Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Interv Neuroradiol ; 29(6): 637-647, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36047782

RESUMO

BACKGROUND: Mechanical thrombectomy is the standard treatment for acute ischemic stroke in patients with large vessel occlusion and can be performed up to 24h after symptom onset. Despite high recanalization rates, embolism in new territories has been reported in 8.6% of the cases. Causes for this could be clot abruption during stent retrieval into the smaller opening of a standard distal access catheter, and antegrade blood flow via collaterals despite proximal balloon protection. A funnel-shaped tip with a larger internal diameter was developed to increase the rate of first-pass recanalization and to improve the safety and efficacy of mechanical thrombectomy. METHODS: This in vitro study compared the efficacy of a funnel-shaped tip with a standard tip in combination with different clot compositions. Mechanical thrombectomy was performed 80 times for each tip, using two stent retrievers (Trevo XP ProVue 3/20 mm, 4/20 mm) and four different clot types (hard vs. soft clots, 0-24h vs. 72h aged clots). RESULTS: Significantly higher first-pass recanalization rates (mTICI 3) were observed for the funnel-shaped tip, 70.0% versus 30.0% for the standard tip (absolute difference, 32; relative difference 57.1%; P < .001), regardless of the clot type and stent retriever. Recanalization could be increased using harder Chandler loop clots versus softer statically generated clots, as well as 0-24h versus 72h aged clots, respectively. CONCLUSION: The funnel-shaped tip achieved higher first-pass recanalization rates than the smaller standard tip and lower rates of clot abruption at the tip. Clot compositions and aging times impacted recanalization rates.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Trombose , Humanos , Idoso , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Resultado do Tratamento , Trombose/cirurgia , Catéteres , Stents , Técnicas In Vitro
2.
PLoS One ; 17(10): e0263983, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36227879

RESUMO

BACKGROUND: Filament perforation is a widely-used method to induce subarachnoid hemorrhage (SAH) in mice. Whereas the perforation site has been assumed to be in the branching of middle cerebral artery (MCA) and anterior cerebral artery (ACA), we recently observed more proximal perforations. METHODS: Filament perforation was performed in CD1- (n = 10) and C57Bl/6N-mice (n = 9) ex vivo. The filament was left in place and the perforation site was microscopically assessed. Digital subtraction angiography (DSA) was performed in CD1- (n = 9) and C57Bl/6J-mice (n = 29) and anatomical differences of the internal carotid artery (ICA) were determined. RESULTS: Whereas in C57Bl/6N-mice perforation occurred in the proximal intracranial ICA in 89% (n = 8), in CD1-mice the perforation site was in the proximal ICA in 50% (n = 5), in the branching between MCA and ACA in 40% (n = 4), and in the proximal ACA in 10% (n = 1). DSA revealed a stronger angulation (p<0.001) of the ICA in CD1-mice (163.5±2.81°) compared to C57Bl/6J-mice (124.5±5.49°). Body weight and ICA-angle showed no significant correlation in C57Bl/6J- (r = -0.06, pweight/angle = 0.757) and CD1-mice (r = -0.468, pweight/angle = 0.242). CONCLUSION: Filament perforation in mice occurs not only at the hitherto presumed branching between MCA and ACA, but seems to depend on mouse strain and anatomy as the proximal intracranial ICA may also be perforated frequently.


Assuntos
Aneurisma Intracraniano , Hemorragia Subaracnóidea , Angiografia Digital , Animais , Artéria Cerebral Anterior/diagnóstico por imagem , Angiografia Cerebral , Camundongos , Camundongos Endogâmicos C57BL , Artéria Cerebral Média/diagnóstico por imagem , Hemorragia Subaracnóidea/diagnóstico por imagem
3.
Sci Rep ; 10(1): 633, 2020 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-31959777

RESUMO

One limitation of mechanical thrombectomy (MT) is clot migration during procedure. This might be caused by abruption of the trapped thrombus at the distal access catheter (DAC) tip during stent-retriever retraction due to the cylindrical shaped tip of the DAC. Aiming to solve this problem, this study evaluates the proof-of-concept of a new designed funnel-shaped tip, in an experimental in vitro setting. Two catheter models, one with a funnel-shaped tip and one with a cylindrical-shaped tip, were compared in an experimental setup. For MT a self-made vessel model and thrombi generated from pig's blood were used. MT was performed 20 times for each device using two different stent-retrievers, 10 times respectively. For the funnel-shaped model: for both stent-retrievers (Trevo XP ProVue 3/20 mm; Trevo XP ProVue 4/20 mm) MT was successful at first pass in 9/10 (90%), respectively. For the cylindrical-shaped model: MT was successful at first pass in 5/10 (50%) with the smaller stent-retriever and in 6/10 (60%) with the larger stent-retriever. The experiments show a better recanalization rate for funnel-shaped tips, than for cylindrical-shaped tips. These results are indicating a good feasibility for this new approach, thus the development of a prototype catheter seems reasonable.


