Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Nutr ESPEN ; 61: 119-130, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38777423

RESUMO

BACKGROUND & AIMS: Serum retinol (ROH) is commonly used for population level assessment of vitamin A status. High-performance liquid chromatography (HPLC) is considered most accurate method for measuring ROH. However, with the technical difficulty of using HPLC for routine assays, serum retinol-binding protein (RBP) measured by immunological assays is expected to be a surrogate marker for ROH, with reports of a close correlation between serum RBP and ROH. Nevertheless, RBP is not commonly tested to assess vitamin A status with concerns over RBP alterations under various physiopathological conditions. Thus, we reappraised the extent to which RBP could be used as a surrogate marker in representative disorders that alter serum RBP levels. As a related marker, diagnostic utility of transthyretin (TTR) was also evaluated. METHODS: To evaluate the reliability of ROH and RBP assays, specimen stability was assessed in terms of (1) storage at 25, 4, -20, and -80 °C for 1-28 days, (2) five-cycle freeze-thawing, and (3) fluorescent light exposure for 1-14 days. Sources of variation (sex, age, body mass index [BMI], and drinking habits) and reference intervals for ROH, RBP, and TTR were determined in 617 well-defined healthy individuals. To investigate the influence of disorders that affect serum RBP, patients with five diagnostic groups were enrolled: 26 with chronic kidney disease (CKD); 13 with various malignancies in advanced stages (AdM), 12 with acute bacterial infections (ABI), 6 with liver cirrhosis (LC), and 26 with simple obesity (BMI ≥ 27 kg/m2). RESULTS: The stability of RBP and ROH in serum was confirmed under all conditions. In healthy individuals, serum ROH, RBP, and TTR were appreciably high in males with a slight increase in proportion to age and BMI. The major-axis regression line between RBP (x) and ROH (y) in healthy individuals was y = x, with a correlation coefficient of 0.986. In the LC, AdM, and ABI groups, similar strong correlations were observed; however, the regression lines were shifted slightly rightward from the healthy group line, indicating a positive bias in estimating ROH. Interestingly, the same analyses between TTR and ROH revealed similar strong linear relationships in all groups; however, the regression line of each group showed a leftward (opposite) shift from the healthy group line. Based on these observations, we developed a novel regression model composed of RBP and TTR, which gave much improved accuracy in estimating ROH, even under these pathological conditions. CONCLUSIONS: The perfect RBP-ROH correlation in healthy individuals indicates the utility of RPB as a surrogate marker for ROH. Nevertheless, under RBP-altered conditions, a slight overestimation of ROH is inevitable. However, when the TTR was tested together, the bias can be corrected almost perfectly using the novel ROH estimation formula comprising RBP and TTR.


Assuntos
Biomarcadores , Pré-Albumina , Proteínas de Ligação ao Retinol , Vitamina A , Humanos , Biomarcadores/sangue , Masculino , Vitamina A/sangue , Feminino , Pessoa de Meia-Idade , Adulto , Proteínas de Ligação ao Retinol/análise , Proteínas de Ligação ao Retinol/metabolismo , Pré-Albumina/análise , Pré-Albumina/metabolismo , Idoso , Reprodutibilidade dos Testes , Cromatografia Líquida de Alta Pressão , Índice de Massa Corporal , Adulto Jovem , Estado Nutricional
2.
J Nutr Sci Vitaminol (Tokyo) ; 69(6): 412-419, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38171813

