Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
World J Pediatr Congenit Heart Surg ; 15(3): 371-379, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38327093

RESUMO

BACKGROUND: Restoring adequate coaptation height is a key principle of mitral valve (MV) repair. This study aimed to evaluate the utility of fiberscope (FS) technology to assess MV coaptation height for intraoperative use. METHODS: Ex-vivo testing was performed on five adult porcine hearts. The left atrium (LA) was resected, and the left ventricle (LV) was pressurized retrograde to 27 ± 1mm Hg. An endoscope was inserted into the LV apex, centered under the MV orifice. An FS system (Milliscope II camera, LED light source, and 0.7 mm diameter × 15 cm long) 90° semirigid scope with 1.2 mm focal length) was mounted above the MV annulus in a custom alignment and measuring fixture. Three blinded measurements were taken at two locations on each MV, A2 and P2 segment, from the top of coaptation to the leaflet edge identified by the FS. Accurate positioning was verified using the LV endoscope. A control (metal rod of similar thickness) was used for comparison, with coaptation height recorded when the control was seen via the endoscope. RESULTS: Coaptation heights were similar for the control and FS methods across all hearts at A2 (11.6 ± 2.6 mm control vs 11.8 ± 2.2 mm FS) and P2 (13.3 ± 2.6 mm control vs 13.4 ± 2.9 mm FS) segments, with similar measurement variability (control SD 0.1-1.0 mm; FS SD 0.1-0.9 mm). One outlier was excluded from analysis (n = 19/20). The maximum absolute difference and percent error between measurement methods were less than 1.1 mm (median [IQR], 0.6 [0.3-0.9] mm) and less than 14% (4.1 [2.2-7.6]%). CONCLUSIONS: Utilization of a miniaturized FS enabled precise and accurate quantification of MV coaptation. This technique is promising for evaluating post-repair valve competence and coaptation height.


Assuntos
Valva Mitral , Animais , Suínos , Valva Mitral/cirurgia , Desenho de Equipamento , Modelos Animais de Doenças , Endoscopia/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Insuficiência da Valva Mitral/cirurgia , Tecnologia de Fibra Óptica
2.
Artigo em Inglês | MEDLINE | ID: mdl-38134426

RESUMO

OBJECTIVES: Optimal aortic sizing during aortic arch reconstruction remains unknown. Negative effects of arch under- or oversizing are well-published. We aimed to characterize longitudinal aortic growth after patch-augmented arch reconstruction to identify the initial reconstructed arch size that results in normal mid-term arch dimensions. METHODS: Single-centre, retrospective review of infants undergoing Damus-Kaye-Stansel (DKS) or non-DKS patch-augmented aortic arch reconstruction between 2000 and 2021. Ascending aorta, proximal and distal transverse arch, aortic isthmus (AIsth) and descending aorta dimensions were measured in postoperative echocardiograms (<3 months from index operation) and cross-sectional imaging (>12 months). Longitudinal changes to aortic dimensions and z-scores were analysed. Secondary outcomes included reintervention, valve and ventricular function, mortality and transplantation. RESULTS: Fifty-four patients (16 DKS, 38 non-DKS) were included. At 6.3 [2.2, 12.0]-year follow-up, all aortic segments grew significantly in both groups, while z-scores remained unchanged except for non-DKS proximal and distal transverse arch z-scores, which significantly increased (P < 0.05 each). When stratified by initial postoperative z-score (z < -1, -1 ≤ z ≤ 1, z > 1), non-DKS patients with initial AIsth z-score <-1 had a final z-score significantly smaller than both the targeted z-score zero (P = 0.014) and final z-score in a group with initial postoperative z-score ±1 (P = 0.009). Valve and ventricular function remained stable. Eighteen patients required reintervention, 1 died and 1 underwent transplant. CONCLUSIONS: Over mid-term follow-up, aortic growth after arch reconstruction with patch augmentation was proportional when repaired to normal z-score dimensions, aside from proximal transverse arch, which disproportionately dilated. AIsth undersizing prevailed mid-term and trended towards a higher reintervention rate. Initial reconstruction between z-score 0 and +1 resulted in maintenance of that z-score size at mid-term follow-up. Overall, it is crucial to achieve targeted aortic sizing at index operation to maintain appropriate aortic dimensions over time and reduce reintervention risk with specific focus on the AIsth.

3.
Cardiovasc Eng Technol ; 14(6): 827-839, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37973699

RESUMO

PURPOSE: Pulmonary valve (PV) monocusp reconstruction in transannular patch (TAP) right ventricular outflow tract (RVOT) repair for Tetralogy of Fallot has variable clinical outcomes across different surgical approaches. The study purpose was to systematically evaluate how monocusp leaflet design parameters affect valve function in-vitro. METHODS: A 3D-printed, disease-specific RVOT model was tested under three infant physiological conditions. Monocusps were sewn into models with the native main pulmonary artery (MPA) forming backwalls that constituted 40% and 50% of the reconstructed circumference for z-score zero PV annulus and MPA diameters (native PV z-score - 3.52 and - 2.99 for BSA 0.32m2). Various leaflet free edge lengths (FEL) (relative to backwall), positions (relative to PV STJ), and scallop depths were investigated across both models. Pressure gradient, regurgitation, and coaptation were analyzed with descriptive statistics and regression models. RESULTS: Increasing FEL beyond 100% of the MPA backwall decreased gradient but mildly increased regurgitation to a peak of 25%. Positioning the free edge 2 mm past the STJ mildly increased gradient for each FEL without significantly changing regurgitation compared to STJ placement. Scalloping leaflets trivially affected performance. Pre-folding leaflets improved mobility and slightly reduced gradient. CONCLUSIONS: Balancing gradient, regurgitation, and oversizing for growth, a set of leaflet designs have been selected for pre-clinical evaluation. Designs with leaflet widths 140-160% in the 40% backwall model (110-120% in the 50% backwall), positioned at or 2 mm past the STJ, demonstrated the best results. The next stage of ex-vivo testing will additionally consider native RVOT distensibility, native leaflet interactions, and TAP characteristics.


Assuntos
Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Lactente , Humanos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Ventrículos do Coração , Politetrafluoretileno , Resultado do Tratamento , Estudos Retrospectivos
4.
Eur J Cardiothorac Surg ; 64(5)2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37897688

RESUMO

OBJECTIVES: Thick-patch pulmonary homograft, autologous pericardium and CardioCel Neo are common patch materials for aortic arch reconstruction. Insufficient data exist on sutured patch strength and limits of use. We evaluated failure strength of these materials to develop a failure prediction model for clinical guidance. METHODS: Patch failure strength was evaluated via sutured uniaxial and burst pressure testing. In sutured uniaxial testing, patches were sutured to aortic or Dacron tabs and pulled to failure. In burst pressure testing, patches were sewn into porcine aortas or Dacron grafts and pressurized to failure. Failure membrane tension was calculated. A prediction model of membrane tension versus vessel diameter was generated to guide clinical patch selection. RESULTS: Combining sutured uniaxial and burst pressure test data, pulmonary homograft failure strength {0.61 [interquartile range (IQR): 0.44, 0.78] N/mm, n = 21} was less than half that of autologous pericardium [2.22 (IQR: 1.65, 2.78) N/mm, n = 15] and CardioCel Neo [1.31 (IQR: 1.20, 1.42) N/mm, n = 20]. Pulmonary homograft burst pressure [245 (IQR: 202, 343) mmHg, n = 7] was significantly lower than autologous pericardium [863 (IQR: 802, 919) mmHg, n = 6] and CardioCel Neo [766 (IQR: 721, 833) mmHg, n = 6]. Our model predicts failure limits for each patch material and outlines safety margins for combinations of aortic diameter and pressure. CONCLUSIONS: Sutured failure strength of thick-patch pulmonary homograft was significantly lower than autologous pericardium and CardioCel Neo. Patient selection (predicted postoperative arch diameter and haemodynamics) and blood pressure management must be considered when choosing patch material for arch reconstruction. In older children and adolescents, autologous or bovine pericardium may be more suitable materials for aortic patch augmentation to minimize the risk of postoperative patch failure.


Assuntos
Aorta Torácica , Polietilenotereftalatos , Criança , Humanos , Animais , Bovinos , Suínos , Adolescente , Aorta Torácica/cirurgia , Aorta , Pressão Sanguínea , Hemodinâmica , Pericárdio/transplante , Estudos Retrospectivos
5.
Cardiovasc Eng Technol ; 14(5): 640-654, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37580629

RESUMO

PURPOSE: Very high-risk, ductal-dependent or complex two-ventricle patients with associated comorbidities often require pulmonary blood flow restriction as bridge to a more definitive procedure, but current surgical options may not be well-tolerated. An evolving alternative utilizes a fenestrated Micro Vascular Plug (MVP) as a transcatheter, internal pulmonary artery band. In this study, we report a case series and an in-vitro evaluation of the MVP to elicit understanding of the challenges faced with device implantation. METHODS: Following single-center, retrospective review of eight patients who underwent device placement, an in-vitro flow study was conducted on MVP devices to assess impact of device and fenestration sizing on pulmonary blood flow. A mathematical model was developed to relate migration risk to vessel size. Results of the engineering analysis were compared to the clinical series for validation. RESULTS: At median follow-up of 8 months (range 1-15), survival was 63% (5/8), and 6 (75%) patients underwent subsequent target surgical intervention with relatively low mortality (1/6). Occluder-related challenges included migration (63%) and peri-device flow, which were evaluated in-vitro. The device demonstrated durability over normal and supraphysiologic conditions with minimal change in fenestration size. Smaller vessel size significantly increased pressure gradient due to reduced peri-device flow and smaller effective fenestration size. CONCLUSION: Device oversizing, with appropriate adjustment to fenestration size, may reduce migration risk and provide a clinically appropriate balance between resulting pressure gradient and Qp:Qs. Our results can guide the interventionalist in appropriately selecting the device and fenestrations based on patient-specific anatomy and desired post-implantation flow characteristics.


Assuntos
Cateterismo Cardíaco , Artéria Pulmonar , Recém-Nascido , Humanos , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
Cardiovasc Eng Technol ; 14(2): 217-229, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36456745

RESUMO

PURPOSE: Tetralogy of Fallot and other conditions affecting the right ventricular outflow tract (RVOT) are common in pediatric patients, but there is a lack of quantitative comparison among techniques for repairing or replacing the pulmonary valve. The aim of this study was to develop a robust in vitro system for quantifying flow conditions after various RVOT interventions. METHODS: An infant-sized mock circulatory loop that includes a 3D-printed RVOT anatomical model was developed to evaluate flow conditions after different simulated surgical repairs. Physiologically correct flow and pressure were achieved with custom compliant tubing and a tunable flow restrictor. Pressure gradient, flow regurgitation, and coaptation height were measured for two monocusp leaflet designs after tuning the system with a 12 mm Hancock valved conduit. RESULTS: Measurements were repeatable across multiple samples of two different monocusp designs, with the wider leaflet in the 50% backwall model consistently exhibiting lower pressure gradient but higher regurgitation compared to the leaflet in the 40% backwall model. Coaptation height was measured via direct visualization with endoscopic cameras, revealing a shorter area of contact for the wider leaflet (3.3-4.0 mm) compared to the narrower one (4.3 mm). CONCLUSION: The 3D-printed RVOT anatomical model and in vitro pulmonary circulatory loop developed in this work provide a platform for planning and evaluating surgical interventions in the pediatric population. Measurements of regurgitation, pressure gradient, and coaptation provide a quantitative basis for comparison among different valve designs and positions.


Assuntos
Próteses Valvulares Cardíacas , Valva Pulmonar , Tetralogia de Fallot , Obstrução do Fluxo Ventricular Externo , Lactente , Criança , Humanos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Ventrículos do Coração , Circulação Pulmonar , Resultado do Tratamento
7.
J Med Device ; 14(3): 031005, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32983314

RESUMO

A double-walled stent-graft (DWSG) design with a compressible gas layer was conceived with the goal of treating hypertension in patients receiving an aortic stent-graft. Early prototypes were developed to evaluate the design concept through static measurements from a finite element (FE) model and quasi-static inflation experiments, and through dynamic measurements from an in vitro flow loop and the three-element Windkessel model. The amount of gas in the gas layer and the properties of the flexible inner wall were the primary variables evaluated in this study. Properties of the inner wall had minimal effect on DWSG behavior, but increased gas charge led to increased fluid capacitance and larger reduction in peak and pulse pressures. In the flow loop, placement of the DWSG decreased pulse pressure by over 20% compared to a rigid stent-graft. Capacitance measurements were consistent across all methods, with the maximum capacitance estimated at 0.07 mL/mmHg for the largest gas charge in the 15 cm long prototype. Windkessel model predictions for in vivo performance of a DWSG placed in the aorta of a hypertensive patient showed pulse pressure reduction of 14% compared to a rigid stent-graft case, but pressures never returned to unstented values. These results indicate that the DWSG design has potential to be developed into a new treatment for hypertensive patients requiring an aortic intervention.

8.
J Biomech Eng ; 139(7)2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28334369

RESUMO

The von Mises (VM) stress is a common stress measure for finite element models of tissue mechanics. The VM failure criterion, however, is inherently isotropic, and therefore may yield incorrect results for anisotropic tissues, and the relevance of the VM stress to anisotropic materials is not clear. We explored the application of a well-studied anisotropic failure criterion, the Tsai­Hill (TH) theory, to the mechanically anisotropic porcine aorta. Uniaxial dogbones were cut at different angles and stretched to failure. The tissue was anisotropic, with the circumferential failure stress nearly twice the axial (2.67 ± 0.67 MPa compared to 1.46 ± 0.59 MPa). The VM failure criterion did not capture the anisotropic tissue response, but the TH criterion fit the data well (R2 = 0.986). Shear lap samples were also tested to study the efficacy of each criterion in predicting tissue failure. Two-dimensional failure propagation simulations showed that the VM failure criterion did not capture the failure type, location, or propagation direction nearly as well as the TH criterion. Over the range of loading conditions and tissue geometries studied, we found that problematic results that arise when applying the VM failure criterion to an anisotropic tissue. In contrast, the TH failure criterion, though simplistic and clearly unable to capture all aspects of tissue failure, performed much better. Ultimately, isotropic failure criteria are not appropriate for anisotropic tissues, and the use of the VM stress as a metric of mechanical state should be reconsidered when dealing with anisotropic tissues.


Assuntos
Estresse Mecânico , Animais , Anisotropia , Aorta Abdominal/citologia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Teste de Materiais , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...