Assuntos
Catéteres , Desenho de Equipamento , Trombectomia/instrumentação , Trombose/prevenção & controle , Animais , Técnicas In Vitro , Suínos
4.
J Cereb Blood Flow Metab ; 40(11): 2265-2277, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31752586

RESUMO

Longitudinal in vivo imaging studies characterizing subarachnoid hemorrhage (SAH)-induced large artery vasospasm (LAV) in mice are lacking. We developed a SAH-scoring system to assess SAH severity in mice using micro CT and longitudinally analysed LAV by intravenous digital subtraction angiography (i.v. DSA). Thirty female C57Bl/6J-mice (7 sham, 23 SAH) were implanted with central venous ports for repetitive contrast agent administration. SAH was induced by filament perforation. LAV was assessed up to 14 days after induction of SAH by i.v. DSA. SAH-score and neuroscore showed a highly significant positive correlation (rsp = 0.803, p < 0.001). SAH-score and survival showed a negative significant correlation (rsp = -0.71, p < 0.001). LAV peaked between days 3-5 and normalized on days 7-15. Most severe LAV was observed in the internal carotid (Δmax = 30.5%, p < 0.001), anterior cerebral (Δmax = 21.2%, p = 0.014), middle cerebral (Δmax = 28.16%, p < 0.001) and basilar artery (Δmax = 23.49%, p < 0.001). Cerebral perfusion on day 5 correlated negatively with survival time (rPe = -0.54, p = 0.04). Arterial diameter of the left MCA correlated negatively with cerebral perfusion on day 3 (rPe = -0.72, p = 0.005). In addition, pseudoaneurysms arising from the filament perforation site were visualized in three mice using i.v. DSA. Thus, micro-CT and DSA are valuable tools to assess SAH severity and to longitudinally monitor LAV in living mice.


Assuntos
Angiografia Cerebral , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiopatologia , Hemorragia Subaracnóidea/diagnóstico , Vasoespasmo Intracraniano/diagnóstico , Microtomografia por Raio-X , Animais , Biomarcadores , Biópsia , Angiografia Cerebral/métodos , Modelos Animais de Doenças , Feminino , Imuno-Histoquímica , Camundongos , Índice de Gravidade de Doença , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/mortalidade , Microtomografia por Raio-X/métodos
5.
Sci Rep ; 9(1): 15489, 2019 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-31664066

RESUMO

A long-standing hypothesis in radiotherapy is that intensity-modulated radiotherapy (IMRT) increases the risk of second cancer due to low-dose exposure of large volumes of normal tissue. Therefore, young patients are still treated with conventional techniques rather than with modern IMRT. We challenged this hypothesis in first-of-its-kind experiments using an animal model. Cancer-prone Tp53+/C273X knockout rats received mediastinal irradiation with 3 × 5 or 3 × 8 Gy using volumetric-modulated arc therapy (VMAT, an advanced IMRT) or conventional anterior-posterior/posterior-anterior (AP/PA) beams using non-irradiated rats as controls (n = 15/group, ntotal = 90). Tumors were assigned to volumes receiving 90-107%, 50-90%, 5-50%, and <5% of the target dose and characterized by histology and loss-of-heterozygosity (LOH). Irradiated rats predominantly developed lymphomas and sarcomas in areas receiving 50-107% (n = 26) rather than 5-50% (n = 7) of the target dose. Latency was significantly shortened only after 3 × 8 Gy vs. controls (p < 0.0001). The frequency (14/28 vs. 19/29; p = 0.29) and latency (218 vs. 189 days; p = 0.17) of radiation-associated tumors were similar after VMAT vs. AP/PA. LOH was strongly associated with sarcoma but not with treatment. The results do not support the hypothesis that IMRT increases the risk of second cancer. Thus the current practice of withholding dose-sparing IMRT from young patients may need to be re-evaluated.


Assuntos
Modelos Animais de Doenças , Mediastino/efeitos da radiação , Neoplasias Induzidas por Radiação/epidemiologia , Radioterapia de Intensidade Modulada/métodos , Animais , Feminino , Masculino , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Ratos , Ratos Transgênicos , Fatores de Risco , Proteína Supressora de Tumor p53/genética
6.
PLoS One ; 14(8): e0222010, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31465489

RESUMO

For endovascular research pigs are an established animal model. However, experiences regarding analyses of platelet inhibition in pigs using the Multiplate® Analyzer are limited. The aims of the present study were to investigate if (1) the Multiplate® Analyzer is a suitable method for examination of porcine platelet function using manufacturers' recommendations for human blood, and (2) platelet inhibition can be induced with acetylsalicylic acid (ASA) and clopidogrel in pigs reliably, and if (3) non-responders to one of the drug can be detected. Additionally we examined differences in (4) the effectiveness of ASA between oral administration and intravenous application, and (5) between domestic pigs (German Landrace; GL) and miniature pigs (MP). We investigated platelet function of 36 unmedicated pigs (GL n = 28; MP n = 8). In addition, 32 blood samples taken from medicated pigs (GL n = 15; MP n = 17) were analysed. Platelet inhibition was induced in four different ways: (1) 500 mg ASA intravenously (n = 11), (2) 500 mg ASA intravenously and 450 mg clopidogrel orally (n = 5), (3) 250 mg ASA orally (n = 11), (4) 250 mg ASA orally and 75 mg clopidogrel orally (n = 5). Results of the ASPI and ADP test of the Multiplate® Analyzer subtests in unmedicated and medicated pigs were in a comparable range to results known from humans. Application of ASA decreased the mean values of the ASPI test significantly regardless of the application method. Joined administration of ASA and clopidogrel also decreased the mean values of the ADP test significantly. Both, oral and intravenous administrations of ASA as well as oral administration of clopidogrel effectively inhibited platelet function in pigs. One pig did not respond to clopidogrel. We found no differences between domestic and miniature pigs regarding reference values in unmedicated pigs and the effectiveness of ASA and clopidogrel.


Assuntos
Testes de Função Plaquetária/métodos , Animais , Aspirina/farmacologia , Plaquetas/efeitos dos fármacos , Plaquetas/imunologia , Plaquetas/metabolismo , Agregação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Antagonistas do Receptor Purinérgico P2Y/farmacologia , Suínos
7.
J Vis Exp ; (137)2018 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-30102288

RESUMO

Subarachnoid hemorrhage (SAH) is a subtype of hemorrhagic stroke. Cerebral vasospasm that occurs in the aftermath of the bleeding is an important factor determining patient outcome and is therefore frequently taken as a study endpoint. However, in small animal studies on SAH, quantification of cerebral vasospasm is a major challenge. Here, an ex vivo method is presented that allows quantification of volumes of entire vessel segments, which can be used as an objective measure to quantify cerebral vasospasm. In a first step, endovascular casting of the cerebral vasculature is performed using a radiopaque casting agent. Then, cross-sectional imaging data are acquired by micro computed tomography. The final step involves 3-dimensional reconstruction of the virtual vascular tree, followed by an algorithm to calculate center lines and volumes of the selected vessel segments. The method resulted in a highly accurate virtual reconstruction of the cerebrovascular tree shown by a diameter-based comparison of anatomical samples with their virtual reconstructions. Compared with vessel diameters alone, the vessel volumes highlight the differences between vasospastic and non-vasospastic vessels shown in a series of SAH and sham-operated mice.


Assuntos
Hemorragia Subaracnóidea/diagnóstico , Vasoespasmo Intracraniano/diagnóstico , Microtomografia por Raio-X/métodos , Animais , Modelos Animais de Doenças , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL
8.
Clin Oral Investig ; 22(9): 3143-3157, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29524024

