Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heart Vessels ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38953938

RESUMO

Iliac artery angioplasty with stenting is an effective alternative treatment modality for aortoiliac occlusive diseases. Few randomized controlled trials have compared the efficacy and safety between self-expandable stent (SES) and balloon-expandable stent (BES) in atherosclerotic iliac artery disease. In this randomized, multicenter study, patients with common or external iliac artery occlusive disease were randomly assigned in a 1:1 ratio to either BES or SES. The primary end point was the 1-year clinical patency, defined as freedom from any surgical or percutaneous intervention due to restenosis of the target lesion after the index procedure. The secondary end point was a composite event from major adverse clinical events at 1 year. A total of 201 patients were enrolled from 17 major cardiovascular intervention centers in South Korea. The mean age of the enrolled patients was 66.8 ± 8.5 years and 86.2% of the participants were male. The frequency of critical limb ischemia was 15.4%, and the most common target lesion was in the common iliac artery (75.1%). As the primary end point, the 1-year clinical patency as primary end point was 99% in the BES group and 99% in the SES group (p > 0.99). The rate of repeat revascularization at 1 year was 7.8% in the BES group and 7.0% in the SES group (p = 0.985; confidence interval, 1.011 [0.341-2.995]). In our randomized study, the treatment of iliac artery occlusive disease with self-expandable versus balloon-expandable stent was comparable in 12-month clinical outcomes without differences in the procedural success or geographic miss rate regardless of the deployment method in the distal aortoiliac occlusive lesion (ClinicalTrials.gov, NCT01834495).

2.
JACC Cardiovasc Interv ; 17(3): 329-340, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38355261

RESUMO

BACKGROUND: Distal radial access (DRA) as an alternative access route lacks evidence, despite its recent reputation. OBJECTIVES: The aim of this study was to evaluate the safety and feasibility of DRA on the basis of daily practice. METHODS: The KODRA (Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach) trial was a prospective multicenter registry conducted at 14 hospitals between September 2019 and September 2021. The primary endpoints were the success rates of coronary angiography (CAG) and percutaneous coronary intervention (PCI). The secondary endpoints included successful distal radial artery puncture, access-site crossover, access site-related complications, bleeding events, and predictors of puncture failure. RESULTS: A total of 4,977 among 5,712 screened patients were recruited after the exclusion of 735 patients. The primary endpoints, the success rates of CAG and PCI via DRA, were 100% and 98.8%, respectively, among successful punctures of the distal radial artery (94.4%). Access-site crossover occurred in 333 patients (6.7%). The rates of distal radial artery occlusion and radial artery occlusion by palpation were 0.8% (36 of 4,340) and 0.8% (33 of 4,340) at 1-month follow-up. DRA-related bleeding events were observed in 3.3% of patients, without serious hematoma. Multilevel logistic regression analysis identified weak pulse (OR: 9.994; 95% CI: 7.252-13.774) and DRA experience <100 cases (OR: 2.187; 95% CI: 1.383-3.456) as predictors of puncture failure. CONCLUSIONS: In this large-scale prospective multicenter registry, DRA demonstrated high success rates of CAG and PCI, with a high rate of puncture success but low rates of distal radial artery occlusion, radial artery occlusion, bleeding events, and procedure-related complications. Weak pulse and DRA experience <100 cases were predictors of puncture failure. (Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach [KODRA]; NCT04080700).


Assuntos
Arteriopatias Oclusivas , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Artéria Radial/diagnóstico por imagem , Angiografia Coronária/métodos , Hemorragia/etiologia , Arteriopatias Oclusivas/complicações , Sistema de Registros
3.
Korean Circ J ; 49(8): 709-720, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31165595

RESUMO

BACKGROUND AND OBJECTIVES: Diffuse long coronary artery disease (DLCAD) still has unfavorable clinical outcomes after successful percutaneous coronary intervention (PCI). Therefore, we aimed to evaluate the effectiveness and safety of Resolute™ zotarolimus-eluting stent (R-ZES; Resolute™ Integrity) for patients with DLCAD. METHODS: From December 2011 to December 2014, 1,011 patients who underwent PCI using R-ZES for CAD with longer than 25 mm lesion were prospectively enrolled from 21 hospitals in Korea. We assessed the clinical outcome of major adverse cardiac events (MACE) defined as the composite of cardiac death, non-fatal myocardial infarction (MI), and clinically-driven target vessel revascularization at 12 months. RESULTS: Mean age was 63.8±10.8 years, 701 (69.3%) patients were male, 572 (87.0%) patients had hypertension, 339 (33.8%) patients had diabetes, 549 (54.3%) patients diagnosed with acute MI and 545 (53.9%) patients had multi-vessel disease (MVD). A total of 1,697 stents were implanted into a total of 1,472 lesions. The mean diameter was 3.07±0.38 mm and the length was 28.27±6.97 mm. Multiple overlapping stents were performed in 205 (13.8%) lesions. A 12-month clinical follow-up was available in 1,004 patients (99.3%). The incidences of MACE and definite stent thrombosis at 12-month were 3.0% and 0.3% respectively. On multivariate Cox-regression analysis, multiple overlapping stents implantation, previous congestive heart failure, MVD, and age ≥75 years were independent predictors of one-year MACE. CONCLUSIONS: Our study shows that R-ZES has an excellent 1-year clinical outcome in Korean patients with DLCAD.

4.
Trials ; 17(1): 302, 2016 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-27344435

RESUMO

BACKGROUND: The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. METHODS/DESIGN: The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. DISCUSSION: The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. TRIAL REGISTRATION: National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.


Assuntos
Ligas , Angioplastia com Balão/instrumentação , Ligas de Cromo , Artéria Ilíaca , Doença Arterial Periférica/terapia , Stents Metálicos Autoexpansíveis , Stents , Angioplastia com Balão/efeitos adversos , Protocolos Clínicos , Constrição Patológica , Elasticidade , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , República da Coreia , Projetos de Pesquisa , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
Catheter Cardiovasc Interv ; 81(6): E250-4, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22639463

RESUMO

The Outback LTD re-entry catheter system has become a valuable tool for peripheral intervention and it has been widely used for variable peripheral chronic total occlusion (CTO). However, its use in the setting of the aorta was restricted because of concerns of bleeding risks resulting from re-entry puncture or ballooning. This report presents a case of successful re-entry using the Outback LTD Re-Entry Catheter (Cordis, Bridgewater, New Jersy) at the aorta in a patient with bilateral common iliac artery occlusion.


Assuntos
Angioplastia com Balão , Aorta , Arteriopatias Oclusivas/terapia , Cateterismo Periférico/instrumentação , Artéria Ilíaca , Dispositivos de Acesso Vascular , Idoso , Aortografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Desenho de Equipamento , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino , Punções , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Korean Circ J ; 41(6): 327-30, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21779286

RESUMO

Intravascular ultrasonography (IVUS) imaging is a user-friendly technique widely used during coronary interventions. An 80-year-old man was admitted with chest pain, and successful percutaneous coronary intervention was performed with stent implantation. One week later, the patient complained of further chest pain. Urgent coronary angiography showed total occlusion of the middle left anterior descending artery and the aspiration of thrombi was high. IVUS imaging showed inadequate stent strut apposition and distal dissection. We attempted another stent implantation but the IVUS catheter was stuck on the 0.014 inch wire. Therefore, we tried to pass the wire across the lateral side. After the wire was successfully passaged, the sprinter balloon was passed through the crushed stent to expand it. After 4 days later, the patient was discharged with no symptoms or electrocardiographic change.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...