Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Microbiol Spectr ; 9(1): e0034221, 2021 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-34346748

RESUMO

As the COVID-19 pandemic progresses, there is an increasing need for rapid, accessible assays for SARS-CoV-2 detection. We present a clinical evaluation and real-world implementation of the INDICAID COVID-19 rapid antigen test (INDICAID rapid test). A multisite clinical evaluation of the INDICAID rapid test using prospectively collected nasal (bilateral anterior) swab samples from symptomatic subjects was performed. The INDICAID rapid test demonstrated a positive percent agreement (PPA) and negative percent agreement (NPA) of 85.3% (95% confidence interval [95% CI], 75.6% to 91.6%) and 94.9% (95% CI, 91.6% to 96.9%), respectively, compared to laboratory-based reverse transcriptase PCR (RT-PCR) using nasal specimens. The INDICAID rapid test was then implemented at COVID-19 outbreak screening centers in Hong Kong as part of a testing algorithm (termed "dual-track") to screen asymptomatic individuals for prioritization for confirmatory RT-PCR testing. In one approach, preliminary positive INDICAID rapid test results triggered expedited processing for laboratory-based RT-PCR, reducing the average time to confirmatory result from 10.85 h to 7.0 h. In a second approach, preliminary positive results triggered subsequent testing with an onsite rapid RT-PCR, reducing the average time to confirmatory result to 0.84 h. In 22,994 asymptomatic patients, the INDICAID rapid test demonstrated a PPA of 84.2% (95% CI, 69.6% to 92.6%) and an NPA of 99.9% (95% CI, 99.9% to 100%) compared to laboratory-based RT-PCR using combined nasal/oropharyngeal specimens. The INDICAID rapid test has excellent performance compared to laboratory-based RT-PCR testing and, when used in tandem with RT-PCR, reduces the time to confirmatory positive result. IMPORTANCE Laboratory-based RT-PCR, the current gold standard for COVID-19 testing, can require a turnaround time of 24 to 48 h from sample collection to result. The delayed time to result limits the effectiveness of centralized RT-PCR testing to reduce transmission and stem potential outbreaks. To address this, we conducted a thorough evaluation of the INDICAID COVID-19 rapid antigen test, a 20-minute rapid antigen test, in both symptomatic and asymptomatic populations. The INDICAID rapid test demonstrated high sensitivity and specificity with RT-PCR as the comparator method. A dual-track testing algorithm was also evaluated utilizing the INDICAID rapid test to screen for preliminary positive patients, whose samples were then prioritized for RT-PCR testing. The dual-track method demonstrated significant improvements in expediting the reporting of positive RT-PCR test results compared to standard RT-PCR testing without prioritization, offering an improved strategy for community testing and controlling SARS-CoV-2 outbreaks.


Assuntos
Antígenos Virais/análise , Doenças Assintomáticas , Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , SARS-CoV-2/isolamento & purificação , Adulto , Técnicas de Laboratório Clínico/métodos , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Hong Kong , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Pandemias , Reação em Cadeia da Polimerase , SARS-CoV-2/genética , Sensibilidade e Especificidade , Manejo de Espécimes , Fatores de Tempo , Adulto Jovem
2.
Viruses ; 13(4)2021 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-33918447

RESUMO

SARS-CoV-2 RT-PCR with pooled specimens has been implemented during the COVID-19 pandemic as a cost- and manpower-saving strategy for large-scale testing. However, there is a paucity of data on the efficiency of different nucleic acid extraction platforms on pooled specimens. This study compared a novel automated high-throughput liquid-based RNA extraction (LRE) platform (PHASIFY™) with a widely used magnetic bead-based total nucleic acid extraction (MBTE) platform (NucliSENS® easyMAG®). A total of 60 pools of nasopharyngeal swab and 60 pools of posterior oropharyngeal saliva specimens, each consisting of 1 SARS-CoV-2 positive and 9 SARS-CoV-2 negative specimens, were included for the comparison. Real-time RT-PCR targeting the SARS-CoV-2 RdRp/Hel gene was performed, and GAPDH RT-PCR was used to detect RT-PCR inhibitors. No significant differences were observed in the Ct values and overall RT-PCR positive rates between LRE and MBTE platforms (92.5% (111/120] vs. 90% (108/120]), but there was a slightly higher positive rate for LRE (88.3% (53/60]) than MBTE (81.7% (49/60]) among pooled saliva. The automated LRE method is comparable to a standard MBTE method for the detection of SAR-CoV-2 in pooled specimens, providing a suitable alternative automated extraction platform. Furthermore, LRE may be better suited for pooled saliva specimens due to more efficient removal of RT-PCR inhibitors.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/métodos , COVID-19/epidemiologia , Humanos , Programas de Rastreamento , Nasofaringe/virologia , RNA Viral/genética , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , Saliva/virologia , Manejo de Espécimes/instrumentação
3.
Biophys J ; 113(8): 1858-1867, 2017 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-29045879

RESUMO

In this work, we introduce, to our knowledge, a new set of adhesion-based biomarkers for characterizing mammalian cells. Mammalian cell adhesion to the extracellular matrix influences numerous physiological processes. Current in vitro methods to probe adhesion focus on adhesive force to a single surface, which can investigate only a subcomponent of the adhesive, motility, and polarization cues responsible for adhesion in the 3D tissue environment. Here, we demonstrate a method to quantify the transhesive properties of cells that relies on the microscale juxtaposition of two extracellular matrix-coated surfaces. By multiplexing this approach, we investigate the unique transhesive profiles for breast cancer cells that are adapted to colonize different metastatic sites. We find that malignant breast cancer cells readily transfer to new collagen I surfaces, and away from basement membrane proteins. Integrins and actin polymerization largely regulate this transfer. This tool can be readily adopted in cell biology and cancer research to uncover, to our knowledge, novel drivers of adhesion (or de-adhesion) and sort cell populations based on complex phenotypes with physiological relevance.


