Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 47(13): 3163-3166, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35776576

RESUMO

We show that 13-fs laser pulses associated with 225 TW of peak power can be used to produce laser wakefield acceleration (LWFA) and generate synchrotron radiation. To achieve this, 130-TW high-power laser pulses (3.2 J, 24 fs) are efficiently compressed down to 13 fs with the thin film compression (TFC) technique using large chirped mirrors after propagation and spectral broadening through a 1-mm-thick fused silica plate. We show that the compressed 13-fs laser pulse can be properly focused even if it induces a 10% degradation of the Strehl ratio. We demonstrate the usability of such a laser beam. We observe both an increase of the electron energy and of the betatron radiation critical energy when the pulse duration is reduced to 13 fs compared with the 24-fs case.

2.
Opt Express ; 28(9): 13978-13990, 2020 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-32403862

RESUMO

We demonstrate that a laser-based synchrotron X-ray source can be used to image and characterize in a single laser shot spherical capsules similar to ICF targets. Thus, we establish this source potential for real-time ultrafast imaging of the ICF laser driver interaction with the target. To produce the X-ray beam we used a 160 TW high power laser system with 3.2 J and 20 fs incident on a supersonic gas jet target at 2.5 Hz repetition rate. We produced 2.7 × 109 photons/0.1% BW/sr/shot at 10 keV with a critical energy Ec = 15.1 keV. In our experimental conditions the spatial resolution was 4.3 µm in the object plane. We show that it is feasible to image the capsule structure and experimentally retrieve the phase information.

3.
Opt Express ; 28(3): 3147-3158, 2020 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-32121988

RESUMO

We review the results obtained in several experimental campaigns with the INRS high-power laser system and determine the X-ray emission scaling from synchrotron radiation produced during laser wakefield acceleration (LWFA) of electrons. The physical processes affecting the generation of intense and stable X-ray beams during the propagation phase of the high-intensity ultrashort pulse in the gas jet target are discussed. We successfully produced stable propagation in the gas jet target of a relativistic laser pulse through self-guiding on length larger than the dephasing and depletion lengths, generating very intense beams of hard X-rays with up to 200 TW on target. The experimental scaling law obtained for the photon yield in the 10-40 keV range is presented and the level of X-ray emission at the 1 PW laser peak power level, now available at several laser facilities, is estimated.

4.
Sci Rep ; 7(1): 16463, 2017 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-29184108

RESUMO

A new type of proton acceleration stemming from large-scale gradients, low-density targets, irradiated by an intense near-infrared laser is observed. The produced protons are characterized by high-energies (with a broad spectrum), are emitted in a very directional manner, and the process is associated to relaxed laser (no need for high-contrast) and target (no need for ultra-thin or expensive targets) constraints. As such, this process appears quite effective compared to the standard and commonly used Target Normal Sheath Acceleration technique (TNSA), or more exploratory mechanisms like Radiation Pressure Acceleration (RPA). The data are underpinned by 3D numerical simulations which suggest that in these conditions a Low Density Collisionless Shock Acceleration (LDCSA) mechanism is at play, which combines an initial Collisionless Shock Acceleration (CSA) to a boost procured by a TNSA-like sheath field in the downward density ramp of the target, leading to an overall broad spectrum. Experiments performed at a laser intensity of 1020 W/cm2 show that LDCSA can accelerate, from ~1% critical density, mm-scale targets, up to 5 × 109 protons/MeV/sr/J with energies up to 45(±5) MeV in a collimated (~6° half-angle) manner.

5.
Phys Rev E ; 95(5-1): 053208, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28618605

RESUMO

Time-resolved measurements of the ionization states of warm dense aluminum via K-shell absorption spectroscopy are demonstrated using betatron radiation generated from laser wakefield acceleration as a probe. The warm dense aluminum is generated by irradiating a free-standing nanofoil with a femtosecond optical laser pulse and was heated to an electron temperature of ∼20-25 eV at a close-to-solid mass density. Absorption dips in the transmitted x-ray spectrum due to the Al^{4+} and Al^{5+} ions are clearly seen during the experiments. The measured absorption spectra are compared to simulations with various ionization potential depression models, including the commonly used Stewart-Pyatt model and an alternative modified Ecker-Kröll model. The observed absorption spectra are in approximate agreement with these models, though indicating a slightly higher state of ionization and closer agreement for simulations with the modified Ecker-Kröll model.

6.
Sci Rep ; 6: 27846, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27324915

RESUMO

Laser pulses in current ultra-short TW systems are far from being ideal Gaussian beams. The influence of the presence of non-Gaussian features of the laser pulse is investigated here from experiments and 3D Particle-in-Cell simulations. Both the experimental intensity distribution and wavefront are used as input in the simulations. It is shown that a quantitative agreement between experimental data and simulations requires to use realistic pulse features. Moreover, some trends found in the experiments, such as the growing of the X-ray signal with the plasma length, can only be retrieved in simulations with realistic pulses. The performances on the electron acceleration and the synchrotron X-ray emission are strongly degraded by these non-Gaussian features, even keeping constant the total laser energy. A drop on the X-ray photon number by one order of magnitude was found. This clearly put forward the limitation of using a Gaussian beam in the simulations.

7.
Rev Sci Instrum ; 84(12): 123106, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24387419

RESUMO

We have developed a laser wakefield generated X-ray probe to directly measure the temporal evolution of the ionization states in warm dense aluminum by means of absorption spectroscopy. As a promising alternative to the free electron excited X-ray sources, Betatron X-ray radiation, with femtosecond pulse duration, provides a new technique to diagnose femtosecond to picosecond transitions in the atomic structure. The X-ray probe system consists of an adjustable Kirkpatrick-Baez (KB) microscope for focusing the Betatron emission to a small probe spot on the sample being measured, and a flat Potassium Acid Phthalate Bragg crystal spectrometer to measure the transmitted X-ray spectrum in the region of the aluminum K-edge absorption lines. An X-ray focal spot size of around 50 µm was achieved after reflection from the platinum-coated 10-cm-long KB microscope mirrors. Shot to shot positioning stability of the Betatron radiation was measured resulting in an rms shot to shot variation in spatial pointing on the sample of 16 µm. The entire probe setup had a spectral resolution of ~1.5 eV, a detection bandwidth of ~24 eV, and an overall photon throughput efficiency of the order of 10(-5). Approximately 10 photons were detected by the X-ray CCD per laser shot within the spectrally resolved detection band. Thus, it is expected that hundreds of shots will be required per absorption spectrum to clearly observe the K-shell absorption features expected from the ionization states of the warm dense aluminum.

8.
Opt Express ; 19(15): 14093-8, 2011 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-21934771

RESUMO

We demonstrated the generation of infrared radiation by filamentation of a spectrally shaped femtosecond laser beam. The spectrum is divided in two distinctive parts using an acousto-optic programmable dispersive filter (AOPDF) as a pulse shaper, resulting in two pulses of different colors. One pulse is frequency doubled and the beams are then focused to produce an optical filament. Efficient infrared generation occurred in the filament zone through the four-wave mixing interaction. This in-line setup allowed perfect spatial overlap of the pulses, fine control of the relative delay and the remote control of the infrared spectral distribution through spectral shaping of the initial femtosecond laser beam via the AOPDF.

9.
Opt Lett ; 36(13): 2426-8, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21725433

RESUMO

Development of x-ray phase contrast imaging applications with a laboratory scale source have been limited by the long exposure time needed to obtain one image. We demonstrate, using the Betatron x-ray radiation produced when electrons are accelerated and wiggled in the laser-wakefield cavity, that a high-quality phase contrast image of a complex object (here, a bee), located in air, can be obtained with a single laser shot. The Betatron x-ray source used in this proof of principle experiment has a source diameter of 1.7 µm and produces a synchrotron spectrum with critical energy E(c)=12.3±2.5 keV and 109 photons per shot in the whole spectrum.


Assuntos
Lasers , Imagem Molecular/métodos , Animais , Abelhas , Calibragem , Estudos de Viabilidade , Fatores de Tempo , Raios X
10.
Opt Express ; 19(9): 8486-97, 2011 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-21643098

RESUMO

Laser matter interaction at relativistic intensities using 100 TW class laser systems or higher is becoming more and more widespread. One of the critical issues of such laser systems is to let the laser pulse interact at high intensity with the solid target and avoid any pre-plasma. Thus, a high Laser Pulse Contrast Ratio (LPCR) parameter is of prime importance. We present the LPCR characterization of a high repetition 100 TW class laser system. We demonstrate that the generated Amplified Spontaneous Emission (ASE) degrades the overall LPCR performance. We propose a simple way to clean the pulse after the first amplification stage by introducing a solid state saturable absorber which results in a LPCR improvement to better than 10(10) with only a 30% energy loss at a 10 Hz repetition rate. We finally correlated this cleaning method with experimental results.


Assuntos
Lasers , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Phys Rev Lett ; 106(2): 023001, 2011 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-21405226

RESUMO

We show that noncollinear high harmonic generation (HHG) can be fully understood in terms of nonlinear optical wave mixing. We demonstrate this by superposing on the fundamental ω1 field its second harmonic ω2 of variable intensity in a noncollinear geometry. It allows us to identify, by momentum conservation, each field's contribution (n1,n2) to the extreme ultraviolet emission at frequency Ω = n1ω1 + n2ω2. We observe that the photon (Ω) yield follows an n2 power law on the ω2 intensity, before saturation. It demonstrates that, although HHG is a highly nonperturbative process, a perturbation theory can still be developed around it.

12.
Opt Express ; 19(1): 230-40, 2011 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-21263561

RESUMO

We report measurements of crater diameter and surface ablation threshold as a function of laser fluence in porcine corneal stroma and fused silica with pulse durations of 7 fs (2.7 optical cycles), 30 fs and 100 fs at 800 nm. For laser pulses with Gaussian radial intensity profile, we show experimentally that the square of the crater diameter is a linear function of the logarithm of the fluence in fused silica, while it is closer to a linear function of the fluence in corneal stroma. Extrapolating these relations to zero diameter indicates that for both media the minimum fluence required for surface ablation is reduced with shorter pulse duration. A simple theoretical model suggests that this effect is due to a more significant contribution of photoionization as the laser pulse duration shortens.


Assuntos
Córnea/cirurgia , Cirurgia da Córnea a Laser/métodos , Animais , Cirurgia da Córnea a Laser/instrumentação , Desenho de Equipamento , Técnicas In Vitro , Modelos Teóricos , Dispositivos Ópticos , Fenômenos Ópticos , Dióxido de Silício , Suínos
13.
Phys Rev Lett ; 103(7): 073902, 2009 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-19792645

RESUMO

Using longer wavelength laser drivers for high harmonic generation is desirable because the highest extreme ultraviolet frequency scales as the square of the wavelength. Recent numerical studies predict that high harmonic efficiency falls dramatically with increasing wavelength, with a very unfavorable lambda(-(5-6)) scaling. We performed an experimental study of the high harmonic yield over a wavelength range of 800-1850 nm. A thin gas jet was employed to minimize phase matching effects, and the laser intensity and focal spot size were kept constant as the wavelength was changed. Ion yield was simultaneously measured so that the total number of emitting atoms was known. We found that the scaling at constant laser intensity is lambda(-6.3+/-1.1) in Xe and lambda(-6.5+/-1.1) in Kr over the wavelength range of 800-1850 nm, somewhat worse than the theoretical predictions.

14.
Opt Express ; 17(12): 9620-9, 2009 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-19506611

RESUMO

Nonlinear transient absorption bleaching of intense few-cycle terahertz (THz) pulses is observed in photoexcited GaAs using opticalpump--THz-probe techniques. A simple model of the electron transport dynamics shows that the observed nonlinear response is due to THz-electric- field-induced intervalley scattering over sub-picosecond time scales as well as an increase in the intravalley scattering rate attributed to carrier heating. Furthermore, the nonlinear nature of the THz pulse transmission at high peak fields leads to a measured terahertz conductivity in the photoexcited GaAs that deviates significantly from the Drude behavior observed at low THz fields, emphasizing the need to explore nonlinear THz pulse interactions with materials in the time domain.


Assuntos
Arsenicais/química , Arsenicais/efeitos da radiação , Gálio/química , Gálio/efeitos da radiação , Dispositivos Ópticos , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Radiação Terahertz
15.
Opt Express ; 17(1): 178-84, 2009 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-19129886

RESUMO

We report successful compensation of the thermally induced laser beam distortion associated with high energy 110 mJ and high average power femtosecond laser system of 11 Watts operated with vacuum compressor gratings. To enhance laser-based light source brightness requires development of laser systems with higher energy and higher average power. Managing the high thermal loading on vacuum optical components is a key issue in the implementation of this approach. To our knowledge this is the first time that such thermal induced distortions on the vacuum compressor gratings are characterized and compensated.


