1.
Sud Med Ekspert ; 44(6): 33-5, 2001.
Artigo em Russo | MEDLINE | ID: mdl-11871330

RESUMO

A gas chromatographic method has been developed for measurement of carbon monoxide in cadaveric blood on a chromatographer with thermal conductivity detector and air oxygen as the internal standard. The error of the method is no more than 4% with the mean quadratic deviation +/- 0.18-0.33 min. The method was studied on 10 model and 30 expert blood samples. Putrefactive products did not influence the accuracy of analysis.


Assuntos
Cadáver , Monóxido de Carbono/sangue , Cromatografia Gasosa/métodos , Eletroquímica , Humanos , Padrões de Referência