Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 19322, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37935729

RESUMO

The immune response in patients with Coronavirus Disease 2019 (COVID-19) is highly variable and is linked to disease severity and mortality. However, antibody and cytokine responses in the early disease stage and their association with disease course and outcome are still not completely understood. In this large, multi-centre cohort study, blood samples of 434 Belgian COVID-19 hospitalized patients with different disease severities (ranging from asymptomatic/mild to critically ill) from the first wave of the COVID-19 pandemic were obtained. Baseline antibody and cytokine responses were characterized and associations with several clinical outcome parameters were determined. Anti-spike immunoglobulin (Ig)G and IgM levels were elevated in patients with a more severe disease course. This increased baseline antibody response however was associated with decreased odds for hospital mortality. Levels of the pro-inflammatory cytokines IL-6, IP-10 and IL-8, the anti-inflammatory cytokine IL-10 and the antiviral cytokines IFN-α, IFN-ß and IFN-λ1 were increased with disease severity. Remarkably, we found significantly lower levels of IFN-λ2,3 in critically ill patients compared to patients of the moderate and severe disease category. Finally, levels of IL-8, IL-6, IP-10, IL-10, IFN-α, IFN-ß, IFN-γ and IFN-λ1 at baseline were positively associated with mortality, whereas higher IFN-λ2,3 levels were negatively associated with mortality.


Assuntos
COVID-19 , Humanos , Interleucina-10 , Interleucina-6 , Quimiocina CXCL10 , Interleucina-8 , Pandemias , Estado Terminal , Bélgica/epidemiologia , Estudos de Coortes , Citocinas , Interferon-alfa , Imunoglobulina G
2.
Eur J Clin Microbiol Infect Dis ; 39(12): 2441-2445, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32661809

RESUMO

Viral infections are common complications of pregnancy, with a wide range of obstetric and neonatal sequelae. Currently, there are limited data on whether SARS-CoV-2 is vertically transmitted in pregnant women tested positive for the virus. Here we describe a case of a known SARS-CoV-2-positive woman giving preterm birth to two fetuses with SARS-CoV-2 positive testing in placental tissue and amniotic fluid. The placental histological examinations showed chronic intervillositis and extensive intervillous fibrin depositions with ischemic necrosis of the surrounding villi.


Assuntos
Betacoronavirus/patogenicidade , Infecções por Coronavirus/transmissão , Diabetes Gestacional/diagnóstico , Transmissão Vertical de Doenças Infecciosas , Pneumonia Viral/transmissão , Complicações Infecciosas na Gravidez/diagnóstico , Nascimento Prematuro/virologia , Adulto , Líquido Amniótico/virologia , COVID-19 , Cesárea , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/patologia , Infecções por Coronavirus/virologia , Diabetes Gestacional/patologia , Diabetes Gestacional/virologia , Feminino , Morte Fetal , Feto , Humanos , Pandemias , Placenta/patologia , Placenta/virologia , Pneumonia Viral/diagnóstico , Pneumonia Viral/patologia , Pneumonia Viral/virologia , Gravidez , Complicações Infecciosas na Gravidez/patologia , Complicações Infecciosas na Gravidez/virologia , Nascimento Prematuro/patologia , SARS-CoV-2 , Gêmeos Dizigóticos
3.
J Clin Lab Anal ; 32(7): e22453, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29667731