RESUMO

OBJECTIVE: Optical coherence tomography (OCT) is a clinical standard in ophthalmology. Currently, its application in dentistry is gaining increasing interest. In this study, we tested the possibility to use a modified commercially available spectral domain OCT (SD-OCT) to assess the layer thickness of orthodontic surface sealants. MATERIALS AND METHODS: Reference samples of surface sealants for calibration and repeatability testing were measured using a micrometer screw. SD-OCT measurements were compared with micro-CT and light microscopic analyses. After validating the calibration of the SD-OCT, surface sealant layer thickness after aging (thermo cycling) and simulation of professional tooth cleaning (PTC) was assessed using the SD-OCT on 45 extracted teeth assigned to three test groups (n = 15 each): Light Bond™ Sealant, Pro Seal®, and Opal® Seal. RESULTS: SD-OCT showed excellent repeatability and accuracy for measurements of surface sealant layer thickness. Compared with micro-CT, SD-OCT showed better accordance with the reference measurements. The analysis of surface sealants after thermo cycling and PTC revealed poor resistance of Light Bond after only aging and demonstrated substantial wear of all sealants after aging and PTC. CONCLUSION: Imaging using commercially available ophthalmic SD-OCT might represent a suitable non-invasive methodology for longitudinal assessments of surface sealant layer thickness in vitro and in vivo. CLINICAL RELEVANCE: SD-OCT might be a suitable non-invasive method for longitudinal assessments of surface sealant durability in clinical trials.


Assuntos
Selantes de Fossas e Fissuras/química , Tomografia de Coerência Óptica/instrumentação , Resinas Compostas , Humanos , Técnicas In Vitro , Teste de Materiais , Reprodutibilidade dos Testes , Cimentos de Resina , Propriedades de Superfície , Microtomografia por Raio-X
9.
PLoS One ; 12(12): e0189356, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29232698

RESUMO

PURPOSE: As result of the current demographic changes, osteoporosis and osteoporotic fractures are becoming an increasing social and economic burden. In this experimental study, extracorporeal shock wave therapy (ESWT), was evaluated as a treatment option for the improvement of osteoporotic fracture healing. METHODS: A well-established fracture model in the metaphyseal tibia in the osteoporotic rat was used. 132 animals were divided into 11 groups, with 12 animals each, consisting of one sham-operated group and 10 ovariectomized (osteoporotic) groups, of which 9 received ESWT treatment. Different energy flux intensities (0.15 mJ/mm2, 0.35 mJ/mm2, or 0.55 mJ/mm2) as well as different numbers of ESWT applications (once, three times, or five times throughout the 35-day healing period) were applied to the osteoporotic fractures. Fracture healing was investigated quantitatively and qualitatively using micro-CT imaging, quantitative real-time polymerase chain reaction (qRT-PCR) analysis, histomorphometric analysis and biomechanical analysis. RESULTS: The results of this study show a qualitative and quantitative improvement in the osteoporotic fracture healing under low-energy (energy flux intensity: 0,15 mJ/mm2) ESWT and with fewer treatment applications per healing period. CONCLUSION: In conclusion, low-energy ESWT seems to exhibit a beneficial effect on the healing of osteoporotic fractures, leading to improved biomechanical properties, enhanced callus-quantity and -quality, and an increase in the expression of bone specific transcription factors. The results suggest that low-energy ESWT, as main treatment or as adjunctive treatment in addition to a surgical intervention, may prove to be an effective, simple to use, and cost-efficient option for the qualitative and quantitative improvement of osteoporotic fracture healing.


Assuntos
Modelos Animais de Doenças , Tratamento por Ondas de Choque Extracorpóreas , Consolidação da Fratura , Fraturas por Osteoporose/fisiopatologia , Animais , Feminino , Ratos , Ratos Sprague-Dawley
10.
Eur J Radiol ; 93: 128-133, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28668406

RESUMO

PURPOSE: Main symptom of mucopolysaccharidosis type IVa (MPS IVa) is progressive systemic skeletal dysplasia. This is routinely monitored by cerebral and spinal MRI. The vascular system is generally not in the primary focus of interest. In our population of MPS IVa patients we observed vessel shape alterations of the vertebrobasilar arteries, which has not been described before. MATERIAL AND METHODS: MRI-datasets of 26 patients with MPS IVa acquired between 2008 and 2015 were eligible for retrospective analysis of the vertebrobasilar arteries. The vessel length and angle of the basilar artery (BA) and both vertebral arteries (VA) were analyzed. A deflection angle between 90° and 130° in the vessel course was defined as tortuosity, less than 90° as kinking. The results were compared to a matched control group of 23 patients not suffering from MPS. RESULTS: The deflection angle [°] of the VA and BA was significantly decreased in the majority (85%) of MPS IVa patients compared to the control group: BA 132±24 vs. 177±6, BA/VA transition 113±21 vs. 152±13, right VA 108±23 vs. 156±13, left VA 110± 22 vs. 157±14 (all p<0.005). Likewise, vessels of MPS IVa patients were significantly longer compared to the control group: BA 27±4 vs. 21±2, right VA 20±6 vs. 10±1, left VA 18±5 vs. 11±2 (all p<0.005). CONCLUSION: MPS IVa is associated with significantly increased tortuosity of vertebrobasilar arteries. Therefore the vascular system of MPS IVa patients should be monitored on routinely basis, as vessel shape alterations had been associated with dissections, leading to a higher risk of cerebrovascular events.


