Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hum Brain Mapp ; 39(9): 3558-3573, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29693304

RESUMO

Slow sinusoidal, hemodynamic oscillations (SSHOs) around 0.1 Hz are frequently seen in mammalian and human brains. In four patients undergoing epilepsy surgery, subtle but robust fluctuations in oxy- and deoxyhemoglobin were detected using hyperspectral imaging of the cortex. These SSHOs were stationary during the entire 4 to 10 min acquisition time. By Fourier filtering the oxy- and deoxyhemoglobin time signals with a small bandwidth, SSHOs became visible within localized regions of the brain, with distinctive frequencies and a continuous phase variation within that region. SSHOs of deoxyhemoglobin appeared to have an opposite phase and 11% smaller amplitude with respect to the oxyhemoglobin SSHOs. Although the origin of SSHOs remains unclear, we find indications that the observed SSHOs may embody a local propagating hemodynamic wave with velocities in line with capillary blood velocities, and conceivably related to vasomotion and maintenance of adequate tissue perfusion. Hyperspectral imaging of the human cortex during surgery allow in-depth characterization of SSHOs, and may give further insight in the nature and potential (clinical) use of SSHOs.


Assuntos
Ondas Encefálicas/fisiologia , Córtex Cerebral/fisiopatologia , Circulação Cerebrovascular , Epilepsia/fisiopatologia , Hemoglobinometria/métodos , Hemoglobinas/análise , Oxiemoglobinas/análise , Espectrofotometria/métodos , Adolescente , Córtex Cerebral/irrigação sanguínea , Epilepsia/cirurgia , Feminino , Análise de Fourier , Neuroimagem Funcional/métodos , Hemoglobinometria/instrumentação , Humanos , Processamento de Imagem Assistida por Computador , Período Intraoperatório , Masculino , Espectrofotometria/instrumentação , Adulto Jovem
2.
Burns ; 43(7): 1516-1523, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28536040

RESUMO

BACKGROUND: Objective measurement tools may be of great value to provide early and reliable burn wound assessment. Thermal imaging is an easy, accessible and objective technique, which measures skin temperature as an indicator of tissue perfusion. These thermal images might be helpful in the assessment of burn wounds. However, before implementation of a novel measurement tool into clinical practice is considered, it is appropriate to test its clinimetric properties (i.e. reliability and validity). The objective of this study was to assess the reliability and validity of the recently introduced FLIR ONE thermal imager. MATERIAL AND METHODS: Two observers obtained thermal images of burn wounds in adult patients at day 1-3, 4-7 and 8-10 after burn. Subsequently, temperature differences between the burn wound and healthy skin (ΔT) were calculated on an iPad mini containing the FLIR Tools app. To assess reliability, ΔT values of both observers were compared by calculating the intraclass correlation coefficient (ICC) and measurement error parameters. To assess validity, the ΔT values of the first observer were compared to the registered healing time of the burn wounds, which was specified into three categories: (I) ≤14 days, (II) 15-21 days and (III) >21 days. The ability of the FLIR ONE to discriminate between healing ≤21 days and >21 days was evaluated by means of a receiver operating characteristic curve and an optimal ΔT cut-off value. RESULTS: Reliability: ICCs were 0.99 for each time point, indicating excellent reliability up to 10 days after burn. The standard error of measurement varied between 0.17-0.22°C. VALIDITY: the area under the curve was calculated at 0.69 (95% CI 0.54-0.84). A cut-off value of -1.15°C shows a moderate discrimination between burn wound healing ≤21 days and >21 days (46% sensitivity; 82% specificity). CONCLUSION: Our results show that the FLIR ONE thermal imager is highly reliable, but the moderate validity calls for additional research. However, the FLIR ONE is pre-eminently feasible, allowing easy and fast measurements in clinical burn practice.


Assuntos
Queimaduras/diagnóstico por imagem , Pele/diagnóstico por imagem , Termografia/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Queimaduras/diagnóstico , Computadores de Mão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo , Cicatrização , Adulto Jovem
3.
Eur J Surg Oncol ; 40(10): 1222-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25108815

