3.
JACC Heart Fail ; 11(8 Pt 2): 1103-1117, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36939661

RESUMO

BACKGROUND: Many patients with heart failure and preserved ejection fraction have no overt volume overload and normal resting left atrial (LA) pressure. OBJECTIVES: This study sought to characterize patients with normal resting LA pressure (pulmonary capillary wedge pressure [PCWP] <15 mm Hg) but exercise-induced left atrial hypertension (EILAH). METHODS: The REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc. IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) trial randomized 626 patients with ejection fraction ≥40% and exercise PCWP ≥25 mm Hg to atrial shunt or sham procedure. The primary trial outcome, a hierarchical composite of death, heart failure hospitalization, intensification of diuretics, and change in health status was compared between patients with EILAH and those with heart failure and resting left atrial hypertension (RELAH). RESULTS: Patients with EILAH (29%) had similar symptom severity, but lower natriuretic peptide levels, higher 6-minute walk distance, less atrial fibrillation, lower left ventricular mass, smaller LA volumes, lower E/e', and better LA strain. PCWP was lower at rest, but had a larger increase with exercise in EILAH. Neither group as a whole had a significant effect from shunt therapy vs sham. Patients with EILAH were more likely to have characteristics associated with atrial shunt responsiveness (peak exercise pulmonary vascular resistance <1.74 WU) and no pacemaker (63% vs 46%; P < 0.001). The win ratio for the primary outcome was 1.56 (P = 0.08) in patients with EILAH and 1.51 (P = 0.04) in those with RELAH when responder characteristics were present. CONCLUSIONS: Patients with EILAH had similar symptom severity but less advanced myocardial and pulmonary vascular disease. This important subgroup may be difficult to diagnose without invasive exercise hemodynamics, but it has characteristics associated with favorable response to atrial shunt therapy. (A Study to Evaluate the Corvia Medical, Inc. IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure [REDUCE LAP-HF TRIAL II]; NCT03088033).


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Hipertensão , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Volume Sistólico/fisiologia , Função Ventricular Esquerda
4.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958391

RESUMO

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
7.
JACC Cardiovasc Interv ; 13(12): 1391-1402, 2020 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-32473887

RESUMO

Although drug-eluting stents are still the default interventional treatment of coronary artery disease, drug-coated balloons (DCBs) represent a novel alternative therapeutic strategy in certain anatomic conditions. The effect of DCBs is based on the fast and homogenous transfer of antiproliferative drugs into the vessel wall during single balloon inflation by means of a lipophilic matrix without the use of permanent implants. Although their use is established for in-stent restenosis of both bare-metal and drug-eluting stents, recent randomized clinical data demonstrate a good efficacy and safety profile in de novo small-vessel disease and high bleeding risk. In addition, there are other emerging indications (e.g., bifurcation lesions, large-vessel disease, diabetes mellitus, acute coronary syndromes). Because the interaction among the different delivery balloon designs, doses, formulations, and release kinetics of the drugs used is important, there seems to be no "class effect" of DCBs. On the basis of the amount of recently published data, the International DCB Consensus Group provides this update of previous recommendations summarizing the historical background, technical considerations such as choice of device and implantation technique, possible indications, and future perspectives.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/farmacocinética , Tomada de Decisão Clínica , Consenso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos , Desenho de Equipamento , Humanos , Fatores de Risco , Resultado do Tratamento
8.
J Am Coll Cardiol ; 75(9): 1017-1028, 2020 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-32138961

RESUMO

BACKGROUND: Drug-coated balloons (DCBs) are accepted treatment strategies for coronary in-stent restenosis and are under clinical investigation for lesions without prior stent implantation. A recently published meta-analysis suggested an increased risk of death associated with the use of paclitaxel-coated devices in the superficial femoral artery. The reasons are incompletely understood as potential underlying pathomechanisms remain elusive, and no relationship to the administered dose has been documented. OBJECTIVES: The purpose of this analysis was to investigate the available data on survival after coronary intervention with paclitaxel-coated balloons from randomized controlled trials (RCTs). METHODS: PubMed, Web of science, and the Cochrane library database were searched, and a meta-analysis from RCT was performed comparing DCB with non-DCB devices (such as conventional balloon angioplasty, bare-metal stents, or drug-eluting stents) for the treatment of coronary in-stent restenosis or de novo lesions. The primary outcome was all-cause death. The number of patients lost to follow-up was observed at different time points. Risk estimates are reported as risk ratios (RRs) with 95% confidence intervals (CIs). RESULTS: A total of 4,590 patients enrolled in 26 RCTs published between 2006 and 2019 were analyzed. At follow-up of 6 to 12 months, no significant difference in all-cause mortality was found, however, with numerically lower rates after DCB treatment (RR: 0.74; 95% CI: 0.51 to 1.08; p = 0.116). Risk of death at 2 years (n = 1,477, 8 RCTs) was similar between the 2 groups (RR: 0.84; 95% CI: 0.51 to 1.37; p = 0.478). After 3 years of follow-up (n = 1,775, 9 RCTs), all-cause mortality was significantly lower in the DCB group when compared with control treatment (RR: 0.73; 95% CI: 0.53 to 1.00; p = 0.047) with a number needed to treat of 36 to prevent 1 death. A similar reduction was seen in cardiac mortality (RR: 0.53; 95% CI: 0.33 to 0.85; p = 0.009). CONCLUSIONS: In this meta-analysis, the use of paclitaxel DCBs for treatment of coronary artery disease was not associated with increased mortality, as has been suggested for peripheral arteries. On the contrary, use of coronary paclitaxel-coated balloons was associated with a trend toward lower mortality when compared with control treatments.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Antineoplásicos Fitogênicos/administração & dosagem , Paclitaxel/administração & dosagem , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
11.
Circ J ; 81(10): 1484-1489, 2017 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-28450663

RESUMO

BACKGROUND: Despite several negative prospective randomized trials on the efficacy of patent foramen ovale (PFO) occlusion, the discussion on indications is ongoing. Because the incidence of paradoxical coronary embolism through a PFO is unknown, we investigated the risk of paradoxical embolic myocardial infarction over a period of 13 years.Methods and Results:We conducted a retrospective and a prospective study. In the former, we searched the hospital database of a tertiary referral center for cases of acute myocardial infarction (AMI) during the past 10 years and screened them for possible paradoxical MIs. On this basis we started a prospective evaluation over 39 months in another tertiary referral center. All patients with AMI and normal coronary arteries were screened for PFO and if no other reason for the AMI could be found, the case was judged as presumed paradoxical embolism. In the retrospective analysis we found 22 cases (0.45%) of presumed paradoxical coronary artery embolism under 4,848 AMI. In the prospective study there were 11 presumed paradoxical coronary artery embolisms among 1,654 patients with AMI, representing an incidence of 0.67%. CONCLUSIONS: Our findings demonstrated that well below 1% of AMIs are caused by paradoxical embolism via an interatrial communication. Although this percentage appears low, it is not a negligible number of patients based on the huge number of MIs occurring in the industrialized world.


Assuntos
Embolia Paradoxal/complicações , Forame Oval Patente/fisiopatologia , Infarto do Miocárdio/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos , Adulto Jovem
12.
Int J Cardiol ; 225: 262-267, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27741486

RESUMO

BACKGROUND: Chronic total occlusions remain one of the biggest challenges for interventional cardiologists and the high risk of restenosis and stent thrombosis is still a major problem. Drug-coated balloons showed favorable results for the treatment of in-stent restenosis and other lesion types. The aim of this study was to evaluate the feasibility and outcome of a drug-coated balloon only approach for chronic total occlusion. METHODS: We included 34 patients with a native chronic total occlusion treated only by drug-coated balloons. A visual residual stenosis of 30% or less without major dissection was considered a satisfactory percutaneous intervention result according to the German Consensus Group recommendations for drug-coated balloon use. We collected clinical and procedural data. Angiograms were conducted during the procedure and at follow-up. Quantitative coronary analysis was performed and mean and minimal lumen diameter and late luminal changes were assessed. RESULTS: The recanalization was considered satisfactory in 79.4% (n=27). Restenosis occurred in 11.8% (n=4) and reocclusion in 5.9% (n=2). Out of the 27 patients with a satisfactory initial result, 3.7% (n=1) had reocclusion and 3.7% (n=1) had restenosis. In the subgroup without satisfactory result (n=7), restenosis occurred in 3 patients (42.9%) and reocclusion in 1 patient (14.3%). A luminal increase was found in 67.6% (n=23) and mean late luminal gain was 0.11±0.49mm. Angina class improved significantly (p<0.001). There was no death or myocardial infarction. CONCLUSIONS: Drug-coated balloon angioplasty without stenting is a feasible and well-tolerated treatment method for chronic total occlusions if the predilatation result is good.