Assuntos
Artéria Basilar/fisiologia , Imageamento por Ressonância Magnética/métodos , Mucopolissacaridose IV/fisiopatologia , Artéria Vertebral/fisiologia , Humanos , Estudos Retrospectivos
11.
PLoS One ; 12(2): e0172010, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28199398

RESUMO

INTRODUCTION: Quantification of cerebral vasospasm after subarachnoid hemorrhage (SAH) is crucial in animal studies as well as clinical routine. We have developed a method for computer-based volumetric assessment of intracranial blood vessels from cross-sectional imaging data. Here we demonstrate the quantification of vasospasm from micro computed tomography (micro-CT) data in a rodent SAH model and the transferability of the volumetric approach to clinical data. METHODS: We obtained rodent data by performing an ex vivo micro-CT of murine brains after sham surgery or SAH by endovascular filament perforation on day 3 post hemorrhage. Clinical CT angiography (CTA) was performed for diagnostic reasons unrelated to this study. We digitally reconstructed and segmented intracranial vascular trees, followed by calculating volumes of defined vessel segments by standardized protocols using Amira® software. RESULTS: SAH animals demonstrated significantly smaller vessel diameters compared with sham (MCA: 134.4±26.9µm vs.165.0±18.7µm, p<0.05). We could highlight this difference by analyzing vessel volumes of a defined MCA-ICA segment (SAH: 0.044±0.017µl vs. sham: 0.07±0.006µl, p<0.001). Analysis of clinical CTA data allowed us to detect and volumetrically quantify vasospasm in a series of 5 SAH patients. Vessel diameters from digital reconstructions correlated well with those measured microscopically (rodent data, correlation coefficient 0.8, p<0.001), or angiographically (clinical data, 0.9, p<0.001). CONCLUSIONS: Our methodological approach provides accurate anatomical reconstructions of intracranial vessels from cross-sectional imaging data. It allows volumetric assessment of entire vessel segments, hereby highlighting vasospasm-induced changes objectively in a murine SAH model. This method could also be a helpful tool for analysis of clinical CTA.


Assuntos
Vasoespasmo Intracraniano/diagnóstico , Angiografia Digital , Animais , Encéfalo/diagnóstico por imagem , Vasos Coronários/fisiologia , Modelos Animais de Doenças , Feminino , Imageamento Tridimensional , Pressão Intracraniana/fisiologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Hemorragia Subaracnóidea/complicações , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/etiologia , Microtomografia por Raio-X
12.
PLoS One ; 11(11): e0165994, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27829015

RESUMO

PURPOSE: There is an increasing need for small animal in vivo imaging in murine orthotopic glioma models. Because dedicated small animal scanners are not available ubiquitously, the applicability of a clinical CT scanner for visualization and measurement of intracerebrally growing glioma xenografts in living mice was validated. MATERIALS AND METHODS: 2.5x106 U87MG cells were orthotopically implanted in NOD/SCID/ᵞc-/- mice (n = 9). Mice underwent contrast-enhanced (300 µl Iomeprol i.v.) imaging using a micro-CT (80 kV, 75 µAs, 360° rotation, 1,000 projections, scan time 33 s, resolution 40 x 40 x 53 µm) and a clinical CT scanner (4-row multislice detector; 120 kV, 150 mAs, slice thickness 0.5 mm, feed rotation 0.5 mm, resolution 98 x 98 x 500 µm). Mice were sacrificed and the brain was worked up histologically. In all modalities tumor volume was measured by two independent readers. Contrast-to-noise ratio (CNR) and Signal-to-noise ratio (SNR) were measured from reconstructed CT-scans (0.5 mm slice thickness; n = 18). RESULTS: Tumor volumes (mean±SD mm3) were similar between both CT-modalities (micro-CT: 19.8±19.0, clinical CT: 19.8±18.8; Wilcoxon signed-rank test p = 0.813). Moreover, between reader analyses for each modality showed excellent agreement as demonstrated by correlation analysis (Spearman-Rho >0.9; p<0.01 for all correlations). Histologically measured tumor volumes (11.0±11.2) were significantly smaller due to shrinkage artifacts (p<0.05). CNR and SNR were 2.1±1.0 and 1.1±0.04 for micro-CT and 23.1±24.0 and 1.9±0.7 for the clinical CTscanner, respectively. CONCLUSION: Clinical CT scanners may reliably be used for in vivo imaging and volumetric analysis of brain tumor growth in mice.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Glioblastoma/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Animais , Encéfalo/patologia , Linhagem Celular Tumoral , Meios de Contraste/administração & dosagem , Feminino , Humanos , Subunidade gama Comum de Receptores de Interleucina/deficiência , Subunidade gama Comum de Receptores de Interleucina/genética , Iopamidol/administração & dosagem , Iopamidol/análogos & derivados , Masculino , Camundongos Endogâmicos NOD , Camundongos Knockout , Camundongos SCID , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Transplante Heterólogo
13.
Oncotarget ; 7(29): 45500-45512, 2016 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-27275537