RESUMO

BACKGROUND: Pre- and post-transfusion hemoglobin S (HbS) levels are used to document the efficacy of red blood cell exchange (RCE) in patients with sickle cell disease (SCD). In case of urgent RCE a 24/7 short turn-around time (STAT) analysis, with the ability to identify and quantify HbS, is warranted. The use of TOSOH G8 (Tosoh Europe) is evaluated for this purpose, using the variant HbA1c mode. METHODS: Analytical performance of the HbS analysis on TOSOH G8 in variant HbA1c mode was evaluated, including assessment of imprecision and linearity for HbS. In addition, a comparison study between TOSOH G8 and Minicap Flex Piercing (FP) system CZE (Sebia) using 32 HbS samples (HbS range: 9%-93%) was carried out to evaluate analytical and clinical concordance. RESULTS: Total HbS imprecision was 1.77% and 0.31% for a sickle cell trait and a sickle cell anemia sample, respectively. An acceptable linearity (HbS range: 6%-88%) was observed (R2  > .99). Passing-Bablok regression analysis showed a significant proportional bias; however, a good analytical concordance (r > .95) was found. Our results suggested that TOSOH G8 underestimated HbS results compared with those of Minicap FP system (mean difference: -3.54%), especially in samples with a high HbS concentration. CONCLUSION: Hemoglobin S results obtained with TOSOH G8 in variant HbA1c mode are clinically acceptable to monitor urgent RCE. The observed underestimation will not alter clinical decision-making.


Assuntos
Anemia Falciforme , Transfusão de Eritrócitos , Hemoglobinas Glicadas/análise , Hemoglobina Falciforme/análise , Hemoglobinometria , Anemia Falciforme/epidemiologia , Anemia Falciforme/terapia , Hemoglobinometria/métodos , Hemoglobinometria/normas , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Fatores de Tempo
4.
Am J Clin Pathol ; 146(3): 361-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27543981

RESUMO

OBJECTIVES: We evaluated the performance of a novel capillary isoelectric focusing (CIEF) application for hemoglobinopathy screening on the recently introduced V8 E-Class platform. METHODS: Analytical performance of the V8 E-Class was evaluated and included assessment of hemoglobin A2 (HbA2) imprecision; linearity for HbA2, fetal hemoglobin (HbF), and sickle hemoglobin (HbS); and carryover for HbS. Furthermore, a method comparison with the Minicap Flex Piercing (Sebia, Lisses, France), the Variant Classic (Bio-Rad Laboratories, Hercules, CA), and the G8 (Tosoh Europe, Amsterdam, the Netherlands) was done to assess analytical and clinical concordance. RESULTS: Total HbA2 imprecision was 3.26% and 3.14% for normal and elevated HbA2 controls and 5.16% and 3.58% for a normal and a heterozygous HbS patient sample, respectively. HbA2, HbF, and HbS showed acceptable linearity, and no carryover was observed. The method comparison showed good analytical concordance (r > 0.95) except for a homozygous HbS subset (r = 0.532-0.704). A comparable phenomenon was seen for the clinical concordance with good agreement in samples without variants (weighted κ > 0.80) but poorer agreement in HbS samples (κ < 0.30). CONCLUSIONS: Good analytical performance was demonstrated for this novel CIEF application for hemoglobinopathy screening. Method comparison showed generally good correlation but highlights the need for standardization. Finally, software optimization could further add to its use for routine hemoglobinopathy screening.


Assuntos
Hemoglobina Fetal/análise , Hemoglobina A2/análise , Hemoglobina Falciforme/análise , Hemoglobinopatias/diagnóstico , Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Humanos , Focalização Isoelétrica/instrumentação , Focalização Isoelétrica/métodos , Reprodutibilidade dos Testes
5.
Acta Clin Belg ; 71(6): 458-461, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27368113

RESUMO

OBJECTIVE AND IMPORTANCE: Suspected hemoglobin (Hb) variants, detected during HbA1C measurements should be further investigated, determining the extent of the interference with each method. CLINICAL PRESENTATION: This is the first report of Hb Melusine and Hb Athens-Georgia in Caucasian Belgian patients. Intervention & Technique: Since common CE-HPLC methods for HbA1C analysis or Hb variant screening are apparently unable to detect these Hb variants, their presence might be underestimated. HbA1C analysis using CZE, however, alerted for their presence. Moreover, in case of Hb Melusine, even Hb variant screening using CZE was unsuccessful in its detection. CONCLUSION: Fortunately, carriage of Hb Melusine or Hb Athens-Georgia variants has no clinical implications and, as shown in this report, no apparent difference in HbA1C should be expected.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Diabetes Mellitus/sangue , Hemoglobinas Glicadas/análise , Hemoglobinas Anormais/análise , Programas de Rastreamento/métodos , Idoso , Bélgica/epidemiologia , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência
6.
Acta Clin Belg ; 71(3): 167-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27098765

RESUMO

INTRODUCTION: We present a case of an arterial blood gas sample analysis from a 33-year old woman where no oximetry results could be obtained using the Radiometer ABL800 FLEX device. Clinical history of this patient learned that she was carrier of a methemoglobin forming hemoglobin variant type Hyde Park (HbM Hyde Park) and raised the question whether or not this variant could be the cause of the errors obtained during analysis. MATERIALS AND METHODS: A literature search was performed, focusing on methemoglobin forming hemoglobin variants and their influence on oxygenation measurements. An overview of the currently described methemoglobin forming hemoglobin variants is also included. RESULTS AND DISCUSSION: In the presence of dyshemoglobins such as methemoglobin, techniques used to obtain parameters that reflect the patient oxygenation status, such as pulse oximetry and CO-oximetry can be influenced. In these cases, CO-oximetry is the preferred technique because it can compensate for this, in contrast to pulse oximetry. In case of the presence of methemoglobin originating from a hemoglobin variant, it is possible that CO-oximetry data cannot be calculated because the absorbance spectrum of this methemoglobin can differ from regular methemoglobin. Moreover, pulse oximetry devices are actually prone to erroneous results since pulse oximetry data will be calculated in these cases, but unreliable and should be avoided. CONCLUSION: Methemoglobin forming hemoglobin variants are rare genetic mutations. However, they can possibly interfere with the calculation of CO-oximetry values. In these cases, pulse oximetry data should be avoided because they could lead to incorrect medical decisions.


Assuntos
Gasometria , Hemoglobina M , Hemoglobinas , Metemoglobina , Adulto , Erros de Diagnóstico , Análise de Falha de Equipamento , Feminino , Hemoglobina M/análise , Hemoglobina M/química , Hemoglobinas/análise , Hemoglobinas/química , Humanos , Metemoglobina/análise , Metemoglobina/química , Mutação , Oximetria
8.
Hemoglobin ; 39(6): 435-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26372398

RESUMO

We report the case of a 56-year-old Caucasian woman in whom hemoglobinopathy screening was triggered following an aberrant Hb A1c analysis. Preliminary diagnosis of the hemoglobin (Hb) variant was obtained through cation exchange high performance liquid chromatography (HPLC) and gel electrophoresis. DNA analysis confirmed the presence of Hb J-Amiens [ß17(A14)Lys→Asn; HBB: c.[54G > C or 54G > T)]. However, an unbalanced ratio between wild type and mutant signal after direct sequencing and a lower than expected percentage of this Hb variant led to the suggestion of a mosaic expression. Furthermore, different methods [capillary zone electrophoresis (CZE), cation exchange HPLC and boronate affinity] were tested to study the possible interference of this variant with Hb A1c measurements. These investigations showed a clinically relevant difference between the methods tested. Hb A1c analysis may lead to the discovery of new Hb variants or mosaicism for previously described Hb variants. This may have genetic consequences for the offspring of carriers and brings about the question of partner testing.


Assuntos
Hemoglobinas Glicadas/genética , Hemoglobina J/genética , Hemoglobina J/metabolismo , Fenótipo , Substituição de Aminoácidos , Códon , Análise Mutacional de DNA , Índices de Eritrócitos , Feminino , Expressão Gênica , Genótipo , Hemoglobinas Glicadas/metabolismo , Hemoglobinopatias/diagnóstico , Hemoglobinopatias/genética , Humanos , Pessoa de Meia-Idade , Mutação , Globinas beta/genética
9.
Clin Chim Acta ; 441: 63-70, 2015 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-25523192