Assuntos
Angioplastia Coronária com Balão/métodos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Stents Farmacológicos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doença Crônica , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Resultado do Tratamento
13.
Circ Heart Fail ; 9(7)2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27330010

RESUMO

UNLABELLED: Heart failure with preserved ejection fraction (HFpEF), a major public health problem with high morbidity and mortality rates, remains difficult to manage because of a lack of effective treatment options. Although HFpEF is a heterogeneous clinical syndrome, elevated left atrial pressure-either at rest or with exertion-is a common factor among all forms of HFpEF and one of the primary reasons for dyspnea and exercise intolerance in these patients. On the basis of clinical experience with congenital interatrial shunts in mitral stenosis, it has been hypothesized that the creation of a left-to-right interatrial shunt to decompress the left atrium (without compromising left ventricular filling or forward cardiac output) is a rational, nonpharmacological strategy for alleviating symptoms in patients with HFpEF. A novel transcatheter interatrial shunt device has been developed and evaluated in patients with HFpEF in single-arm, nonblinded clinical trials. These studies have demonstrated the safety and potential efficacy of the device. However, a randomized, placebo-controlled evaluation of the device is required to further evaluate its safety and efficacy in patients with HFpEF. In this article, we give the rationale for a therapeutic transcatheter interatrial shunt device in HFpEF, and we describe the design of REDUCE Elevated Left Atrial Pressure in Heart Failure (REDUCE LAP-HF I), the first randomized controlled trial of a device-based therapy to reduce left atrial pressure in HFpEF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02600234.


Assuntos
Função do Átrio Esquerdo , Pressão Atrial , Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/terapia , Coração Auxiliar , Cateterismo Cardíaco/efeitos adversos , Protocolos Clínicos , Europa (Continente) , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Projetos de Pesquisa , Método Simples-Cego , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular Esquerda
14.
Clin Res Cardiol ; 105(7): 613-21, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26768146

RESUMO

OBJECTIVES: We set out to investigate the benefit of distal main or side branch treatment with a DCB compared to POBA in coronary bifurcation lesions. BACKGROUND: The standard treatment of bifurcation lesions is application of a DES to the main branch with provisional side branch stenting. While this resulted in considerable improvement in overall MACE rate suboptimal side branch results remained a problem. METHODS: The study was performed from 2011 to 2013 in six German centers. Native bifurcation lesions were included if side branch vessel diameter was ≥2 and ≤3.5 mm and no proximal main branch lesions was found. After successful predilatation randomization was performed to either DCB application or no further treatment. Follow-up angiograms for QCA analysis were done after 9 months. Primary endpoint was late lumen loss (LLL). RESULTS: 64 patients were successfully randomized. Minimal lumen diameter and grade of stenosis were equal in both groups. Only five stents were used as bail out. Angiographic follow-up was achieved in 75 % of patients. No patient died. There was one NSTEMI in the POBA group. Restenosis rate was 6 % in the DCB group vs 26 % in the POBA group (p = 0.045). TLR was necessary in one patient of the DCB group vs three patients of the POBA. The primary endpoint LLL was 0.13 mm in the DCB vs 0.51 mm in the POBA group (p = 0.013). CONCLUSION: In bifurcation lesions that show only class A or B dissection and recoil not beyond 30 % the use of DCBs is a sound strategy.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Estenose Coronária/terapia , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Índice de Gravidade de Doença , Stents , Fatores de Tempo , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 88(2): 193-200, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26423017