RESUMO

Retinol-binding protein 4 (RBP4) is a retinol transporter in the blood plasma. Many diseases alter the plasma or serum levels of RBP4. Since serum RBP4 concentrations have been reported to decrease in hyperthyroidism, this study investigated whether serum RBP4 concentrations increased or remained constant in hypothyroidism. In sera from patients with hypothyroidism (n=71), hyperthyroidism (n=30), and healthy subjects (n=20), serum concentrations of RBP4 (sum of holo- and apo-RBP4), retinol, albumin, creatinine, and related constituents were measured, and RBP4/retinol molar ratio (as an index of apo-RBP4) and estimated glomerular filtration rate (eGFR) were calculated. The results showed that serum RBP4 concentrations tended to increase with decreasing free thyroxine concentrations, but there were no significant differences among patients with hypothyroidism, hyperthyroidism, and healthy subjects. When patients with hypothyroidism were subdivided by serum RBP4 level using 2.1 µmol/L cut-off value, patients with >2.1 µmol/L were revealed to be patients with older age having lower tri-iodothyronine, higher holo-RBP4, higher apo-RBP4, higher retinol, higher RBP4/retinol molar ratio, and lower eGFR than those in patients with <2.1 µmol/L. Multiple regression analysis showed significant associations between serum RBP4 levels and explanatory variables (retinol and eGFR). Although serum levels of RBP4 prior to the onset of renal dysfunction may affect the present concentrations, we conclude that the increase of serum RBP4 (both holo- and apo-RBP4) in patients with hypothyroidism was attributed to the decline in eGFR. In contrast, serum RBP4 concentration remained constant without renal dysfunction.


Assuntos
Hipertireoidismo , Hipotireoidismo , Nefropatias , Humanos , Vitamina A , Proteínas de Ligação ao Retinol , Proteínas Plasmáticas de Ligação ao Retinol/análise , Proteínas Plasmáticas de Ligação ao Retinol/metabolismo
3.
Ann Clin Biochem ; 58(6): 563-571, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34120480

RESUMO

BACKGROUND: In vitro diagnostic bilirubin reagents based on oxidation with bilirubin oxidase or vanadic acid for total and direct-reacting bilirubin are widely used in Japan; however, their reactivity to unconjugated and conjugated bilirubin and delta bilirubin has not been completely disclosed by manufacturers. We used artificially prepared bilirubin materials to investigate the reactivity with four in vitro diagnostic bilirubin reagents. METHODS: Porcine unconjugated bilirubin solution, chemically synthesized ditaurobilirubin solution, and chemically synthesized delta bilirubin solution were used as surrogates of naturally occurring unconjugated bilirubin, conjugated bilirubin, and delta bilirubin, respectively. The total bilirubin and direct-reacting bilirubin concentrations were measured by three bilirubin oxidase methods and one vanadic acid method, and the observed concentrations were compared with those obtained by the diazo-based reference measurement procedure. RESULTS: The unconjugated bilirubin and delta bilirubin concentrations were similar when any of the four in vitro diagnostic bilirubin reagents were used during total bilirubin measurement. This was consistent with reference measurement procedure and exhibited a converged inter-method variation. Compared with reference measurement procedure, significantly low ditaurobilirubin concentrations were observed by the in vitro diagnostic bilirubin reagents despite the converged inter-method variation. In delta bilirubin measurement, some reagents reacted doubtfully with unconjugated bilirubin, while showed lower ditaurobilirubin concentrations than its corresponding total bilirubin concentration. Reactivity with delta bilirubin was different for each method including reference measurement procedure. Some reagents were developed to react less with delta bilirubin and others to strongly react with delta bilirubin. CONCLUSIONS: We revealed the reactivity of IVD-TB and IVD-DB reagents to artificially prepared bilirubin materials, and their consistency with reference measurement procedure. The delta bilirubin data results vary depending on the reagents used.


Assuntos
Bilirrubina , Taurina , Animais , Indicadores e Reagentes , Japão , Oxirredução , Suínos , Taurina/análise
4.
J Nutr Sci Vitaminol (Tokyo) ; 65(5): 451-454, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31666483

RESUMO

Serum bilirubin measurement is necessary to accurately distinguish jaundice from carotenemia. A 59.8-y old Japanese male showed symptoms of yellow skin pigmentation as a result of ß-carotenemia. Diagnostic laboratory results indicated elevated levels of serum muscle enzymes (aspartate aminotransferase, lactate dehydrogenase, and creatine kinase), but normal levels in liver function tests (alanine aminotransferase and direct bilirubin). The laboratory results indicated hypothyroid myopathy. Moreover, although the patient did not show significant abnormalities in liver function tests, the serum level of total bilirubin (TBIL) measured by bilirubin oxidase method was markedly increased beyond the upper limit of normal. Fundamental experiments revealed that the bilirubin oxidase method had a positive interference by ß-carotene. These findings suggested that hyper ß-carotenemia could have caused the falsely elevated serum TBIL levels in the patient.


