Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Scand J Surg ; 95(3): 195-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17066617

RESUMO

BACKGROUND AND AIMS: The purpose of this study was to evaluate the efficacy of high-resolution axillary ultrasound (AU) in detecting the rate of recurrence after a negative sentinel node (SN) biopsy in patients with breast cancer and without additional axillary dissection. MATERIALS AND METHODS: The operating oncologic surgeon performed 196 consequent sentinel node biopsies during surgery of breast cancer. The sentinel nodes were identified by using preoperative lymphoscintigraphy, intraoperative gamma probe and Patent Blue dye. A routine postoperative follow-up of the patients were performed every 3rd month including clinical examinations, blood chemistry and mammography. After 31 months (range 14-49 months), a high-resolution AU was performed for 107 patients with a negative sentinel node during surgery and without axillary dissection, to visualize any abnormal lymph nodes in the axilla. If necessary, large core biopsies were undertaken to obtain histology of abnormal axillary nodes. RESULTS: The SNs were visualized during preoperative lymphoscintigraphy in 167/196 (85%) and found during the surgery in 163/167 (98%) of patients. The mean number of removed SN were 1.7+/-0.8. The SN metastasis were found in 29% (56/196) of patients. During the follow-up, abnormal nodes were identified during AU in only 4/107 patients. Core biopsies confirmed benign histology in three patients and one case of lymphoma was detected. CONCLUSIONS: There were no axillary recurrences of breast cancer after a negative SN biopsy during the 2.6 year follow-up. Axillary ultrasound is a useful tool in the quality control of patients with negative SN biopsy and without diagnostic axillary dissection.


Assuntos
Neoplasias da Mama/patologia , Linfonodos/diagnóstico por imagem , Mastectomia , Garantia da Qualidade dos Cuidados de Saúde , Biópsia de Linfonodo Sentinela/métodos , Biópsia de Linfonodo Sentinela/normas , Axila , Neoplasias da Mama/cirurgia , Feminino , Humanos , Período Intraoperatório , Linfonodos/patologia , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Ultrassonografia
2.
Clin Exp Rheumatol ; 24(3): 247-52, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16870090

RESUMO

OBJECTIVE: To examine a contrast medium method using a glucocorticoid-air-saline mixture and ultrasound imaging (GAS-graphy) for the verification of palpation-guided injections in different joints and to assess the inter-reader reliability of the method. METHODS: A palpation-guided injection of an air-steroid-saline mixture was given into a joint or tendon sheath of 133 consecutive patients. The dynamic ultrasound monitor images of the joints and tendons involved were videotaped before and after the injection. A rheumatologist and two radiologists analyzed separately the video clips of each patient, under blinded conditions. The readers evaluated the accuracy of the injections and the difficulty of the reading process. The inter-reader agreement was assessed by calculating the percentual values and overall kappa coefficient between the readers. RESULTS: The overall accuracy of the successful injections was 76%, 80% and 82 % evaluated by the three readers. In six out of the ten injection sites the accuracy was higher than 80%. The clarity of the method evaluated by the readers was 8, 8 and 8.5 on a scale from 0 to 10. The inter-reader agreement assessed by percentual values was 84.2%, 85.0% and 88.7%. The kappa coefficient between all readers was 0.595 showing moderate agreement. CONCLUSION: The GAS-graphy method for the verification of palpation-guided injections is a simple procedure performable to any joint site and the result can be seen immediately on the monitor after the injection. The reliability of the method is good and it can be used in developing injection techniques as well as in medical or nurse education. The method can be used as an alternative for the radiographic contrast medium method in verifying successful palpation-guided intra-articular injections.


Assuntos
Ar , Meios de Contraste , Glucocorticoides , Injeções Intra-Articulares/métodos , Palpação/métodos , Reumatologia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite/diagnóstico por imagem , Artrite/tratamento farmacológico , Feminino , Glucocorticoides/uso terapêutico , Humanos , Articulações/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...