Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Pediatr Otorhinolaryngol ; 79(1): 42-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25468461

RESUMO

OBJECTIVE: Numerous studies have shown the superiority of a 1000-Hz frequency probe tone for evaluating the middle ear status of infants. However, most of these studies examined Caucasian populations. This study validated the 1000-Hz probe tone and evaluated the age at which it should be used in Korean infants. METHODS: Data from 83 infants (43 males, 40 females; mean age 9.2±6.2 (range 1-30) months, 165 ears) were analyzed. Tympanograms were classified according to Baldwin's modification of the method of Marchant et al. and correlated with results based on combined diagnostic tests, including an endoscopic examination of the tympanic membrane, myringotomy findings, and the air and bone conduction auditory brainstem response (ABR) thresholds. Data were analyzed in five age groups, each covering a 3-month range. The traces were measured for both 226- and 1000-Hz probe tones. The sensitivity and specificity for the different age groups were also determined. RESULTS: For the 226-Hz probe tone, the tympanograms showed normal traces for most ears with otitis media effusions in infants younger than 12 months. By contrast, the tympanograms using the 1000-Hz probe tone showed abnormal traces in most of the infants with otitis media effusions in all age groups. In infants with no otitis media effusion, the tympanograms using both 226- and 1000-Hz probe tones were interpreted as normal in most cases in all age groups. In infants younger than 12 months, the sensitivity of the 226-Hz probe tone was very low (0-6.6%), whereas that of the 1000-Hz probe tone was very high (90-100%). In infants older than 13 months, however, the sensitivities of the 226- and 1000-Hz probe tones were 76.2% and 85.7%, respectively. Regarding specificity, the difference between the two probe tones was not significant for any age group. CONCLUSIONS: This study confirmed the superiority of the 1000-Hz probe tone for evaluating the middle ear in infants. We recommend using a 1000-Hz probe tone at least up to the age of 12 months for Korean infants.


Assuntos
Testes de Impedância Acústica/métodos , Povo Asiático , Otite Média com Derrame/diagnóstico , Testes de Impedância Acústica/instrumentação , Condução Óssea , Pré-Escolar , Potenciais Evocados Auditivos do Tronco Encefálico , Feminino , Humanos , Lactente , Masculino , República da Coreia , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Neuropsychiatr Dis Treat ; 9: 989-94, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23986638

RESUMO

BACKGROUND: Antipsychotic-induced subjective inner restlessness is one of the common and distressing adverse effects associated with antipsychotics; however, its underlying neurobiological basis is not well understood. We examined the relationship between antipsychotic-induced subjective inner restlessness and autonomic neurocardiac function. METHODS: Twenty-two schizophrenia patients with antipsychotic-induced subjective restlessness, 28 schizophrenia patients without antipsychotic-induced subjective restlessness, and 28 matched healthy control subjects were evaluated. Assessments of the linear and nonlinear complexity measures of heart rate dynamics were performed. Multivariate analysis of variance and correlation analysis were conducted. RESULTS: The mean interbeat (RR) interval value was significantly higher in control subjects than in patients with and without antipsychotic-induced subjective restlessness (P < 0.05). The low frequency/high frequency ratio was significantly higher in patients with antipsychotic-induced subjective restlessness than in control subjects and in patients without antipsychotic-induced subjective restlessness (P < 0.05), while the approximate entropy value was significantly lower in patients with antipsychotic-induced subjective restlessness than in control subjects and in patients without antipsychotic-induced subjective restlessness (P < 0.05). Correlation analyses controlling for psychotic symptom severity showed that the degree of antipsychotic-induced restlessness had a significant negative correlation with the value of approximate entropy (P < 0.05). CONCLUSION: The results indicate that antipsychotic-induced subjective restlessness is associated with altered heart rate dynamics parameters, particularly the nonlinear complexity measure, suggesting that it might adversely affect autonomic neurocardiac integrity. Further prospective research is necessary to elucidate the precise interrelationships and causality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...