Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 391
Filtrar
5.
JAMA Intern Med ; 182(10): 1091-1092, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35994257

RESUMO

This case report describes a patient in their 60s with atrial flutter ablation following admission to the hospital for heart failure exacerbation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Eletrocardiografia , Humanos
6.
Can J Cardiol ; 38(8): 1271-1276, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35346798

RESUMO

BACKGROUND: Patients with hemodynamically tolerated ventricular tachycardia (VT) and minimally reduced left ventricular ejection fraction (LVEF) remain a group that presents a prognostic and therapeutic dilemma. METHODS: We studied patients from our implanted cardioverter-defibrillator (ICD) database who received ICDs for hemodynamically tolerated VT and mildly reduced LVEF (36%-49%) at time of implant between May 2015 and December 2019. Time to appropriate ICD therapy was assessed. Clinical features associated with recurrent VT/ventricular fibrillation (VF) with ICD therapies were explored using binary logistic regression. RESULTS: Among 2037 ICDs placed between May 2015 and December 2019, 64 subjects met the inclusion criteria. The mean age of the study group was 68 ± 12 years, and 58 (90.6%) subjects were male. Average ejection fraction was 40% ± 4.4 (range 36%-49%). Twenty-two (34%) subjects received antitachycardia pacing (ATP) for VT at 229 ± 265 days after ICD placement. Fifteen (23%) subjects received appropriate ICD shocks 305 ± 321 days after implant. The rate of recurrent VT/VF among the 37 patients with ICD therapy was 195 ± 39 beats per minute (bpm). This was significantly more rapid than initial presenting VT rates before ICD placement (183 ± 27 bpm) (P = 0.048). Multivariate analysis showed no factors independently associated with recurrent VT/VF. CONCLUSIONS: Patients with mildly impaired LV function and hemodynamically tolerated VT receive appropriate ICD therapies over the 3 years following implant. This patient group warrants further investigation, as their recurrent VT/VF rates can be much more rapid, and 23% go on to receive appropriate ICD shocks.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas , Cardioversão Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Função Ventricular Esquerda
7.
JACC Clin Electrophysiol ; 6(10): 1246-1252, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33092750

RESUMO

OBJECTIVES: This study sought to identify minimum threshold values below which conduction over the atrioventricular (AV) node would be unexpected. BACKGROUND: Para-Hisian pacing is used to evaluate for the presence of a septal accessory pathway (AP); however, threshold values to differentiate nodal from AP conduction are unknown. METHODS: The authors performed high- and low-output para-Hisian pacing during sinus rhythm to capture the His and para-Hisian ventricular myocardium (H+V) and para-Hisian ventricular myocardium (V) alone, respectively. The change in stimulation (stim)-to-atrial electrogram interval after loss of His bundle capture in patients with (AP+) and without (AP-) a septal AP was evaluated. Stim-to-proximal coronary sinus (PCS) and stim-to-high right atrium (HRA) intervals were measured and within-patient differences (△) for V and H+V capture were calculated. RESULTS: A total of 23 AP+ and 45 AP- patients were evaluated. The difference in stimulus to earliest atrial signal in the high right atrial catheter seen with the loss of His bundle capture (△-stim-HRA) (21 ms; interquartile range [IQR]: 3 to 43 ms vs. 64 ms; IQR: 56 to 73 ms; p < 0.001) and difference in stimulus to earliest atrial signal in the proximal coronary sinus catheter seen with the loss of His Bundle capture (△-stim-PCS) (11 ms; IQR: 0 to 30 ms vs. 61 ms; IQR: 52 to 72 ms; p < 0.001) were shorter in AP+ patients. The shortest △-stim-PCS and △-stim-HRA in AP- patients were 37 ms and 32 ms, respectively, whereas the longest corresponding intervals in AP+ patients were 51 ms and 75 ms, respectively. CONCLUSIONS: A △-stim-PCS <37 ms or △-stim-HRA <32 ms confirmed the presence of a septal AP, whereas a value >51 ms for △-stim-PCS or >75 ms for △-stim-HRA excluded it. Alternatively, the minimum △-stim-PCS with loss of His capture compatible with AV nodal conduction in isolation was 37 ms, and a △-stim-PCS >51 ms effectively ruled out the presence of a septal AP.


