Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Res Int ; 2016: 8594087, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27747242

RESUMO

Measurements of the root canal during endodontic treatment have a significant influence on the course of the therapeutic process as well as on its final result in both human and veterinary medicine. The apical constriction should be the termination point for the preparation and filling of the root canal. This research was conducted with the use of a Septodont kit consisting of a small chamber filled with the examined solution in which a healthy second incisor was placed. The step back method was applied for the root canal preparation and master apical file of 30 was used. The working length was 22 mm. The examination was conducted with the use of steel as well as nickel titanium hand instruments. Different irrigation solutions and two types of apex locators were used. Measurements of the working length of the root canal showed dependence on the size of the instrument. Examinations carried out in various environments showed that analogical measurements were obtained only for sodium hypochlorite solutions. In other environments the measured sections were shortened. Comparative examinations with the use of steel instruments demonstrated insignificant measurement differences. Compared to these results, the measurements in nickel titanium group were characterized by more considerable deviations.


Assuntos
Dente Canino/anatomia & histologia , Cavidade Pulpar/anatomia & histologia , Incisivo/anatomia & histologia , Soluções/administração & dosagem , Ápice Dentário/anatomia & histologia , Ligas/administração & dosagem , Animais , Instrumentos Odontológicos , Cães , Eletrônica Médica/métodos , Reprodutibilidade dos Testes , Materiais Restauradores do Canal Radicular/uso terapêutico , Preparo de Canal Radicular/métodos , Hipoclorito de Sódio/administração & dosagem , Aço
2.
Biomed Res Int ; 2016: 1879468, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27110558

RESUMO

The excessive temperature fluctuations during dental implant site preparation may affect the process of bone-implant osseointegration. In the presented studies, we aimed to assess the quality of cooling during the use of 3 different dental implant systems (BEGO®, NEO BIOTECH®, and BIOMET 3i®). The swine rib was chosen as a study model. The preparation of dental implant site was performed with the use of 3 different speeds of rotation (800, 1,200, and 1,500 rpm) and three types of cooling: with saline solution at room temperature, with saline solution cooled down to 3°C, and without cooling. A statistically significant difference in temperature fluctuations was observed between BEGO and NEO BIOTECH dental systems when cooling with saline solution at 3°C was used (22.3°C versus 21.8°C). In case of all three evaluated dental implant systems, the highest temperature fluctuations occurred when pilot drills were used for implant site preparation. The critical temperature, defined in the available literature, was exceeded only in case of pilot drills (of all 3 systems) used at rotation speed of 1,500 rpm without cooling.


Assuntos
Implantes Dentários , Raios Infravermelhos , Osseointegração/fisiologia , Termografia , Animais , Humanos , Suínos , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...