Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Plast Surg ; 93(1): 94-99, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38864419

RESUMO

BACKGROUND: In distal forefoot defect, finding wound closure is challenging because of the distal site and small blood vessels involved. One possible resolution is the utilization of a metatarsal artery flap in a 'U-turn' design. This method offers several advantages, including its long length and a viable option for distal forefoot defect. METHODS: Thirty-six patients with forefoot injuries from metatarsophalangeal (MTP) joint to distal interphalangeal (DIP) joint due to trauma were consecutively recruited and completed the study. Outcomes were analyzed descriptively, and risk prediction modeling for edge necrosis was performed. RESULTS: The mean ± SD follow-up time was 27.3 months ±1.9. The median (IQR) MTP-to-DIP joint wound width and length were 1.8 (1.4, 3.0) and 3.2 cm (2.9, 6.2), respectively. The median (IQR) width, length, and width-to-length ratio flap dimensions were 3.6 (2.8, 6.0), 4.7 cm (4.3, 9.3), and 1.5 (1.2, 1.7), respectively. The mean ± SD operative time was 32.9 min ± 5.7. The median (IQR) intraoperative blood loss was 5.0 mL (4.0, 5.0). The mean ± SD hospital length of stay postoperatively was 4.0 days ±1.0. The mean ± SD Foot and Ankle Outcome Score and Foot Function Index were 64.1 ± 2.5 and 7.8% ± 3.3, respectively. All patients had good or excellent aesthetic satisfaction. Spontaneously resolving edge necrosis occurred in 13.9%. The mean ± SD time-to-start-ambulation was 1.7 weeks ±0.5. At the 2-year follow-up visit, all patients had reduced U-turn flap pivot point redundancy without shoe size impact, needing reoperation, or donor site morbidity. Edge necrosis was significantly associated with length-to-width ratio ( P = 0.014) but not with Foot and Ankle Outcome Score or Foot Function Index. CONCLUSIONS: Metatarsal artery flap of U-turn design was reliable and was associated with a short recovery time, alternative resolution for forefoot area due to short operation time, minimal blood loss, short hospital length of stay, and excellent availability.


Assuntos
Traumatismos do Pé , Procedimentos de Cirurgia Plástica , Humanos , Masculino , Feminino , Adulto , Traumatismos do Pé/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Pessoa de Meia-Idade , Antepé Humano/cirurgia , Retalhos Cirúrgicos/irrigação sanguínea , Resultado do Tratamento , Seguimentos , Lesões dos Tecidos Moles/cirurgia , Cicatrização/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...