1.
IEEE Trans Med Imaging ; 37(5): 1214-1223, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29727284

RESUMO

Shear wave elastography methods are able to accurately measure tissue stiffness, allowing these techniques to monitor the progression of hepatic fibrosis. While many methods rely on acoustic radiation force to generate shear waves for 2-D imaging, probe oscillation shear wave elastography (PROSE) provides an alternative approach by generating shear waves through continuous vibration of the ultrasound probe while simultaneously detecting the resulting motion. The generated shear wave field in in vivo liver is complicated, and the amplitude and quality of these shear waves can be influenced by the placement of the vibrating probe. To address these challenges, a real-time shear wave visualization tool was implemented to provide instantaneous visual feedback to optimize probe placement. Even with the real-time display, it was not possible to fully suppress residual motion with established filtering methods. To solve this problem, the shear wave signal in each frame was decoupled from motion and other sources through the use of a parameter-free empirical mode decomposition before calculating shear wave speeds. This method was evaluated in a phantom as well as in in vivo livers from five volunteers. PROSE results in the phantom as well as in vivo liver correlated well with independent measurements using the commercial General Electric Logiq E9 scanner.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/instrumentação , Humanos , Imagens de Fantasmas , Vibração
2.
IEEE Trans Biomed Eng ; 65(7): 1468-1475, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-28952929

RESUMO

OBJECTIVE: Ultrasound-guided biopsies and minimally invasive procedures have been used in numerous medical applications, including catheter guidance. The biggest challenge for catheter guidance by ultrasound lies in distinguishing the catheter from neighboring tissue, as well as the ability to differentiate the catheter body from its tip. METHODS: In our previous work, we introduced a functional prototype of an acoustically active catheter, in which a miniature piezoelectric crystal allowed accurate localization of the catheter tip by pulsed wave (PW) Doppler imaging and Doppler spectrogram. In this paper, the theory behind the symmetric Doppler shift due to the interaction of ultrasound wave with a vibrating piezoelectric crystal is explained. The theory is validated in an experimental continuous flow phantom setup. A novel algorithm, symmetric frequency detection algorithm, is presented for identification and visualization of the catheter tip in real time along with B-mode and PW Doppler. RESULTS: The catheter tip is identified with a distinct color differentiable from common Doppler colors with a frame rate varying from 22 to 50 Hz. The catheter tip can be visualized in a small region of 2.4 mm in the elevational direction. CONCLUSION: The algorithm can be implemented in most clinical ultrasound machines with minor additions to the PW Doppler processing algorithm. The algorithm is optimized to be robust for a variety of blood flow velocities and is shown to perform well when the signal from the blood is on par in amplitude with the catheter signal. SIGNIFICANCE: Unambiguous and distinct visualization of catheter tip facilitates real-time tracking of the catheter and aids minimally invasive procedures.


Assuntos
Cateterismo Cardíaco/métodos , Processamento de Sinais Assistido por Computador , Ultrassonografia de Intervenção/métodos , Algoritmos , Imagens de Fantasmas
3.
J Ultrasound Med ; 37(2): 501-509, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28777479

RESUMO

Opening a chest in an experimental echocardiographic animal study eliminates ultrasound signal attenuation by the chest wall. We developed a scanning technique that involves the use of an attenuative pad created from a mixture of urethane and titanium dioxide. The pad was interposed within transmission gel between the transducer face and cardiac surface in open-chest scans in a porcine model. Comparative measurements of left ventricular echogenicity without and with the pad demonstrate that the pad reproducibly causes ultrasound signal attenuation that closely mimics chest attenuation in clinical transthoracic echocardiographic studies.


Assuntos
Ecocardiografia/instrumentação , Ecocardiografia/métodos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Animais , Géis , Modelos Animais , Reprodutibilidade dos Testes , Suínos , Titânio , Transdutores , Uretana
4.
Artigo em Inglês | MEDLINE | ID: mdl-28866480

RESUMO

A lung ultrasound surface wave elastography (LUSWE) technique is developed to measure superficial lung tissue elastic properties. The purpose of this paper was to translate LUSWE into clinical studies for assessing patients with interstitial lung disease (ILD) and present the pilot data from lung measurements on 10 healthy subjects and 10 patients with ILD. ILD includes multiple lung disorders in which the lung tissue is distorted and stiffened by tissue fibrosis. Chest radiography and computed tomography are the most commonly used techniques for assessing lung disease, but they are associated with radiation and cannot directly measure lung elastic properties. LUSWE provides a noninvasive and nonionizing technique to measure the elastic properties of superficial lung tissue. LUSWE was used to measure regions of both lungs through six intercostal spaces for patients and healthy subjects. The data are presented as wave speed at 100, 150, and 200 Hz at the six intercostal spaces. As an example, the surface wave speeds are, respectively, 1.88 ± 0.11 m/s at 100 Hz, 2.74 ± 0.26 m/s at 150 Hz, and 3.62 ± 0.13 m/s at 200 Hz for a healthy subject in the upper right lung; this is in comparison to measurements from an ILD patient of 3.3 ± 0.37 m/s at 100 Hz, 4.38 ± 0.33 m/s at 150 Hz, and 5.24 ± 0.44 m/s at 200 Hz in the same lung space. Significant differences in wave speed between healthy subjects and ILD patients were found. LUSWE is a safe and noninvasive technique which may be useful for assessing ILD.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
5.
Radiol Case Rep ; 12(2): 348-352, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28491186

RESUMO

Spasticity is common following stroke; however, high subject variability and unreliable measurement techniques limit research and treatment advances. Our objective was to investigate the use of shear wave elastography (SWE) to characterize the spastic reflex in the biceps brachii during passive elbow extension in an individual with spasticity. The patient was a 42-year-old right-hand-dominant male with history of right middle cerebral artery-distribution ischemic infarction causing spastic left hemiparesis. We compared Fugl-Meyer scores (numerical evaluation of motor function, sensation, motion, and pain), Modified Ashworth scores (most commonly used clinical assessment of spasticity), and SWE measures of bilateral biceps brachii during passive elbow extension. We detected a catch that featured markedly increased stiffness of the brachialis muscle during several trials of the contralateral limb, especially at higher extension velocities. SWE was able to detect velocity-related increases in stiffness with extension of the contralateral limb, likely indicative of the spastic reflex. This study offers optimism that SWE can provide a rapid, real-time, quantitative technique that is readily accessible to clinicians for evaluating spasticity.

6.
IEEE Trans Biomed Eng ; 64(7): 1535-1546, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28113299

RESUMO

Noninvasive measurement of tissue viscoelastic properties is gaining more attention for screening and diagnostic purposes. Recently, measuring dynamic response of tissue under a constant force has been studied for estimation of tissue viscoelastic properties in terms of retardation times. The essential part of such a test is an instrument that is capable of creating a controlled axial force and is suitable for clinical applications. Such a device should be lightweight, portable, and easy to use for patient studies to capture tissue dynamics under external stress. In this paper, we present the design of an automated compression device for studying the creep response of materials with tissue-like behaviors. The device can be used to apply a ramp-and-hold force excitation for a predetermined duration of time and it houses an ultrasound probe for monitoring the creep response of the underlying tissue. To validate the performance of the device, several creep tests were performed on tissue-mimicking phantoms, and the results were compared against those from a commercial mechanical testing instrument. Using a second-order Kelvin-Voigt model and surface measurement of the forces and displacements, retardation times T1 and T2 were estimated from each test. These tests showed strong agreement between our automated compression device and the commercial mechanical testing system, with an average relative error of 2.9% and 12.4%, for T1 and T2, respectively. Also, we present the application of compression device to measure local retardation times for four different phantoms with different size and stiffness.