Assuntos
Bilirrubina/sangue , Icterícia/diagnóstico , Oxirredutases atuantes sobre Doadores de Grupo CH-CH/análise , Transtornos da Pigmentação/diagnóstico , beta Caroteno/deficiência , Erros de Diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos da Pigmentação/etiologia
5.
Ann Clin Biochem ; 55(6): 647-656, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29534611

RESUMO

Background To assess the vitamin D nutritional status, serum total 25-hydroxyvitamin D (25(OH)D) concentration is measured. We used six automated 25(OH)D immunoassays (AIAs) available in Japan and certified by the Vitamin D Standardization Program (VDSP) at the U.S. Center for Disease Control and Prevention to assess the concordance of the assay results. Methods Serum total 25(OH)D concentrations in SRM 972a and 20 serum samples from patients were determined using three liquid chromatography-tandem mass spectrometry (LC-MS/MS) and six AIAs (pilot study), and an additional 110 serum samples were assessed by the six AIAs (surveillance study). The assay bias from the results of LC-MS/MS by Chiba University or consensus values (i.e. average of six AIAs) was estimated using the procedure described in CLSI document EP09-A3. Results LC-MS/MS at Chiba University could completely separate 25(OH)D2, 25(OH)D3 and 3-epi-25(OH)D3, and the observed values including total 25(OH)D in SRM 972a were all within ±1·SD of the assigned values. All AIAs produced results greater than ±3·SD. In the pilot study, four of the six AIAs had an average percentage bias, as estimated by confidence interval (CI), larger than ±5% (acceptance criterion in CLSI); the bias converged from -6.5% to 3.2% after adjustment by LC-MS/MS. In the surveillance study, 25(OH)D concentrations in AIAs all adjusted to LC-MS/MS converged within ±5% from consensus values. However, some AIAs showed negative or positive bias from the consensus values. Conclusions Current AIAs in Japan continue to lack standardization. Manufacturers should implement quality assurance strategies so that their values more closely align to those of standard reference material 972a.


Assuntos
Cromatografia Líquida , Imunoensaio/normas , Espectrometria de Massas , Vitamina D/análogos & derivados , Adulto , Automação , Cromatografia Líquida/normas , Humanos , Japão , Espectrometria de Massas/normas , Projetos Piloto , Vitamina D/sangue
6.
Mamm Genome ; 13(2): 80-8, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11889555

RESUMO

A precise genetic map containing anonymous markers and genes is indispensable for the efficient selection of candidate gene(s) responsible for quantitative trait loci (QTL) traits. For this purpose, a first version of a radiation hybrid cell (RH) map has been constructed by using the INRA-University of Minnesota RH panel for 757 markers (IMpRH) (Hawken et al. 1999, Mamm. Genome 10: 824--830). In this study, 280 swine genomic fragments in BAC clones were assigned to the IMpRH map; 255 BAC clones were successfully linked to first-generation linkage groups (LOD > 4.8). The remaining 25 clones could not be mapped, because their lod-scores to the closest markers in the first generation map were less than 4.8. In addition, 16 BAC clones, mapped to swine Chromosome (Chr) 1 by IMpRH mapping, were subjected to isolation of microsatellites (MSs). Thirty-one MSs were isolated from 15 BAC clones, and 24 of 31 (77%) MSs derived from 14 clones were found to be polymorphic. We also mapped both termini of 12 BAC clones to the IMpRH map, in order to measure resolution of the IMpRH map; the resolution was found to range from 8 kb/centiRay to more than 126 kb/centiRay depending on the region.


Assuntos
Genoma , Repetições de Microssatélites/genética , Mapeamento Físico do Cromossomo , Suínos/genética , Animais , Sequência de Bases , Cromossomos Artificiais Bacterianos/fisiologia , Clonagem Molecular , Primers do DNA/genética , Marcadores Genéticos , Dados de Sequência Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...