Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Injury ; 53(8): 2734-2740, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35710595

RESUMO

BACKGROUND: Cannulated screws are often used in the management of open lower extremity fractures. These fractures exhibit broad contamination profiles, necessitating empirical Gram-positive and Gram-negative antibiotic coverage. To ensure full antibiotic protection of the cannulated screw and the bone tissue, it is generally accepted that target tissue antibiotic concentrations, as a minimum, reach and remain above relevant epidemiological cut-off minimal inhibitory concentrations (T>MIC) for a sufficient amount of time. METHODS: 8 female pigs were included. Microdialysis catheters were placed in the internal dead space of a cannulated screw placed in tibial cancellous bone, in tibial cancellous bone adjacent to the screw (mean distance to the screw: 3 mm), and in cancellous bone on the contralateral tibia. Following single-dose simultaneous intravenous administrations of vancomycin (1000 mg) and meropenem (1000 mg), microdialysates and plasma were dynamically sampled over 8 h. The applied MIC targets ranged from 1 to 4 µg/mL for vancomycin and 0.125-2 µg/mL for meropenem RESULTS: For both drugs, and for all MIC targets investigated (except for the high vancomycin target: 4 µg/mL), the internal dead space of the cannulated screw had the shortest T>MIC. At the low MIC targets T>MIC ranged between 88 and 449 min across sampling sites for vancomycin (1 µg/mL), and 148-406 min for meropenem (0.125 µg/mL). For the high MIC targets, T>MIC ranged between 3 and 446 min for vancomycin (4 µg/mL) and 17-181 min for meropenem (2 µg/mL). Vancomycin displayed longer T>MIC (2 and 4 µg/mL), higher area under the concentration time curve (AUC0-last) and peak drug concentration in the proximal tibial cancellous bone without a screw nearby. For meropenem, only the cancellous bone AUC0-last was significantly higher on the side with no screw. CONCLUSION: We found short T>MIC, particularly for the high MIC targets for vancomycin and meropenem, both inside the cannulated screw and in cancellous bone adjacent to the screw. The presence of a cannulated screw impaired the penetration of especially vancomycin into cancellous bone adjacent to the screw. More aggressive or different vancomycin and meropenem approaches may be considered to encompass contaminating differences and to ensure a theoretically more sufficient antibiotic protection of cannulated screws when used in the management of open lower extremity fractures.


Assuntos
Osso Esponjoso , Vancomicina , Animais , Antibacterianos/farmacologia , Feminino , Meropeném/farmacologia , Microdiálise , Suínos , Vancomicina/farmacologia
2.
Bone Joint Res ; 11(2): 112-120, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35176868

RESUMO

AIMS: Prompt and sufficient broad-spectrum empirical antibiotic treatment is key to preventing infection following open tibial fractures. Succeeding co-administration, we dynamically assessed the time for which vancomycin and meropenem concentrations were above relevant epidemiological cut-off (ECOFF) minimal inhibitory concentrations (T > MIC) in tibial compartments for the bacteria most frequently encountered in open fractures. Low and high MIC targets were applied: 1 and 4 µg/ml for vancomycin, and 0.125 and 2 µg/ml for meropenem. METHODS: Eight pigs received a single dose of 1,000 mg vancomycin and 1,000 mg meropenem simultaneously over 100 minutes and 10 minutes, respectively. Microdialysis catheters were placed for sampling over eight hours in tibial cancellous bone, cortical bone, and adjacent subcutaneous adipose tissue. Venous blood samples were collected as references. RESULTS: Across the targeted ECOFF values, vancomycin displayed longer T > MIC in all the investigated compartments in comparison to meropenem. For both drugs, cortical bone exhibited the shortest T > MIC. For the low MIC targets and across compartments, mean T > MIC ranged between 208 and 449 minutes (46% to 100%) for vancomycin and between 189 and 406 minutes (42% to 90%) for meropenem. For the high MIC targets, mean T > MIC ranged between 30 and 446 minutes (7% to 99%) for vancomycin and between 45 and 181 minutes (10% to 40%) for meropenem. CONCLUSION: The differences in the T > MIC between the low and high targets illustrate how the interpretation of these results is highly susceptible to the defined MIC target. To encompass any trauma, contamination, or individual tissue differences, a more aggressive dosing approach may be considered to achieve longer T > MIC in all the exposed tissues, and thereby lower the risk of acquiring an infection after open tibial fractures. Cite this article: Bone Joint Res 2022;11(2):112-120.

3.
World J Gastrointest Pathophysiol ; 12(1): 1-13, 2021 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-33585069

RESUMO

BACKGROUND: Anastomotic leakage is a serious complication following gastrointestinal surgery and is associated with increased morbidity and mortality. The incidence of anastomotic leakage is determined by anatomy and is reported to be between 4%-33% for colon anastomosis and 1%-3% for small intestine anastomosis. The etiology of anastomotic leakage of the intestine has been divided into three main factors: healing disturbances, communication between intra- and extra-luminal compartments, and infection. All three factors interact, and one factor will inevitably lead to the other two factors resulting in tissue ischemia, tissue necrosis, and anastomotic leakage. AIM: To evaluate ischemic metabolites and cefuroxime concentrations in both anastomosis and non-anastomosis ileum and colon in a porcine model. METHODS: Eight healthy female pigs (Danish Landrace breed, weight 58-62 kg) were included in this study. Microdialysis catheters were placed for sampling of ischemic metabolites (glucose, lactate, glycerol, and pyruvate) and cefuroxime concentrations in both anastomosis and non-anastomosis ileum and colon. Cefuroxime 1.5 g was administered as an intravenous infusion over 15 min. Subsequently, dialysates and blood samples were collected over 8 h and the ischemic metabolites and cefuroxime concentrations were quantified in all samples. The concentrations of glucose, lactate, glycerol and pyruvate were determined using the CMA 600 Microdialysis Analyzer with Reagent Set A (M Dialysis AB, Sweden), and the concentrations of cefuroxime and meropenem were quantified using a validated ultra-high-performance liquid chromatography assay. RESULTS: Only the colon anastomosis induced mean ischemic lactate/pyruvate ratios above 25 (ischemic cut-off) throughout the entire sampling interval, and simultaneously decreased glucose concentrations. The mean time for which cefuroxime concentrations were maintained above the clinical breakpoint minimal inhibitory concentration for Escherichia coli (8 µg/mL) ranged between 116-128 min across all the investigated compartments, and was similar between the anastomosis and non-anastomosis ileum and colon. For all pigs and in all the investigated compartments, a cefuroxime concentration of 8 µg/mL was reached within 10 min after administration. When comparing the pharmacokinetic parameters between the anastomosis and non-anastomosis sites for both ileum and colon, only colon Tmax and half-life differed between anastomosis and non-anastomosis (P < 0.03). Incomplete tissue penetrations were found in all tissues except for the non-anastomosis colon. CONCLUSION: Administering 1.5 g cefuroxime 10 min prior to intestine surgery seems sufficient, and effective concentrations are sustained for approximately 2 h. Only colon anastomosis was locally vulnerable to ischemia.

4.
J Orthop ; 18: 138-142, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32021020

RESUMO

Two-stage revision with 'StageOne™ Select Hip Cement Spacer' is used as treatment of periprosthetic hip joint infection. The aim is to evaluate complications and restoration the joint with the StageOne Select Spacer. From 2013 to 2018 twenty-nine StageOne Select Spacers was inserted. Data was obtained through medical records and radiographs. 3.5% dislocated the spacer, 6.9% sustained a femoral fracture, 6.9% got reinfected and 6.9% failed to control the infection. Leg length discrepancy was 1.5 mm (-4,25-5.25) and offset discrepancy was 4 mm (-0.5-9). The spacer shows promising results with a low reinfection and dislocation rate and allowance of restoration of the joint.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...