfusion reaction (AHTR) and followed up. Haptoglobin levels showed an upward trend during follow-up visits, reaching 15 mg/dL, and within RI in the third trimester. RESULTS: The patient did not meet the Center for Disease Control (CDC) criteria for AHTR. Alternative explanations for the observed laboratory findings were explored. Undetectable haptoglobin levels were attributed to various factors, including recent RBC transfusion, pregnancy-related physiological changes, and potential hyperhydration treatment plan due to chemotherapy. CONCLUSION: This case underscores the importance of cautious interpretation of laboratory results in pregnant patients, necessitating trimester-specific reference intervals for haptoglobin. A multidisciplinary approach to patient care is crucial for accurate diagnosis and management.

3.
Radiol Case Rep ; 19(8): 3363-3366, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38832339

RESUMO

Radiation induced cholecystitis is a known but rare complication of Yttrium90 (Y90) radioembolization of hepatic tumors due to nontarget embolization. Many documented cases of radiation induced cholecystitis have been treated with cholecystectomy, which is significant given the typical patient population undergoing radioembolization tends to be of higher surgical risk. Here, we present a case of a 68 year old male who developed radiation induced cholecystitis status post hepatic radioembolization that resolved with conservative management alone. This case highlights that radiation induced cholecystitis may be successfully and safely treated conservatively.

7.
Clin Chem ; 70(6): 805-819, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38299927

RESUMO

BACKGROUND: Acute kidney injury (AKI) is a serious complication affecting up to 15% of hospitalized patients. Early diagnosis is critical to prevent irreversible kidney damage that could otherwise lead to significant morbidity and mortality. However, AKI is a clinically silent syndrome, and current detection primarily relies on measuring a rise in serum creatinine, an imperfect marker that can be slow to react to developing AKI. Over the past decade, new innovations have emerged in the form of biomarkers and artificial intelligence tools to aid in the early diagnosis and prediction of imminent AKI. CONTENT: This review summarizes and critically evaluates the latest developments in AKI detection and prediction by emerging biomarkers and artificial intelligence. Main guidelines and studies discussed herein include those evaluating clinical utilitiy of alternate filtration markers such as cystatin C and structural injury markers such as neutrophil gelatinase-associated lipocalin and tissue inhibitor of metalloprotease 2 with insulin-like growth factor binding protein 7 and machine learning algorithms for the detection and prediction of AKI in adult and pediatric populations. Recommendations for clinical practices considering the adoption of these new tools are also provided. SUMMARY: The race to detect AKI is heating up. Regulatory approval of select biomarkers for clinical use and the emergence of machine learning algorithms that can predict imminent AKI with high accuracy are all promising developments. But the race is far from being won. Future research focusing on clinical outcome studies that demonstrate the utility and validity of implementing these new tools into clinical practice is needed.


Assuntos
Injúria Renal Aguda , Biomarcadores , Humanos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/sangue , Biomarcadores/sangue , Cistatina C/sangue , Aprendizado de Máquina , Inteligência Artificial
8.
Clin Chem Lab Med ; 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38377044

RESUMO

Recreational use of nitrous oxide (N2O) has become a major health issue worldwide, with a high number of clinical events, especially in neurology and cardiology. It is essential to be able to detect and monitor N2O abuse to provide effective care and follow-up to these patients. Current recommendations for detecting N2O in cases of recreational misuse and consumption markers are lacking. We aimed to update current knowledge through a review of the literature on N2O measurement and kinetics. We reviewed the outcomes of experiments, whether in preclinical models (in vitro or in vivo), or in humans, with the aim to identify biomarkers of intoxication as well as biomarkers of clinical severity, for laboratory use. Because N2O is eliminated 5 min after inhalation, measuring it in exhaled air is of no value. Many studies have found that urine and blood matrices concentrations are connected to ambient concentrations, but there is no similar data for direct exposure. There have been no studies on N2O measurement in direct consumers. Currently, patients actively abusing N2O are monitored using effect biomarkers (biomarkers related to the effects of N2O on metabolism), such as vitamin B12, homocysteine and methylmalonic acid.

12.
Radiographics ; 43(8): e230029, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37440450

RESUMO

Interventional radiology (IR) plays a unique and often invaluable role in the care of pregnant patients. Special considerations regarding radiation exposure and medication choice must be taken into account when evaluating a pregnant patient for an interventional procedure. In addition, the physiologic changes that occur during pregnancy can pose special challenges for an interventionalist when treating this patient population and should be appropriately recognized. Still, the majority of standard IR procedures can be safely performed in the pregnant population, often with additional precautions and proper patient education about the risks, benefits, and alternatives. In many cases, interventional radiologists can provide lifesaving and fertility-preserving alternatives to more invasive surgical intervention. The authors summarize radiation exposure effects and guidelines and medication choice during pregnancy. The physiologic changes that occur during pregnancy are discussed, with specific interest in the pathologic consequences that can be treated with IR. The authors also describe a wide variety of minimally invasive image-guided procedures offered by IR in pregnant, peripartum, or postpartum patients. The areas where IR can help in the treatment of pregnant patients include venous access, biopsies, genitourinary and biliary interventions, venous thromboembolism treatments, ectopic pregnancy management, aneurysm intervention, and management of trauma patients. IR is also involved in management during the peripartum or postpartum periods, with roles in treatment of invasive placenta spectrum, postpartum hemorrhage after vaginal delivery, and postcesarean delivery complications. ©RSNA, 2023 Supplemental material is available for this article. Quiz questions for this article are available through the Online Learning Center.