Assuntos
Adesão Celular/fisiologia , Técnicas Citológicas , Actinas/metabolismo , Neoplasias da Mama/patologia , Neoplasias da Mama/fisiopatologia , Linhagem Celular Tumoral , Colágeno , Meios de Cultura , Dimetilpolisiloxanos , Células Epiteliais/citologia , Células Epiteliais/fisiologia , Vidro , Humanos , Processamento de Imagem Assistida por Computador , Imuno-Histoquímica , Integrinas/metabolismo , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/fisiopatologia , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/fisiologia , Microscopia de Fluorescência , Nylons , Propriedades de Superfície
4.
Lab Chip ; 15(19): 3818-21, 2015 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-26309035

RESUMO

Polymer particles with precise shapes or chemistries are finding unique uses in a variety of applications, including tissue engineering, drug delivery, barcoding, and diagnostic imaging. Microfluidic systems have been and are continuing to play a large role in enabling the precision synthesis of designer particles in a uniform manner. To expand the impact of these microfluidic-fabricated materials additional fundamental capabilities should still be developed. The capability to fabricate microparticles with complex three-dimensional shapes and increase the production rate of particles to an industrial scale will allow evaluation of shaped particles in a range of new applications to enhance biological, magnetic, optical, surface wetting, as well as other interfacial or mechanical properties of materials. Here we highlight work applying large collections of simple spherical microgels, with unique surface chemistry that allows in situ particle-particle annealing, to form microporous injectable scaffolds for accelerated tissue regeneration. We also report on two other techniques that are addressing the ability to create 3D-shaped microparticles by first sculpting a fluid precursor stream, and increasing the rate of production of particles using contact lithography to millions of particles per hour. The combination of these capabilities and the applications they will enable suggest a bright future for microfluidics in making the next materials.

5.
Curr Opin Biotechnol ; 25: 114-23, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24484889

RESUMO

Micro-scale biological tools that have allowed probing of individual cells--from the genetic, to proteomic, to phenotypic level--have revealed important contributions of single cells to direct normal and diseased body processes. In analyzing single cells, sample heterogeneity between and within specific cell types drives the need for high-throughput and quantitative measurement of cellular parameters. In recent years, high-throughput single-cell analysis platforms have revealed rare genetic subpopulations in growing tumors, begun to uncover the mechanisms of antibiotic resistance in bacteria, and described the cell-to-cell variations in stem cell differentiation and immune cell response to activation by pathogens. This review surveys these recent technologies, presenting their strengths and contributions to the field, and identifies needs still unmet toward the development of high-throughput single-cell analysis tools to benefit life science research and clinical diagnostics.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Microtecnologia/métodos , Análise de Célula Única/métodos , Animais , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Microtecnologia/instrumentação , Neoplasias/química , Proteômica , Análise de Célula Única/instrumentação , Células-Tronco/química
6.
Lab Chip ; 14(7): 1226-9, 2014 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-24557413

RESUMO

In this issue we highlight recent microtechnology-enabled approaches to control the physical and biomolecular environment around cells: (1) developing micropatterned surfaces to quantify cell affinity choices between two adhesive patterns, (2) controlling topographical cues to align cells and improve reprogramming to a pluripotent state, and (3) controlling gradients of biomolecules to maintain pluripotency in embryonic stem cells. Quantitative readouts of cell-surface affinity in environments with several cues should open up avenues in tissue engineering where self-assembly of complex multi-cellular structures is possible by precisely engineering relative adhesive cues in three dimensional constructs. Methods of simple and local epigenetic modification of chromatin structure with microtopography and biomolecular gradients should also be of use in regenerative medicine, as well as in high-throughput quantitative analysis of external signals that impact and can be used to control cells. Overall, approaches to engineer the cellular environment will continue to be an area of further growth in the microfluidic and lab on a chip community, as the scale of the technologies seamlessly matches that of biological systems. However, because of regulations and other complexities with tissue engineered therapies, these micro-engineering approaches will likely first impact organ-on-a-chip technologies that are poised to improve drug discovery pipelines.


Assuntos
Engenharia Celular/métodos , Cromatina , Epigênese Genética , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/métodos , Adesão Celular
7.
Biomicrofluidics ; 6(2): 24104-2410413, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22536308

RESUMO

Ovarian cancer is the leading cause of death from gynecological malignancies in women. The primary challenge is the detection of the cancer at an early stage, since this drastically increases the survival rate. In this study we investigated the dielectrophoretic responses of progressive stages of mouse ovarian surface epithelial (MOSE) cells, as well as mouse fibroblast and macrophage cell lines, utilizing contactless dielectrophoresis (cDEP). cDEP is a relatively new cell manipulation technique that has addressed some of the challenges of conventional dielectrophoretic methods. To evaluate our microfluidic device performance, we computationally studied the effects of altering various geometrical parameters, such as the size and arrangement of insulating structures, on dielectrophoretic and drag forces. We found that the trapping voltage of MOSE cells increases as the cells progress from a non-tumorigenic, benign cell to a tumorigenic, malignant phenotype. Additionally, all MOSE cells display unique behavior compared to fibroblasts and macrophages, representing normal and inflammatory cells found in the peritoneal fluid. Based on these findings, we predict that cDEP can be utilized for isolation of ovarian cancer cells from peritoneal fluid as an early cancer detection tool.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA