Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sex Transm Infect ; 86(7): 532-6, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20656720

RESUMO

OBJECTIVE: The development of a rapid immunofiltration (flow-through) test for the simultaneous detection of non-treponemal and treponemal antibodies in the serum of patients with syphilis. METHODS: The assay is rapid, inexpensive, and requires limited expertise in interpreting the results. The test is based on the principle of immunofiltration, with two antigens and control material spotted on the membrane of a through-flow device. A positive test is characterised by the appearance of three red/magenta spots within 2-10 min. RESULTS: A total of 376 banked serum samples obtained from the Georgia Public Health Laboratory was examined by the flow-through test, the rapid plasma reagin (RPR) test and the Treponema pallidum passive particle agglutination assay (TPPA). The sensitivity and specificity of the non-treponemal spot were 96.5% and 97.7%, respectively, when compared with the RPR test, and the sensitivity and specificity of the treponemal test spot were 97.3% and 99.1% when compared with the TPPA test. In addition, the test yielded equivalent results to those obtained in comparator tests when 104 sera from cases of syphilis of known stage, 49 sera from diseases other than syphilis and 23 sera known to exhibit biological false-positive reactions were tested in parallel. CONCLUSIONS: These results indicate that the dual treponemal and non-treponemal assay could be used as a screen and confirmatory test for the serological diagnosis of syphilis in remote or resource-poor settings where there is a need to provide counselling and treatment at the initial consultation.


Assuntos
Anticorpos Antibacterianos/sangue , Sorodiagnóstico da Sífilis/instrumentação , Sífilis/diagnóstico , Treponema pallidum/isolamento & purificação , Desenho de Equipamento , Filtração , Humanos , Imunoensaio/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Treponema pallidum/imunologia
2.
J Clin Microbiol ; 38(7): 2543-5, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10878040

RESUMO

We compared the microhemagglutination assay for Treponema pallidum (MHA-TP), a treponemal test, with two other treponemal tests, the Serodia Treponema pallidum particle agglutination (TP-PA) assay and the Captia Syphilis-G enzyme immunoassay, using 390 clinical serum samples. We also compared two nontreponemal tests, the rapid plasma Reagin (RPR) card test and the SpiroTek Reagin II test. Agreements of the MHA-TP with the TP-PA test and the Syphilis-G test were 97.4 and 97.7%, respectively. There was 89.2% agreement between the RPR and Reagin II tests. The Reagin II test was more apt to be reactive if the treponemal test was also reactive. We conclude that either the Serodia TP-PA test or the Captia Syphilis-G test is an appropriate substitute for the MHA-TP and that the Spirotek Reagin II test could substitute for the RPR test as a screening test.


Assuntos
Anticorpos Antibacterianos/sangue , Reaginas/sangue , Sorodiagnóstico da Sífilis/métodos , Sífilis/diagnóstico , Treponema pallidum/imunologia , Testes de Hemaglutinação , Humanos , Técnicas Imunoenzimáticas , Sensibilidade e Especificidade , Sífilis/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...