RESUMO

BACKGROUND: Although radiofrequency ablation (RFA) is promising for the local treatment of breast cancer, burns are a frequent complication. The safety and efficacy of a new technique with a bipolar RFA electrode was evaluated. METHODS: Dosimetry was assessed ex vivo in bovine mammary tissue, applying power settings of 5-15 W with 10-20 min exposure and 3.0-12.0 kJ to a 20-mm active length bipolar internally cooled needle-electrode. Subsequently, in 15 women with invasive breast carcinoma ≤2.0 cm diameter ultrasound-guided RFA was performed followed by immediate resection. RESULTS: An ablation zone of 2.5 cm was reached in the ex vivo experiments at 15 W at 9.0 kJ administered energy. Histopathology revealed complete cell death in 10 of 13 patients (77%); in 3 patients partial ablation was due to inaccurate probe positioning. In 1 patient a pneumothorax was caused by the probe placement, treated conservatively. No burns occurred. CONCLUSIONS: Ultrasound-guided RFA with a bipolar needle-electrode appears to be a safe local treatment technique for invasive breast cancer up to 2 cm. Ways to improve placement of the probe and direct monitoring of the ablation-effect should be the aim of further research.


Assuntos
Neoplasias da Mama/cirurgia , Queimaduras/prevenção & controle , Carcinoma Ductal de Mama/cirurgia , Ablação por Cateter/métodos , Idoso , Animais , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Ablação por Cateter/instrumentação , Bovinos , Eletrodos , Desenho de Equipamento , Feminino , Humanos , Glândulas Mamárias Animais , Pessoa de Meia-Idade
4.
Eur Radiol ; 21(8): 1733-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21432022

RESUMO

OBJECTIVES: To assess the feasibility of computed tomography (CT) based thermometry during interstitial laser heating in the bovine liver. METHODS: Four freshly exercised cylindrical blocks of bovine tissue were heated using a continuous laser of Nd:YAG (wavelength: 1064 nm, active length: 30 mm, power: 10-30 W). All tissues were imaged at least once before and 7 times during laser heating using CT and temperatures were simultaneously measured with 5 calibrated thermal sensors. The dependency of the average CT numbers as a function of temperature was analysed with regression analysis and a CT thermal sensitivity was derived. RESULTS: During laser heating, the growing hypodense area was observed around the laser source and that area showed an increase as a function of time. The formation of hypodense area was caused by declining in CT numbers at increasing temperatures. The regression analysis showed an inverse linear dependency between temperature and average CT number with -0.65 ± 0.048 HU/°C (R(2) = 0.75) for the range of 18-85°C in bovine liver. CONCLUSIONS: The non-invasive CT based thermometry during interstitial laser heating is feasible in the bovine liver. CT based thermometry could be further developed and may be of potential use during clinical LITT of the liver.


Assuntos
Ablação por Cateter/métodos , Hipertermia Induzida , Lasers de Estado Sólido , Fígado/diagnóstico por imagem , Fígado/cirurgia , Tomografia Computadorizada por Raios X/métodos , Animais , Bovinos , Estudos de Viabilidade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Análise de Regressão
5.
Arch Dis Child Fetal Neonatal Ed ; 95(1): F53-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19679893

RESUMO

BACKGROUND: In preterm infants with respiratory distress syndrome (RDS) nasal continuous positive airway pressure (nCPAP) with the "InSurE" procedure (intubation, surfactant, extubation) is increasingly used. However, its effect on cerebral oxygenation and brain function is not known. OBJECTIVE: To evaluate the effects of the "InSurE" procedure in infants with RDS on regional cerebral oxygen saturation (rScO(2)) and relative cerebral fractional tissue oxygen extraction (cFTOE) using near infrared spectroscopy and on electrical brain activity using amplitude-integrated electroencephalography (aEEG). METHODS: Sixteen infants with RDS, treated with the "InSurE" procedure, and 16 matched controls with nCPAP, were monitored for mean arterial blood pressure (MABP), arterial oxygen saturation (SaO(2)), rScO(2), cFTOE and aEEG. Ten-minute periods were selected and averaged at 120 and 20 minutes before, during the procedure and at 30 minutes, 1, 2, 6, 12 and 24 h after the start of the "InSurE" procedure. aEEG was analysed by quantitative and qualitative (Burdjalov score) methods. RESULTS: MABP was not different between groups on all time points. rScO(2) and cFTOE were comparable between groups, but there was a trend towards lower rScO(2) and higher cFTOE 30 minutes after opioid administration in the "InSurE" infants compared with controls (62% (SD 11) vs 68% (SD 10) and 0.30 (SD 0.10 ) vs 0.28 (SD 0.11), respectively). aEEG amplitudes and Burdjalov scores were significantly lower in "InSurE" infants from 30 minutes after opioid administration up to 24 h after the start of the procedure (p<0.05). CONCLUSION: In the present study, the "InSurE" procedure did not induce perturbation of cerebral oxygen delivery and extraction, whereas electrical brain activity decreased for a prolonged period of time.