RESUMO

BACKGROUND: Accurate quantification of vancomycin in plasma is important for adequate dose-adjustment. As literature suggests between-method differences, our first objective was to develop a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for total vancomycin in human plasma and to compare frequently used immunoassays with this method. Secondly, we investigated the clinical impact of between-method quantification differences. METHODS: For LC-MS/MS, lithium heparin plasma was extracted by adding a precipitation reagent containing the internal standard (vancomycin-des-leucine). Analysis was performed on an Acquity TQD mass spectrometer equipped with an Acquity UPLC 2795 separations module. Our method was analytically validated and compared with four frequently used immunoassays from four different manufacturers. Vancomycin concentrations were clinically classified as toxic, therapeutic and sub-therapeutic. Clinical discordance was calculated using LC-MS/MS as a reference. RESULTS: A novel LC-MS/MS method using protein precipitation as sole pretreatment and an analysis time of 5.0 min was developed. The assay had a total imprecision of 2.6-8.5%, a limit of quantification of 0.3 mg/L and an accuracy ranging from 101.4 to 111.2%. Using LC-MS/MS as reference, three immunoassays showed a mean proportional difference within 10% and one showed a substantial mean proportional difference of >20%. Clinical discordant interpretation of the obtained concentrations ranged from 6.1 to 22.2%. CONCLUSIONS: We developed a novel LC-MS/MS method for rapid analysis of total vancomycin concentrations in human plasma. Correlation of the method with immunoassays showed a mean proportional difference >20% for one of the assays, causing discordant clinical interpretation in more than 1 out of 5 samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Imunoensaio , Espectrometria de Massas em Tandem/métodos , Vancomicina/sangue , Humanos
10.
Nucl Med Biol ; 33(3): 413-8, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16631091

RESUMO

Technetium(V)-oxo-3beta-(4-chlorophenyl)-8-methyl-8-azabicyclo[3.2.1]oct-2-yl[N-(2-mercaptoethyl), N-(N'-(2-mercaptoethyl)-2-aminoethyl)]-aminomethyl ((99m)Tc-TRODAT-1) and three derivatives with one or two substituents on the 3beta-phenyl ring (4-methylphenyl, 4-ethylphenyl and 2,4-dimethylphenyl) were prepared and evaluated as potential imaging agents for the central nervous dopamine transporter (DAT). Labeling of the ligands with (99m)Tc yielded for each of them a mixture of two radiolabeled species, which were purified and isolated using reversed-phase high-performance liquid chromatography. Employing radio-LC-MS, we found both species to have the same molecular mass suggesting diastereoisomers. After intravenous injection in mice and rats, the compounds were stable in vivo and no important metabolites were found in plasma or urine. Replacement of the 4-chloro atom on the 3beta-phenyl ring by a methyl group causes no loss of affinity for the DAT system. However, substitution of an ethyl group for the 4-chloro atom or introduction of a second methyl group in the 2-position of the phenyl ring results in a serious reduction of the affinity for the DAT transporter. Ex vivo autoradiography on mice brain slices and biodistribution studies in rats showed specific uptake of (99m)Tc-TRODAT-1 and the 4-methylphenyl derivative in striatum and putamen. Although the 4-ethylphenyl and 2,4-dimethylphenyl derivatives show brain uptake in rats and mice, no specific uptake in striatum was found. In addition, differences in biological behavior between the different diastereomers were observed. In conclusion, small changes to (99m)Tc-TRODAT-1 at the phenyl ring in the 3beta position of the tropane moiety significantly change the biological behavior of the studied compounds.


Assuntos
Encéfalo/diagnóstico por imagem , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Compostos de Organotecnécio , Tropanos , Animais , Encéfalo/metabolismo , Avaliação Pré-Clínica de Medicamentos , Masculino , Taxa de Depuração Metabólica , Especificidade de Órgãos , Compostos de Organotecnécio/química , Compostos de Organotecnécio/farmacocinética , Fenóis/química , Cintilografia , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Distribuição Tecidual , Tropanos/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA