Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 88(1): 292-308, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35344611

RESUMO

PURPOSE: Rapid acquisition scheme and parameter estimation method are proposed to acquire distortion-free spin- and stimulated-echo signals and combine the signals with a physics-driven unsupervised network to estimate T1 , T2 , and proton density (M0 ) parameter maps, along with B0 and B1 information from the acquired signals. THEORY AND METHODS: An imaging sequence with three 90° RF pulses is utilized to acquire spin- and stimulated-echo signals. We utilize blip-up/-down acquisition to eliminate geometric distortion incurred by the effects of B0 inhomogeneity on rapid EPI acquisitions. For multislice imaging, echo-shifting is applied to utilize dead time between the second and third RF pulses to encode information from additional slice positions. To estimate parameter maps from the spin- and stimulated-echo signals with high fidelity, 2 estimation methods, analytic fitting and a novel unsupervised deep neural network method, are developed. RESULTS: The proposed acquisition provided distortion-free T1 , T2 , relative proton density (M0), B0 , and B1 maps with high fidelity both in phantom and in vivo brain experiments. From the rapidly acquired spin- and stimulated-echo signals, analytic fitting and the network-based method were able to estimate T1 , T2 , M0 , B0 , and B1 maps with high accuracy. Network estimates demonstrated noise robustness owing to the fact that the convolutional layers take information into account from spatially adjacent voxels. CONCLUSION: The proposed acquisition/reconstruction technique enabled whole-brain acquisition of coregistered, distortion-free, T1 , T2 , M0 , B0 , and B1 maps at 1 × 1 × 5 mm3 resolution in 50 s. The proposed unsupervised neural network provided noise-robust parameter estimates from this rapid acquisition.


Assuntos
Imagem Ecoplanar , Prótons , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Imagens de Fantasmas
2.
NMR Biomed ; 35(5): e4662, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34939236

RESUMO

Magnetization transfer contrast MR fingerprinting (MTC-MRF) is a novel quantitative imaging method that simultaneously quantifies free bulk water and semisolid macromolecule parameters using pseudo-randomized scan parameters. To improve acquisition efficiency and reconstruction accuracy, the optimization of MRF sequence design has been of recent interest in the MRF field, but has been challenging due to the large number of degrees of freedom to be optimized in the sequence. Herein, we propose a framework for learning-based optimization of the acquisition schedule (LOAS), which optimizes RF saturation-encoded MRF acquisitions with a minimal number of scan parameters for tissue parameter determination. In a supervised learning framework, scan parameters were subsequently updated to minimize a predefined loss function that can directly represent tissue quantification errors. We evaluated the performance of the proposed approach with a numerical phantom and in in vivo experiments. For validation, MRF images were synthesized using the tissue parameters estimated from a fully connected neural network framework and compared with references. Our results showed that LOAS outperformed existing indirect optimization methods with regard to quantification accuracy and acquisition efficiency. The proposed LOAS method could be a powerful optimization tool in the design of MRF pulse sequences.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Imagens de Fantasmas
3.
Med Phys ; 48(11): 7346-7359, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34628653

RESUMO

PURPOSE: Anomaly detection in magnetic resonance imaging (MRI) is to distinguish the relevant biomarkers of diseases from those of normal tissues. In this paper, an unsupervised algorithm is proposed for pixel-level anomaly detection in multicontrast MRI. METHODS: A deep neural network is developed, which uses only normal MR images as training data. The network has the two stages of feature generation and density estimation. For feature generation, relevant features are extracted from multicontrast MR images by performing contrast translation and dimension reduction. For density estimation, the distributions of the extracted features are estimated by using Gaussian mixture model (GMM). The two processes are trained to estimate normative distributions well presenting large normal datasets. In test phases, the proposed method can detect anomalies by measuring log-likelihood that a test sample belongs to the estimated normative distributions. RESULTS: The proposed method and its variants were applied to detect glioblastoma and ischemic stroke lesion. Comparison studies with six previous anomaly detection algorithms demonstrated that the proposed method achieved relevant improvements in quantitative and qualitative evaluations. Ablation studies by removing each module from the proposed framework validated the effectiveness of each proposed module. CONCLUSION: The proposed deep learning framework is an effective tool to detect anomalies in multicontrast MRI. The unsupervised approaches would have great potentials in detecting various lesions where annotated lesion data collection is limited.


Assuntos
Imageamento por Ressonância Magnética , Acidente Vascular Cerebral , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Distribuição Normal
4.
Magn Reson Med ; 86(2): 1077-1092, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33720462

RESUMO

PURPOSE: A motion-correction network for multi-contrast brain MRI is proposed to correct in-plane rigid motion artifacts in brain MR images using deep learning. METHOD: The proposed method consists of 2 parts: image alignment and motion correction. Alignment of multi-contrast MR images is performed in an unsupervised manner by a CNN work, yielding transformation parameters to align input images in order to minimize the normalized cross-correlation loss among multi-contrast images. Then, fine-tuning for image alignment is performed by maximizing the normalized mutual information. The motion correction network corrects motion artifacts in the aligned multi-contrast images. The correction network is trained to minimize the structural similarity loss and the VGG loss in a supervised manner. All datasets of motion-corrupted images are generated using motion simulation based on MR physics. RESULTS: A motion-correction network for multi-contrast brain MRI successfully corrected artifacts of simulated motion for 4 test subjects, showing 0.96%, 7.63%, and 5.03% increases in the average structural simularity and 5.19%, 10.2%, and 7.48% increases in the average normalized mutual information for T1 -weighted, T2 -weighted, and T2 -weighted fluid-attenuated inversion recovery images, respectively. The experimental setting with image alignment and artifact-free input images for other contrasts shows better performances in correction of simulated motion artifacts. Furthermore, the proposed method quantitatively outperforms recent deep learning motion correction and synthesis methods. Real motion experiments from 5 healthy subjects demonstrate the potential of the proposed method for use in a clinical environment. CONCLUSION: A deep learning-based motion correction method for multi-contrast MRI was successfully developed, and experimental results demonstrate the validity of the proposed method.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Neuroimagem
5.
Magn Reson Med ; 86(1): 230-244, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33594783

RESUMO

PURPOSE: To develop a framework for quantifying intravoxel incoherent motion (IVIM) parameters, where a neural network for quantification and b-values for diffusion-weighted imaging are simultaneously optimized. METHOD: A deep neural network (DNN) method is proposed for accurate quantification of IVIM parameters from multiple diffusion-weighted images. In addition, optimal b-values are selected to acquire the multiple diffusion-weighted images. The proposed framework consists of an MRI signal generation part and an IVIM parameter quantification part. Monte-Carlo (MC) simulations were performed to evaluate the accuracy of the IVIM parameter quantification and the efficacy of b-value optimization. In order to analyze the effect of noise on the optimized b-values, simulations were performed with five different noise levels. For in vivo data, diffusion images were acquired with the b-values from four b-values selection methods for five healthy volunteers at 3T MRI system. RESULTS: Experiment results showed that both the optimization of b-values and the training of DNN were simultaneously performed to quantify IVIM parameters. We found that the accuracies of the perfusion coefficient (Dp ) and perfusion fraction (f) were more sensitive to b-values than the diffusion coefficient (D) was. Furthermore, when the noise level changed, the optimized b-values also changed. Therefore, noise level has to be considered when optimizing b-values for IVIM quantification. CONCLUSION: The proposed scheme can simultaneously optimize b-values and train DNN to minimize quantification errors of IVIM parameters. The trained DNN can quantify IVIM parameters from the diffusion-weighted images obtained with the optimized b-values.


Assuntos
Imagem de Difusão por Ressonância Magnética , Redes Neurais de Computação , Voluntários Saudáveis , Humanos , Movimento (Física) , Perfusão
6.
Med Phys ; 48(5): 2185-2198, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33405244

RESUMO

PURPOSE: Medical image analysis using deep neural networks has been actively studied. For accurate training of deep neural networks, the learning data should be sufficient and have good quality and generalized characteristics. However, in medical images, it is difficult to acquire sufficient patient data because of the difficulty of patient recruitment, the burden of annotation of lesions by experts, and the invasion of patients' privacy. In comparison, the medical images of healthy volunteers can be easily acquired. To resolve this data bias problem, the proposed method synthesizes brain tumor images from normal brain images. METHODS: Our method can synthesize a huge number of brain tumor multicontrast MR images from numerous healthy brain multicontrast MR images and various concentric circles. Because tumors have complex characteristics, the proposed method simplifies them into concentric circles that are easily controllable. Then, it converts the concentric circles into various realistic tumor masks through deep neural networks. The tumor masks are used to synthesize realistic brain tumor images from normal brain images. RESULTS: We performed a qualitative and quantitative analysis to assess the usefulness of augmented data from the proposed method. Data augmentation by the proposed method provided significant improvements to tumor segmentation compared with other GAN-based methods. Intuitive experimental results are available online at https://github.com/KSH0660/BrainTumor. CONCLUSIONS: The proposed method can control the grade tumor masks by the concentric circles, and synthesize realistic brain tumor multicontrast MR images. In terms of data augmentation, the proposed method can successfully synthesize brain tumor images that can be used to train tumor segmentation networks or other deep neural networks.


Assuntos
Neoplasias Encefálicas , Processamento de Imagem Assistida por Computador , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Redes Neurais de Computação
7.
Magn Reson Med ; 85(4): 2040-2054, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33128483

RESUMO

PURPOSE: To develop a fast, quantitative 3D magnetization transfer contrast (MTC) framework based on an unsupervised learning scheme, which will provide baseline reference signals for CEST and nuclear Overhauser enhancement imaging. METHODS: Pseudo-randomized RF saturation parameters and relaxation delay times were applied in an MR fingerprinting framework to generate transient-state signal evolutions for different MTC parameters. Prospectively compressed sensing-accelerated (four-fold) MR fingerprinting images were acquired from 6 healthy volunteers at 3 T. A convolutional neural network framework in an unsupervised fashion was designed to solve an inverse problem of a two-pool MTC Bloch equation, and was compared with a conventional Bloch equation-based fitting approach. The MTC images synthesized by the convolutional neural network architecture were used for amide proton transfer and nuclear Overhauser enhancement imaging as a reference baseline image. RESULTS: The fully unsupervised learning scheme incorporated with the two-pool exchange model learned a set of unique features that can describe the MTC-MR fingerprinting input, and allowed only small amounts of unlabeled data for training. The MTC parameter values estimated by the unsupervised learning method were in excellent agreement with values estimated by the conventional Bloch fitting approach, but dramatically reduced computation time by ~1000-fold. CONCLUSION: Given the considerable time efficiency compared to conventional Bloch fitting, unsupervised learning-based MTC-MR fingerprinting could be a powerful tool for quantitative MTC and CEST/nuclear Overhauser enhancement imaging.


Assuntos
Encéfalo , Aprendizado de Máquina não Supervisionado , Amidas , Humanos , Imageamento por Ressonância Magnética , Prótons
8.
Neuroimage ; 221: 117165, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32679254

RESUMO

Semisolid magnetization transfer contrast (MTC) and chemical exchange saturation transfer (CEST) MRI based on MT phenomenon have shown potential to evaluate brain development, neurological, psychiatric, and neurodegenerative diseases. However, a qualitative MT ratio (MTR) metric commonly used in conventional MTC imaging is limited in the assessment of quantitative semisolid macromolecular proton exchange rates and concentrations. In addition, CEST signals measured by MTR asymmetry analysis are unavoidably contaminated by upfield nuclear Overhauser enhancement (NOE) signals of mobile and semisolid macromolecules. To address these issues, we developed an MTC-MR fingerprinting (MTC-MRF) technique to quantify tissue parameters, which further allows an estimation of accurate MTC signals at a certain CEST frequency offset. A pseudorandomized RF saturation scheme was used to generate unique MTC signal evolutions for different tissues and a supervised deep neural network was designed to extract tissue properties from measured MTC-MRF signals. Through detailed Bloch equation-based digital phantom and in vivo studies, we demonstrated that the MTC-MRF can quantify MTC characteristics with high accuracy and computational efficiency, compared to a conventional Bloch equation fitting approach, and provide baseline reference signals for CEST and NOE imaging. For validation, MTC-MRF images were synthesized using the tissue parameters estimated from the deep-learning method and compared with experimentally acquired MTC-MRF images as the reference standard. The proposed MTC-MRF framework can provide quantitative 3D MTC, CEST, and NOE imaging of the human brain within a clinically acceptable scan time.


Assuntos
Encéfalo/diagnóstico por imagem , Aprendizado Profundo , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Aprendizado de Máquina Supervisionado , Humanos
9.
Magn Reson Med ; 83(1): 124-138, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31403219

RESUMO

PURPOSE: A new unsupervised learning method was developed to correct metal artifacts in MRI using 2 distorted images obtained with dual-polarity readout gradients. METHODS: An unsupervised learning method is proposed for a deep neural network architecture consisting of a deep neural network and an MR image generation module. The architecture is trained as an end-to-end process without the use of distortion-free images or off-resonance frequency maps. The deep neural network estimates frequency-shift maps between 2 distorted images that are obtained using dual-polarity readout gradients. From the estimated frequency-shift maps and 2 distorted input images, distortion-corrected images are obtained with the MR image generation module. Experiments using synthetic data and actual MR data were performed to compare images corrected by several metal-artifact-correction methods. RESULTS: The proposed method resolved the ripple and pile-up artifacts in the reconstructed images from synthetic data and actual MR data. The results from the proposed method were comparable to those from supervised-learning methods and superior to the compared model-based method. The proposed unsupervised learning method enabled the network to be trained without labels and to be more robust than supervised learning methods, for which overfitting problems can arise when using small training data sets. CONCLUSION: Metal artifacts in the MR image were drastically corrected by the proposed unsupervised learning method. Two distorted images obtained with dual-polarity readout gradients are used as the input of the deep neural network. The proposed method can train networks without labels and does not overfit the network, even with small training data sets.


Assuntos
Artefatos , Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Metais/química , Aprendizado de Máquina não Supervisionado , Algoritmos , Humanos , Modelos Estatísticos , Redes Neurais de Computação , Imagens de Fantasmas , Reprodutibilidade dos Testes
10.
Magn Reson Med ; 81(6): 3616-3627, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30693969

RESUMO

PURPOSE: To optimize a steady-state imaging sequence for maximizing the amide proton transfer effects in pulsed-CEST (pCEST) imaging. METHOD: The steady-state pCEST (SS-pCEST) sequence is a fast CEST imaging scheme that applies repetitive short RF pulses for generating CEST and acquiring MR imaging signal alternately. To maximize the obtainable amide proton transfer effects, the SS-pCEST scheme is analyzed and optimized with respect to not only the imaging parameters but also the imaging schemes of the signal acquisition part. Three imaging parameters such as the flip angle and RF power for saturation and the flip angle for imaging are selected as factors affecting the obtainable CEST effects; and 2 imaging schemes, namely, SSFP and spoiled gradient echo sequences, are analyzed and compared for numerical simulations and MRI experiments at 3 tesla. RESULTS: SS-pCEST combined with SSFP could provide higher amide proton transfer effects than that with spoiled gradient echo. Furthermore, in the proposed SS-pCEST imaging with SSFP, 3 imaging parameters can be independently optimized so that the optimization complexities can be reduced. CONCLUSION: We optimized the SS-pCEST imaging method with SSFP to maximize the amide proton transfer effects. In addition, our analysis showed the SSFP sequence was more efficient than the spoiled gradient echo sequence for SS-pCEST imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Simulação por Computador , Feminino , Humanos , Masculino , Imagens de Fantasmas , Prótons , Adulto Jovem
11.
NMR Biomed ; 31(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29266452

RESUMO

A simultaneous acquisition technique of image and navigator signals (simultaneously acquired navigator, SIMNAV) is proposed for cardiac magnetic resonance imaging (CMRI) in Cartesian coordinates. To simultaneously acquire both image and navigator signals, a conventional balanced steady-state free precession (bSSFP) pulse sequence is modified by adding a radiofrequency (RF) pulse, which excites a supplementary slice for the navigator signal. Alternating phases of the RF pulses make it easy to separate the simultaneously acquired magnetic resonance data into image and navigator signals. The navigator signals of the proposed SIMNAV were compared with those of current gating devices and self-gating techniques for seven healthy subjects. In vivo experiments demonstrated that SIMNAV could provide cardiac cine images with sufficient image quality, similar to those from electrocardiogram (ECG) gating with breath-hold. SIMNAV can be used to acquire a cardiac cine image without requiring an ECG device and breath-hold, whilst maintaining feasible imaging time efficiency.


Assuntos
Imagem Cinética por Ressonância Magnética , Movimento (Física) , Adulto , Eletrocardiografia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Respiração , Processamento de Sinais Assistido por Computador
12.
Artigo em Inglês | MEDLINE | ID: mdl-16422418

RESUMO

Up to the present time, the analysis and design of ultrasonic motors (USMs) have been performed using rough analytic methods or commercial analysis tools without considering the complex contact mechanisms. As a result, it was impossible to achieve an exact analysis and design of a USM. In order to address the problem, we proposed the analysis and design methodology of an L1B4 USM using a three-dimensional finite element method combined with an analytic method that considers complex contact mechanisms in linear operation. This methodology is applicable to many other kinds of USMs which use resonance modes and contact mechanisms. Also, we designed and prototyped the mechanical system and driving circuit of the L1B4 USM, and finally validated the proposed analysis and design methodology by comparing their outcomes with experimental data.


Assuntos
Eletroquímica/instrumentação , Eletrodos , Transdutores , Ultrassonografia/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Modelos Teóricos , Movimento (Física) , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...