Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(16)2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-34450722

RESUMO

The consumption of seaweed is increasing year by year worldwide. Therefore, the foreign object inspection of seaweed is becoming increasingly important. Seaweed is mixed with various materials such as laver and sargassum fusiforme. So it has various colors even in the same seaweed. In addition, the surface is uneven and greasy, causing diffuse reflections frequently. For these reasons, it is difficult to detect foreign objects in seaweed, so the accuracy of conventional foreign object detectors used in real manufacturing sites is less than 80%. Supporting real-time inspection should also be considered when inspecting foreign objects. Since seaweed requires mass production, rapid inspection is essential. However, hyperspectral imaging techniques are generally not suitable for high-speed inspection. In this study, we overcome this limitation by using dimensionality reduction and using simplified operations. For accuracy improvement, the proposed algorithm is carried out in 2 stages. Firstly, the subtraction method is used to clearly distinguish seaweed and conveyor belts, and also detect some relatively easy to detect foreign objects. Secondly, a standardization inspection is performed based on the result of the subtraction method. During this process, the proposed scheme adopts simplified and burdenless calculations such as subtraction, division, and one-by-one matching, which achieves both accuracy and low latency performance. In the experiment to evaluate the performance, 60 normal seaweeds and 60 seaweeds containing foreign objects were used, and the accuracy of the proposed algorithm is 95%. Finally, by implementing the proposed algorithm as a foreign object detection platform, it was confirmed that real-time operation in rapid inspection was possible, and the possibility of deployment in real manufacturing sites was confirmed.


Assuntos
Corpos Estranhos , Alga Marinha , Algoritmos , Imageamento Hiperespectral , Verduras
2.
Sensors (Basel) ; 18(3)2018 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-29534483

RESUMO

Recently, radar technology has attracted attention for the realization of an intelligent transportation system (ITS) to monitor, track, and manage vehicle traffic on the roads as well as adaptive cruise control (ACC) and automatic emergency braking (AEB) for driving assistance of vehicles. However, when radar is installed on roads or in tunnels, the detection performance is significantly dependent on the deployment conditions and environment around the radar. In particular, in the case of tunnels, the detection accuracy for a moving vehicle drops sharply owing to the diffuse reflection of radio frequency (RF) signals. In this paper, we propose an optimal deployment condition based on height and tilt angle as well as a noise-filtering scheme for RF signals so that the performance of vehicle detection can be robust against external conditions on roads and in tunnels. To this end, first, we gather and analyze the misrecognition patterns of the radar by tracking a number of randomly selected vehicles on real roads. In order to overcome the limitations, we implement a novel road watch module (RWM) that is easily integrated into a conventional radar system such as Delphi ESR. The proposed system is able to perform real-time distributed data processing of the target vehicles by providing independent queues for each object of information that is incoming from the radar RF. Based on experiments with real roads and tunnels, the proposed scheme shows better performance than the conventional method with respect to the detection accuracy and delay time. The implemented system also provides a user-friendly interface to monitor and manage all traffic on roads and in tunnels. This will accelerate the popularization of future ITS services.

3.
Ann Hepatobiliary Pancreat Surg ; 20(4): 180-186, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28261697

RESUMO

BACKGROUNDS/AIMS: We investigated patients' clinical and radiological data to determine preoperative factors that predict cholesterol gallbladder (GB) polyps of large size, which can be helpful for decision on further diagnostic tools. METHODS: In this study, we retrospectively analyzed 126 patients who underwent laparoscopic cholecystectomy for GB polyps >10 mm diagnosed preoperatively by abdominal ultrasonography between February 2002 and February 2016 in Department of Surgery, Sanggye Paik Hospital. Patients were divided into non-cholesterol polyps group and cholesterol polyps group, based on the postoperative pathologic diagnosis. Clinical and radiological data, such as gender, age, body weight, height, body mass index (BMI), laboratory findings, size, number and shape of the polypoid lesions, and presence of the concurrent GB stone were compared between the two groups. RESULTS: Of the 126 cases, 73 had cholesterol polyps (57.9%) and 53 cases were non-cholesterol polyps (42.1%). The younger age (<48.5 years), size of polyp <13.25 mm and multiple polyps were independent predictive variables for cholesterol polyps, with odd ratios (OR) of 2.352 (p=0.045), 5.429 (p<0.001) and 0.472 (p<0.001), respectively. CONCLUSIONS: Age, size and polyp number were used to predict cholesterol GB polyp among polypoid lesions of the gallbladder >10 mm. For cases in which these factors are not applicable, it is strongly recommended to evaluate further diagnostic tools, such as computed tomography, endoscopic ultrasonography and tumor markers.

4.
Ann Coloproctol ; 31(5): 187-91, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26576397

RESUMO

PURPOSE: Previous studies have revealed that predictors and risk factors of pulmonary thromboembolism (PTE) are malignancy, immobilization, diabetes, and obesity in the postoperative patients. However, in patients undergoing colorectal cancer, studies of PTE have not been enough. Thus, we investigated the risk factors of PTE related to colorectal surgery. METHODS: From January 2009 to October 2014, 312 patients received colorectal surgery without other organ resection. The postoperative patients with PTE were 14 (4.5%), and they were classified by sex, age, and stage as a 1:3 paired match to the control group. A multiple logistic regression was performed to identify which factors were associated with PTE. RESULTS: One patient was in stage I, 3 in stage II, 9 in stage III, and 1 in stage IV. In the binary logistic regression analysis, history of diabetes mellitus (odds ratio, 6.498; P = 0.031) and being overweight (odds ratio, 10.018; P = 0.014) were independent risk factors for PTE in patients undergoing colorectal cancer. CONCLUSION: A history of diabetes mellitus and being overweight were independent risk factors of PTE after colorectal cancer.

5.
Ann Coloproctol ; 30(6): 274-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25580414

RESUMO

PURPOSE: Many studies have shown that the completion of adjuvant chemotherapy improves the survival rate. Recently, laparoscopic surgery has been used to treat patients with colon cancer. We analyzed the relationship between the completion of adjuvant chemotherapy and the operation method. METHODS: We retrospectively analyzed the medical records of 147 patients diagnosed with colon cancer from January 1, 2009, to May 31, 2012. The numbers of patients who underwent laparoscopic and open surgery were 91 and 56, respectively. We analyzed the relationship between the operation method and various factors such as the completion rate of chemotherapy, the patient's age, gender, and physical activity, the postoperative hospital stay, the start time of chemotherapy, and the patient's body mass index (BMI), TNM stage, and type of health insurance. RESULTS: In the laparoscopic surgery group, the postoperative hospital stay (13.5 ± 14.82 days vs. 19.6 ± 11.38 days, P = 0.001) and start time of chemotherapy (17.7 ± 17.48 days vs. 23.0 ± 15.00 days, P = 0.044) were shorter, but the percent complete of chemotherapy (71/91 [78.0%] vs. 38/56 [67.8%], P = 0.121), and survival rate (88/91 [96.7%], 47/56 [83.9%], P = 0.007) were higher than they were in the open surgery group. Patients who were elderly, had a low BMI, and a high American Society of Anesthesiologists score were less likely to complete adjuvant chemotherapy than other patients were. CONCLUSION: Laparoscopic surgery shows a shorter postoperative hospital stay, a shorter start time of chemotherapy, and a higher survival rate. Laparoscopic surgery may be expected to increase compliance of chemotherapy and to improve survival rate.

6.
Opt Express ; 21(15): 17839-48, 2013 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-23938657

RESUMO

We propose a new method for high-speed, three-dimensional (3-D) fluorescence imaging, which we refer to as dual-detection confocal fluorescence microscopy (DDCFM). In contrast to conventional beam-scanning confocal fluorescence microscopy, where the focal spot must be scanned either optically or mechanically over a sample volume to reconstruct a 3-D image, DDCFM can obtain the depth of a fluorescent emitter without depth scanning. DDCFM comprises two photodetectors, each with a pinhole of different size, in the confocal detection system. Axial information on fluorescent emitters can be measured by the axial response curve through the ratio of intensity signals. DDCFM can rapidly acquire a 3-D fluorescent image from a single two-dimensional scan with less phototoxicity and photobleaching than confocal fluorescence microscopy because no mechanical depth scans are needed. We demonstrated the feasibility of the proposed method by phantom studies.


Assuntos
Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Lentes , Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Microscopia de Fluorescência por Excitação Multifotônica/instrumentação , Imagem Molecular/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Imagem Molecular/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Rev Sci Instrum ; 84(12): 125005, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24387460

RESUMO

Interest in the production of printed electronics using a roll-to-roll system has gradually increased due to its low mass-production costs and compatibility with flexible substrate. To improve the accuracy of roll-to-roll manufacturing systems, the movement of the web needs to be measured precisely in advance. In this paper, a novel measurement method is developed to measure the displacement and velocity of the web precisely and directly. The proposed algorithm is based on the traditional single field encoder principle, and the scale grating has been replaced with a printed grating on the web. Because a printed grating cannot be as accurate as a scale grating in a traditional encoder, there will inevitably be variations in pitch and line-width, and the motion of the web should be measured even though there are variations in pitch and line-width in the printed grating patterns. For this reason, the developed algorithm includes a precise method of estimating the variations in pitch. In addtion, a method of correcting the Lissajous curve is presented for precision phase interpolation to improve measurement accuracy by correcting Lissajous circle to unit circle. The performance of the developed method is evaluated by simulation and experiment. In the experiment, the displacement error was less than 2.5 µm and the velocity error of 1σ was about 0.25%, while the grating scale moved 30 mm.

8.
J Breast Cancer ; 14(3): 223-8, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22031805

RESUMO

PURPOSE: Our study aimed to evaluate the feasibility of adjuvant cyclophosphamide/vinorelbine/5-fluorourail (CVF) chemotherapy as an alternative to cyclophosphamide/methotrexate/5-fluorouracil (CMF) chemotherapy for treating early breast cancer. METHODS: One hundred and forty-nine patients were randomly assigned to CMF or CVF adjuvant chemotherapy for treating their early stage breast cancer between September 2000 and December 2007. The disease-free survival (DFS), the overall survival (OS), and the toxicity profiles of both groups were compared. RESULTS: Sixty-seven patients underwent CMF chemotherapy whereas 82 patients underwent CVF chemotherapy. The DFS and OS were 88 months (95% confidence interval [CI], 76-101 months) and 94 months (95% CI, 83-104 months), respectively for the CMF group, and 97 months (95% CI, 93-101 months), and 101 months (95% CI, 98-104 months), respectively for the CVF group. However, those survival gains of the CVF group were not statistically significant (p-value=0.069 for the DFS and 0.99 for the OS). The CVF group showed a favorable toxicity profile in terms of the grade 3/4 hematologic toxicities as compared to that of the CMF group. CONCLUSION: Clinical outcome of CVF chemotherapy was comparable to CMF with a favorable toxicity profiles. However, it is difficult to conclude the feasibility of CVF regimen because of small number of studied patients.

9.
Korean J Ophthalmol ; 18(1): 84-8, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15255243

RESUMO

Air-bags have received widespread support as an effective means of enhancing automotive safety, and they are becoming more common as standard automobile equipment on many cars. Although air-bag induced ocular injuries are rare, they present a serious concern because of the possibility of permanent damage or visual impairment. To date, most reports have investigated ocular injury from high velocity motor vehicle accidents and reports of ocular injury from low speed motor vehicle accidents have been rare. We describe a patient who sustained severe ocular injury, including periorbital fracture, hyphema, vitreous hemorrhage, and choroidal rupture of the macular area, due to an inflated air-bag in a low speed motor vehicle accident.


Assuntos
Air Bags/efeitos adversos , Corioide/lesões , Traumatismos Oculares/etiologia , Hifema/etiologia , Fraturas Orbitárias/etiologia , Hemorragia Vítrea/etiologia , Acidentes de Trânsito , Adulto , Feminino , Humanos , Fraturas Orbitárias/diagnóstico por imagem , Ruptura , Tomografia Computadorizada por Raios X , Ultrassonografia , Hemorragia Vítrea/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...