Assuntos
Analgésicos Opioides/uso terapêutico , Encéfalo/metabolismo , Eletroencefalografia , Oxigênio/metabolismo , Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Pressão Sanguínea/fisiologia , Estudos de Casos e Controles , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Intubação Intratraqueal , Masculino , Monitorização Fisiológica , Naloxona/uso terapêutico , Antagonistas de Entorpecentes/uso terapêutico , Estudos Prospectivos , Síndrome do Desconforto Respiratório do Recém-Nascido/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos
6.
Ann Surg Oncol ; 16(8): 2259-63, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19506958

RESUMO

BACKGROUND: The next step in breast-conserving surgery for small breast carcinomas could be local ablation. In this study, the feasibility of ultrasound-guided laser-induced thermal therapy (LITT) is evaluated. METHODS: Patients with large-core needle biopsy-proven invasive, palpable breast carcinoma (clinically or=2 cm in size (P = .026). CONCLUSIONS: Successful LITT of invasive breast cancer seems to be feasible when confined to small (<2 cm) nonlobular carcinomas without surrounding extensive in-situ component and angioinvasion. However, to implement LITT in a curative setting, improvements in imaging to more reliably preoperatively assess tumor size and monitoring of fiber tip placement and treatment affect are essential.


Assuntos
Neoplasias da Mama/terapia , Carcinoma Ductal de Mama/terapia , Carcinoma Lobular/terapia , Hipertermia Induzida/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Estudos de Viabilidade , Feminino , Humanos , Terapia a Laser , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Prognóstico , Taxa de Sobrevida , Resultado do Tratamento , Ultrassonografia de Intervenção , Ultrassonografia Mamária
7.
Biol Neonate ; 90(3): 197-202, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16717443

RESUMO

BACKGROUND: Midazolam sedation and morphine analgesia are commonly used in ventilated premature infants. OBJECTIVES: To evaluate the effects of midazolam versus morphine infusion on cerebral oxygenation and hemodynamics in ventilated premature infants. METHODS: 11 patients (GA 26.6-33.0 weeks, BW 780-2,335 g) were sedated with midazolam (loading dose 0.2 mg/kg, maintenance 0.2 mg/kg/h) and 10 patients (GA 26.4-33.3 weeks, BW 842-1,955 g) were sedated with morphine (loading dose 0.05 mg/kg, maintenance 0.01 mg/kg/h). Changes in oxyhemoglobin (Delta cO2Hb) and deoxyhemoglobin (Delta cHHb) were assessed using near infrared spectrophotometry. Changes in cHbD (= Delta cO(2)Hb - Delta cHHb) reflect changes in cerebral blood oxygenation and changes in concentration of total hemoglobin (Delta ctHb = Delta cO2Hb + Delta cHHb) represent changes in cerebral blood volume (DeltaCBV). Changes in cerebral blood flow velocity (DeltaCBFV) were intermittently measured using Doppler ultrasound. Heart rate (HR), mean arterial blood pressure (MABP), arterial oxygen saturation (saO2) and transcutaneous measured pO2 (tcpO2) and pCO2 (tcpCO2) were continuously registered. Statistical analyses were carried out using linear mixed models to account for the longitudinal character study design. RESULTS: Within 15 min after the loading dose of midazolam, a decrease in saO2, tcpO2 and cHbD was observed in 5/11 infants. In addition, a fall in MABP and CBFV was observed 15 min after midazolam administration. Immediately after morphine infusion a decrease in saO2, tcpO2 and cHbD was observed in 6/10 infants. Furthermore, morphine infusion resulted in a persistent increase in CBV. CONCLUSIONS: Administration of midazolam and morphine in ventilated premature infants causes significant changes in cerebral oxygenation and hemodynamics, which might be harmful.


Assuntos
Encéfalo/irrigação sanguínea , Recém-Nascido Prematuro , Midazolam/efeitos adversos , Morfina/efeitos adversos , Oxigênio/sangue , Respiração Artificial , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea/efeitos dos fármacos , Volume Sanguíneo/efeitos dos fármacos , Idade Gestacional , Frequência Cardíaca/efeitos dos fármacos , Hemoglobinas/análise , Humanos , Hipnóticos e Sedativos/administração & dosagem , Hipnóticos e Sedativos/efeitos adversos , Hipóxia Encefálica , Recém-Nascido , Midazolam/administração & dosagem , Morfina/administração & dosagem , Oxiemoglobinas/análise , Espectroscopia de Luz Próxima ao Infravermelho
8.
Biol Neonate ; 90(2): 122-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16569929

RESUMO

BACKGROUND: Sodium bicarbonate (NaHCO3) is often used for correction of metabolic acidosis in preterm infants. The effects of NaHCO3 administration on cerebral hemodynamics and oxygenation are not well known. Furthermore, there is no consensus on infusion rate of NaHCO3. OBJECTIVES: To evaluate the effects of rapid versus slow infusion of NaHCO3 on cerebral hemodynamics and oxygenation in preterm infants. METHODS: Twenty-nine preterm infants with metabolic acidosis were randomized into two groups (values are mean +/-SD): In group A (GA 30.5 +/- 1.7 weeks, b.w. 1,254 +/- 425 g) NaHCO3 4.2% was injected as a bolus. In group B (GA 30.3 +/- 1.8 weeks, b.w. 1,179 +/- 318 g) NaHCO3 4.2% was administered over a 30-min period. Concentration changes of oxyhemoglobin (cO2Hb) and deoxyhemoglobin (cHHb) were assessed using near infrared spectrophotometry. Changes in HbD (= cO2Hb - cHHb) represent changes in cerebral blood oxygenation and changes in ctHb (= cO2Hb + cHHb) reflect changes in cerebral blood volume. Cerebral blood flow velocity was intermittently measured using Doppler ultrasound. Longitudinal data analysis was performed using linear mixed models (SAS procedure MIXED), to account for the fact that the repeated observations in each individual were correlated. RESULTS: Administration of NaHCO3 resulted in an increase of cerebral blood volume which was more evident if NaHCO3 was injected rapidly than when infused slowly. HbD and cerebral blood flow velocity did not show significant changes in either group. CONCLUSION: To minimize fluctuations in cerebral hemodynamics, slow infusion of sodium bicarbonate is preferable to rapid injection.


Assuntos
Acidose/tratamento farmacológico , Volume Sanguíneo/efeitos dos fármacos , Encéfalo/irrigação sanguínea , Carbonatos/administração & dosagem , Recém-Nascido Prematuro/fisiologia , Volume Sanguíneo/fisiologia , Encéfalo/fisiologia , Carbonatos/farmacologia , Carbonatos/uso terapêutico , Relação Dose-Resposta a Droga , Humanos , Recém-Nascido , Infusões Intravenosas , Injeções Intravenosas , Fluxo Sanguíneo Regional/efeitos dos fármacos , Fluxo Sanguíneo Regional/fisiologia , Fatores de Tempo
9.
Physiol Meas ; 24(4): N35-40, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14658786

RESUMO

This paper describes the simultaneous use of two, noninvasive, near-infrared techniques near-infrared spectroscopy (NIRS) and a continuous wave NIR laser Doppler flow system (LDF) to measure changes in the blood oxygenation, blood concentration and blood flow velocity in the brain. A piglet was used as animal model. A controlled change in the arterial CO2 pressure (PaCO2) was applied for achieving changes in the listed cerebrovascular parameters. The time courses of blood concentration parameters (NIRS) and RMS blood flow velocity (LDF) were found to correspond closely with those of carotid blood flow and arterial carbon dioxide pressure (PaCO2). This result shows the additional value of LDF when combined with NIRS, preferably in one instrument. Development of pulsed LDF for regional blood flow measurement is indicated.


Assuntos
Circulação Cerebrovascular/fisiologia , Animais , Pressão Sanguínea/fisiologia , Química Encefálica/efeitos dos fármacos , Dióxido de Carbono/farmacologia , Artérias Carótidas/fisiologia , Circulação Cerebrovascular/efeitos dos fármacos , Cromatografia Gasosa , Frequência Cardíaca/fisiologia , Hipercapnia/fisiopatologia , Fluxometria por Laser-Doppler , Oxigênio/sangue , Consumo de Oxigênio/efeitos dos fármacos , Consumo de Oxigênio/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho , Suínos , Vasodilatação/efeitos dos fármacos
10.
Ultrasound Med Biol ; 29(9): 1253-60, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14553801

