Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Neurophysiol ; 139: 1-8, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35489208

RESUMO

OBJECTIVE: To measure the neuromagnetic fields of carpal tunnel syndrome patients after electrical digital nerve stimulation and evaluate median nerve function with high spatial resolution. METHODS: A superconducting quantum interference device magnetometer system was used to record neuromagnetic fields at the carpal tunnel after electrical stimulation of the middle digital nerve in 10 hands of nine patients with carpal tunnel syndrome. The patients were diagnosed based on symptoms (numbness, tingling, and pain) supported by a positive Phalen or Tinel sign. A novel technique was applied to remove stimulus-induced artifacts, and current distributions were calculated using a spatial filter algorithm and superimposed on X-ray. RESULTS: In 6 of the 10 hands, the amplitude of the inward current waveform attenuated to <70% or the nerve conduction velocity was <40 m/s. The results of conventional nerve conduction studies were normal for two of these six hands. All four hands that could not be diagnosed by magnetoneurography had severe carpal tunnel syndrome superimposed on peripheral neuropathy secondary to comorbidities. CONCLUSIONS: Technical improvements enabled magnetoneurography to noninvasively visualize the electrophysiological nerve activity in carpal tunnel syndrome patients. SIGNIFICANCE: Magnetoneurography may have the potential to contribute to the detailed diagnosis of various peripheral nerve disorders.


Assuntos
Síndrome do Túnel Carpal , Doenças do Sistema Nervoso Periférico , Síndrome do Túnel Carpal/diagnóstico , Humanos , Nervo Mediano , Condução Nervosa/fisiologia , Punho
2.
Clin Neurophysiol ; 133: 39-47, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34800837

RESUMO

OBJECTIVE: Noninvasive and detailed visualization of electrophysiological activity in the thoracic spinal cord through magnetoneurography. METHODS: In five healthy volunteers, magnetic fields around current flowing in the thoracic spinal cord after alternating unilateral and synchronized bilateral sciatic nerve stimulation were measured using a magnetoneurograph system with superconductive quantum interference device biomagnetometers. The current distribution was obtained from the magnetic data by spatial filtering and visualized by superimposing it on the X-ray image. Conduction velocity was calculated using the peak latency of the current waveforms. RESULTS: A sufficiently high magnetic signal intensity and signal-to-noise ratio were obtained in all participants after synchronized bilateral sciatic nerve stimulation. Leading and trailing components along the spinal canal and inward components flowing into the depolarization site ascended to the upper thoracic spine. Conduction velocity of the inward current in the whole thoracic spine was 42.4 m/s. CONCLUSIONS: Visualization of electrophysiological activity in the thoracic spinal cord was achieved through magnetoneurography and a new method for synchronized bilateral sciatic nerve stimulation. Magnetoneurography is expected to be a useful modality in functional assessment of thoracic myelopathy. SIGNIFICANCE: This is the first report to use magnetoneurography to noninvasively visualize electrophysiological activity in the thoracic spinal cord in detail.


Assuntos
Condução Nervosa/fisiologia , Medula Espinal/fisiologia , Adulto , Estimulação Elétrica , Voluntários Saudáveis , Humanos , Campos Magnéticos , Masculino , Pessoa de Meia-Idade , Vértebras Torácicas
3.
Clin Neurophysiol ; 131(10): 2460-2468, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32861157

RESUMO

OBJECTIVE: To establish a method for magnetospinography (MSG) measurement after ulnar nerve stimulation and to clarify its characteristics. METHODS: Using a 132-channel magnetoneurography system with a superconducting quantum interference device, cervical MSG measurements were obtained for 10 healthy volunteers after stimulation of the ulnar nerve at the elbow and the wrist, and neural current distribution was calculated and superimposed on the cervical X-ray images. RESULTS: Neuromagnetic signals were obtained in all participants after applying the stimulus artifact removal algorithm. The measured magnetic field intensity after elbow stimulation was about twice that after wrist stimulation. Calculated neural currents flowed into the intervertebral foramina at C6/7 to T1/2 and propagated cranially along the spinal canal. The conduction velocity from the peak latency of inward currents at C5-C7 was 73.4 ± 19.6 m/s. CONCLUSIONS: We successfully obtained MSG measurements after ulnar nerve stimulation. The neural currents flowed into the spinal canal from more caudal segments after ulnar nerve stimulation compared with median nerve stimulation, and these MSG measurements were effective in examining the spinal tracts at C5/6/7. SIGNIFICANCE: This is the first report on the use of MSG to visualize electrical activity in the cervical spinal cord and nerve root after ulnar nerve stimulation.


Assuntos
Medula Cervical/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Condução Nervosa/fisiologia , Nervo Ulnar/fisiologia , Adulto , Medula Cervical/diagnóstico por imagem , Estimulação Elétrica , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
4.
Clin Neurophysiol ; 131(4): 951-957, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31866341

RESUMO

OBJECTIVE: To establish a noninvasive method to measure the neuromagnetic fields of the median nerve at the carpal tunnel after electrical digital nerve stimulation and evaluate peripheral nerve function. METHODS: Using a vector-type biomagnetometer system with a superconducting quantum interference device, neuromagnetic fields at the carpal tunnel were recorded after electrical stimulation of the index or middle digital nerve in five healthy volunteers. A novel technique for removing stimulus-induced artifacts was applied, and current distributions were calculated using a spatial filter algorithm and superimposed on X-ray. RESULTS: A neuromagnetic field propagating from the palm to the carpal tunnel was observed in all participants. Current distributions estimated from the magnetic fields had five components: leading and trailing components parallel to the conduction pathway, outward current preceding the leading component, inward currents between the leading and trailing components, and outward current following the trailing component. The conduction velocity and peak latency of the inward current agreed well with those of sensory nerve action potentials. CONCLUSION: Removing stimulus-induced artifacts enabled magnetoneurography to noninvasively visualize with high spatial resolution the electrophysiological neural activity from the palm to the carpal tunnel. SIGNIFICANCE: This is the first report of using magnetoneurography to visualize electrophysiological nerve activity at the palm and carpal tunnel.


Assuntos
Potenciais de Ação/fisiologia , Síndrome do Túnel Carpal/fisiopatologia , Nervo Mediano/fisiopatologia , Condução Nervosa/fisiologia , Adulto , Estimulação Elétrica , Feminino , Mãos/inervação , Humanos , Campos Magnéticos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...