Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Alzheimers Dis ; 49(3): 723-32, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26484924

RESUMO

BACKGROUND: Multiple neurological disorders including Alzheimer's disease (AD), mesial temporal sclerosis, and mild traumatic brain injury manifest with volume loss on brain MRI. Subtle volume loss is particularly seen early in AD. While prior research has demonstrated the value of this additional information from quantitative neuroimaging, very few applications have been approved for clinical use. Here we describe a US FDA cleared software program, NeuroreaderTM, for assessment of clinical hippocampal volume on brain MRI. OBJECTIVE: To present the validation of hippocampal volumetrics on a clinical software program. METHOD: Subjects were drawn (n = 99) from the Alzheimer Disease Neuroimaging Initiative study. Volumetric brain MR imaging was acquired in both 1.5 T (n = 59) and 3.0 T (n = 40) scanners in participants with manual hippocampal segmentation. Fully automated hippocampal segmentation and measurement was done using a multiple atlas approach. The Dice Similarity Coefficient (DSC) measured the level of spatial overlap between NeuroreaderTM and gold standard manual segmentation from 0 to 1 with 0 denoting no overlap and 1 representing complete agreement. DSC comparisons between 1.5 T and 3.0 T scanners were done using standard independent samples T-tests. RESULTS: In the bilateral hippocampus, mean DSC was 0.87 with a range of 0.78-0.91 (right hippocampus) and 0.76-0.91 (left hippocampus). Automated segmentation agreement with manual segmentation was essentially equivalent at 1.5 T (DSC = 0.879) versus 3.0 T (DSC = 0.872). CONCLUSION: This work provides a description and validation of a software program that can be applied in measuring hippocampal volume, a biomarker that is frequently abnormal in AD and other neurological disorders.


Assuntos
Doença de Alzheimer/diagnóstico , Hipocampo/patologia , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/métodos , Software , Idoso , Idoso de 80 Anos ou mais , Disfunção Cognitiva/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
Phys Rev Lett ; 100(9): 093006, 2008 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-18352707

RESUMO

Laser-aligned carbondisulfide (CS2) molecules are singly ionized by multiphoton absorption from intense, linearly polarized 25 fs laser pulses. The angular distribution of the photoelectrons exhibits a significant dependence on the angle between the polarizations of the aligning and ionizing laser fields. The widely used strong-field approximation predicts angular distributions in qualitative agreement with the experimental data but fails at a quantitative level.

3.
Phys Rev Lett ; 95(7): 073004, 2005 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-16196779

RESUMO

A model based on the strong-field and Born-Oppenheimer approximations qualitatively describes the distribution over vibrational states formed in a diatomic molecular ion following ionization of the neutral molecule by intense laser pulses. Good agreement is found with a recent experiment [X. Urbain et al., Phys. Rev. Lett. 92, 163004 (2004)]. In particular, the observed deviation from a Franck-Condon-like distribution is reproduced. Additionally, we demonstrate control of the vibrational distribution by a variation of the peak intensity or a change of frequency of the laser pulse.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...