Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Trials ; 24(1): 621, 2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37777787

RESUMO

BACKGROUND: Well-organised and managed workplaces can be a source of wellbeing. The construction, healthcare and information and communication technology sectors are characterised by work-related stressors (e.g. high workloads, tight deadlines) which are associated with poorer mental health and wellbeing. The MENTUPP intervention is a flexibly delivered, multi-level approach to supporting small- and medium-sized enterprises (SMEs) in creating mentally healthy workplaces. The online intervention is tailored to each sector and designed to support employees and leaders dealing with mental health difficulties (e.g. stress), clinical level anxiety and depression, and combatting mental health-related stigma. This paper presents the protocol for the cluster randomised controlled trial (cRCT) of the MENTUPP intervention in eight European countries and Australia. METHODS: Each intervention country will aim to recruit at least two SMEs in each of the three sectors. The design of the cRCT is based on the experiences of a pilot study and guided by a Theory of Change process that describes how the intervention is assumed to work. SMEs will be randomly assigned to the intervention or control conditions. The aim of the cRCT is to assess whether the MENTUPP intervention is effective in improving mental health and wellbeing (primary outcome) and reducing stigma, depression and suicidal behaviour (secondary outcome) in employees. The study will also involve a process and economic evaluation. CONCLUSIONS: At present, there is no known multi-level, tailored, flexible and accessible workplace-based intervention for the prevention of non-clinical and clinical symptoms of depression, anxiety and burnout, and the promotion of mental wellbeing. The results of this study will provide a comprehensive overview of the implementation and effectiveness of such an intervention in a variety of contexts, languages and cultures leading to the overall goal of delivering an evidence-based intervention for mental health in the workplace. TRIAL REGISTRATION: Please refer to Item 2a and registration ISRCTN14104664. Registered on 12th July 2022.


Assuntos
Transtornos Mentais , Local de Trabalho , Humanos , Projetos Piloto , Local de Trabalho/psicologia , Saúde Mental , Promoção da Saúde , Ensaios Clínicos Controlados Aleatórios como Assunto , Literatura de Revisão como Assunto
2.
Artigo em Inglês | MEDLINE | ID: mdl-26415129

RESUMO

Intravascular ultrasound (IVUS) provides radiation-free, real-time imaging and assessment of atherosclerotic disease in terms of anatomical, functional, and molecular composition. The primary clinical applications of IVUS imaging include assessment of luminal plaque volume and real-time image guidance for stent placement. When paired with microbubble contrast agents, IVUS technology may be extended to provide nonlinear imaging, molecular imaging, and therapeutic delivery modes. In this review, we discuss the development of emerging imaging and therapeutic applications that are enabled by the combination of IVUS imaging technology and microbubble contrast agents.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Microbolhas , Ultrassonografia de Intervenção/métodos , Animais , Artérias Carótidas/diagnóstico por imagem , Humanos , Coelhos , Suínos
3.
Photoacoustics ; 3(2): 55-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26236641

RESUMO

We have developed reflection-mode multispectral photoacoustic microscopy (PAM) based on a novel optical-acoustic objective that integrates a customized ultrasonic transducer and a commercial reflective microscope objective into one solid piece. This technical innovation provides zero chromatic aberration and convenient confocal alignment of the optical excitation and acoustic detection. With a wavelength-tunable optical-parametric-oscillator laser, we have demonstrated multispectral PAM over an ultrabroad spectral range of 270-1300 nm. A near-constant lateral resolution of ∼2.8 µm is achieved experimentally. Capitalizing on the consistent performance over the ultraviolet, visible, and near-infrared range, multispectral PAM enables label-free concurrent imaging of cell nucleus (DNA/RNA contrast at 270 nm), blood vessel (hemoglobin contrast at 532 nm), and sebaceous gland (lipid contrast at 1260 nm) at the same spatial scale in a living mouse ear.

4.
Ann Biomed Eng ; 43(11): 2642-51, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25893508

RESUMO

Potent therapeutic compounds with dose dependent side effects require more efficient and selective drug delivery to reduce systemic drug doses. Here, we demonstrate a new platform that combines intravascular ultrasound (IVUS) and drug-loaded microbubbles to enhance and localize drug delivery, while enabling versatility of drug type and dosing. Localization and degree of delivery with IVUS and microbubbles was assessed using fluorophore-loaded microbubbles and different IVUS parameters in ex vivo swine arteries. Using a swine model of neointimal hyperplasia, reduction of neointima formation following balloon injury was evaluated when using the combination of IVUS and sirolimus-loaded microbubbles. IVUS and microbubble enhanced fluorophore delivery was greatest when applying low amplitude pulses in the ex vivo model. In the in vivo model, neointima formation was reduced by 50% after treatment with IVUS and the sirolimus-loaded microbubbles. This reduction was achieved with a sirolimus whole blood concentration comparable to a commercial drug-eluting stent (0.999 ng/mL). We anticipate this therapy will find clinical use localizing drug delivery for numerous other diseases in addition to serving as an adjunct to stents in treating atherosclerosis.


Assuntos
Sistemas de Liberação de Medicamentos , Imunossupressores/administração & dosagem , Microbolhas , Neointima/tratamento farmacológico , Sirolimo/administração & dosagem , Angioplastia Coronária com Balão/efeitos adversos , Animais , Vasos Coronários/patologia , Imunossupressores/sangue , Imunossupressores/farmacocinética , Neointima/patologia , Sirolimo/sangue , Sirolimo/farmacocinética , Suínos , Ultrassonografia de Intervenção
5.
Ultrasound Med Biol ; 40(10): 2458-67, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25130449

RESUMO

An intravascular ultrasound (IVUS) and microbubble drug delivery system was evaluated in both ex vivo and in vivo swine vessel models. Microbubbles with the fluorophore DiI embedded in the shell as a model drug were infused into ex vivo swine arteries at a physiologic flow rate (105 mL/min) while a 5-MHz IVUS transducer applied ultrasound. Ultrasound pulse sequences consisted of acoustic radiation force pulses to displace DiI-loaded microbubbles from the vessel lumen to the wall, followed by higher-intensity delivery pulses to release DiI into the vessel wall. Insonation with both the acoustic radiation force pulse and the delivery pulse increased DiI deposition 10-fold compared with deposition with the delivery pulse alone. Localized delivery of DiI was then demonstrated in an in vivo swine model. The theoretical transducer beam width predicted the measured angular extent of delivery to within 11%. These results indicate that low-frequency IVUS catheters are a viable method for achieving localized drug delivery with microbubbles.


Assuntos
Vasos Coronários/diagnóstico por imagem , Sistemas de Liberação de Medicamentos , Técnicas de Imagem por Elasticidade/instrumentação , Microbolhas , Ultrassonografia de Intervenção/instrumentação , Animais , Bovinos , Vasos Coronários/lesões , Microscopia de Fluorescência , Suínos , Transdutores
6.
Artigo em Inglês | MEDLINE | ID: mdl-24569249

RESUMO

There is interest in examining the potential of modified intravascular ultrasound (IVUS) catheters to facilitate dual diagnostic and therapeutic roles using ultrasound plus microbubbles for localized drug delivery to the vessel wall. The goal of this study was to design, prototype, and validate an IVUS transducer for microbubble-based drug delivery. A 1-D acoustic radiation force model and finite element analysis guided the design of a 1.5-MHz IVUS transducer. Using the IVUS transducer, biotinylated microbubbles were displaced in water and bovine whole blood to the streptavidin-coated wall of a flow phantom by a 1.5-MHz center frequency, peak negative pressure = 70 kPa pulse with varying pulse repetition frequency (PRF) while monitoring microbubble adhesion with ultrasound. A fit was applied to the RF data to extract a time constant (τ). As PRF was increased in water, the time constant decreased (τ = 32.6 s, 1 kHz vs. τ = 8.2 s, 6 kHz), whereas in bovine whole blood an adhesion-no adhesion transition was found for PRFs ≥ 8 kHz. Finally, a fluorophore was delivered to an ex vivo swine artery using microbubbles and the IVUS transducer, resulting in a 6.6-fold increase in fluorescence. These results indicate the importance of PRF (or duty factor) for IVUS acoustic radiation force microbubble displacement and the potential for IVUS and microbubbles to provide localized drug delivery.


Assuntos
Cápsulas/química , Cápsulas/efeitos da radiação , Preparações de Ação Retardada/efeitos da radiação , Microbolhas/uso terapêutico , Sonicação/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Preparações de Ação Retardada/administração & dosagem , Desenho de Equipamento , Análise de Falha de Equipamento
7.
Artigo em Inglês | MEDLINE | ID: mdl-23143566

RESUMO

Previous research has demonstrated that acoustic radiation force enhances intravascular microbubble adhesion to blood vessels in the presence of flow for moleculartargeted ultrasound imaging and drug delivery. A prototype acoustic radiation force intravascular ultrasound (ARFIVUS) catheter was designed and fabricated to displace a microbubble contrast agent in flow representative of conditions encountered in the human carotid artery. The prototype ARFIVUS transducer was designed to match the resonance frequency of 1.4- to 2.6-µm-diameter microbubbles modeled by an experimentally verified 1-D microbubble acoustic radiation force translation model. The transducer element was an elongated Navy Type I (hard) lead zirconate titanate (PZT) ceramic designed to operate at 3 MHz. Fabricated devices operated with center frequencies of 3.3 and 3.6 MHz with -6-dB fractional bandwidths of 55% and 50%, respectively. Microbubble translation velocities as high as 0.86 m/s were measured using a high-speed streak camera when insonating with the ARFIVUS transducer. Finally, the prototype was used to displace microbubbles in a flow phantom while imaging with a commercial 45-MHz imaging IVUS transducer. A sustained increase of 31 dB in average video intensity was measured following insonation with the ARFIVUS, indicating microbubble accumulation resulting from the application of acoustic radiation force.


Assuntos
Catéteres , Sistemas de Liberação de Medicamentos/instrumentação , Microbolhas , Ultrassonografia de Intervenção/instrumentação , Artérias Carótidas/diagnóstico por imagem , Meios de Contraste/química , Meios de Contraste/farmacocinética , Sistemas de Liberação de Medicamentos/métodos , Análise de Elementos Finitos , Humanos , Modelos Cardiovasculares , Imagens de Fantasmas , Transdutores , Ultrassonografia de Intervenção/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-23443711

RESUMO

A selectable, dual-frequency, capacitive micro- machined ultrasonic transducer (CMUT) designed for both high-frequency imaging and low-frequency therapeutic effect is presented. A validated finite element analysis (FEA) CMUT model was used to examine the performance of the proposed dual-frequency transducer. CMUT device simulations were used to design a hybrid device incorporating stand-off structures that divide a large, low-frequency membrane into smaller, high-frequency sub-membranes when the membrane is partially collapsed so that the stand-offs contact the substrate. In low-frequency operation, simulations indicated that the peak negative pressure achieved by the hybrid device, when biased by 30.0 VDC and excited by a 2-MHz signal with 30.0 V amplitude, exceeded 190 kPa, which is sufficient for microbubble rupture. Low-frequency mode bandwidth was 93% at a center frequency of 2.1 MHz. In the high-frequency mode of operation, the device was excited by 175 Vdc and 87.5 Vac, which generated a peak negative pressure of 247 kPa. Device center frequency was 44.1 MHz with a - 6-dB fractional bandwidth of 42%.


Assuntos
Desenho Assistido por Computador , Membranas Artificiais , Modelos Teóricos , Transdutores , Terapia por Ultrassom/instrumentação , Simulação por Computador , Capacitância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Elementos Finitos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...