1.
Epilepsy Behav Case Rep ; 10: 65-70, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30073145

RESUMO

OBJECTIVES: To investigate if glucose levels influence seizure patterns. MATERIALS AND METHODS: In a patient with RNS/NeuroPace implanted bi-temporally and type 1 diabetes mellitus, seizure event times and onset locations were matched to continuous tissue glucose. RESULTS: Left focal seizure (LFS, n = 22) glucoses averaged 169 mg/dL, while right focal seizure (RFS, n = 23) glucoses averaged 131 mg/dL (p = 0.03). LFS occurred at mean time 17:02 while RFS occurred at 04:23. LFS spread to the contralateral side (n = 19) more than RFS (n = 2). CONCLUSION: Seizure onset laterality and spread vary with glucose and time of seizure.

2.
Epilepsy Behav Case Rep ; 9: 33-36, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29692968

RESUMO

OBJECTIVES: To match responsive neurostimulator (RNS) and polysomnographic data to determine if RNS detections and stimulations correlate with measurements of sleep disordered breathing and continuous glucose measurements (CGM). MATERIALS AND METHODS: In a patient with an RNS with detection/stimulation leads implanted bi-temporally detection-stimulation counts were matched by time with coinciding polysomnogram and CGM data. RESULTS: Temporal dispersion of RNS DSC were independent of measures of sleep apnea, hypopnea or glucose. CONCLUSION: Hippocampal nighttime responsive neurostimulation therapies did not appear to worsen measures of normal or abnormal sleep.