RESUMO

This study tested the hypothesis that changes in the blood concentration, and possibly in the perfusion, of different areas in the brain can be assessed by the use of ultrasound contrast agent (CA) and (linear) echo densitometry. The experiments were performed with piglets (n=3) under general anesthesia and artificial ventilation. Ultrasound CA was administered through a femoral vein as a short bolus. First passage wash-in curve was measured from image gray level during continuous low level (mechanical index<0.2) ultrasound imaging. This curve was obtained from 1-cm2 areas of the cortex (surface), the brain stem (inner) and the left carotid artery (vessel). Cerebral hemoglobin concentration changes were measured with near-infrared spectroscopy (NIRS). This approach enabled a cross-validation of these techniques. The measurements were repeated under conditions of normocapnia, mild hypercapnia and deep hypercapnia. Several physiologic signals, as well as the carotid blood flow, were measured simultaneously and related to gray level by linear regression analysis. The most significant results found were a high R2-statistic of the regression of the percentage change of the peak of the surface and inner wash-in curves with the arterial carbon dioxide pressure (R2=0.63 and R2=0.70, respectively), the blood pH (R2=0.79 and R2=0.81), the carotid flow (R2=0.75 and R2=0.72) and the partial arterial oxygen pressure (R2=0.47 and R2=0.55). Finally, a high correlation of peak gray level with total hemoglobin concentration change, independently measured by NIRS, was found (R2=0.69). In conclusion, these experiments show a reasonable intersubject variability of various relative measures derived from gray level ultrasound wash-in curves. High sensitivity to physiologic changes related to hypercapnia was observed for the peak contrast of wash-in curves. For up-slope and area-under-the-curve (first passage) this was lower but still highly significant. The gray-level ultrasound measures are highly correlated to changes in regional hemoglobin concentration in brain tissue assessed by NIRS.


Assuntos
Circulação Cerebrovascular , Ultrassonografia Doppler Transcraniana/métodos , Animais , Dióxido de Carbono/sangue , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/fisiologia , Hemoglobinas/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Modelos Lineares , Masculino , Oxigênio/sangue , Pressão Parcial , Fosfolipídeos , Espectroscopia de Luz Próxima ao Infravermelho , Hexafluoreto de Enxofre , Suínos
11.
Technol Health Care ; 11(1): 53-60, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12590158

RESUMO

OBJECTIVES: in vitro assessment of the reproducibility and the optimal separation and position of the optodes in continuous wave (CW-) NIRS measurement of local inhomogeneities in absorption and/or scattering. METHODS: a CW- NIRS system (OXYMON) was used with laser diodes at wavelengths of 767 nm, 845 nm, 905 nm, 945 nm and 975 nm. For practical considerations (dimensions of neonatal head) the measurements were performed on a cylindrical tissue-equivalent phantom (70 mm diameter of base material with mua = 0.01 mm(-1) (800 nm) and mu's = 1.00 mm(-1) (800 nm)), containing rods with 10 x absorption, or 10 x scattering, and 5 x both Monte Carlo simulations were carried out of a cylinder with transport scattering coefficient mu's = 0.525 mm(-1) and absorption coefficient mua = 0.075 mm(-1) and two optode positions. RESULTS: reproducibility of repeated measurements (n = 10) was +/- 0.005 OD. Maximum OD in case of absorbing rod, and of absorbing + scattering rod was measured with optodes separated by 90 degrees and rod position angle symmetrically (45 degrees ) in between. Minimum OD for these rods was obtained with optodes at 150 degrees angle and rod position at 240 degrees (i.e. relative to transmitting optode position at 0 degrees ). A second maximum OD was obtained at an optode angle 180 degrees and rod position at 180 degrees. Maximum OD (i.e. attenuation) for the scattering rod was at optode separation angle of 90 degrees and rod at 0 degrees. Minimum OD for this case was obtained with optode angle of 180 degrees and rod positions around 80 degrees and 280 degrees. Maximum OD changes by absorbing rod were in the order of +0.12 OD and -0.04 OD, respectively. Simulations at an optode separation angle of 90 degrees showed a spatial sensitivity path enclosing the rod position at maximum absorption found experimentally. CONCLUSIONS: when considering the phantom as a realistic geometrical model for the neonatal head, it can be concluded that the optode position at 90 degrees angle would be optimal for detecting an inhomogeneity at 15 mm depth, i.e. the location of the periventricular white matter. Since the rods are relatively strongly different from the base material the question remains to be answered whether local ischemia, which might lead to irreversible brain damage, can be detected by CW-NIRS


Assuntos
Espectrofotometria Infravermelho/métodos , Simulação por Computador , Desenho de Equipamento , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Leucomalácia Periventricular/diagnóstico , Método de Monte Carlo , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...