Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Cardiovasc Imaging ; 32(8): 1171-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27168076

RESUMO

Contradiction exists on the incremental value of two-dimensional (2D) and 3D transoesophageal echocardiography (TOE) over 2D transthoracic echocardiography (TTE) for the detection of mitral valve (MV) prolapse in readers with different echocardiographic experience. Twenty patients and five healthy persons were retrospectively identified who had undergone 2D-TTE, 2D-TOE and 3D-TOE. Fifteen (75 %) patients had surgical evidence of prolapse of the posterior MV leaflet and five patients (25 %) had a dilated MV annulus without prolapse. Three reader groups with different echocardiographic expertise (novice, trainees, cardiologists) scored thus in total 675 posterior scallops. Overall there was an improvement in agreement and Kappa values from novice to trainees to cardiologists. Diagnostic accuracies of 2D-TOE were higher than those of 2D-TTE mainly in novice readers. The incremental value of 3D-TOE over 2D-TOE was mainly seen in specificities. Time to diagnosis was dramatically reduced from 2D to 3D-TEE in all reader groups (all P < 0.001). 3D-TOE also improved the agreement (+12 to +16 %) and Kappa values (+0.14 to +0.21) in all reader groups for the exact description of P2 prolapse. Differences between readers with variable experience in determining the precise localization and extent of the prolapsing posterior MV scallops exist in particular in 2D-TTE analysis. 3D-TOE analysis was extremely fast compared to the 2D analysis methods and showed the best diagnostic accuracy (mainly driven by specificity) with identification of P1 and P3 prolapse still improving from novice to trainees to cardiologists and provided optimal description of P2 prolapse extent.


Assuntos
Competência Clínica , Ecocardiografia Tridimensional , Prolapso da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Diagnóstico Tardio , Feminino , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo
2.
Echocardiography ; 30(5): 497-504, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23305528

RESUMO

OBJECTIVES/BACKGROUND: Congenital aortic stenosis (AS) is the most common obstructive left heart lesion in the young adult population and often complicated by aortic dilatation. Our objective was to evaluate accuracy of aortic imaging with transthoracic echocardiography (TTE) compared with cardiac magnetic resonance (CMR). METHODS: Aortic diameters were measured at 4 levels by CMR and TTE. Agreement and concordance were assessed by Pearson's correlation and Bland-Altman analysis. RESULTS: Fifty-nine patients (age 33 ± 8 years; 66% male) with congenital AS and a bicuspid aortic valve (BAV) were included. Aortic diameters were generally smaller with TTE than with CMR. The best correlation was found at the level of the sinotubular junction (R(2) = 0.78) with a bias of 1.46 mm (limits of agreement: -5.47 to +8.39 mm). In patients with an aortic aneurysm >40 mm (n = 29) the correlation and agreement between TTE and CMR were found to be less good when compared with patients with normal aortic diameters, especially at the level of the proximal ascending aorta. The correlation and agreement between both imaging modalities were better in patients with type 1 BAV compared with type 2 BAV. Intra- and interobserver variability was smaller with CMR (1.8-5.9%) compared with TTE (6.9-15.0%). CONCLUSIONS: CMR was found to be superior to TTE for imaging of the aorta in patients with congenital AS, especially at the level of the proximal ascending aorta when an aortic aneurysm is present. Therefore, ideally CMR should be performed at least once to ensure an ascending aortic aneurysm is not missed.


Assuntos
Aorta/diagnóstico por imagem , Aorta/patologia , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Aneurisma Aórtico/diagnóstico , Estudos de Coortes , Diagnóstico por Imagem/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...