Assuntos
Desenho de Equipamento , Análise de Falha de Equipamento , Lasers , Óptica e Fotônica/métodos , Simulação por Computador , Luz , Microscopia de Fluorescência por Excitação Multifotônica , Modelos Teóricos , Fatores de Tempo , Vácuo
16.
Opt Express ; 16(21): 16284-93, 2008 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-18852734

RESUMO

We describe a dual, second harmonic generation (SHG) and third harmonic generation (THG) microscope, with the aim to obtain large-scale images of the cornea that can simultaneously resolve the micron-thick thin layers. We use an Ytterbium femtosecond laser as the laser source, the longer wavelength of which reduces scattering and allows simultaneous SHG and THG imaging. We measure one-dimensional SHG and THG profiles across the entire thickness of pig cornea, detected in both the forward and backward directions. These profiles allow us to clearly distinguish all the porcine corneal layers (epithelium, stroma, Descemet's membrane and endothelium). From these profiles, longitudinal cross sectional images of the corneal layers are generated, providing large scale topographic information with high-spatial resolution. The ability to obtain both SHG and THG signals in epi-detection on fresh eyes gives promising hopes for in vivo applications.


Assuntos
Algoritmos , Córnea/ultraestrutura , Topografia da Córnea/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Microscopia Confocal/métodos , Animais , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
17.
Phys Rev Lett ; 101(5): 053901, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18764392

RESUMO

We report a new dynamic two-center interference effect in high-harmonic generation from H2, in which the attosecond nuclear motion of H2+ initiated at ionization causes interference to be observed at lower harmonic orders than would be the case for static nuclei. To enable this measurement we utilize a recently developed technique for probing the attosecond nuclear dynamics of small molecules. The experimental results are reproduced by a theoretical analysis based upon the strong-field approximation which incorporates the temporally dependent two-center interference term.

18.
Opt Express ; 16(16): 11987-94, 2008 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-18679471

RESUMO

We successfully implemented laser beam wavefront correction on the 200 TW laser system at the Advanced Laser Light Source. Ultra high intensities in excess of 10(20) W/cm(2) have been demonstrated. This system is, to our knowledge, the first 100 TW class laser to combine simultaneously ultra high intensity, 10(9) laser pulse contrast ratio and 10 Hz high repetition rate.


Assuntos
Artefatos , Lasers , Lentes , Iluminação/instrumentação , Refratometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
19.
Science ; 320(5882): 1478-82, 2008 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-18556555

RESUMO

Molecular structure is usually determined by measuring the diffraction pattern the molecule impresses on x-rays or electrons. We used a laser field to extract electrons from the molecule itself, accelerate them, and in some cases force them to recollide with and diffract from the parent ion, all within a fraction of a laser period. Here, we show that the momentum distribution of the extracted electron carries the fingerprint of the highest occupied molecular orbital, whereas the elastically scattered electrons reveal the position of the nuclear components of the molecule. Thus, in one comprehensive technology, the photoelectrons give detailed information about the electronic orbital and the position of the nuclei.

20.
Opt Express ; 16(6): 4121-9, 2008 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-18542509

RESUMO

We measure the surface ablation threshold fluence of porcine corneal stroma for 100 fs laser pulses, with wavelengths between 800 nm and 1450 nm, generated by a Ti:sapphire-pumped optical parametric amplifier. The ablation threshold was found to vary only slightly within this wavelength range, between 1.5 and 2.2 J/cm(2). The data suggest a rapid increase of the ablation threshold for wavelengths up to about 1000 nm, followed by a plateau for longer wavelengths. This behavior is partly confirmed by a simple theoretical model of the ablation process. The influence of the wavelength on the physics of surface ablation is discussed on the basis of the model.


Assuntos
Substância Própria/fisiologia , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Modelos Biológicos , Cirurgia Assistida por Computador/métodos , Animais , Simulação por Computador , Substância Própria/anatomia & histologia , Limiar Diferencial/efeitos da radiação , Relação Dose-Resposta à Radiação , Técnicas In Vitro , Doses de Radiação , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...