Assuntos
Taquicardia por Reentrada no Nó Atrioventricular , Nó Atrioventricular , Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Humanos
8.
J Cardiovasc Electrophysiol ; 31(12): 3207-3214, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32936492

RESUMO

INTRODUCTION: Septal accessory pathway (AP) ablation can be challenging due to the complex anatomy of the septal region. The decision to access the left atrium (LA) is often made after failure of ablation from the right. We sought to establish whether the difference between ventriculo-atrial (VA) time during right ventricular (RV) apical pacing versus the VA during tachycardia would help establish the successful site for ablation of septal APs. METHODS: Intracardiac electrograms of patients with orthodromic reciprocating tachycardia (ORT) using a septal AP with successful catheter ablation were reviewed. The ∆VA was the difference between the VA interval during RV apical pacing and the VA interval during ORT. The difference in the VA interval during right ventricular entrainment and ORT (StimA-VA) was also measured. RESULTS: The median ∆VA time was significantly less in patients with a septal AP ablated on the right side compared with patients with a septal AP ablated on the left side (12 ± 19 vs. 56 ± 10 ms, p < .001). The StimA-VA was significantly different between the two groups (22 ± 14 vs. 53 ± 9 ms, p < .001). The ∆VA and StimA-VA were always ≤ 40 ms in patients with non-decremental septal APs ablated from the right side and always greater than 40 ms in those with septal APs ablated from the left. CONCLUSION: ΔVA and StimA-VA values identified with RV apical pacing in the setting of ORT involving a septal AP predict when left atrial access will be necessary for successful ablation.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Feixe Acessório Atrioventricular/cirurgia , Fascículo Atrioventricular , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
10.
Pacing Clin Electrophysiol ; 43(12): 1599-1604, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32597505

RESUMO

Cross-talk is a well-described phenomenon in a dual-chamber cardiovascular implantable electronic device. Far-field ventricular events are more commonly sensed in the atrial channel, the reverse is uncommon, and seeing both at the same time has never been reported. We present a case of double cross-talk in a dual-chamber Medtronic ® implantable cardioverter-defibrillator. In this report, we decipher an unusual device response to the cross-talk and describe the programming changes required to resolve it.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Idoso , Algoritmos , Eletrocardiografia , Análise de Falha de Equipamento , Humanos , Masculino
11.
Proc Natl Acad Sci U S A ; 117(27): 15673-15683, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32571933

RESUMO

Stemness encompasses the capability of a cell for self-renewal and differentiation. The stem cell maintains a balance between proliferation, quiescence, and regeneration via interactions with the microenvironment. Previously, we showed that ectopic expression of the mitochondrial ribosomal protein S18-2 (MRPS18-2) led to immortalization of primary fibroblasts, accompanied by induction of an embryonic stem cell (ESC) phenotype. Moreover, we demonstrated interaction between S18-2 and the retinoblastoma-associated protein (RB) and hypothesized that the simultaneous expression of RB and S18-2 is essential for maintaining cell stemness. Here, we experimentally investigated the role of S18-2 in cell stemness and differentiation. Concurrent expression of RB and S18-2 resulted in immortalization of Rb1-/- primary mouse embryonic fibroblasts and in aggressive tumor growth in severe combined immunodeficiency mice. These cells, which express both RB and S18-2 at high levels, exhibited the potential to differentiate into various lineages in vitro, including osteogenic, chondrogenic, and adipogenic lineages. Mechanistically, S18-2 formed a multimeric protein complex with prohibitin and the ring finger protein 2 (RNF2). This molecular complex increased the monoubiquitination of histone H2ALys119, a characteristic trait of ESCs, by enhanced E3-ligase activity of RNF2. Furthermore, we found enrichment of KLF4 at the S18-2 promoter region and that the S18-2 expression is positively correlated with KLF4 levels. Importantly, knockdown of S18-2 in zebrafish larvae led to embryonic lethality. Collectively, our findings suggest an important role for S18-2 in cell stemness and differentiation and potentially also in cancerogenesis.


Assuntos
Mitocôndrias/genética , Células-Tronco Embrionárias Murinas/metabolismo , Proteínas de Ligação a Retinoblastoma/genética , Proteínas Ribossômicas/genética , Animais , Diferenciação Celular/genética , Proliferação de Células/genética , Autorrenovação Celular/genética , Fibroblastos/metabolismo , Regulação da Expressão Gênica no Desenvolvimento/genética , Histonas/genética , Células-Tronco Embrionárias Humanas/metabolismo , Humanos , Fator 4 Semelhante a Kruppel , Fatores de Transcrição Kruppel-Like/genética , Camundongos , Mitocôndrias/metabolismo , Complexo Repressor Polycomb 1/genética , Proteínas Ribossômicas/química , Microambiente Tumoral/genética , Ubiquitina-Proteína Ligases/genética
12.
Am Heart J ; 226: 152-160, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32580074