Assuntos
Lesões por Radiação , Radiologia Intervencionista , Gravidez , Feminino , Humanos , Lesões por Radiação/etiologia
13.
Am J Clin Pathol ; 160(5): 541, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37449363
15.
Clin Toxicol (Phila) ; 61(4): 248-259, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37129223

RESUMO

BACKGROUND: Many states in the United States have progressed towards legalization of marijuana including decriminalization, medicinal and/or recreational use. We studied the impact of legalization on cannabis-related emergency department visits in states with varying degrees of legalization. METHODS: Seventeen healthcare institutions in fifteen states (California, Colorado, Connecticut, Florida, Iowa, Kentucky, Maryland, Massachusetts, Missouri, New Hampshire, Oregon, South Carolina, Tennessee, Texas, Washington) participated. Cannabinoid immunoassay results and cannabis-related International Classification of Diseases (ninth and tenth versions) codes were obtained for emergency department visits over a 3- to 8-year period during various stages of legalization: no state laws, decriminalized, medical approval before dispensaries, medical dispensaries available, recreational approval before dispensaries and recreational dispensaries available. Trends and monthly rates of cannabinoid immunoassay and cannabis-related International Classification of Diseases code positivity were determined during these legalization periods. RESULTS: For most states, there was a significant increase in both cannabinoid immunoassay and International Classification of Diseases code positivity as legalization progressed; however, positivity rates differed. The availability of dispensaries may impact positivity in states with medical and/or recreational approval. In most states with no laws, there was a significant but smaller increase in cannabinoid immunoassay positivity rates. CONCLUSIONS: States may experience an increase in cannabis-related emergency department visits with progression toward marijuana legalization. The differences between states, including those in which no impact was seen, are likely multifactorial and include cultural norms, attitudes of local law enforcement, differing patient populations, legalization in surrounding states, availability of dispensaries, various ordering protocols in the emergency department, and the prevalence of non-regulated cannabis products.


Assuntos
Canabinoides , Cannabis , Maconha Medicinal , Estados Unidos , Humanos , Colorado/epidemiologia , Legislação de Medicamentos , Serviço Hospitalar de Emergência
19.
Clin Biochem ; 112: 6-10, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36535386

RESUMO

BACKGROUND: Urine drug testing (UDT) monitors prescription compliance and/or drug abuse. However, interpretation of UDT results obtained by liquid chromatography-tandem mass spectrometry (LC-MS-MS) can be complicated by the presence of drug impurities that are detected by highly sensitive methods. Hydrocodone is a drug impurity that can be found as high as 1% in oxycodone pills. OBJECTIVES: We evaluated the frequency and concentration of hydrocodone and its metabolite, hydromorphone, in patients taking oxycodone to check if the ratio of hydrocodone or hydromorphone to oxycodone could distinguish between oxycodone only use from those consuming additional opiates. DESIGN & METHODS: We correlated LC-MS/MS results with medication records of 319 patients with positive oxycodone results over 7 months (4/2021-11/2021). RESULTS: Fifteen of 319 patients with positive oxycodone results were taking oxycodone only. For these 15 patients, the mean ratio of hydrocodone to oxycodone was 0.57% (range 0.05%-3.35%), and the mean ratio of hydromorphone to oxycodone was 0.81% (range 0.18-3.51%). CONCLUSIONS: Hydrocodone and/or hydromorphone are detectable in patients taking only oxycodone and can likely be identified as an impurity if their calculated ratio to oxycodone is <1 %. Further validation of the ratios in a larger sample size is recommended.


Assuntos
Hidrocodona , Transtornos Relacionados ao Uso de Opioides , Humanos , Hidrocodona/análise , Hidromorfona/análise , Oxicodona , Analgésicos Opioides , Cromatografia Líquida/métodos , Oximorfona , Espectrometria de Massas em Tandem/métodos
20.
Clin Biochem ; 115: 112-115, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35882276

RESUMO

Icterus, a phenomenon caused by bilirubin elevation in the blood, is a common endogenous interference in chemistry testing, occurring either spectrally or through chemical reactivity with assay reagents. Often, laboratories have few options other than to dilute or reject samples exceeding icteric thresholds. However, recent studies have optimized in vitro photoisomerization of bilirubin to a 17-minute bilirubin half-life using 500 nm light at 37 °C. Using an enzymatic creatinine assay as a model, due to its prevalence in routine laboratory testing and susceptibility to icteric interference, our study explores the usage of in vitro photoisomerization by replicating these conditions in a device, the Bilibox, as means of resolving icterus in laboratory testing. Left-over icteric and non-icteric clinical samples, collected by lithium heparin vacutainer (n = 10), were analyzed for baseline creatinine, diluted creatinine (1:4 0.9 % NaCl), total bilirubin, direct bilirubin, and hemolysis, icterus and lipemia (HIL) indices. Samples were then placed in the Bilibox in two intervals of 30 min with repeat measurements of the aforementioned analytes. On average, icteric-index, total bilirubin (TBIL), and direct bilirubin (DBIL) decreased by 33.5, 39.1 and 39.9 % respectively following 30 min of Bilibox treatment; and by 47.6 %, 63.7 % and 59.8 % following 60 min. The average percent difference between the pre-exposure diluted and undiluted creatinine was 5.8 %, demonstrating the icterus interference. Following Bilibox treatment, the difference between undiluted (post-exposure) and diluted (pre-exposure) creatinine decreased to 0.02 % (p = 0.0232) and 2.2 % (p = 0.0021) at 30 and 60 min of treatment respectively, demonstrating resolution of interference. Consequently, photoisomerization can be utilized as an additional and reasonably quick method for resolving icterus when dilutional methods cannot be applied.


Assuntos
Icterícia , Humanos , Creatinina , Bilirrubina , Hemólise , Bioensaio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...