RESUMO

OBJECTIVES: To assess the safety and efficacy of fractional flow reserve (FFR) guided paclitaxel-coated balloon (PCB) treatment for de novo coronary artery lesions. BACKGROUND: There is limited data on PCB treatment for de novo lesions especially of major epicardial coronary arteries. METHODS: Sixty-six patients with 67 de novo lesions who underwent successful plain old balloon angioplasty (POBA) were included. If POBA-FFR was favorable (≥ 0.85), PCB was applied and if POBA-FFR was <0.85, stent implantation was preferred over PCB. RESULTS: Forty-five lesions were treated with PCB (67.2%) and 22 lesions with stents (32.8%). Dual antiplatelet therapy duration was 6 weeks. Late luminal loss with PCB was significantly less than stent (0.05 ± 0.27 mm vs. 0.40 ± 0.54 mm, P = 0.022). The baseline FFR of target lesions was 0.69 ± 0.16 in PCB and 0.60 ± 0.11 in stent group (P = 0.015), however, the FFR at 9 months was not different between groups (0.85 ± 0.08 in PCB vs. 0.85 ± 0.05 in stent group, P = 0.973). At 1 year, one myocardial infarction and one target lesion revascularization related to in-stent restenosis were detected, both in the stent group. CONCLUSION: POBA-FFR-guided PCB treatment is safe and effective for de novo coronary lesions with good anatomical and physiological patency at mid-term follow-up. © 2015 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Reserva Fracionada de Fluxo Miocárdico/efeitos dos fármacos , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/etiologia , Vasos Coronários/fisiopatologia , Quimioterapia Combinada , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Paclitaxel/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , República da Coreia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular/efeitos dos fármacos
17.
J Invasive Cardiol ; 27(2): 93-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25661760

RESUMO

OBJECTIVES: Mortality rates remain high in patients with cardiogenic shock or acute refractory circulatory failure. Extracorporeal life support (ECLS) has been recently introduced into clinical practice for treatment of refractory hypotension in selected patients in combination with rapid restoration of gas exchange. The aim of this study was to evaluate the procedural performance and safety of the automated Lifebridge ECLS system (Zoll Lifebridge GmbH). METHODS: A total of five tertiary cardiovascular centers located in Germany contributed data to this registry (n = 54 patients). Data were collected using a standardized case report form to record clinical characteristics, demographic, procedural, and follow-up data. Patients were included if they were in circulatory crisis (caused by cardiogenic shock or ongoing resuscitation) in an acute setting or in an elective setting during high-risk percutaneous intervention. RESULTS: The Lifebridge device was successfully used in all patients. During elective use, no complications occurred besides 1 minor vascular injury. All elective patients were successfully weaned from the device and alive at the primary endpoint after 30 days. In the emergency setting, 85% of the patients were successfully weaned from the device and 49% of the patients were alive after 30 days. Relevant bleeding resulting in transfusion of red blood cells occurred in 5% of patients. CONCLUSION: In this observational study, we report data from the real-world use of a novel automated ECLS system. Elective use of Lifebridge was feasible and safe without major side effects. In the emergency setting, mortality rates were high; however, stabilization of the selected patients was safe and feasible.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Sistema de Registros , Choque Cardiogênico/terapia , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Estudos Retrospectivos , Choque Cardiogênico/mortalidade , Taxa de Sobrevida/tendências
18.
Catheter Cardiovasc Interv ; 86(7): 1151-60, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25683225

RESUMO

OBJECTIVES: To assess the safety and efficacy of Biolimus A9-eluting stents (BES, BioMatrix™ and BioMatrix Flex™) in routine clinical practice. BACKGROUND: The LEADERS randomized trial has documented equivalent efficacy and superior safety of the BES when compared to a first generation Sirolimus-eluting Cypher(TM) stent. METHODS: 5,472 patients from 57 centers, treated with BES, were enrolled in an international multicenter registry and followed clinically up to 2 years. RESULTS: Mean patient age was 63.2 ± 11 years, 24% of patients had diabetes, and 49.8% presented with an acute coronary syndrome. 99.3% of patients were discharged on dual antiplatelet therapy (DAPT), 83.3% remained on DAPT at 1 year and 30.6% at 2 years. The incidence of the composite primary end point [major adverse cardiac events (MACE) at 12 months] was 4.5% [cardiac death 0.9%, myocardial infarction 1.7%, clinically indicated target vessel revascularization (ci-TVR) 2.8%]. MACE incidence was 6.8% at 24 months (cardiac death 1.5%, myocardial infarction 2.4%, ci-TVR 4.3%). At 12 months, 32 patients (0.6%) had suffered at least one definite or probable stent thrombosis (ST), and 91 patients (1.7%) a major bleed (MB). Nine patients with ST (27.3%) and 7 patients with a MB (7.7%) died during the first year after the index procedure. Between 12 and 24 months after implantation, there were 18 (0.4%) additional MB and 8 (0.2%) additional ST. CONCLUSIONS: This large international cohort documents a low 12 and 24 months MACE incidence and a very low ST incidence in an unselected patient population undergoing BES implantation. The results are in keeping with those of the randomized controlled LEADERS trial. Even though ST with this stent was a rare event, it was still associated with significant mortality. MB remains a problem, and warrants improved tailoring of DAPT in recipients of drug eluting stents.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Comorbidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Quimioterapia Combinada , Feminino , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/uso terapêutico , Modelos de Riscos Proporcionais , Sistema de Registros , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
19.
EuroIntervention ; 11(8): 926-34, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25169589