RESUMO

It is assumed that electrical cardioversion (ECV) improves the quality of life (QoL) of patients with atrial fibrillation (AF) by restoring sinus rhythm (SR). OBJECTIVE: We examined the effect of ECV and rhythm status on QoL of patients with symptomatic persistent AF in a randomized controlled trial. METHOD: The elective cardioversion for prevention of symptomatic atrial fibrillation trial examined the efficacy of dronedarone around the time of ECV in maintaining SR. Quality of life was measured with the University of Toronto Atrial Fibrillation Severity Scale. The primary outcome was the change in AF symptom severity (∆AFSS) score over 6 months (0-35 points, with higher scores reflecting worse QoL and a minimal clinically important difference defined as ∆AFSS ≥3 points). Multivariable linear regression was performed to identify factors associated with changes in QoL. RESULTS: We included 148 patients with complete AFSS scores at baseline and 6 months. Over 6 months, QoL improved irrespective of rhythm status (ΔAFSS scores for patients who (i) maintained SR; (ii) had AF relapse after successful ECV; and (iii) had unsuccessful ECV were -6.8 ±â€¯6.4 points, -4.1 ±â€¯6.2 points, and -4.0 ±â€¯5.8 points respectively, P < .01 for all subgroups). After adjustment of baseline covariates, maintenance of SR was associated with QoL improvement (ΔAFSS: -3.8 points, 95% CI: -6.0 to -1.6 points, P < .01). CONCLUSIONS: Maintenance of SR was associated with clinically relevant improvement in patients' QoL at 6 months. Patients with AF recurrence had a small but still relevant improvement in their QoL, potentially due to factors other than sinus rhythm.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica , Qualidade de Vida , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Motivação , Fatores de Tempo , Resultado do Tratamento
14.
JACC Clin Electrophysiol ; 5(4): 504-512, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-31000106

RESUMO

OBJECTIVES: The authors studied the response rates and relative sensitivity of the most common agents used in the sodium-channel blocker (SCB) challenge. BACKGROUND: A type 1 Brugada electrocardiographic pattern precipitated by an SCB challenge confers a diagnosis of Brugada syndrome. METHODS: Patients undergoing an SCB challenge were prospectively enrolled across Canada and the United Kingdom. Patients with no prior cardiac arrest and family histories of sudden cardiac death or Brugada syndrome were included. RESULTS: Four hundred twenty-five subjects underwent SCB challenge (ajmaline, n = 331 [78%]; procainamide, n = 94 [22%]), with a mean age of 39 ± 15 years (54% men). Baseline non-type 1 Brugada ST-segment elevation was present in 10%. A total of 154 patients (36%) underwent signal-averaged electrocardiography, with 41% having late potentials. Positive results were seen more often with ajmaline than procainamide infusion (26% vs. 4%, p < 0.001). On multivariate analysis, baseline non-type 1 Brugada ST-segment elevation (odds ratio [OR]: 6.92; 95% confidence interval [CI]: 3.15 to 15.2; p < 0.001) and ajmaline use (OR: 8.76; 95% CI: 2.62 to 29.2; p < 0.001) were independent predictors of positive results to SCB challenge. In the subgroup undergoing signal-averaged electrocardiography, non-type 1 Brugada ST-segment elevation (OR: 9.28; 95% CI: 2.22 to 38.8; p = 0.002), late potentials on signal-averaged electrocardiography (OR: 4.32; 95% CI: 1.50 to 12.5; p = 0.007), and ajmaline use (OR: 12.0; 95% CI: 2.45 to 59.1; p = 0.002) were strong predictors of SCB outcome. CONCLUSIONS: The outcome of SCB challenge was significantly affected by the drug used, with ajmaline more likely to provoke a type 1 Brugada electrocardiographic pattern compared with procainamide. Patients undergoing SCB challenge may have contrasting results depending on the drug used, with potential clinical, psychosocial, and socioeconomic implications.


Assuntos
Ajmalina/farmacologia , Síndrome de Brugada/diagnóstico , Eletrocardiografia/efeitos dos fármacos , Procainamida/farmacologia , Bloqueadores do Canal de Sódio Disparado por Voltagem/farmacologia , Adulto , Síndrome de Brugada/fisiopatologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Europace ; 20(suppl_3): iii55-iii68, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30476055

RESUMO

AIMS: Treatments for persistent atrial fibrillation (AF) offer limited efficacy. One potential strategy aims to return the right atrium (RA) to sinus rhythm (SR) by ablating interatrial connections (IAC) to isolate the atria, but there is limited clinical data to evaluate this ablation approach. We aimed to use simulation to evaluate and predict patient-specific suitability for ablation of IAC to treat AF. METHODS AND RESULTS: Persistent AF was simulated in 12 patient-specific geometries, incorporating electrophysiological heterogeneity and fibres, with IAC at Bachmann's bundle, the coronary sinus, and fossa ovalis. Simulations were performed to test the effect of left atrial (LA)-to-RA frequency gradient and fibrotic remodelling on IAC ablation efficacy. During AF, we simulated ablation of one, two, or all three IAC, with or without pulmonary vein isolation and determined if this altered or terminated the arrhythmia. For models without structural remodelling, ablating all IAC terminated RA arrhythmia in 83% of cases. Models with the LA-to-RA frequency gradient removed had an increased success rate (100% success). Ablation of IACs is less effective in cases with fibrotic remodelling (interstitial fibrosis 50% success rate; combination remodelling 67%). Mean number of phase singularities in the RA was higher pre-ablation for IAC failure (success 0.6 ± 0.8 vs. failure 3.2 ± 2.5, P < 0.001). CONCLUSION: This simulation study predicts that IAC ablation is effective in returning the RA to SR for many cases. Patient-specific modelling approaches have the potential to stratify patients prior to ablation by predicting if drivers are located in the LA or RA. We present a platform for predicting efficacy and informing patient selection for speculative treatments.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Função do Átrio Direito , Ablação por Cateter , Átrios do Coração/cirurgia , Frequência Cardíaca , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Tomada de Decisão Clínica , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Seleção de Pacientes , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 29(1): 167-176, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29044787

RESUMO

INTRODUCTION: Radiofrequency (RF) ablation is effective for slow pathway ablation, but carries a risk of inadvertent AV block requiring permanent pacing. By comparison, cryoablation with a 4-mm distal electrode catheter has not been reported to cause permanent AV block but has been shown to be less effective than RF ablation. We sought to define the safety and efficacy of a 6-mm distal electrode cryoablation catheter for slow pathway ablation in patients with atrioventricular nodal reentry tachycardia (AVNRT). METHODS AND RESULTS: Twenty-six U.S. and eight Canadian centers participated in the study. Patients with supraventricular tachycardia (SVT) thought likely to be AVNRT were enrolled. If AVNRT was inducible and confirmed to be the clinical SVT, then the slow pathway was targeted with a cryoablation catheter using a standardized protocol of best practices. Acute success was defined as inducibility of no more than one echo beat after cryoablation. Primary efficacy was defined as acute success and the absence of documented recurrent AVNRT over 6 months of follow-up. Primary safety was a composite of serious procedure-related adverse events and/or device-related complications. Note that 397 subjects met enrollment criteria after the EP study and received cryoablation. Mean ablation procedure duration (including a waiting period) was 89 ± 40 minutes, and mean fluoroscopy time was 4.8 ± 5.9 minutes. Isoproterenol was administered before cryoablation in 53% and after the last lesion in 85% of cases. Acute procedural success was realized in 95% (378 of 397) of subjects. No subject received a permanent pacemaker due to AV block. The slow pathway could not be ablated in 19 subjects, including: 12 due to inefficacy, 2 due to transient AV block, and 5 due to both inefficacy and transient AV block. RF ablation was used in the same procedure in 11 of 19 failed subjects, and was ineffective in 3 subjects. Among the group with acute success, 10 subjects (2.7%) had documented recurrent AVNRT over the 6-month follow-up period, and all occurred within 3 months of the index cryoablation. Serious procedure-related adverse events occurred in 4 subjects (1.0%), including one each: tamponade, pulmonary embolism, femoral vein hemorrhage, and diagnostic EP catheter knotting. None of these serious adverse events were related to use of the cryoablation catheter. Overall, 93% of subjects had successful slow pathway ablation at 6 months with the study cryoablation catheter. CONCLUSIONS: Cryoablation for AVNRT using a focal 6-mm catheter was safe and effective. It resulted in a low risk of recurrence over 6 months of follow-up with no incidence of AV block requiring permanent pacing.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Criocirurgia/instrumentação , Sistema de Condução Cardíaco/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Criocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Estudos Prospectivos , Recidiva , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...