Assuntos
Módulo de Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/instrumentação , Testes de Dureza/instrumentação , Sistemas Microeletromecânicos/instrumentação , Estimulação Física/instrumentação , Transdutores de Pressão , Viscosidade , Desenho de Equipamento , Análise de Falha de Equipamento , Testes de Dureza/métodos , Humanos , Imagens de Fantasmas , Estimulação Física/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Acoust Soc Am ; 140(3): 1719, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27914388

RESUMO

Viscoelastic micellar fluid characteristics have been measured with mechanically generated shear waves and showed good agreement to shear oscillatory methods. In this paper, shear waves in wormlike micellar fluids using ultrasound were successfully generated and detected. Micellar fluids of different concentrations (100, 200, 300, and 400 mM) were studied with ultrasound-based and conventional rheology methods. The measured micellar fluid complex modulus from oscillatory shear tests between 0.001 and 15.91 Hz was characterized with an extended Maxwell fluid model. The elastic and viscous parameters found using rheological testing were used to estimate shear wave phase velocity over a frequency range from 100 to 500 Hz, and compared to shear wave velocity measured with ultrasound-based methods with a mean absolute error 0.02 m/s. The shear wave frequency content was studied and an increase in shear wave center frequency was found as a function of micellar fluid concentration. Moreover, the bias found in the shear wave group velocity with respect to rheological measurement is attributed to the micellar fluid viscous component. Finally, the shear wave phase velocity evaluated at the center frequency agreed well with the rheological measurements.


Assuntos
Ultrassom , Fenômenos Eletromagnéticos , Micelas , Reologia , Viscosidade
8.
IEEE Trans Med Imaging ; 35(9): 2098-106, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27076352

RESUMO

Ultrasound shear wave elastography (SWE) utilizes the propagation of induced shear waves to characterize the shear modulus of soft tissue. Many methods rely on an acoustic radiation force (ARF) "push beam" to generate shear waves. However, specialized hardware is required to generate the push beams, and the thermal stress that is placed upon the ultrasound system, transducer, and tissue by the push beams currently limits the frame-rate to about 1 Hz. These constraints have limited the implementation of ARF to high-end clinical systems. This paper presents Probe Oscillation Shear Elastography (PROSE) as an alternative method to measure tissue elasticity. PROSE generates shear waves using a harmonic mechanical vibration of an ultrasound transducer, while simultaneously detecting motion with the same transducer under pulse-echo mode. Motion of the transducer during detection produces a "strain-like" compression artifact that is coupled with the observed shear waves. A novel symmetric sampling scheme is proposed such that pulse-echo detection events are acquired when the ultrasound transducer returns to the same physical position, allowing the shear waves to be decoupled from the compression artifact. Full field-of-view (FOV) two-dimensional (2D) shear wave speed images were obtained by applying a local frequency estimation (LFE) technique, capable of generating a 2D map from a single frame of shear wave motion. The shear wave imaging frame rate of PROSE is comparable to the vibration frequency, which can be an order of magnitude higher than ARF based techniques. PROSE was able to produce smooth and accurate shear wave images from three homogeneous phantoms with different moduli, with an effective frame rate of 300 Hz. An inclusion phantom study showed that increased vibration frequencies improved the accuracy of inclusion imaging, and allowed targets as small as 6.5 mm to be resolved with good contrast (contrast-to-noise ratio ≥ 19 dB) between the target and background.


Assuntos
Técnicas de Imagem por Elasticidade , Artefatos , Imagens de Fantasmas , Transdutores , Ultrassonografia
9.
J Med Ultrason (2001) ; 42(1): 3-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26578484

RESUMO

PURPOSE: Vibro-acoustography is a new imaging technique based on the dynamic radiation force of ultrasound. The purpose of this study was to apply this new imaging technique to the diagnosis of small partial-thickness rotator cuff tears and to determine how small of tears could be detected with this imaging technique. METHODS: Seven supraspinatus tendons excised from embalmed cadavers were used. Three different sizes of partial-thickness bursal-sided tears (1, 3, and 5 mm(3)) were created in each specimen. The intersection of two co-focused ultrasound beams of slightly different frequency was swept across the intended imaging area. The acoustic emission data were collected and used to form and display a vibro-acoustography image of the tendon. Vibro-acoustography images were read by two orthopedic surgeons. RESULTS: The rotator cuff tear could be detected by vibro-acoustography in all specimens. The diagnostic concordance rate was 90.5 % and the kappa coefficient value was 0.88, which resulted in a high concordance. The diagnostic concordance rate for the 1 mm tear was 71.3 %, which was low concordance (κ = 0.481), whereas that for the 3 and 5 mm tears was 100 %. CONCLUSIONS: We were able to detect a 3-mm tear by using vibro-acoustography. There is a possibility that this new imaging technique could become a useful imaging tool for the diagnosis of small partial-thickness rotator cuff tears.


Assuntos
Técnicas de Imagem por Elasticidade , Lesões do Manguito Rotador , Manguito Rotador/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Cadáver , Humanos , Pessoa de Meia-Idade
10.
Artigo em Inglês | MEDLINE | ID: mdl-26067038

RESUMO

Tissues such as skeletal muscle and kidneys have well-defined structure that affects the measurements of mechanical properties. As an approach to characterize the material properties of these tissues, different groups have assumed that they are transversely isotropic (TI) and measure the shear wave velocity as it varies with angle with respect to the structural architecture of the organ. To refine measurements in these organs, it is desirable to have tissue-mimicking phantoms that exhibit similar anisotropic characteristics. Some approaches involve embedding fibers into a material matrix. However, if a homogeneous solid is under compression due to a static stress, an acoustoelastic effect can manifest that makes the measured wave velocities change with the compression stress. We propose to exploit this characteristic to demonstrate that stressed tissue mimicking phantoms can be characterized as a TI material. We tested six phantoms made with different concentrations of gelatin and agar. Stress was applied by the weight of a water container centered on top of a plate on top of the phantom. A linear array transducer and a V-1 Verasonics system were used to induce and measure shear waves in the phantoms. The shear wave motion was measured using a compound plane wave imaging technique. Autocorrelation was applied to the received in-phase/quadrature data. The shear wave velocity, c, was estimated using a Radon transform method. The transducer was mounted on a rotating stage so measurements were made every 10° over a range of 0° to 360°, where the stress is applied along 0° to 180° direction. The shear moduli were estimated. A TI model was fit to the data and the fractional anisotropy was evaluated. This approach can be used to explore many configurations of transverse isotropy with the same phantom, simply by applying stress to the tissue-mimicking phantom.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Modelos Biológicos , Imagens de Fantasmas , Ágar/química , Técnicas de Imagem por Elasticidade/métodos , Gelatina/química
11.
Ultrasound Med Biol ; 40(12): 2819-29, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25438862

RESUMO

We previously investigated the application of a novel imaging modality, vibro-acoustography (VA), using an annular confocal transducer (confocal VA) integrated into a clinical prone stereotactic mammography system, to detect various breast abnormalities. To shorten the scanning time and provide improved coverage of the breast, we have evolved our imaging system by implementing VA on a clinical ultrasound scanner equipped with a ''quasi-2-D'' array transducer. We call this technique ''quasi-2-D vibro-acoustography'' (Q2-DVA). A clinical ultrasound scanner (GE Vivid 7) was modified to perform both ultrasound imaging and VAusing an array transducer consisting of a matrix of 12 rows by 70 columns of ultrasound elements. The newly designed system was used to perform VA on patients with either benign or cancerous lesions. Our results indicate that benign and malignant solid breast lesions were easily detected using our newly modified VA system. It was also possible to detect microcalcifications within the breast. Our results suggest that with further development, Q2-DVA could provide high-resolution diagnostic information in the clinical setting and may be used either as a stand-alone or as a complementary tool in support of other clinical imaging modalities.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/instrumentação , Aumento da Imagem/instrumentação , Transdutores , Ultrassonografia Mamária/instrumentação , Adulto , Idoso , Técnicas de Imagem por Elasticidade/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
12.
Phys Med Biol ; 59(24): 7735-52, 2014 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-25419697