RESUMO

Patients with actively replicating human immunodeficiency virus (HIV) exhibit adverse reactions even to low irradiation doses. High levels of the virus-encoded viral protein R (Vpr) are believed to be one of the major underlying causes for increased radiosensitivity. As Vpr efficiently crosses the blood-brain barrier and accumulates in astrocytes, we examined its efficacy as a drug for treatment of glioblastoma multiforme (GBM).In vitro, four glioblastoma-derived cell lines with and without methylguanine-DNA methyltransferase (MGMT) overexpression (U251, U87, U251-MGMT, U87-MGMT) were exposed to Vpr, temozolomide (TMZ), conventional photon irradiation (2 to 6 Gy) or to combinations thereof. Vpr showed high rates of acute toxicities with median effective doses of 4.0±1.1 µM and 15.7±7.5 µM for U251 and U87 cells, respectively. Caspase assays revealed Vpr-induced apoptosis in U251, but not in U87 cells. Vpr also efficiently inhibited clonogenic survival in both U251 and U87 cells and acted additively with irradiation. In contrast to TMZ, Vpr acted independently of MGMT expression.Dose escalation in mice (n=12) was feasible and resulted in no evident renal or liver toxicity. Both, irradiation with 3x5 Gy (n=8) and treatment with Vpr (n=5) delayed intracerebral tumor growth and prolonged overall survival compared to untreated animals (n=5; p3x5 Gy<0.001 and pVpr=0.04; log-rank test).Our data show that the HIV-encoded peptide Vpr exhibits all properties of an effective chemotherapeutic drug and may be a useful agent in the treatment of GBM.


Assuntos
Antineoplásicos/farmacologia , Apoptose/efeitos dos fármacos , Neoplasias Encefálicas/patologia , Glioma/patologia , Produtos do Gene vpr do Vírus da Imunodeficiência Humana/farmacologia , Animais , Linhagem Celular Tumoral , Humanos , Camundongos , Ensaios Antitumorais Modelo de Xenoenxerto
14.
Pflege ; 29(4): 193-203, 2016 07.
Artigo em Alemão | MEDLINE | ID: mdl-27239739

RESUMO

Background: In response to demographic trends in Germany nursing competencies are currently reevaluated. Since these have to be taught and trained in nursing education programs, efficient verification of the success is necessary. OSCEs are internationally well-recognized as a comprehensive tool for that. Aim: In this analysis we identified competencies worldwide, which are tested by OSCEs in undergraduate nursing education programs. Method: An international literature research was conducted. The selection criterion for an article was the specification of at least one verifiable competency. Afterwards the competencies were categorized into knowledge, skills and attitudes according to the German "Fachqualifikationsrahmen Pflege für die hochschulische Bildung". Results: A total of 36 publications fulfilled all inclusion criteria. Relevant studies were predominantly initiated in the UK, Canada and Australia. Within all categories a total of n = 166 different competencies are mentioned. OSCEs are developed and performed in a broad range of methods. Most frequently skills were verified. The most common topic was sure handling of medication. Other important themes were communicative competencies in relation to patients and the ability of self-evaluation. Discussion/Conclusions: A variation in examination methods is appropriate as different competencies are acquired in preparation of the test. Evaluation took place on an individual or institutional level. Further research is needed.


Assuntos
Competência Clínica/estatística & dados numéricos , Comparação Transcultural , Educação em Enfermagem , Avaliação Educacional/estatística & dados numéricos , Alemanha , Humanos
15.
PLoS One ; 10(6): e0130661, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26098622

RESUMO

BACKGROUND: Repetitive administration of medication or contrast agents is frequently performed in mice. The introduction of vascular access mini-ports (VAMP) for mice allows long-term vascular catheterization, hereby eliminating the need for repeated vessel puncture. With catheter occlusion being the most commonly reported complication of chronic jugular vein catheterization, we tested whether digital subtraction angiography (DSA) can be utilized to evaluate VAMP patency in mice. METHODS: Twenty-three mice underwent catheterization of the jugular vein and subcutaneous implantation of a VAMP. The VAMP was flushed every second day with 50 µL of heparinized saline solution (25 IU/ml). DSA was performed during injection of 100 µL of an iodine based contrast agent using an industrial X-ray inspection system intraoperatively, as well as 7±2 and 14±2 days post implantation. RESULTS: DSA allowed localization of catheter tip position, to rule out dislocation, kinking or occlusion of a microcatheter, and to evaluate parent vessel patency. In addition, we observed different ante- and retrograde collateral flow patterns in case of jugular vein occlusion. More exactly, 30% of animals showed parent vessel occlusion after 7±2 days in our setting. At this time point, nevertheless, all VAMPs verified intravascular contrast administration. After 14±2 days, intravascular contrast injection was verified in 70% of the implanted VAMPs, whereas at this point of time 5 animals had died or were sacrificed and in 2 mice parent vessel occlusion hampered intravascular contrast injection. Notably, no occlusion of the catheter itself was observed. CONCLUSION: From our observations we conclude DSA to be a fast and valuable minimally invasive tool for investigation of catheter and parent vessel patency and for anatomical studies of collateral blood flow in animals as small as mice.


Assuntos
Angiografia Digital/métodos , Cateterismo Venoso Central/métodos , Cateteres Venosos Centrais/efeitos adversos , Angiografia Digital/instrumentação , Animais , Cateterismo Venoso Central/instrumentação , Meios de Contraste/administração & dosagem , Masculino , Camundongos , Camundongos Endogâmicos C57BL
16.
PLoS One ; 10(5): e0126246, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25993010

RESUMO

PURPOSE/OBJECTIVE: Although radiotherapy is a key component of cancer treatment, its implementation into pre-clinical in vivo models with relatively small target volumes is frequently omitted either due to technical complexity or expected side effects hampering long-term observational studies. We here demonstrate how an affordable industrial micro-CT can be converted into a small animal IGRT device at very low costs. We also demonstrate the proof of principle for the case of partial brain irradiation of mice carrying orthotopic glioblastoma implants. METHODS/MATERIALS: A commercially available micro-CT originally designed for non-destructive material analysis was used. It consists of a CNC manipulator, a transmission X-ray tube (10-160 kV) and a flat-panel detector, which was used together with custom-made steel collimators (1-5 mm aperture size). For radiation field characterization, an ionization chamber, water-equivalent slab phantoms and radiochromic films were used. A treatment planning tool was implemented using a C++ application. For proof of principle, NOD/SCID/γc(-/-) mice were orthotopically implanted with U87MG high-grade glioma cells and irradiated using the novel setup. RESULTS: The overall symmetry of the radiation field at 150 kV was 1.04 ± 0.02%. The flatness was 4.99 ± 0.63% and the penumbra widths were between 0.14 mm and 0.51 mm. The full width at half maximum (FWHM) ranged from 1.97 to 9.99 mm depending on the collimator aperture size. The dose depth curve along the central axis followed a typical shape of keV photons. Dose rates measured were 10.7 mGy/s in 1 mm and 7.6 mGy/s in 5 mm depth (5 mm collimator aperture size). Treatment of mice with a single dose of 10 Gy was tolerated well and resulted in central tumor necrosis consistent with therapeutic efficacy. CONCLUSION: A conventional industrial micro-CT can be easily modified to allow effective small animal IGRT even of critical target volumes such as the brain.


Assuntos
Radioterapia Guiada por Imagem/métodos , Microtomografia por Raio-X/métodos , Animais , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Camundongos , Reprodutibilidade dos Testes
17.
Neurosurgery ; 77(1): 126-35; discussion 135-6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25714517

RESUMO

BACKGROUND: Treatment of wide-necked internal carotid artery aneurysms is frequently associated with incomplete occlusion and high recurrence rates. Furthermore, platinum coils cause strong beam-hardening artifacts, hampering subsequent image analyses. OBJECTIVE: To assess the feasibility, safety, and efficacy of flow-diverting, stent-assisted microsphere embolization of fusiform and sidewall aneurysms in vitro and in vivo. METHODS: Using a recirculating pulsatile in vitro flow model, 5 different aneurysm geometries (inner/outer curve, narrow/wide neck, and fusiform) were treated (each n = 1) by flow-diverting stent (FDS) implantation and subsequent embolization through a jailed microcatheter using calibrated microspheres (500-900 µm) larger than the pores of the FDS mesh. Treatment effects were analyzed angiographically and by micro computed tomography. The fluid of the in vitro model was filtered to ensure that no microspheres evaded the aneurysm. The experiment was repeated once in vivo. RESULTS: In vitro, all 5 aneurysms were safely and completely occluded by FDS-assisted microsphere embolization. Virtually complete aneurysm occlusion was confirmed by angiography and micro computed tomography. No microspheres escaped into the circulation. The experiment was successfully repeated in 1 pig with a sidewall aneurysm generated by vessel occlusion. An embolic protection system placed distally of the FDS in vitro and in vivo (each n = 1) contained no microspheres after the embolization. Thus, no microspheres were lost in the circulation, and the use of an embolic protection system seems feasible to provide additional safety. CONCLUSION: FDS-assisted microsphere embolization of fusiform and sidewall aneurysms is feasible and yields virtually complete aneurysm occlusion while avoiding coil-associated beam-hardening artifacts.


Assuntos
Doenças das Artérias Carótidas/cirurgia , Embolização Terapêutica/métodos , Aneurisma Intracraniano/cirurgia , Microesferas , Stents , Animais , Humanos , Modelos Biológicos , Suínos
18.
J Neurooncol ; 122(2): 245-54, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25605299

RESUMO

Small animal imaging is of increasing relevance in biomedical research. Studies systematically assessing the diagnostic accuracy of contrast-enhanced in vivo micro-CT of orthotopic glioma xenografts in mice do not exist. NOD/SCID/γc(-/-) mice (n = 27) underwent intracerebral implantation of 2.5 × 10(6) GFP-Luciferase-transduced U87MG cells. Mice underwent bioluminescence imaging (BLI) to detect tumor growth and afterwards repeated contrast-enhanced (300 µl Iomeprol i.v.) micro-CT imaging (80 kV, 75 µAs, 360° rotation, 1,000 projections, 33 s scan time, resolution 40 × 40 × 53 µm, 0.5 Gy/scan). Presence of tumors, tumor diameter and tumor volume in micro-CT were rated by two independent readers. Results were compared with histological analyses. Six mice with tumors confirmed by micro-CT received fractionated irradiation (3 × 5 Gy every other day) using the micro-CT (5 mm pencil beam geometry). Repeated micro-CT scans were tolerated well. Tumor engraftment rate was 74 % (n = 20). In micro-CT, mean tumor volume was 30 ± 33 mm(3), and the smallest detectable tumor measured 360 × 620 µm. The inter-rater agreement (n = 51 micro-CT scans) for the item tumor yes/no was excellent (Spearman-Rho = 0.862, p < 0.001). Sensitivity and specificity of micro-CT were 0.95 and 0.71, respectively (PPV = 0.91, NPV = 0.83). BLI on day 21 after tumor implantation had a sensitivity and specificity of 0.90 and 1.0, respectively (PPV = 1.0, NPV = 0.5). Maximum tumor diameter and volume in micro-CT and histology correlated excellently (tumor diameter: 0.929, p < 0.001; tumor volume: 0.969, p < 0.001, n = 17). Irradiated animals showed a large central tumor necrosis. Longitudinal contrast enhanced micro-CT imaging of brain tumor growth in live mice is feasible at high sensitivity levels and with excellent inter-rater agreement and allows visualization of radiation effects.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Glioblastoma/diagnóstico por imagem , Glioblastoma/radioterapia , Microtomografia por Raio-X/métodos , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/efeitos da radiação , Linhagem Celular Tumoral , Meios de Contraste , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Camundongos Endogâmicos NOD , Camundongos Knockout , Camundongos SCID , Transplante de Neoplasias , Sensibilidade e Especificidade , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...