Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Acta Radiol ; 59(9): 1029-1037, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29235879

RESUMO

Background Rapid injection of gadoxetic acid is reported to produce more frequent artifacts and lower vascular enhancement on arterial phase liver magnetic resonance imaging (MRI). However, its effect on tumor enhancement and the mechanism of the artifacts remain unclear. Purpose To evaluate the effect of rapid injection of gadoxetic acid on artifacts and tumor enhancement during arterial phase liver MRI, and on arterial blood gases (ABGs) which may explain the cause of the artifacts. Material and Methods ABG analysis was performed in 13 free-breathing rabbits after rapid injection (1 mL/s; injection time = 0.6-0.8 s) of gadoxetic acid (0.025 mmol/kg). Dynamic liver MRI was performed in six anesthetized rabbits with VX2 tumors under a ventilation stoppage after rapid and slow injection (0.25 mL/s; injection time = 2.4-3.2 s) of gadoxetic acid. Artifacts and signal enhancement on arterial phase imaging were compared with those obtained after rapid injection of gadopentetic acid (Gd-DTPA, 0.1 mmol/kg) using a Friedman test or Kruskal-Wallis test. Results ABG analysis did not find any significant changes. Artifacts were not related to injection protocols ( P = 0.95). Aortic enhancement with slow injection of gadoxetic acid was significantly higher than that with rapid injection ( P < 0.05), and was comparable to that with Gd-DTPA injection. Tumor enhancement obtained with gadoxetic acid was not significantly different between rapid and slow injection, and was significantly lower than that with Gd-DTPA injection ( P < 0.05). Conclusion Rapid injection of gadoxetic acid did not affect ABGs and may not be the cause of the artifacts. It lowered vascular enhancement but not arterial tumor enhancement.


Assuntos
Artefatos , Meios de Contraste/farmacologia , Gadolínio DTPA/farmacologia , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Animais , Gasometria , Meios de Contraste/administração & dosagem , Gadolínio DTPA/administração & dosagem , Coelhos
2.
Liver Cancer ; 6(4): 349-359, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29234638

RESUMO

BACKGROUND: We prospectively compared the efficacy of gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) with that of dynamic multidetector computed tomography (MDCT) for detection of recurrent hypervascular hepatocellular carcinoma (HCC) after radiofrequency ablation (RFA). METHODS: Institutional review board approval and written informed consent were obtained for this multicenter study. Ninety-seven HCC patients treated with curative RFA underwent both Gd-EOB-DTPA-enhanced MRI and dynamic MDCT every 3-4 months. HCC diagnosis was made based on the typical enhancement pattern of HCC on MRI and/or CT by on-site consensus reading. Two blinded observers independently assessed image datasets to compare diagnostic accuracy, sensitivity, specificity, and the areas under the receiver operating characteristic curve (AUROC). RESULTS: Recurrence was observed in 48 of 97 patients. Among these, 22 were diagnosed by both Gd-EOB-DTPA-enhanced MRI and MDCT; the remainder were diagnosed by only one of these 2 modalities. Recurrence was diagnosed in more patients by Gd-EOB-DTPA-enhanced MRI than by MDCT (44 vs. 26 patients, p < 0.001). Patient-based analysis revealed that the accuracy, sensitivity, and AUROC of Gd-EOB-DTPA-enhanced MRI were significantly higher than those of MDCT for both observers (p < 0.005). The AUROC of Gd-EOB-DTPA- enhanced MRI and MDCT was 0.95 and 0.76 for observer 1 and 0.90 and 0.74 for observer 2, respectively. The κ values for MRI and MDCT were 0.83 and 0.70, respectively. CONCLUSIONS: Compared with dynamic MDCT, Gd-EOB-DTPA-enhanced MRI had higher diagnostic accuracy and sensitivity for detection of recurrent hypervascular HCC and may be a better tool for following patients after RFA.

3.
Jpn J Radiol ; 34(8): 548-55, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27271279

RESUMO

PURPOSE: We investigated the effects of patient- and image acquisition-related factors on the image quality in coronary CT angiography (CCTA). MATERIALS AND METHODS: We enrolled 1197 patients (728 men; 65 ± 12 years). All underwent CCTA under the routine scan protocol in 23 participating hospitals. The subjective image quality (3-point Likert scale: excellent, good, and poor) and the attenuation of the left and right coronary artery (LCA, RCA) were recorded; the effects of patient and image acquisition-related factors on vascular attenuation were then compared. RESULTS: The mean LCA attenuation was 515.2 ± 65.8 (excellent), 401.4 ± 63.4 (good), and 319.5 ± 47.6 HU (poor). The corresponding RCA attenuation was 496.6 ± 67.6, 390.5 ± 58.5, and 308.5 ± 50.7 HU, respectively. Univariate analysis revealed significant associations between sufficient coronary attenuation (> 400 HU) and the age, gender, body surface area (BSA), number of detectors, contrast synchronization, scan mode, and the fractional contrast dose. Multivariate analysis revealed that the bolus tracking method, prospective electrocardiogram gating, and fractional contrast dose were significantly associated with sufficient coronary enhancement. CONCLUSION: BSA and fractional contrast dose are the most important patient- and image acquisition-related factors for sufficient coronary attenuation in CCTA.


Assuntos
Tamanho Corporal , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Superfície Corporal , Vasos Coronários/diagnóstico por imagem , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
4.
Magn Reson Imaging ; 34(4): 545-51, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26747408

RESUMO

PURPOSE: To prospectively evaluate the efficacy of a new three-dimensional gradient-echo sequence (Turbo LAVA) that uses undersampled k-space acquisition combined with a two-dimensional parallel imaging technique for hepatobiliary MRI. MATERIALS AND METHODS: Sixty patients underwent T1-weighted gadoxetic acid-enhanced hepatobiliary axial MRI during a single breath-hold using both Turbo LAVA (thickness/interval=1.6/0.8mm) and conventional three-dimensional gradient-echo (4/2mm; LAVA) sequences at 3T. Axial 4-mm-thick reformation was performed from Turbo LAVA images. Portal vein-to-liver contrast (PLC), bile duct-to-liver contrast (BLC), and lesion-to-liver contrast (LLC) were compared. Two radiologists independently assessed image quality using a five-point scale. Sagittal 4-mm-thick multiplanar reconstructions (MPR) were performed from both sequences and assessed together with directly obtained 4-mm-thick sagittal LAVA images in terms of sharpness. The paired t-test was used to compare PLC, BLC, and LLC. The Wilcoxon signed rank test was used to compare five-point scales. RESULTS: The mean PLC (P<0.001), BLC (P<0.001), and LLC (P<0.005) were significantly higher for Turbo LAVA than for LAVA; the scores for image noise and sharpness were inferior (P=0.000 and 0.005) and superior (0.005 and 0.157) for Turbo LAVA. There were no significant differences in the scores for bile duct visualization, artifacts, fat suppression quality, overall quality, and focal lesion conspicuity. For sagittal images, MPR Turbo LAVA showed significantly better sharpness than MPR LAVA but showed significantly worse sharpness compared with directly obtained LAVA. CONCLUSION: High-spatial-resolution single-breath-hold hepatobiliary MRI using Turbo LAVA was feasible. Diagnostic-quality MPR images can be obtained using this sequence.


Assuntos
Ductos Biliares/diagnóstico por imagem , Gadolínio DTPA/química , Aumento da Imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Suspensão da Respiração , Meios de Contraste/química , Feminino , Humanos , Imageamento Tridimensional , Hepatopatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Radiology ; 278(3): 773-81, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26356063

RESUMO

PURPOSE: To identify the body size parameter that exhibits the best correlation with aortic and hepatic enhancement at hepatic dynamic computed tomography (CT) in a large patient population enrolled in a multicenter study. MATERIALS AND METHODS: This prospective study was approved by the ethics committee of each of the 31 participating institutions where 1342 patients were enrolled between April 2012 and September 2013. All patients provided either written or oral informed consent. All patients underwent hepatic dynamic CT, which included preenhanced, hepatic arterial phase (HAP), and portal venous phase (PVP) scanning, performed with the routine scanning protocol of each institution. Changes in CT number (in Hounsfield units) per gram of iodine in the aorta (eA/I) and liver (eL/I) during HAP and PVP scanning were recorded for each patient. Hierarchical multivariate linear regression analysis was performed in which the outcome variable was either eA/I or eL/I; the independent variables were age, sex, one body size parameter (height, body weight, body mass index, lean body weight [LBW], or body surface area), and liver function (aspartate aminotransferase, albumin, and total bilirubin levels). A two-level hierarchical model in which patients were level 1 and the institution was level 2 was used. RESULTS: Hierarchical multivariate linear regression analysis revealed that in the population not stratified by sex, body size was significantly correlated with eA/I and eL/I (P < .001) and that LBW exhibited the strongest correlation with eA/I and eL/I (r = -0.561 and r = -0.601, respectively). Sex-stratified analysis showed that LBW was more strongly correlated with eA/I and eL/I in women (r = -0.779 and r = -0.948, respectively) than in men (r = -0.500 and r = -0.494, respectively) or in the nonstratified total population. CONCLUSION: Among body size parameters, LBW exhibited the strongest correlation with aortic and hepatic enhancement, especially in women.


Assuntos
Tamanho Corporal , Meios de Contraste/administração & dosagem , Iodo/administração & dosagem , Hepatopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
J Comput Assist Tomogr ; 39(4): 629-34, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26125298

RESUMO

OBJECTIVE: To evaluate the image quality and radiation dose reduction in pelvic computed tomography (CT) achieved with an adaptive iterative dose reduction 3-dimensional (AIDR 3D) algorithm using a phantom model. METHODS: Two phantoms were scanned using a 320-detector row CT scanner with 8 tube current levels, and the images were reconstructed with a standard filtered back projection (FBP) algorithm and with an AIDR 3D algorithm. RESULTS: Compared with FBP, AIDR 3D reduced image noise and improved contrast-to-noise ratios. The diagnostic performance for detection of low-contrast targets of AIDR 3D images obtained with 100 mA at 120 kVp was almost as good as that of the FBP images obtained with 200 mA. CONCLUSIONS: The AIDR 3D algorithm substantially reduced image noise and improved the image quality of pelvic CT images compared with those obtained with the FBP algorithm and can thus be considered a promising technique for low-dose pelvic CT examinations.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Doses de Radiação , Razão Sinal-Ruído
7.
Eur J Radiol ; 84(9): 1715-23, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26037266

RESUMO

PURPOSE: To evaluate the image quality of upper abdominal CT images reconstructed with model-based iterative reconstruction (MBIR) in comparison with filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) on scans acquired with various radiation exposure dose protocols. MATERIALS AND METHODS: This prospective study was approved by our institutional review board, and informed consent was obtained from all 90 patients who underwent both control-dose (CD) and reduced-dose (RD) CT of the upper abdomen (unenhanced: n=45, contrast-enhanced: n=45). The RD scan protocol was randomly selected from three protocols; Protocol A: 12.5% dose, Protocol B: 25% dose, Protocol C: 50% dose. Objective image noise, signal-to-noise (SNR) ratio for the liver parenchyma, visual image score and lesion conspicuity were compared among CD images of FBP and RD images of FBP, ASIR and MBIR. RESULTS: RD images of MBIR yielded significantly lower objective image noise and higher SNR compared with RD images of FBP and ASIR for all protocols (P<.01) and CD images of FBP for Protocol C (P<.05). Although the subjective image quality of RD images of MBIR was almost acceptable for Protocol C, it was inferior to that of CD images of FBP for Protocols A and B (P<.0083). The conspicuity of the small lesions in RD images of MBIR tended to be superior to that in RD images of FBP and ASIR and inferior to that in CD images for Protocols A and B, although the differences were not significant (P>.0083). CONCLUSION: Although 12.5%-dose MBIR images (mean size-specific dose estimates [SSDE] of 1.13mGy) yielded objective image noise and SNR comparable to CD-FBP images, at least a 50% dose (mean SSDE of 4.63mGy) would be needed to maintain the subjective image quality and the lesion conspicuity.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Surgery ; 157(2): 269-76, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25311263

RESUMO

BACKGROUND: Pancreatic neuroendocrine tumors (PNETs) present various histologic stages, and their clinical behavior ranges from benign to highly aggressive. World Health Organization (WHO) grading categorizes PNETs into 3 groups (G1, G2, and G3) based on proliferative activity. The aim of this study was to assess the clinical utility of 2-[(18)F] fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in preoperative differential diagnosis for various histologic grades of PNETs and in predicting postoperative prognosis in PNET patients. METHODS: We investigated prospectively 36 patients who underwent preoperative FDG-PET, received surgery for PNETs, and had resected specimens examined via histology. The maximum standardized uptake value (SUVmax) was determined on FDG-PET, and differentiating power between G1/G2 and G3 PNETs was examined using various SUVmax cutoff levels. We also evaluated the prognostic impact of FDG-PET findings using postoperative survival data. RESULTS: SUVmax significantly correlated with WHO grade (Spearman rank correlation 0.584; P = .0018), and the SUVmax of G3 tumors (5.0 ± 2.5; n = 4) was significantly higher than that of G1/G2 tumors (2.7 ± 1.6; n = 32; P = .0159). Using 2.5 as a cutoff SUVmax, the sensitivity, specificity, and accuracy of differentiating G3 tumors from G1/G2 tumors were 100.0%, 62.5%, and 66.7%, respectively. Furthermore, the SUVmax of FDG-PET (<2.5 vs ≥2.5) was significantly related to postoperative disease-free survival (P = .0463). CONCLUSION: These results suggest that FDG-PET may be useful for differentiating G3 PNETs from G1/G2 PNETs and for predicting postoperative prognosis in PNET patients. This preliminary finding is expected to be confirmed by prospective validation with more patients.


Assuntos
Fluordesoxiglucose F18 , Tumores Neuroendócrinos/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Compostos Radiofarmacêuticos , Adulto , Idoso , Diagnóstico Diferencial , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Tumores Neuroendócrinos/patologia , Neoplasias Pancreáticas/patologia , Tomografia por Emissão de Pósitrons , Prognóstico , Estudos Prospectivos , Organização Mundial da Saúde
9.
Acad Radiol ; 22(3): 303-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25491738

RESUMO

RATIONALE AND OBJECTIVES: To investigate the usefulness of the statistical shape model (SSM) for the quantification of liver shape to evaluate hepatic fibrosis. MATERIALS AND METHODS: Ninety-one subjects (45 men and 46 women; age range, 20-75 years) were included in this retrospective study: 54 potential liver donors and 37 patients with chronic liver disease. The subjects were classified histopathologically according to the fibrosis stage as follows: F0 (n = 55); F1 (n = 6); F2 (3); F3 (n = 1); and F4 (n = 26). Each subject underwent contrast-enhanced computed tomography (CT) using a 64-channel scanner (0.625-mm slice thickness). An abdominal radiologist manually traced the liver boundaries on every CT section using an image workstation; the boundaries were used for subsequent analyses. An SSM was constructed by the principal component analysis of the subject data set, which defined a parametric model of the liver shapes. The shape parameters were calculated by fitting SSM to the segmented liver shape of each subject and were used for the training of a linear support vector regression (SVR), which classifies the liver fibrosis stage to maximize the area under the receiver operating characteristic curve (AUC). SSM/SVR models were constructed and were validated in a leave-one-out manner. The performance of our technique was compared to those of two previously reported types of caudate-right lobe ratios (C/RL-m and C/RL-r). RESULTS: In our SSM/SVR models, the AUC values for the classification of liver fibrosis were 0.96 (F0 vs. F1-4), 0.95 (F0-1 vs. F2-4), 0.96 (F0-2 vs. F3-4), and 0.95 (F0-3 vs. F4). These values were significantly superior to AUC values using the C/RL-m or C/RL-r ratios (P < .005). CONCLUSIONS: SSM was useful for estimating the stage of hepatic fibrosis by quantifying liver shape.


Assuntos
Cirrose Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
10.
Acta Radiol ; 56(9): 1034-41, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25267921

RESUMO

BACKGROUND: Diffusion-weighted magnetic resonance imaging (DW-MRI) and 2-deoxy-2-[18F]fluoro-D-glucose-positron emission tomography/computed tomography (PET/CT) is increasingly recognized as important for assessing tumor malignancy in oncology. Apparent diffusion coefficient (ADC) and standardized uptake value (SUV) are negatively correlated in some types of cancer based on tumor aggressiveness. PURPOSE: To evaluate relationships between ADC of magnetic resonance imaging and SUV of PET/CT in pancreatic adenocarcinomas. MATERIAL AND METHODS: Twenty-nine patients histopathologically diagnosed with pancreatic adenocarcinomas were evaluated. ADC maps were generated from 3 T-MRI using b values (b = 0, 800 s/mm(2)). PET/CT was performed 60 min after intravenous injection of FDG (3.7 MBq/kg). The margins of tumors on DW-MRI and PET/CT were assessed to measure ADC and SUV of tumor appropriately. For tumors considered well-marginated, minimal and mean ADC as well as maximal and mean SUV were measured. The correlation of ADC and SUV were statistically evaluated and survival period stratified on ADC and SUV also evaluated. RESULTS: Twenty-two tumors on DW-MRI and 25 on PET/CT were deemed well-marginated. Minimal ADC was significantly and negatively correlated with maximal and mean SUV (r = -0.61, P = 0.0040; r = -0.66, P = 0.0015), and mean ADC also showed significantly and negatively correlation with maximal and mean SUV (r = -0.50, P = 0.024; r = -0.54, P = 0.012). There was no significant difference on overall survival stratified on ADC and SUV. CONCLUSION: ADC and SUV were significantly correlated in pancreatic adenocarcinomas, although no significant findings were observed in overall survival.


Assuntos
Adenocarcinoma/diagnóstico , Imagem Multimodal , Neoplasias Pancreáticas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Imagem de Difusão por Ressonância Magnética , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Técnicas de Imagem de Sincronização Respiratória , Estudos Retrospectivos , Taxa de Sobrevida , Tomografia Computadorizada por Raios X , Neoplasias Pancreáticas
11.
Springerplus ; 3: 234, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24891998

RESUMO

OBJECTIVE: The purpose of this study was to compare the effects of high-concentration contrast material and low-voltage CT simulated by virtual monochromatic (VM) imaging on contrast enhancement at multiphasic CT of the upper abdomen. METHODS: This study included 72 patients who underwent CT during early arterial (EAP), late arterial and portal venous phases after 300-mgI/ml (Group A; 34 patients) or 350-mg/ml (Group B; 38 patients) contrast-material injection at the same volumetric rate (0.067 mL/sec/kg). VM images were generated at 50 and 65 keV. Contrast-to-noise ratios (CNRs) of aorta, portal vein, and liver parenchyma were calculated and statistically compared. RESULTS: Mean CNRs for 50-keV VM images were significantly higher than 65-keV VM images of each organ at any phases (p < 0.05), except for hepatic parenchyma in EAP. Aortic CNRs in EAP on 65- and 50-keV images of Group B were significantly higher than Group A (p <0.05, respectively). Aortic CNR on 50-keV images of Group A and on 65-keV images of Group B were 11% and 21% higher than 65-keV images of Group A, respectively. CONCLUSIONS: Low-voltage CT simulated by VM image improved contrast enhancement through any phases, while high-concentration contrast material increased only arterial contrast in EAP more effectively.

12.
Invest Radiol ; 49(8): 524-31, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24637584

RESUMO

OBJECTIVES: The objectives of this study were to correlate fluorodeoxyglucose uptake in ovarian masses on positron emission tomography/computed tomography (PET/CT) with pathological grades of malignancy and subtypes and to determine the appropriate approach for combining PET/CT and contrast-enhanced magnetic resonance imaging (CE-MRI) to characterize ovarian masses. MATERIALS AND METHODS: A retrospective study was conducted including 127 patients who underwent surgical resection of an ovarian mass (30 benign, 31 borderline, 66 malignant). Maximum standardized uptake values (SUVmax) obtained with PET/CT were compared between pathological grades of malignancy and subtypes. Two radiologists each independently conducted a blind evaluation of CE-MRI for all lesions and classified them by the grade of malignancy as determinate (benign, borderline, or malignant) or indeterminate and by subtype as mucinous or nonmucinous. The appropriate approach for combining CE-MRI and PET/CT was determined by comparing the combined diagnostic ability with that of CE-MRI alone. RESULTS: The SUVmax of malignant tumors was significantly higher than that of benign and borderline lesions (mean, 7.8, 1.7, 2.4; P < 0.05). Among malignant tumors, SUVmax was significantly lower in mucinous adenocarcinomas compared with nonmucinous malignant tumors (mean, 3.3, 8.4; P < 0.05) and lower in clear cell adenocarcinomas compared with other subtypes of nonmucinous malignant tumors (mean, 6.0, 9.4; P < 0.05). The SUVmax cutoff that best differentiated malignant lesions from benign/borderline lesions was 2.4 for mucinous and 4.0 for nonmucinous tumors. These cutoffs correctly classified lesions as malignant or not in 88.2% of cases (112/127). When PET/CT was combined with CE-MRI, the readers correctly classified 85% (34/40) and 86.5% (32/37) of indeterminate lesions on CE-MRI. However, PET/CT was not useful for classifying determinate lesions on CE-MRI, particularly because PET/CT correctly classified only 70.1% (12/17) of clear cell adenocarcinomas, whereas CE-MRI alone correctly classified 94.1% (1617). Thus, compared with CE-MRI alone, the diagnostic accuracy of CE-MRI + PET/CT when PET/CT was added only for indeterminate lesions on CE-MRI was significantly higher for both readers for differentiating between benign and borderline/malignant (P < 0.05), as well as between benign/borderline and malignant (P < 0.01). CONCLUSION: Fluorodeoxyglucose uptake in ovarian masses correlates with pathological subtypes as well as the grade of malignancy. Furthermore, the combination of CE-MRI and PET/CT is a highly accurate method for characterizing ovarian masses because PET/CT can be used as a complement to classify indeterminate lesions as malignant or not based on appropriate cutoff SUVmax for mucinous and nonmucinous tumors.


Assuntos
Fluordesoxiglucose F18 , Compostos Heterocíclicos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Compostos Organometálicos , Neoplasias Ovarianas/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacocinética , Feminino , Fluordesoxiglucose F18/farmacocinética , Gadolínio/farmacocinética , Compostos Heterocíclicos/farmacocinética , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Compostos Organometálicos/farmacocinética , Neoplasias Ovarianas/metabolismo , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Eur Radiol ; 23(8): 2296-305, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23508278

RESUMO

OBJECTIVES: To prospectively assess the efficacy of 3-T magnetic resonance (MR) imaging using the three-dimensional turbo spin-echo T2-weighted and diffusion-weighted technique (3D-TSE/DW) compared with that of conventional imaging using the two-dimensional turbo spin-echo T2-weighted and dynamic contrast-enhanced technique (2D-TSE/DCE) for the preoperative staging of endometrial cancer, with pathological analysis as the reference standard. METHODS: Seventy-one women with endometrial cancer underwent MR imaging using 3D-TSE/DW (b = 1,000 s/mm(2)) and 2D-TSE/DCE. Two radiologists independently assessed the two imaging sets. Accuracy, sensitivity, and specificity for staging were analysed with the McNemar test; the areas under the receiver operating characteristic curve (Az) were compared with a univariate z-score test. RESULTS: The results for assessing deep myometrial invasion, accuracy, sensitivity, specificity and Az, respectively, were as follows: 3D-TSE/DW-observer 1, 87 %, 95 %, 85 % and 0.96; observer 2, 92 %, 84 %, 94 % and 0.95; 2D-TSE/DCE-observer 1, 80 %, 79 %, 81 % and 0.89; observer 2, 86 %, 84 %, 87 % and 0.86. Most of the values were higher with 3D-TSE/DW without significant differences (P > 0.12). For assessing cervical stromal invasion, there were no significant differences in those values for both observers (P > 0.6). CONCLUSIONS: Accuracy of 3D-TSE/DW was at least equivalent to that of the conventional technique for the preoperative assessment of endometrial cancer. KEY POINTS: • New techniques in MR imaging help assess patients with endometrial cancer. • A 3D T2-weighted TSE sequence seems equally as accurate as conventional techniques. • Three-dimensional TSE/DW imaging does not require intravenous contrast material and is relatively quick. • Tumour extent of endometrial cancer can be clearly shown on diffusion-weighted images. • Junctional zone can be visualised well on 3D-TSE T2-weighted images.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/diagnóstico , Neoplasias do Endométrio/cirurgia , Imageamento Tridimensional/métodos , Estadiamento de Neoplasias/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/química , Neoplasias do Endométrio/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Miométrio/patologia , Variações Dependentes do Observador , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Oncology ; 84 Suppl 1: 21-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23428854

RESUMO

We summarize here the consensus reached at the Symposium of the 48th Annual Meeting of the Liver Cancer Study Group of Japan held in Kanazawa on July 20th and 21st, 2012, on the role of gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging (EOB-MRI) in the management of hepatocellular carcinoma (HCC). Currently, dynamic CT is the first choice of imaging modality when HCC is suspected. EOB-MRI is useful for differentiation and definitive diagnosis of HCC when dynamic CT/MRI does not show conclusive findings for HCC. In addition, contrast- enhanced ultrasound with Sonazoid is useful for making a decision on whether or not to treat a hypovascular lesion <1 cm when the nodules are shown with low intensity in the hepatocyte phase of EOB-MRI. Furthermore, EOB-MRI should be performed in selected cases of HCC ultrahigh-risk groups every 3-4 months, or EOB-MRI should be performed at least once at the first visit in all HCC ultrahigh-risk groups.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Meios de Contraste , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética , Algoritmos , Carcinoma Hepatocelular/terapia , Humanos , Aumento da Imagem , Japão , Neoplasias Hepáticas/terapia
15.
Magn Reson Med Sci ; 11(2): 117-27, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22790298

RESUMO

PURPOSE: We retrospectively compared the efficacy of 3-dimensional (3D) gradient-echo magnetic resonance T(1)-weighted sequence using the iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) technique with the efficacy of conventional 3D gradient-echo sequences for diagnosing ovarian masses at 3T. MATERIALS AND METHODS: In images of 32 women (mean age, 45.3 years) with ovarian masses who underwent T(1)-weighted imaging with both IDEAL and conventional techniques, we quantitatively analyzed signal-to-noise ratio (SNR) and contrast between gluteal muscle and T(1)-weighted high-signal materials within lesions and assessed image quality. Two radiologists independently evaluated fat detection. RESULTS: Mean SNR of subcutaneous fat did not differ significantly between IDEAL and conventional techniques for both fat-suppressed (P=.32) and non-fat-suppressed (P=.85) images. Mean absolute contrast between gluteal muscle and T(1)-weighted high signal materials within teratomas (n=15) was significantly higher with IDEAL on fat-suppressed images (P=.002) and lower with IDEAL on non-fat-suppressed images (P=.010). Fat suppression was significantly superior with IDEAL (P<.0001). Readers' assessments of fat detection did not differ between IDEAL and conventional sequences. CONCLUSION: The quality of T(1)-weighted fat-suppressed images of ovarian masses was better with 3D gradient-echo IDEAL than conventional 3D gradient-echo sequences.


Assuntos
Tecido Adiposo/patologia , Água Corporal/química , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias Ovarianas/química , Neoplasias Ovarianas/patologia , Adulto , Idoso , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Eur Radiol ; 22(4): 845-54, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22057248

RESUMO

OBJECTIVES: To retrospectively compare the accuracy of detection of hypervascular hepatocellular carcinoma (HCC) by multiphasic multidetector CT and by gadoxetate disodium-enhanced MR imaging. METHODS: After ethical approval, we analysed a total of 73 hypervascular HCC lesions from 31 patients suspected of having HCC, who underwent both gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Five blinded observers independently reviewed CT images, as well as dynamic MR images alone and combined with hepatobiliary phase MR images. Diagnostic accuracy (Az values), sensitivities and positive predictive values were compared by using the Scheffe post hoc test. RESULTS: The mean Az value for dynamic and hepatobiliary phase MR combined (0.81) or dynamic MR images alone (0.78) was significantly higher than that for CT images (0.67, P < 0.001, 0.005, respectively). The mean sensitivity of the combined MR images (0.67) was significantly higher than that of dynamic MR alone (0.52, P < 0.05) or CT images (0.44, P < 0.05). The mean positive predictive values were 0.96, 0.95 and 0.94, for CT, dynamic MR alone and combined MR images, respectively. CONCLUSIONS: Compared with multiphasic multidetector CT, gadoxetate disodium-enhanced MR imaging combining dynamic and hepatobiliary phase images results in significantly improved sensitivity and diagnostic accuracy for detection of hypervascular HCC. KEY POINTS: Gadoxetate disodium is a new liver-specific MR imaging contrast agent. Gadoxetate disodium-enhanced MRI helps the assessment of patients with liver disease. It showed high diagnostic accuracy for the detection of hepatocellular carcinoma.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Neovascularização Patológica/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
Int J Cancer ; 130(2): 319-27, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-21328580

RESUMO

Insulin-like growth factor-binding protein 7 (IGFBP7) functions in several cellular processes including proliferation, senescence and apoptosis. This study analyzed IGFBP7 function in hepatocellular carcinoma (HCC) cells by gene manipulation and investigated the prognostic significance of IGFBP7 expression in clinical HCC samples. In this study, we investigated changes in malignant potential such as cell growth and invasiveness in an HCC cell line, PLC/PRF/5, after transfection with shRNA against IGFBP7. The extent of apoptosis and cell cycle progression were examined after the transfection. The correlation between immunohistochemically determined IGFBP7 expression and long-term postoperative prognosis after curative resection was also investigated in clinical HCC specimens obtained from 104 patients. PLC/PRF/5 cells transfected with shRNA against IGFBP7 showed significantly more rapid growth and stronger invasiveness than control cells. Annexin V assays showed that the IGFBP7-depleted cells were significantly more resistant to apoptosis than the control cells, and showed decreased expression of cleaved caspase-3 and PARP. Cell cycle progression was more rapid in the IGFBP7-suppressed cells. In clinical HCC specimens, IGFBP7 expression was judged as positive in 67 patients (64.4%) and negative in the remaining 37 patients (35.6%). The IGFBP7 downregulation correlated significantly with poor postoperative prognosis, and IGFBP7 status was identified as an independent significant prognostic factor. Our results indicated that IGFBP7 expression correlated significantly with the malignant potential in HCC cells, suggesting that the expression could be a useful prognostic marker for HCC.


Assuntos
Carcinoma Hepatocelular/metabolismo , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/biossíntese , Neoplasias Hepáticas/metabolismo , Carcinoma Hepatocelular/genética , Carcinoma Hepatocelular/patologia , Linhagem Celular Tumoral , Progressão da Doença , Regulação para Baixo , Humanos , Imuno-Histoquímica , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/genética , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/patologia , Prognóstico , Transfecção
18.
Eur Radiol ; 22(4): 872-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22120061

RESUMO

PURPOSE: This study was aimed to compare the accuracy, sensitivity, and positive predictive value of C-arm CT (CACT) during selective transcatheter angiography with those of multidetector CT (MDCT) in the detection of hepatocellular carcinoma (HCC). MATERIAL AND METHODS: In this prospective study, 30 patients (mean age, 73 years) with unresectable HCC were examined with CACT before chemoembolisation. Images of a combination of CACT during arterial portography (CACTAP) and dual-phase CACT during hepatic arteriography (CACTHA) was obtained and images of intravenous contrast-enhanced, biphasic, dynamic, MDCT was also obtained beforehand. Three blinded observers independently reviewed CACT and MDCT. Diagnostic accuracy was evaluated by the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values (PPV) were analyzed with the paired t-test. RESULTS: In the mean area under the AFROC curve (Az), there was no significant difference between MDCT and CACT (MDCT, mean Az value, 0.83; CACT, 0.85, respectively) (P = 0.32). There was also no significant difference between the two techniques in sensitivity (MDCT, mean 0.65; CACT, 0.60) and PPV (MDCT, mean 0.98; CACT, 0.97) (P = 0.40, P = 0.68, respectively). CONCLUSION: The diagnostic accuracy of CACT was equivalent to that of biphasic CT in the diagnosis of HCC. KEY POINTS: C-arm CT helps detection of hepatocellular carcinoma (HCC) during interventional (TACE) treatment. C-arm CT for HCC seemed just as accurate as biphasic CT. TACE can be performed with greater confidence using C-arm CT.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Iopamidol/análogos & derivados , Neoplasias Hepáticas/diagnóstico por imagem , Portografia/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Cateterismo , Meios de Contraste/administração & dosagem , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Injeções Intra-Arteriais , Injeções Intravenosas , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Portografia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Surgery ; 149(5): 672-9, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21310453

RESUMO

BACKGROUND AND PURPOSE: Preoperative T staging demands high accuracy, because it greatly influences subsequent therapies in advanced gastric cancer. PATIENTS AND METHODS: 616 patients with gastric cancer underwent multi-detector row computed tomography (MDCT) before operation. The results were compared with operative and pathologic findings. Especially, we evaluated the correlations among the diagnostic accuracy of T staging and various clinicopathologic parameters by focusing on 276 patients who had detectable lesions by MDCT. RESULTS: The overall diagnostic accuracy of preoperative T staging by MDCT was 90.9% (560/616). For each pathologic T stage, the accuracy was 95% for pT1, 76% for pT2-3, 92% for pT4a, and 75% for pT4b, respectively. Among the 276 patients, 239 (87%) were correctly staged by MDCT whereas 29 (11%) and 8 (3%) were over- or under-staged, respectively. Antral tumors (P = .045), and Borrmann type 1 tumors (P = .0001) were incorrectly T staged by MDCT, whereas differentiated type tumors tended to be over-staged. All patients with positive cytology (n = 12 cases) and peritoneal metastasis (n = 7 cases) diagnosed at laparotomy had been diagnosed as T4a or deeper by MDCT. The 5-year overall survival rates classified by preoperative T staging by MDCT (T1/T2-3/T4a/T4b) were 100%, 89%, 59%, and 31%, respectively, whereas those for each pT stage were 100%, 84%, 59%, and 19%. CONCLUSION: Preoperative T staging of gastric cancer by MDCT is highly accurate and could contribute to treatment strategies, particularly in advanced disease.


Assuntos
Adenocarcinoma/patologia , Estadiamento de Neoplasias/métodos , Neoplasias Gástricas/patologia , Tomografia Computadorizada Espiral/métodos , Adenocarcinoma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Prognóstico , Estudos Retrospectivos , Sensibilidade e Especificidade , Neoplasias Gástricas/diagnóstico por imagem , Taxa de Sobrevida
20.
Int J Clin Oncol ; 16(4): 408-15, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21347626

RESUMO

OBJECTIVE: To demonstrate that positron emission tomography (PET)/magnetic resonance imaging (MRI) fusion was feasible in characterizing pancreatic tumors (PTs), comparing MRI and computed tomography (CT) as mapping images for fusion with PET as well as fused PET/MRI and PET/CT. METHODS: We retrospectively reviewed 47 sets of (18)F-fluorodeoxyglucose ((18)F -FDG) PET/CT and MRI examinations to evaluate suspected or known pancreatic cancer. To assess the ability of mapping images for fusion with PET, CT (of PET/CT), T1- and T2-weighted (w) MR images (all non-contrast) were graded regarding the visibility of PT (5-point confidence scale). Fused PET/CT, PET/T1-w or T2-w MR images of the upper abdomen were evaluated to determine whether mapping images provided additional diagnostic information to PET alone (3-point scale). The overall quality of PET/CT or PET/MRI sets in diagnosis was also assessed (3-point scale). These PET/MRI-related scores were compared to PET/CT-related scores and the accuracy in characterizing PTs was compared. RESULTS: Forty-three PTs were visualized on CT or MRI, including 30 with abnormal FDG uptake and 13 without. The confidence score for the visibility of PT was significantly higher on T1-w MRI than CT. The scores for additional diagnostic information to PET and overall quality of each image set in diagnosis were significantly higher on the PET/T1-w MRI set than the PET/CT set. The diagnostic accuracy was higher on PET/T1-w or PET/T2-w MRI (93.0 and 90.7%, respectively) than PET/CT (88.4%), but statistical significance was not obtained. CONCLUSION: PET/MRI fusion, especially PET with T1-w MRI, was demonstrated to be superior to PET/CT in characterizing PTs, offering better mapping and fusion image quality.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Pancreáticas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Radiografia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...