RESUMO

Ultrasound radiation force-based methods can quantitatively evaluate tissue viscoelastic material properties. One of the limitations of the current methods is neglecting the inherent anisotropy nature of certain tissues. To explore the phenomenon of anisotropy in a laboratory setting, we created two phantom designs incorporating fibrous and fishing line material with preferential orientations. Four phantoms were made in a cube-shaped mold; both designs were arranged in multiple layers and embedded in porcine gelatin using two different concentrations (8%, 14%). An excised sample of pork tenderloin was also studied. Measurements were made in the phantoms and the pork muscle at different angles by rotating the phantom with respect to the transducer, where 0° and 180° were defined along the fibers, and 90° and 270° across the fibers. Shear waves were generated and measured by a Verasonics ultrasound system equipped with a linear array transducer. For the fibrous phantom, the mean and standard deviations of the shear wave speeds along (0°) and across the fibers (90°) with 8% gelatin were 3.60  ±  0.03 and 3.18  ±  0.12 m s(-1) and with 14% gelatin were 4.10  ±  0.11 and 3.90  ±  0.02 m s(-1). For the fishing line material phantom, the mean and standard deviations of the shear wave speeds along (0°) and across the fibers (90°) with 8% gelatin were 2.86  ±  0.20 and 2.44  ±  0.24 m s(-1) and with 14% gelatin were 3.40  ±  0.09 and 2.84  ±  0.14 m s(-1). For the pork muscle, the mean and standard deviations of the shear wave speeds along the fibers (0°) at two different locations were 3.83  ±  0.16 and 3.86  ±  0.12 m s(-1) and across the fibers (90°) were 2.73  ±  0.18 and 2.70  ±  0.16 m s(-1), respectively. The fibrous and fishing line gelatin-based phantoms exhibited anisotropy that resembles that observed in the pork muscle.


Assuntos
Materiais Biomiméticos/química , Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Músculo Esquelético/diagnóstico por imagem , Imagens de Fantasmas , Algoritmos , Animais , Óleo de Rícino/química , Gelatina/química , Músculo Esquelético/efeitos da radiação , Resistência ao Cisalhamento , Suínos , Ultrassom , Viscosidade
13.
Med Phys ; 41(9): 092902, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25186418

RESUMO

PURPOSE: Effective permanent prostate brachytherapy (PPB) requires precise placement of radioactive seeds in and around the prostate. The impetus for this research is to examine a new ultrasound-based imaging modality, vibro-acoustography (VA), which may serve to provide a high rate of PPB seed detection while also effecting enhanced prostate imaging. The authors investigate the ability of VA, implemented on a clinical ultrasound (US) scanner and equipped with a quasi-2D (Q2D) array US transducer, to detect and localize PPB seeds in excised prostate specimens. METHODS: Nonradioactive brachytherapy seeds were implanted into four excised cadaver prostates. A clinical US scanner equipped with a Q2D array US transducer was customized to acquire both US and C-scan VA images at various depths. The VA images were then used to detect and localize the implanted seeds in prostate tissue. To validate the VA results, computed tomography (CT) images of the same tissue samples were obtained to serve as the reference by which to evaluate the performance of VA in PPB seed detection. RESULTS: The results indicate that VA is capable of accurately identifying the presence and distribution of PPB seeds with a high imaging contrast. Moreover, a large ratio of the PPB seeds implanted into prostate tissue samples could be detected through acquired VA images. Using CT-based seed identification as the standard, VA was capable of detecting 74%-92% of the implanted seeds. Additionally, the angular independency of VA in detecting PPB seeds was demonstrated through a well-controlled phantom experiment. CONCLUSIONS: Q2DVA detected a substantial portion of the seeds by using a 2D array US transducer in excised prostate tissue specimens. While VA has inherent advantages associated with conventional US imaging, it has the additional advantage of permitting detection of PPB seeds independent of their orientation. These results suggest the potential of VA as a method for PPB imaging that ultimately may allow US-based real-time intraoperative dosimetry.


Assuntos
Braquiterapia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Estudos de Viabilidade , Humanos , Masculino , Projetos Piloto , Próstata/diagnóstico por imagem , Tomografia Computadorizada por Raios X
14.
IEEE Trans Med Imaging ; 33(11): 2140-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25020066

RESUMO

Shear wave speed can be used to assess tissue elasticity, which is associated with tissue health. Ultrasound shear wave elastography techniques based on measuring the propagation speed of the shear waves induced by acoustic radiation force are becoming promising alternatives to biopsy in liver fibrosis staging. However, shear waves generated by such methods are typically very weak. Therefore, the penetration may become problematic, especially for overweight or obese patients. In this study, we developed a new method called external vibration multi-directional ultrasound shearwave elastography (EVMUSE), in which external vibration from a loudspeaker was used to generate a multi-directional shear wave field. A directional filter was then applied to separate the complex shear wave field into several shear wave fields propagating in different directions. A 2-D shear wave speed map was reconstructed from each individual shear wave field, and a final 2-D shear wave speed map was constructed by compounding these individual wave speed maps. The method was validated using two homogeneous phantoms and one multi-purpose tissue-mimicking phantom. Ten patients undergoing liver magnetic resonance elastography (MRE) were also studied with EVMUSE to compare results between the two methods. Phantom results showed EVMUSE was able to quantify tissue elasticity accurately with good penetration. In vivo EVMUSE results were well correlated with MRE results, indicating the promise of using EVMUSE for liver fibrosis staging.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
15.
Ultrasound Med Biol ; 40(8): 1785-95, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24814645

RESUMO

Our aims were (i) to compare in vivo measurements of myocardial elasticity by shear wave dispersion ultrasound vibrometry (SDUV) with those by the conventional pressure-segment length method, and (ii) to quantify changes in myocardial viscoelasticity during systole and diastole after reperfused acute myocardial infarction. The shear elastic modulus (µ1) and viscous coefficient (µ2) of left ventricular myocardium were measured by SDUV in 10 pigs. Young's elastic modulus was independently measured by the pressure-segment length method. Measurements made with the SDUV and pressure-segment length methods were strongly correlated. At reperfusion, µ1 and µ2 in end-diastole were increased. Less consistent changes were found during systole. In all animals, µ1 increased linearly with left ventricular pressure developed during systole. Preliminary results suggest that µ1 is preload dependent. This is the first study to validate in vivo measurements of myocardial elasticity by a shear wave method. In this animal model, the alterations in myocardial viscoelasticity after a myocardial infarction were most consistently detected during diastole.


Assuntos
Módulo de Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Suínos , Viscosidade
16.
IEEE Trans Med Imaging ; 32(12): 2299-310, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24021638

RESUMO

Ultrasound tissue harmonic imaging is widely used to improve ultrasound B-mode imaging quality thanks to its effectiveness in suppressing imaging artifacts associated with ultrasound reverberation, phase aberration, and clutter noise. In ultrasound shear wave elastography (SWE), because the shear wave motion signal is extracted from the ultrasound signal, these noise sources can significantly deteriorate the shear wave motion tracking process and consequently result in noisy and biased shear wave motion detection. This situation is exacerbated in in vivo SWE applications such as heart, liver, and kidney. This paper, therefore, investigated the possibility of implementing harmonic imaging, specifically pulse-inversion harmonic imaging, in shear wave tracking, with the hypothesis that harmonic imaging can improve shear wave motion detection based on the same principles that apply to general harmonic B-mode imaging. We first designed an experiment with a gelatin phantom covered by an excised piece of pork belly and show that harmonic imaging can significantly improve shear wave motion detection by producing less underestimated shear wave motion and more consistent shear wave speed measurements than fundamental imaging. Then, a transthoracic heart experiment on a freshly sacrificed pig showed that harmonic imaging could robustly track the shear wave motion and give consistent shear wave speed measurements of the left ventricular myocardium while fundamental imaging could not. Finally, an in vivo transthoracic study of seven healthy volunteers showed that the proposed harmonic imaging tracking sequence could provide consistent estimates of the left ventricular myocardium stiffness in end-diastole with a general success rate of 80% and a success rate of 93.3% when excluding the subject with Body Mass Index higher than 25. These promising results indicate that pulse-inversion harmonic imaging can significantly improve shear wave motion tracking and thus potentially facilitate more robust assessment of tissue elasticity by SWE.

17.
Clinics (Sao Paulo) ; 68(4): 463-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23778334

RESUMO

OBJECTIVES: This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS: A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system. RESULTS: The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements. CONCLUSION: Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications.


Assuntos
Artroplastia de Quadril , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Humanos , Imageamento Tridimensional , Ilustração Médica , Imagens de Fantasmas , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Propriedades de Superfície
18.
Clinics ; 68(4): 463-468, abr. 2013. graf
Artigo em Inglês | LILACS | ID: lil-674233

RESUMO

OBJECTIVES: This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS: A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system. RESULTS: The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements. CONCLUSION: Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications. .


Assuntos
Humanos , Artroplastia de Quadril , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Imageamento Tridimensional , Ilustração Médica , Imagens de Fantasmas , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Propriedades de Superfície
19.
BMC Med Imaging ; 13: 12, 2013 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-23530993

RESUMO

BACKGROUND: The purpose of this study was to evaluate the utility of a noninvasive ultrasound-based method, vibro-acoustography (VA), for thyroid imaging and determine the feasibility and challenges of VA in detecting nodules in thyroid. METHODS: Our study included two parts. First, in an in vitro study, experiments were conducted on a number of excised thyroid specimens randomly taken from autopsy. Three types of images were acquired from most of the specimens: X-ray, B-mode ultrasound, and vibro-acoustography. The second and main part of the study includes results from performing VA and B-mode ultrasound imaging on 24 human subjects with thyroid nodules. The results were evaluated and compared qualitatively. RESULTS: In vitro vibro-acoustography images displayed soft tissue structures, microcalcifications, cysts and nodules with high contrast and no speckle. In this group, all of US proven nodules and all of X-ray proven calcifications of thyroid tissues were detected by VA. In vivo results showed 100% of US proven calcifications and 91% of the US detected nodules were identified by VA, however, some artifacts were present in some cases. CONCLUSIONS: In vitro and in vivo VA images show promising results for delineating the detailed structure of the thyroid, finding nodules and in particular calcifications with greater clarity compare to US. Our findings suggest that, with further development, VA may be a suitable imaging modality for clinical thyroid imaging.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Med Phys ; 40(2): 022902, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23387773

RESUMO

PURPOSE: To evaluate the potential of the imaging modality vibro-acoustography (VA) for imaging of the prostate. METHODS: Excised cadaver prostate specimens were embedded in tissue mimicking gel to simulate the properties of surrounding soft tissues. The samples were imaged at various depths using a laboratory prototyped VA imaging system. The recorded signals were used for offline processing and image reconstruction. In a selected subgroup of tissue samples, conventional ultrasound (B-mode) and x-ray imaging were performed for further analysis, evaluation, and validation of the VA images. RESULTS: The imaging results of prostate tissue samples indicate the capability of VA imaging to detect prostatic nodules and lesions. In the prostate sample with an adenocarcinoma, the lesion appears with a clear contrast with respect to its surrounding tissue. The VA images could also identify the presence of calcifications deep inside the prostate tissue. Further, quantifications of the imaging results demonstrate that VA imaging has higher sensitivity to detect the calcifications compared to conventional ultrasound imaging. VA is also capable of visualizing prostatic tissue structures and in some cases can identify the anatomical zones. More specifically, the observed higher texture level in peripheral zones demonstrates the ability of VA to differentiate between prostatic anatomical zones. CONCLUSIONS: Imaging results of ex vivo prostate tissues, reveals the potency of VA as a promising tool to detect abnormalities, delineate tissue structures and anatomical zones, and locate calcifications. The results of this pilot study suggest that in vivo VA imaging of the prostate may be of clinical utility.


Assuntos
Próstata/diagnóstico por imagem , Próstata/patologia , Ultrassonografia/métodos , Vibração , Calcinose/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Próstata/metabolismo , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Ultrassonografia/instrumentação