RESUMO

AIMS: Treatment of bare metal in-stent restenosis with the paclitaxel-coated balloon catheter based on the PACCOCATH® technology has yielded superior six-month angiographic and one-year clinical results compared to a paclitaxel-eluting stent. The three-year clinical follow-up is presented. METHODS AND RESULTS: One hundred and thirty-one patients with coronary bare metal in-stent restenosis (>70%, length: <22 mm, vessel diameter: 2.5-3.5 mm) were randomly treated with the paclitaxel-coated balloon (DCB) (3 µg/mm²) or a paclitaxel-eluting stent (DES). Clinical follow-up information was requested from the patients and from their physicians. Quantitative angiographic and demographic baseline data were statistically not different between the groups. Per intention-to-treat analysis at 12 months, the lesion-related rates of major adverse cardiac events were 7.6% and 16.9% (p=0.11) while at 36 months the respective numbers were 9.1% and 18.5% (p=0.14). These differences were primarily due to reduced target lesion revascularisation (TLR) in DCB 4/66 (6.2%) compared to DES patients 10/65 (15.4%) (p=0.10). From 12 to 36 months, 1/65 (1.5%) DCB patients experienced a myocardial infarction while neither TLR nor death occurred in any study patient in either group during that period. CONCLUSIONS: The six-month superiority of the paclitaxel-coated balloon compared to the paclitaxel-eluting stent in the treatment of bare metal coronary in-stent restenosis persisted throughout the three-year clinical follow-up period indicating stability of the lesions treated. (ClinicalTrials.gov Identifier: NCT00393315).


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Stents , Dispositivos de Acesso Vascular , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Intervalo Livre de Doença , Feminino , Alemanha , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Metais , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Desenho de Prótese , Retratamento , Fatores de Tempo , Resultado do Tratamento
20.
Clin Res Cardiol ; 104(3): 217-25, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25349065

RESUMO

BACKGROUND: This study investigated p aclitaxel-induced luminal changes following drug-coated balloon (DCB) angioplasty to treat coronary de novo lesions without additional stenting. DCB-mediated local drug delivery reduces late lumen loss in de novo coronary artery lesions. We performed a retrospective clinical assessment based on a pre-specified quantitative coronary angiography (QCA) protocol. METHODS: QCA was performed for each centre to assess the primary endpoint late lumen changes, i.e. the difference between in-lesion minimal lumen diameter (MLD) at the routine angiographic follow-up as compared to post-procedural in-lesion MLDs. These MLD changes were compared to corresponding reference vessel diameter changes as an intra-patient control. RESULTS: We evaluated 58 consecutive native coronary artery lesions directly after DCB angioplasty and at a routine target follow-up angiography of 4 months by QCA. Target lesion MLD increased significantly within the 4.1 ± 2.1 month observation period (1.75 ± 0.55 vs. 1.91 ± 0.55 mm, p < 0.001, diameter stenosis 33.8 ± 12.3 vs. 26.9 ± 13.8 %, p < 0.001), while there were no changes in non-target reference vessel diameters (2.33 ± 0.60 vs. 2.34 ± 0.61 mm, p = ns). A total of 69 % of patients showed luminal enlargement whereas 29 % had minor luminal loss. CONCLUSION: Local application of paclitaxel by DCB angioplasty to native coronary arteries after pre-dilatation without major dissection and recoil leads to late lumen increase.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Vasos Coronários/efeitos dos fármacos , Paclitaxel/administração & dosagem , Remodelação Vascular/efeitos dos fármacos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Neointima , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento