Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
2.
Heart Rhythm ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39032523

RESUMO

BACKGROUND: Short-term antithrombotic therapy is recommended after left atrial appendage occlusion(LAAO) to reduce the risk of device-related thrombosis(DRT). However, patients referred for LAAO have excess bleeding risk. Yet, short-term bleeding events post-LAAO are not well characterized. OBJECTIVE: We aimed to evaluate the incidence of early bleeding post-LAAO and its association with long-term mortality risk. We also sought to identify predictors of early bleeding. METHODS: Patients who underwent LAAO at Mayo Clinic between 2018 and 2023 were included. Early bleeding was defined as bleeding that occurred within three months of discharge. A multivariable Cox proportional hazards model was used to assess the association between early bleeding and death and to estimate the hazard ratio(HR). Multivariable regression analysis was used to identify predictors of early bleeding. RESULTS: Among the 592 patients included, 389(66%) were male, and mean age was 75.6 years. Eighty-three patients(14.0%) experienced early bleeding, with the majority having minimal(63.4%) or minor(17.3%) bleeding. At a median follow-up of 14.4 months(IQR 4.2-27.9), early bleeding after LAAO was associated with an increased risk of all-cause mortality (adjustedHR, 2.07; 95%CI, 1.15-3.75; P=0.02). A history of intracranial bleeding, non-paroxysmal atrial fibrillation, CHA2DS2VASc score, and early DRT were independent predictors of early bleeding. Anti-thrombotic therapy on discharge was not associated with early non-procedural bleeding. CONCLUSIONS: One in seven patients experience a non-procedural bleeding event within 90 days after LAAO. Early bleeding after LAAO is associated with a higher all-cause mortality during mid-term follow-up. Further studies are needed to optimize the management of patients undergoing LAAO.

3.
Artigo em Inglês | MEDLINE | ID: mdl-39039649

RESUMO

INTRODUCTION: The impact of mRNA-based coronavirus disease-2019 (COVID-19) vaccines on atrial arrhythmias (AA) and ventricular arrhythmias incidence is unknown. METHODS: BIOTRONIK Home Monitoring data and Medicare Claims data were utilized to identify individuals implanted with a cardiac implantable electronic device (CIED) between 2010 and 2020 who received one or more doses of COVID-19 vaccine in 2021. The burden of AA (%) in the 3 months postvaccination was compared to those noted in the preceding 3 months using the Wilcoxon signed rank test. Sub-analyses comparing the effects of the influenza vaccine against the COVID-19 vaccine were also evaluated for individuals who received the influenza vaccine in 2020. A 1:1 propensity score match comparison between COVID-19 vaccine and non-vaccinated patients was also performed. RESULTS: First and second doses of the COVID-19 vaccine were administered to 7757 and 6579 individuals with a CIED (age 76.2 ± 9.0 years, 49% males), respectively. While a small but statistically significant increase in the burden of AA was noted in the 3 months postvaccination compared to the preceding 3 months after the first dose of the COVID-19 vaccine (0.43 ± 9.04%, p = .028) a similar rise in AA was found following the influenza vaccine and for matched patients who did not receive the COVID-19 vaccine. No significant difference in device therapies was seen pre- and postvaccination. CONCLUSIONS: Though we report a small but significant increase in the number of CIED-detected AAs following vaccination for COVID-19 over a 3-month window, we believe these results correlate more with time and the progressive nature of AF rather than the vaccine itself. While these data should not dissuade from the use of these vaccines, increased vigilance and prompt treatment of AF is required for high-risk groups, specifically males over 70 years of age, following vaccination.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38819352

RESUMO

BACKGROUND: The effects of disease-causing MYBPC3 or MYH7 genetic variants on atrial myopathy, atrial fibrillation (AF) clinical course, and catheter ablation efficacy remain unclear. OBJECTIVES: The aim of this study was to characterize the atrial substrate of patients with MYBPC3- or MYH7-mediated hypertrophic cardiomyopathy (HCM) and its impact on catheter ablation outcomes. METHODS: A retrospective single-center study of patients with HCM who underwent genetic testing and catheter ablation for AF was performed. Patients with MYBPC3- or MYH7-mediated HCM formed the gene-positive cohort; those without disease-causative genetic variants formed the control cohort. High-density electroanatomical mapping was performed using a 3-dimensional mapping system, followed by radiofrequency ablation. RESULTS: Twelve patients were included in the gene-positive cohort (mean age 55.6 ± 9.9 years, 83% men, 50% MYBPC3, 50% MYH7, mean ejection fraction 59.3% ± 13.7%, mean left atrial [LA] volume index 51.7 ± 13.1 mL/m2, mean LA pressure 20.2 ± 5.4 mm Hg) and 15 patients in the control arm (mean age 61.5 ± 12.6 years, 60% men, mean ejection fraction 64.9% ± 5.1%, mean LA volume index 54.1 ± 12.8 mL/m2, mean LA pressure 19.6 ± 5.41 mm Hg). Electroanatomical mapping demonstrated normal voltage in 87.7% ± 5.03% of the LA in the gene-positive cohort and 94.3% ± 3.58% of the LA in the control cohort (P < 0.001). Of the abnormal regions, intermediate scar (0.1-0.5 mV) accounted for 6.33% ± 1.97% in the gene-positive cohort and 3.07% ± 2.46% in the control cohort (P < 0.01). Dense scar (<0.1 mV) accounted for 5.93% ± 3.20% in the gene-positive cohort and 2.61% ± 2.19% in the control cohort (P < 0.01). Freedom from AF at 12 months was similar between the gene-positive (75%) and control (73%) cohorts (P = 0.92), though a greater number of procedures were required in the gene-positive cohort. CONCLUSIONS: Patients with MYBPC3- or MYH7-mediated HCM undergoing AF ablation have appreciably more low-amplitude LA signals, suggestive of fibrosis. However, catheter ablation remains an effective rhythm-control strategy.

5.
J Cardiovasc Electrophysiol ; 35(6): 1196-1202, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38590268

RESUMO

INTRODUCTION: Ventricular tachycardia storm or electrical storm (ES) is a common complication following left ventricular assist device (LVAD) implantation. The factors contributing to ES and outcomes are less studied. The study aimed to determine the factors associated with ES and the probability of survival in patients undergoing LVAD in three tertiary centers over a span of 15 years. METHODS: We performed a retrospective cohort study on all patients who underwent LVAD implantation at the Mayo Clinic (Rochester, Phoenix, and Jacksonville) from January 1, 2006 to December 31, 2020. ES was defined as ≥3 episodes of sustained ventricular tachycardia over a period of 24 h with no identifiable reversible cause. Detailed chart reviews of the electronic health records within the Mayo Clinic and outside medical records were performed. RESULTS: A total of 883 patients who underwent LVAD implantation were included in our study. ES occurred in 7% (n = 61) of patients with a median of 13 days (interquartile range [IQR]: 5-297 days) following surgery. We found 57% of patients (n = 35) developed ES within 30 days, while 43% (n = 26) patients developed ES at a median of 545  (IQR 152-1032) days after surgery. Following ES, 26% of patients died within 1 year. Patients with ES had a significant association with a history of ventricular arrhythmias and implantable cardioverter defibrillator (ICD) shocks before the procedure. ES was significantly associated with reduced survival compared to patients without ES (hazards ratio [HR]: 1.92, 95% CI: 1.39-2.64, p < .001). CONCLUSION: Following LVAD implantation, the rate of ES was 7% with majority of ES occurring within 30 days of LVAD. Risk factors for ES included pre-implant history of ventricular arrhythmias and ICD shock. ES was significantly associated with reduced survival compared to patients without ES.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Implantação de Prótese , Taquicardia Ventricular , Função Ventricular Esquerda , Humanos , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Idoso , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Medição de Risco , Potenciais de Ação , Frequência Cardíaca , Adulto
6.
Heart Rhythm O2 ; 5(3): 150-157, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560374

RESUMO

Background: The outcomes of left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) in patients with heart failure remain to be learned. Objective: The objective of this study was to assess the echocardiographic and clinical outcomes of LBBP, LVSP, and deep septal pacing (DSP). Methods: This retrospective study included patients who met the criteria for cardiac resynchronization therapy (CRT) and underwent attempted LBBP in 5 Mayo centers. Clinical, electrocardiographic, and echocardiographic data were collected at baseline and follow-up. Results: A total of 91 consecutive patients were included in the study. A total of 52 patients had LBBP, 25 had LVSP, and 14 had DSP. The median follow-up duration was 307 (interquartile range 208, 508) days. There was significant left ventricular ejection fraction (LVEF) improvement in the LBBP and LVSP groups (from 35.9 ± 8.5% to 46.9 ± 10.0%, P < .001 in the LBBP group; from 33.1 ± 7.5% to 41.8 ± 10.8%, P < .001 in the LVSP group) but not in the DSP group. A unipolar paced right bundle branch block morphology during the procedure in lead V1 was associated with higher odds of CRT response. There was no significant difference in heart failure hospitalization and all-cause deaths between the LBBP and LVSP groups. The rate of heart failure hospitalization and all-cause deaths were increased in the DSP group compared with the LBBP group (hazard ratio 5.10, 95% confidence interval 1.14-22.78, P = .033; and hazard ratio 7.83, 95% confidence interval 1.38-44.32, P = .020, respectively). Conclusion: In patients undergoing CRT, LVSP had comparable CRT outcomes compared with LBBP.

7.
Heart Rhythm ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38588996

RESUMO

BACKGROUND: The 2014 Heart Rhythm Society consensus statement defines histological (definite) and clinical (probable) diagnostic categories of cardiac sarcoidosis (CS), but few studies have compared their arrhythmic phenotypes and outcomes. OBJECTIVE: The purpose of this study was to evaluate the electrophysiological/arrhythmic phenotype and outcomes of patients with definite and probable CS. METHODS: We analyzed the arrhythmic/electrophysiological phenotype in a single-center North American cohort of 388 patients (median age 56 years; 39% female, n = 151) diagnosed with definite (n = 58) or probable (n = 330) CS (2000-2022). The primary composite outcome was survival to first ventricular tachycardia/fibrillation (VT/VF) event or sudden cardiac death. Key secondary outcomes were also assessed. RESULTS: At index evaluation, in situ cardiac implantable electronic devices and antiarrhythmic drug use were more common in definite CS. At a median follow-up of 3.1 years, the primary outcome occurred in 22 patients with definite CS (38%) and 127 patients with probable CS (38%) (log-rank, P = .55). In multivariable analysis, only a higher ratio of the 18F-fluorodeoxyglucose maximum standardized uptake value of the myocardium to the maximum standardized uptake value of the blood pool (hazard ratio 1.09; 95% confidence interval 1.03-1.15; P = .003, per 1 unit increase) was associated with the primary outcome. During follow-up, patients with definite CS had a higher burden of device-treated VT/VF events (mean 2.86 events per patient-year vs 1.56 events per patient-year) and a higher rate of progression to heart transplant/left ventricular assist device implantation but no difference in all-cause mortality compared with patients with probable CS. CONCLUSION: Patients with definite and probable CS had similarly high risks of first sustained VT/VF/sudden cardiac death and all-cause mortality, though patients with definite CS had a higher overall arrhythmia burden. Both CS diagnostic groups as defined by the 2014 Heart Rhythm Society criteria require an aggressive approach to prevent arrhythmic complications.

8.
Eur Heart J Digit Health ; 5(2): 192-194, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38505482

RESUMO

Aims: ECG abnormalities are often the first signs of arrhythmogenic right ventricular cardiomyopathy (ARVC) and we hypothesized that an artificial intelligence (AI)-enhanced ECG could help identify patients with ARVC and serve as a valuable disease-detection tool. Methods and results: We created a convolutional neural network to detect ARVC using a 12-lead ECG. All patients with ARVC who met the 2010 task force criteria and had disease-causative genetic variants were included. All case ECGs were randomly assigned in an 8:1:1 ratio into training, validation, and testing groups. The case ECGs were age- and sex-matched with control ECGs at our institution in a 1:100 ratio. Seventy-seven patients (51% male; mean age 47.2 ± 19.9), including 56 patients with PKP2, 7 with DSG2, 6 with DSC2, 6 with DSP, and 2 with JUP were included. The model was trained using 61 case ECGs and 5009 control ECGs; validated with 7 case ECGs and 678 control ECGs and tested in 22 case ECGs and 1256 control ECGs. The sensitivity, specificity, positive and negative predictive values of the model were 77.3, 62.9, 3.32, and 99.4%, respectively. The area under the curve for rhythm ECG and median beat ECG was 0.75 and 0.76, respectively. Conclusion: Our study found that the model performed well in excluding ARVC and supports the concept that the AI ECG can serve as a biomarker for ARVC if a larger cohort were available for network training. A multicentre study including patients with ARVC from other centres would be the next step in refining, testing, and validating this algorithm.

11.
Heart Rhythm ; 21(7): 1024-1031, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38365125

RESUMO

BACKGROUND: The hemodynamic effects of transcatheter left atrial appendage occlusion (LAAO) remain unclear. OBJECTIVE: We sought to assess the effect of LAAO on invasive hemodynamics and their correlation with clinical outcomes. METHODS: We recorded mean left atrial pressure (mLAP) before and after device deployment. We assessed the prevalence and predictors of mLAP increase after deployment, the association between significant mLAP increase after deployment and 45-day peridevice leak (PDL), and the association between mLAP increase and heart failure (HF) hospitalization. A significant mLAP increase was defined as one equal to or greater than the mean percentage increase in mLAP after deployment (≥28%). RESULTS: We included 302 patients (36.4% female; mean age, 75.8 ± 9.5 years). After deployment, mLAP increased in 48% of patients, 38% of whom experienced significant mLAP increase. Independent predictors of mLAP increase were baseline mLAP ≤14 mm Hg, nonparoxysmal atrial fibrillation, and age per 5 years (odds ratios: 3.66 [95% CI, 2.21-6.05], 1.81 [95% CI, 1.08-3.02], and 0.85 [95% CI, 0.73-0.99], respectively). Significant mLAP increase was an independent predictor of 45-day PDL (odds ratio, 2.55; 95% CI, 1.04-6.26). There was no association between mLAP increase and HF hospitalization. CONCLUSION: After deployment, mLAP acutely rises in 48% of patients, although this is not associated with increased HF hospitalizations. PDL is more likely to develop at 45 days in patients with significant increase in mLAP after deployment, although most leaks were small (<5 mm). These findings suggest that mLAP increase after deployment is not associated with major safety concerns. Additional studies are warranted to explore the long-term hemodynamic effects of LAAO.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Pressão Atrial , Cateterismo Cardíaco , Hemodinâmica , Humanos , Feminino , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Masculino , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/métodos , Pressão Atrial/fisiologia , Hemodinâmica/fisiologia , Dispositivo para Oclusão Septal , Estudos Retrospectivos , Função do Átrio Esquerdo/fisiologia , Seguimentos , Ecocardiografia Transesofagiana
12.
Circ Arrhythm Electrophysiol ; 17(2): e012377, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38288627

RESUMO

BACKGROUND: The incidence and prognosis of right bundle branch block (RBBB) following transcatheter aortic valve replacement (TAVR) are unknown. Hence, we sought to characterize the incidence of post-TAVR RBBB and determine associated risks of permanent pacemaker (PPM) implantation and mortality. METHODS: All patients 18 years and above without preexisting RBBB or PPM who underwent TAVR at US Mayo Clinic sites and Mayo Clinic Health Systems from June 2010 to May 2021 were evaluated. Post-TAVR RBBB was defined as new-onset RBBB in the postimplantation period. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. RESULTS: Of 1992 patients, 15 (0.75%) experienced new RBBB post-TAVR. There was a higher degree of valve oversizing among patients with new RBBB post-TAVR versus those without (17.9% versus 10.0%; P=0.034). Ten patients (66.7%) with post-TAVR RBBB experienced high-grade atrioventricular block and underwent PPM implantation (median 1 day; Q1, 0.2 and Q3, 4), compared with 268/1977 (13.6%) without RBBB. Following propensity score adjustment for covariates (age, sex, balloon-expandable valve, annulus diameter, and valve oversizing), post-TAVR RBBB was significantly associated with PPM implantation (hazard ratio, 8.36 [95% CI, 4.19-16.7]; P<0.001). No statistically significant increase in mortality was seen with post-TAVR RBBB (hazard ratio, 0.83 [95% CI, 0.33-2.11]; P=0.69), adjusting for age and sex. CONCLUSIONS: Although infrequent, post-TAVR RBBB was associated with elevated PPM implantation risk. The mechanisms for its development and its clinical prognosis require further study.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Estenose da Valva Aórtica/cirurgia , Incidência , Estimulação Cardíaca Artificial/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/cirurgia
13.
JACC Clin Electrophysiol ; 10(1): 68-78, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897465

RESUMO

BACKGROUND: Injury to the esophagus has been reported in a high percentage of patients undergoing ablation of atrial fibrillation (AF). OBJECTIVES: This study assessed the incidence of esophageal injury in patients undergoing ablation of AF with and without an esophageal deviating device. METHODS: This prospective, randomized, multicenter, double-blinded, controlled Food and Drug Administration investigational device exemption trial compared the incidence of ablation-related esophageal lesions, as assessed by endoscopy, in patients undergoing AF ablation assigned to a control group (luminal esophageal temperature [LET] monitoring alone) compared with patients randomized to a deviation group (esophagus deviation device + LET). This novel deviating device uses vacuum suction and mechanical deflection to deviate a segment of the esophagus, including the trailing edge. RESULTS: The data safety and monitoring board recommended stopping the study early after randomizing 120 patients due to deviating device efficacy. The primary study endpoint, ablation injury to the esophageal mucosa, was significantly less in the deviation group (5.7%) in comparison to the control group (35.4%; P < 0.0001). Control patients had a significantly higher severity and greater number of ablation lesions per patient. There was no adverse event assigned to the device. By multivariable analysis, the only feature associated with reduced esophageal lesions was randomization to deviating device (OR: 0.13; 95% CI: 0.04-0.46; P = 0.001). Among control subjects, there was no difference in esophageal lesions with high power/short duration (31.8%) vs other radiofrequency techniques (37.2%; P = 0.79). CONCLUSIONS: The use of an esophageal deviating device resulted in a significant reduction in ablation-related esophageal lesions without any adverse events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Humanos , Estudos Prospectivos , Ablação por Cateter/métodos , Esôfago/cirurgia
15.
Artigo em Inglês | MEDLINE | ID: mdl-37715077

RESUMO

BACKGROUND: We recently demonstrated that patients with atrial fibrillation (AF) and hypertrophic cardiomyopathy (HCM) have an increased risk of left atrial (LA) thrombus. In this study, we aimed to evaluate thrombus management, thrombus persistence, and thromboembolic events for HCM and non-HCM patients with AF and LA thrombus. METHODS: From a cohort of 2,155 AF patients undergoing transesophageal echocardiography (TEE) for any indication, this study included 122 patients with LA thrombus (64 HCM patients and 58 non-HCM controls). RESULTS: There was no difference in mean CHA2DS2-VASc scores between HCM and control patients (3.9 ± 2.2 vs 3.8 ± 2.0, p = 0.88). Ten (16%) and 4 (7%) patients in the HCM and control groups, respectively, were in sinus rhythm at the time of TEE identifying the LA thrombus (p = 0.13). In all patients, the anticoagulation strategy was modified after the LA thrombus diagnosis. A total of 36 (56%) HCM patients and 34 (59%) control patients had follow-up TEE at median 90 and 62 days, respectively, after index TEE. The HCM group had significantly higher 90-day rates of persistent LA thrombus compared to the control group (88% vs 29%; p < 0.001). In adjusted models, HCM was independently associated with LA thrombus persistence. Among patients with LA thrombus, the 5-year cumulative incidence of thromboembolic events was 11% and 2% in HCM and control groups, respectively (p = 0.22). CONCLUSIONS: Among patients with AF with LA thrombus identified by TEE, those with HCM appear to have a higher risk of LA thrombus persistence than non-HCM patients despite anticoagulation.

16.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37595138

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). There is limited data regarding the outcomes of AF catheter ablation in HCM patients. In this study, we aimed to synthesize all available evidence on the effectiveness of ablation of AF in patients with HCM compared to those without HCM. METHODS AND RESULTS: We systematically reviewed bibliographic databases to identify studies published through February 2023. We included cohort studies with available quantitative information on rates of recurrent atrial arrhythmias, anti-arrhythmic drug (AAD) therapy, and repeat ablation procedures after initial AF ablation in patients with vs without HCM. Estimates were combined using random-effects meta-analysis models and reported as risk ratios (RR) and 95% confidence intervals (CI). Eight studies were included in quantitative synthesis (262 HCM and 642 non-HCM patients). During median follow-up 13-54 months across studies, AF recurrence rates ranged from 13.3% to 92.9% in HCM and 7.6% to 58.8% in non-HCM patients. The pooled RR for recurrent atrial arrhythmia after the first AF ablation in HCM patients compared to non-HCM controls was 1.498 (95% CI = 1.305-1.720; P < 0.001). During follow-up, HCM patients more often required AAD therapy (RR = 2.844; 95% CI = 1.713-4.856; P < 0.001) and repeat AF ablation (RR = 1.544; 95% CI = 1.070-2.228; P = 0.02). The pooled RR for recurrent atrial arrhythmias after the last AF ablation was higher in patients with HCM than those without HCM (RR = 1.607; 95% CI = 1.235-2.090; P < 0.001). CONCLUSIONS: Compared to non-HCM patients, those with HCM had higher rates of recurrent atrial arrhythmias, AAD use, and need for repeat AF ablation after initial ablation of AF.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Cardiomiopatia Hipertrófica , Fármacos Cardiovasculares , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/efeitos adversos
17.
JACC Cardiovasc Interv ; 16(8): 885-895, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37100552

RESUMO

An increasing number of patients with mitral valve disease are high risk for surgery and in need of less invasive treatments including transcatheter mitral valve replacement (TMVR). Left ventricular outflow tract (LVOT) obstruction is a predictor of poor outcome after TMVR, and its risk can be accurately predicted using cardiac computed tomography analysis. Novel treatment strategies that have shown efficacy in reducing risk of LVOT obstruction after TMVR include pre-emptive alcohol septal ablation, radiofrequency ablation, and anterior leaflet electrosurgical laceration. This review describes recent advances in the management of LVOT obstruction risk after TMVR, provides a new management algorithm, and explores forthcoming studies that will further advance the field.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Resultado do Tratamento
18.
Heart Rhythm ; 20(8): 1111-1118, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37075957

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) safety in patients with an epicardial cardiac implantable electronic device (CIED) is uncertain. OBJECTIVE: The purpose of this study was to assess the safety and adverse effects of MRI in patients who had surgically implanted epicardial CIED. METHODS: Patients with surgically implanted CIEDs who underwent MRI with an appropriate cardiology-radiology collaborative protocol between January 2008 and January 2021 were prospectively studied in 2 clinical centers. All patients underwent close cardiac monitoring through MRI procedures. Outcomes were compared between the epicardial CIED group and the matched non-MRI-conditional transvenous CIED group. RESULTS: Twenty-nine consecutive patients with epicardial CIED (41.4% male; mean age 43 years) underwent 52 MRIs in 57 anatomic regions. Sixteen patients had a pacemaker, 9 had a cardiac defibrillator or cardiac resynchronization therapy-defibrillator, and 4 had no device generator. No significant adverse events occurred in the epicardial or transvenous CIED groups. Battery life, pacing, sensing thresholds, lead impedance, and cardiac biomarkers were not significantly changed, except 1 patient had a transient decrease in atrial lead sensing function. CONCLUSION: MRI of CIEDs with epicardially implanted leads does not represent a greater risk than transvenous CIEDs when performed with a multidisciplinary collaborative protocol centered on patient safety.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Adulto , Feminino , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Coração , Segurança do Paciente
19.
J Cardiovasc Electrophysiol ; 34(5): 1206-1215, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36994918

RESUMO

INTRODUCTION: Data regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation in patients with aortic valve (AV) intervention (AVI) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of prosthetic valves. We sought to investigate the characteristics, safety, and outcomes of CA in patients with prior AVI and ventricular arrhythmias (VA). METHODS: We identified consecutive patients with prior AVI (replacement or repair) who underwent CA for VT or PVC between 2013 and 2018. We investigated the mechanism of arrhythmia, ablation approach, perioperative complications, and outcomes. RESULTS: We included 34 patients (88% men, mean age 64 ± 10.4 years, left ventricular (LV) ejection fraction 35.2 ± 15.0%) with prior AVI who underwent CA (22 VT; 12 PVC). LV access was obtained through trans-septal approach in all patients except one patient who had percutaneous transapical access. One patient had combined retrograde aortic and trans-septal approach. Scar-related reentry was the dominant mechanism of induced VTs. Two patients had bundle branch reentry VTs. In the VT group, substrate mapping demonstrated heterogeneous scar that involved the peri-AV area in 95%. Despite that, the site of successful ablation included the periaortic region only in 6 (27%) patients. In the PVC group, signal abnormalities consistent with scar in the periaortic area were noted in 4 (33%) patients. In 8 (67%) patients, the successful site of ablation was unrelated to the periaortic area. No procedure-related complications occurred. The survival and recurrence-free survival rate at 1 year tended to be lower in VT group than in PVC group (p = .06 and p = .05, respectively) with a 1-year recurrence-free survival rate of 52.8% and 91.7%, respectively. No arrhythmia-related death was documented on long-term follow-up. CONCLUSION: CA of VAs can be performed safely and effectively in patients with prior AVI.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Cicatriz/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Sistema de Condução Cardíaco , Ablação por Cateter/efeitos adversos
20.
World J Pediatr Congenit Heart Surg ; 14(4): 474-480, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36972504

RESUMO

BACKGROUND: Left (LAAA) and right atrial appendage aneurysms (RAAA) are rare entities, and their natural history, management, and long-term outcomes are not well studied. METHODS: This retrospective review includes all patients from 2000 to 2021 with atrial appendage aneurysms at our institution identified using an electronic search tool. LAAA and RAAA were confirmed using multimodality imaging and intraoperative findings. RESULTS: We identified 13 (87%) patients with LAAA and 2 (13%) with RAAA. At diagnosis, 11 (73%) were female, mean age was 51.4 ± 18.8 years, and ejection fraction 56.5 ± 13.1%. Three (20%) patients had congenital heart disease including 2 (13%) with atrioventricular septal defects and 1 (7%) with congenitally corrected transposition. LAAA/RAAA was diagnosed due to new-onset atrial fibrillation (AF) in 6 (40%) patients and embolic stroke in 2 (13%). Ten patients had preexisting AF diagnosed 2.9 ± 1.4 years earlier at a mean age of 50.2 ± 15.5 years. Thrombus within the aneurysm was identified in 2 (15%) LAAA patients. All patients were on anticoagulation and follow-up of the cohort from diagnosis was 7.1 ± 6.2 years. Eleven (73%) patients were surgically managed with 7 (64%) lesions excised, 1 (9%) stapled, and 3 (27%) ligated. Postoperative complications occurred in 2 (18%) patients with 1 (7%) developing tricuspid regurgitation and another with pericardial effusion and tamponade. CONCLUSIONS: Atrial appendage aneurysm is a rare disease and nearly half of patients present with AF. Surgical treatment with concomitant AF ablation is a reasonable and safe management option.


Assuntos
Apêndice Atrial , Aneurisma Cardíaco , Cardiopatias Congênitas , Acidente Vascular Cerebral , Trombose , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/cirurgia , Cardiopatias Congênitas/complicações , Complicações Pós-Operatórias/diagnóstico , Resultado do Tratamento , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...